Use of Generalized Fluid System Simulation Program (GFSSP) for Teaching and Performing Senior Design Projects at the Educational Institutions

This paper describes the experience of the authors in using the Generalized Fluid System Simulation Program (GFSSP) in teaching Design of Thermal Systems class at University of Alabama in Huntsville. GFSSP is a finite volume based thermo-fluid system network analysis code, developed at NASA/Marshall Space Flight Center, and is extensively used in NASA, Department of Defense, and aerospace industries for propulsion system design, analysis, and performance evaluation. The educational version of GFSSP is freely available to all US higher education institutions. The main purpose of the paper is to illustrate the utilization of this user-friendly code for the thermal systems design and fluid engineering courses and to encourage the instructors to utilize the code for the class assignments as well as senior design projects.

Majumdar, A. K.↗

Intracranial Effects of Artificial Gravity: A 3T MRI Study

INTRODUCTION Spaceflight associated neuro-ocular syndrome (SANS) is characterized by the development of optic disc edema, posterior globe flattening, choroidal/retinal folds and hyperopic refractive errors1. SANS is hypothesized to be a result of headward fluid shifts that invariably occurs in the microgravity environment. As a countermeasure, artificial gravity (AG) through centrifugation has been proposed to reduce this headward fluid shift, however there is no current proof of benefit. The goal of this study was to determine if the application of AG can prevent or reduce known changes in brain volumetry, internal carotid artery (ICA) stroke volume and cerebral spinal fluid (CSF) flow velocity that occurs during simulated chronic headward fluid shift using head down tilt bed rest (HDTBR) methodology2 as an indicator of countermeasure efficacy. METHODS Healthy volunteers were recruited for an IRB approved HDTBR study performed at the German Aerospace Center in Cologne, Germany. Strict six-degree HDTBR was used as a spaceflight analog to induce a continuous headward fluid shift. HDTBR was carried out for 60 days for all subjects. Short-arm centrifugation was utilized to generate AG equating to ~0.3g of acceleration at the level of the eye. The subjects were divided equally into three groups: NoAG (control; n=8), daily intermittent AG (6 x 5 min iAG; n=8), and daily continuous 30 min (cAG; n=8). All studies were performed on a single dedicated 3T MRI Scanner. Pulse-gated MRI phase-contrast flow imaging was used to quantify ICA stroke volume and peak-to-peak CSF flow velocity in the mid cerebral aqueduct. 3D-SPGR was acquired for volumetric segmentation of the brain and CSF spaces. MRI acquisitions were obtained at baseline (BDC), 14 days into HDTBR (HDTBR14), 52 days into HDTBR (HDTBR52) and 3-5 days after HDTBR (recovery, R+3/5).The data were analyzed by the mixed model, which included intervention and time (BDC, HDTBR 14, HDTBR 52, R+3/5) as the fixed effects and included subject as the random effect.RESULTS24 healthy subject volunteers (16 men, 8 women, mean age = 33 years ± 9 [standard deviation] and mean BMI = 24.3 kg/m2 ± 2.0) successfully completed all phases of the study. Strict six-degree HDTBR was characterized by progressive and statistically significant (p<.01) increases in mean combined brain and CSF volumes and mean aqueductal CSF peak-to-peak flow velocity, as well as statistically significant (p<.01) progressive decrease in mean ICA stroke volume from baseline to 52 days post intervention (Figs. 1-3). Compared to baseline, only combined brain and CSF volumes did not return to baseline values in the recovery period (p=NS). Neither iAG nor cAG exerted any significant effects on the measured MRI brain parameters as compared to HDTBR alone (p=NS). CONCLUSION Our results indicate that HDTBR at 6-degrees was effective in producing alterations in ICA stroke volume, aqueductal CSF flow velocity, and combined brain and CSF volumetric change that is associated with chronic headward fluid shift. Short duration, 30-min daily exposure to either iAG or cAG appears to be insufficient in preventing or reducing the effects of chronic HDTBR and thus may not be a suitable countermeasure as currently deployed. AG protocol modifications, including increased duration and magnitude of exposure, should be considered for future research.

L A Kramer↗

Is there resetting of central venous pressure in microgravity?

In the early phase of the Space Shuttle program, NASA flight surgeons implemented a fluid-loading countermeasure in which astronauts were instructed to ingest eight 1-g salt tablets with 960 ml of water approximately 2 hours prior to reentry from space. This fluid loading regimen was intended to enhance orthostatic tolerance by replacing circulating plasma volume reduced during the space mission. Unfortunately, fluid loading failed to replace plasma volume in groundbased experiments and has proven minimally effective as a countermeasure against post-spaceflight orthostatic intolerance. In addition to the reduction of plasma volume, central venous pressure (CVP) is reduced during exposure to actual and groundbased analogs of microgravity. In the present study, we hypothesized that the reduction in CVP due to exposure to microgravity represents a resetting of the CVP operating point to a lower threshold. A lower CVP 'setpoint' might explain the failure of fluid loading to restore plasma volume. In order to test this hypothesis, we conducted an investigation in which we administered an acute volume load (stimulus) and measured responses in CVP, plasma volume and renal functions. If our hypothesis is true, we would expect the elevation in CVP induced by saline infusion to return to its pre-infusion levels in both HDT and upright control conditions despite lower vascular volume during HDT. In contrast to previous experiments, our approach is novel in that it provides information on alterations in CVP and vascular volume during HDT that are necessary for interpretation of the proposed CVP operating point resetting hypothesis.

