Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Parametric Design Studies on a Direct Liquid Feed Fuel Cell

Parametric design studies were carried out on a direct methanol liquid feed fuel cell employing 1 M MeOH fuel, air and oxygen as oxidant in a 2 inch x 2 inch cell employing polymeric electrolyte membranes. Measurements include voltage-current output parameters, methanol crossover rate, and impedance as a function of several design and operational variables. Design variables are described.

Fuel Cell Advanced Research Projects Agency↗

Thermal Characterization Study of Lithium-Ion Cells

The primary challenge in designing a full scale lithium-ion (Li-ion) battery system is safety under both normal operating as well as abusive conditions. The normal conditions involve expected charge/discharge cycles and it is known that heat evolves in batteries during those cycles. This is a major concern in the design for high power applications and careful thermal management is necessary to alleviate this concern. An emerging thermal measurement technology, such as the electrochemical calorimetric of batteries, will aid in the development of advanced, safe battery system. To support this technology, several "commercial-off-the-shelf" (COTS) Li-ion cells with different chemistries and designs are being evaluated for different cycling regimes at a given operating temperature. The Accelerated Rate Calorimeter (ARC)-Arbin cycler setup is used to measure the temperature, voltage, and current of the cells at different charge/discharge rates. Initial results demonstrated good cell cyclability. During the cycle testing, the cell exhibited an endothermic cooling in the initial part of the charge cycle. The discharge portion of the cycle is exothermic during the entire discharge period. The presence of an endothermic reaction indicates a significant entropy effect during the beginning of charge cycle. Further studies will be performed to understand the thermal characteristics of the Li-ion cells at the different operating conditions. The effects on the thermal response on cell aging and states-of-charge will also be identified.

Britton, Doris L.↗

Better Modeling of Electrostatic Discharge in an Insulator

An improved mathematical model has been developed of the time dependence of buildup or decay of electric charge in a high-resistivity (nominally insulating) material. The model is intended primarily for use in extracting the DC electrical resistivity of such a material from voltage -vs.- current measurements performed repeatedly on a sample of the material over a time comparable to the longest characteristic times (typically of the order of months) that govern the evolution of relevant properties of the material. This model is an alternative to a prior simplistic macroscopic model that yields results differing from the results of the time-dependent measurements by two to three orders of magnitude.

Pekov, Mihail↗

Nearly Direct Measurement of Relative Permittivity

A recently conceived technique for determining the relative permittivity of a material sample at a given frequency is more nearly direct than are prior techniques that involve measurement of such related non-electrical quantities as the size, shape, and/or weight of the specimen. The present technique involves only measurement of two voltages at the frequency in question, followed by calculation of the ratio between the voltages. The technique requires two circuits a test circuit and a reference circuit that are identical except as described below. Each circuit includes a capacitor C1 connected in series with a much larger capacitor C2 to form a voltage divider (see figure). C1 is a parallel-plate capacitor. The top electrode of C1 is connected to an AC signal source of voltage Va at the frequency of interest. The top electrode of C1 is surrounded by a guard electrode that, in turn, is surrounded by a grounded electrode. The bottom electrode of C1 is connected to the top electrode of C2. The bottom electrode of C2 is grounded. The volume enclosed by the top, bottom, and guard electrodes of C1 constitutes a sample cell. A material sample, having relative permittivity k at the frequency of interest, is placed in the sample cell. The exact shape and size of the sample volume is not critical and can be chosen to fit the material sample. What is critical is that (a) C2 in both circuits be identical and (b) the sample cell in the test circuit have the same size and shape as that in the reference circuit, so that the capacitances of the two sample cells are proportional to the permittivities of their contents.

Calle, Carlos I.↗

Ferrocene Containing Copolymers with Improved Electrostatic Dissipation Properties for Advanced Applications

Electrostatic dissipative polymers are used for a variety of functions. Typical methods utilized to transform electrically insulating polymers into either charge dissipative or conductive materials involve incorporating a conductive filler, conductive polymer, oxidizing the surface using plasma, or incorporating surfactants that act as surface wetting agents. Another approach is to synthesize a block copolymer that is expected to result in better electrical properties with minimal impacts to physical, fire, and thermal properties. One such block that can be added into the main chain of polymers is a diol terminated ferrocene oligomer, which is expected to impart electrostatic dissipative properties into the host polymer while concurrently improving the overall fire properties. Previous work with polyurethanes incorporating a ferrocene oligomer into the main chain resulted in much improved fire retardancy. In dealing with electrostatic dissipative materials the important questions are: how easily does the material charge and how quickly can the charge move to ground. One normally describes the materials conductivity, but conductivity only measures the fastest path for an electron not the slowest path. The slowest path is the one of interest, since it is left on the surface and thus can cause discharges. In order to assess ease of charging and decay times corona charge dissipation measurements can accurately assess these properties by introducing a charge on the surface of the material then measuring the surface voltage and the amount of charge deposited. The charge decay curve then will give an indication of a materials electrostatic dissipation properties. Normally, triboelectric testing can be performed, but results vary. Corona charge dissipation results are more repeatable.

Smith, T. M.↗

Optical Diagnostic Characterization of High-Power Hall Thruster Wear and Operation

Optical emission spectroscopy is employed to correlate BN insulator erosion with high-power Hall thruster operation. Specifically, actinometry leveraging excited xenon states is used to normalize the emission spectra of ground state boron as a function of thruster operating condition. Trends in the strength of the boron signal are correlated with thruster power, discharge voltage, and discharge current. In addition, the technique is demonstrated on metallic coupons embedded in the walls of the HiVHAc EM thruster. The OES technique captured the overall trend in the erosion of the coupons which boosts credibility in the method since there are no data to which to calibrate the erosion rates of high-power Hall thrusters. The boron signals are shown to trend linearly with discharge voltage for a fixed discharge current as expected. However, the boron signals of the higher-power NASA 300M and NASA 457Mv2 trend with discharge current and show an unexpectedly weak to inverse dependence on discharge voltage. Electron temperatures measured optically in the near-field plume of the thruster agree well with Langmuir probe data. However, the optical technique used to determine Te showed unacceptable sensitivity to the emission intensities. Near-field, single-frequency imaging of the xenon neutrals is also presented as a function of operating condition for the NASA 457 Mv2.

Williams, George J., Jr.↗

Examination of Annular-Electrode Spark Discharges in Flowing Oxygen - An Overview

A parametric study of annular spark gaps, pressures, and spark discharges in flowing oxygen gas was performed with a Champion spark exciter. The range of the pressure-distance product for the experiment is from approximately 50 torr-cm to 2500 torr-cm. Measurements of breakdown voltage qualitatively trend with Paschen's curve. Spark duration remained constant until the pressure-distance product exceeded 200 torr-cm, and then steadily increased. The mean spark energy increases linearly with the pressure-distance on a log-log plot indicating that a definite power relationship exists. The distribution of sparks at low energies and low pressures is not Gaussian and has no dominant peaks. Moderate and high spark energies are bimodal, with the dominant mode near 80 mJ. As pressure increases, dominant and secondary modes approach the same probability.

Darren C. Tinker↗

Thin-Film Embedded Sensors for Battery Health Monitoring

Hybrid or all-electric aircraft are being developed as the next generation of aircraft to both allow new forms of aviation and decrease environmental impact. Since these types of aircraft are based on high-capacity battery technology, safe operation of these batteries becomes increasingly important. In particular, the potential for battery failure due to uncontrolled chemical reactions resulting in thermal runaway, catastrophic failure, and battery fires must be addressed in order for such battery technology to have the level of safety needed for standard aviation implementation. Efforts to ensure battery safety often involve engineering solutions that seek to contain rather than prevent such events by early detection. Such approaches increase the system weight and decrease the power per unit mass provided by the battery system. Existing methods for measuring battery parameters to determine the battery state-of-health are limited. These methods include electrical measurements of the cell current and/or voltage output as well as temperature measurements taken externally on the cell surface. Such external temperature measurements are limited in their ability to provide early warning of impending battery failure. In response, an effort to develop sensors operating internal to battery for health monitoring has been ongoing in the NASA Sensor-based Prognostics to Avoid Runaway Reactions & Catastrophic Ignition (SPARRCI) project. The basic approach associated with this sensor work is the deposition of thin film sensors on the battery separator located between the anode and cathode of the battery. These thin film sensors are then monitored to determine changes in battery parameters and health. Microfabrication techniques are employed to minimize the overall impact of the sensors on battery operation through the implementation of sensors with minimal size, weight, and power consumption. The thickness of the films, which are fabricated through physical vapor deposition (sputtering), are on the order of thousands of angstroms and can have minimal surface area. Thin film sensors for system health management have been implemented for a many decades on complex components for aerospace applications. However, the application of thin films of this type on a battery separator for internal battery monitoring applications has not previously been demonstrated to our knowledge. This paper describes the development of sensors for the internal battery monitoring through the use of thin film sensor technology. Thin metal films were successfully deposited on a battery separator polymer material with good adherence and electrical continuity. Multiple types of sensors have been deposited, as well as lead connections from the sensor to the edge of the separator material. The ability of these thin film sensors immersed in electrolyte to perform multiple types of battery parameter measurements has been demonstrated. For example, a multiparameter sensor system measured multiple properties simultaneously inside of a pouch cell over a wide temperature range. Further, real time measurement of interior temperature changes in a battery pouch cell with an integrated interior temperature sensor was demonstrated. These changes include detecting a fault in the battery (shorting) in situ with rapid response time (less than a minute) corresponding to a more limited response by a temperature sensor mounted externally. Other aspects of monitoring battery health were also explored, such as real-time measurement of simulated dendrite growth/metal deposition by sensor on separator material demonstrated. Future efforts will include improvements in the durability of the sensor structure to allow introduction of the approach into standard battery fabrication techniques. Overall, this work is a step forward in providing a method to prevent catastrophic battery failures and provide a foundation for safer, lighter, and higher energy batteries for the electric aircraft industry.

thin film battery health↗

Impedance Matching of Tapered Slot Antenna using a Dielectric Transformer

A new impedance matching technique for tapered slot antennas using a dielectric transformer is presented. The technique is demonstrated by measuring the input impedance, Voltage Standing Wave Ratio (VSWR) and the gain of a Vivaldi antenna (VA). Measured results at Ka-Band frequencies are presented and discussed.

Simons, R. N.↗

Behavior of inversion layers in 3C silicon carbide

A study on the field-induced surface-charge region in 3C silicon carbide (SiC) using 1 MHz capacitance-voltage (C-V) measurements at room temperature is here reported. A double column mercury probe was used on oxidized SiC substrates to form metal-oxide-semiconductor (MOS) structures. These structures were characterized in terms of the substrate doping profile, effective fixed oxide charge, and interface trap density. A distinctive feature of the MOS C-V curves from accumulation to inversion is that after going into deep depletion the capacitance rises to its equilibrium inversion level during the voltage sweep. Capacitance transient measurements indicate that the minority-carrier generation occurs at the SiO2/SiC interface.

Avila, R. E.↗

A distributed data acquisition system for aeronautics test facilities

The NASA Lewis Research Center is in the process of installing a new data acquisition and display system. This new system will provide small and medium sized aeronautics test facilities with a state-of-the-art real-time data acquisition and display system. The new data system will provide for the acquisition of signals from a variety of instrumentation sources. They include analog measurements of temperatures, pressures, and other steady state voltage inputs; frequency inputs to measure speed and flow; discrete I/O for significant events, and modular instrument systems such as multiplexed pressure modules or electronic instrumentation with a IEEE 488 interface. The data system is designed to acquire data, convert it to engineering units, compute test dependent performance calculations, limit check selected channels or calculations, and display the information in alphanumeric or graphical form with a cycle time of one second for the alphanumeric data. This paper describes the system configuration, its salient features, and the expected impact on testing.

Fronek, Dennis L.↗

A distributed data acquisition system for aeronautics test facilities

The NASA Lewis Research Center is in the process of installing a new data acquisition and display system. This new system will provide small and medium sized aeronautics test facilities with a state-of-the-art real-time data acquisition and display system. The new data system will provide for the acquisition of signals from a variety of instrumentation sources. They include analog measurements of temperatures, pressures, and other steady state voltage inputs; frequency inputs to measure speed and flow; discrete I/O for significant events, and modular instrument systems such as multiplexed pressure modules or electronic instrumentation with a IEEE 488 interface. The data system is designed to acquire data, convert it to engineering units, compute test dependent performance calculations, limit check selected channels or calculations, and display the information in alphanumeric or graphical form with a cycle time of one second for the alphanumeric data. This paper describes the system configuration, its salient features, and the expected impact on testing.

Fronek, Dennis L.↗

Electrolyte and Electrode Passivation for Thin Film Batteries

Passivation films for thin film batteries have been prepared and the conductivity and voltage stability window have been measured. Thin films of Li2CO3 have a large voltage stability window of 4.8V, which facilitates the use of this film as a passivation at both the lithium anode-electrolyte interface at high cathodic potentials.

passivation thin film batteries↗

Method and Apparatus for In-Situ Health Monitoring of Solar Cells in Space

Embodiments of the present invention describe an apparatus including an oscillator, a ramp generator, and an inverter. The oscillator is configured to generate a waveform comprising a low time and a high time. The inverter is configured to receive the waveform generated by the oscillator, and invert the waveform. The ramp generator is configured to increase a gate control voltage of a transistor connected to a solar cell, and rapidly decrease the gate control voltage of the transistor. During the low time, a measurement of a current and a voltage of the solar cell is performed. During the high time, a measurement of a current of a shorted cell and a voltage reference is performed.

Krasowski, Michael J.↗

Automatic Control Of Length Of Welding Arc

Nonlinear relationships among current, voltage, and length stored in electronic memory. Conceptual microprocessor-based control subsystem maintains constant length of welding arc in gas/tungsten arc-welding system, even when welding current varied. Uses feedback of current and voltage from welding arc. Directs motor to set position of torch according to previously measured relationships among current, voltage, and length of arc. Signal paths marked "calibration" or "welding" used during those processes only. Other signal paths used during both processes. Control subsystem added to existing manual or automatic welding system equipped with automatic voltage control.

Iceland, William F.↗

Lightning instrumentation for warning and measurement

A presentation of instrumentation techniques used at Kennedy Space Center for assessing the hazards of lightning, measure lightning currents, induced voltage effects and assess the probability of lightning strikes to launch structures. The electric field and sferics are measured to determine the lightning hazard from the clouds. Measurements are made on launch structures to determine the magnitude of lightning currents and the induced voltages. Photographs are taken to ascertain the location of lightning strikes. Data is analyzed and presented on operations personnel and the Weather Office for assessment of impact on launch critical electromechanical systems and industrial operations.

Wojtasinski, R. J.↗

Research, Development and Fabrication of Lithium Solar Cells

This report continues studies on cells made with low temperature (<400degC) single-cycle, lithium diffusion schedules. Measurements of concentration of lithium at the back surface showed that C(sub S) changes with time consisting of a build-up to a maximum value (above 10(exp 17) cm(exp -3)) with gradual decrease at longer diffusion times. Using the estimated C(sub S) values, theoretical lithium profiles were calculated. The calculated concentration near the PN junction was higher than those measured by the capacitance voltage (C-V) technique. The calculated concentration gradients were one-seventh of those measured by C-V methods. Both the concentration and its gradient were proportional to C(sub S). Estimates of C(sub S) obtained by extrapolating from C-V measured values of concentration and gradient near the PN junction, showed a decrease in C(sub S) for longer diffusion times. This fact supported the trend observed in Shipment C-13, where,, at longer times, the spread in values of V(sub oc), lithium concentration, and gradient became greater. The general conclusion was that the I-V characteristics were well controlled, with good cell output, but for longer diffusion times the lithium concentration gradient could have wider spread. The work described has led to greater insight into the lithium distribution dependence on the surface conditions. The surface conditions could be changed by varying the method used to apply lithium. Vacuum evaporation of lithium shows promise, and another exhaustive test of this method is in progress. Shipment C-13 is summarized, and the succeeding lots (C-14, C-15) are described. It is felt that improved monitoring of cell properties is at hand, and that the control of cell fabrication processes has advanced to where the effects of subtle differences in lithium distribution can now be seen. Evaluation is continuing on the best method to scale up the fabrication steps. A different sequence of fabrication is planned for Shipments C-14 and C-15.

Iles, Peter A.↗

Synthesis and thermoeletric properties of Co(sub (1-x)ni)(sub X)P(sub 3) and CoAs((sub 3-x))P(sub x) skutterudites

Two types of promising phosphide skutterudite materials, Co(1-x)NixP3 (x= 0.025 to 0.70) and CoAs(3-x)Px (x=0.5 to 0.10), have been synthesized and their transport properties measured. These compounds were prepared using a direct synthesis technique. The samples were hot pressed and analyzed by electron microprobe microscopy. Hall Effect measurements were conducted to determine the electrical conductivity, mobility and carrier concentration. In addition, Seebeck voltage and thermal conductivity measurements were performed. The thermoelectric properties are presented anddiscussed as a function of temperature up to 1273 K. The thermal stability of the primary CoP3 was examined in a static vacuum under isothermal and in-gradient conditions. The effect of the presence of 1 atm of a cover gas on the material loss rate was analyzed.

thermoelectric↗