NASA Discipline Cardiopulmonary↗

Analysis of head-down tilt as an analog of weightlessness using a methematical simulation model

Antiorthostasis or head down tilt of a moderate degree was used as a ground based analog of weightless space flight to study headward fluid shifts, decreased plasma volume, orthostatic intolerance and muscular skeletal degradation. A mathematical model was used to help interpret these observations. The model proved most valuable for these studies was originally developed as a description of the major circulatory, fluid and electrolyte control systems. Two different experimental studies are employed to validate the model. The first is a 24 hour head down tilt study and the second is a 7 day head down bed rest study. The major issues addressed include the reduction in plasma volume, the dynamic changes of venous pressure and cardiac output, the extent of central hypervolemia during long term zero g exposure, the existence of an early diuresis, the mechanisms which alter the renal regulating hormones during the short term and long term periods, the significance of potassium loss on other zero g responses, and the role of transcapillary filtration in adjusting fluid shifts. The use of mathematical models as an interpretive and analysis technique for experimental research for space life science is illustrated.

Leonard, J. I.↗

Numerical, Analytical, Experimental Study of Fluid Dynamic Forces in Seals: Description of Seal Dynamics Code DYSEAL and Labyrinth Seals Code KTK - Volume 5

The objectives of the program were to develop computational fluid dynamics (CFD) codes and simpler industrial codes for analyzing and designing advanced seals for air-breathing and space propulsion engines. The CFD code SCISEAL is capable of producing full three-dimensional flow field information for a variety of cylindrical configurations. An implicit multidomain capability allow the division of complex flow domains to allow optimum use of computational cells. SCISEAL also has the unique capability to produce cross-coupled stiffness and damping coefficients for rotordynamic computations. The industrial codes consist of a series of separate stand-alone modules designed for expeditious parametric analyses and optimization of a wide variety of cylindrical and face seals. Coupled through a Knowledge-Based System (KBS) that provides a user-friendly Graphical User Interface (GUI), the industrial codes are PC based using an OS/2 operating system. These codes were designed to treat film seals where a clearance exists between the rotating and stationary components. Leakage is inhibited by surface roughness, small but stiff clearance films, and viscous pumping devices. The codes have demonstrated to be a valuable resource for seal development of future air-breathing and space propulsion engines

Shapiro, Wilbur↗

Magentically actuated compressor

A vibration free fluid compressor particularly adapted for Stirling cycle cryogenic refrigeration apparatus comprises a pair of identical opposing ferromagnetic pistons located in a housing and between a gas spring including a sealed volume of a working fluid such as gas under pressure. The gas compresses and expands in accordance with movement of the pistons to generate a compression wave which can be vented to other apparatus, for example, a displacer unit in a Stirling cycle engine. The pistons are urged outwardly due to the pressure of the gas; however, a fixed electromagnetic coil assembly located in the housing adjacent the pistons, is periodically energized to produce a magnetic field which interlinks the pistons in such a fashion that the pistons are mutually attracted to one another. The mass of the pistons, in conjunction with the compressed gas between them, form a naturally resonant system which, when the pistons are electromagnetically energized, produces an oscillating compression wave in the entrapped fluid medium.

Evans, J.↗

Mitigating Headward Fluid Shifts With Veno-Constrictive Thigh Cuffs During Spaceflight

Astronauts experience a chronic headward fluid shift in weightlessness as evidenced by increased cardiac output, decreased leg volume, a redistribution of venous fluid, and venous congestion in the upper body. Alterations in cerebrospinal fluid hydrodynamics and changes in cerebral venous pressure secondary to the headward fluid shift may contribute to ocular changes associated with spaceflight-associated neuro-ocular syndrome (SANS). Veno-constrictive thigh cuffs (VTC; Braslets) provided to Soyuz crewmembers alleviate symptoms of the headward fluid shift during the first week of spaceflight and have been documented to reduce internal jugular vein (IJV) distension during weightlessness. Application of VTCs designed collaboratively by NASA Johnson Space Center Cardiovascular and Vision Laboratory (CVL) and Clemson Textile Laboratory at Clemson University to improve fit and comfort was documented to mitigate changes in choroid thickness, intraocular pressure, and IJV area during posture-induced headward fluid shifts. VTC are demonstrated to reduce headward fluid shifts in both ground-based and spaceflight studies, and thus, may be a countermeasure against development of SANS. In addition, VTC are a simple mechanical countermeasure currently at a high technical readiness level (TRL) and are compact and lightweight, making them compatible with the spaceflight operations environment

Connor R. Ferguson↗

SRM Internal Flow Tests and Computational Fluid Dynamic Analysis: CFD RSRM Full-Scale Analyses - Volume 2

This document presents the full-scale analyses of the CFD RSRM. The RSRM model was developed with a 20 second burn time. The following are presented as part of the full-scale analyses: (1) RSRM embedded inclusion analysis; (2) RSRM igniter nozzle design analysis; (3) Nozzle Joint 4 erosion anomaly; (4) RSRM full motor port slag accumulation analysis; (5) RSRM motor analysis of two-phase flow in the aft segment/submerged nozzle region; (6) Completion of 3-D Analysis of the hot air nozzle manifold; (7) Bates Motor distributed combustion test case; and (8) Three Dimensional Polysulfide Bump Analysis.

Source record↗

Error and Uncertainty Quantification in the Numerical Simulation of Complex Fluid Flows

The failure of numerical simulation to predict physical reality is often a direct consequence of the compounding effects of numerical error arising from finite-dimensional approximation and physical model uncertainty resulting from inexact knowledge and/or statistical representation. In this topical lecture, we briefly review systematic theories for quantifying numerical errors and restricted forms of model uncertainty occurring in simulations of fluid flow. A goal of this lecture is to elucidate both positive and negative aspects of applying these theories to practical fluid flow problems. Finite-element and finite-volume calculations of subsonic and hypersonic fluid flow are presented to contrast the differing roles of numerical error and model uncertainty. for these problems.

Barth, Timothy J.↗

On the mixture flow problem in lubrication of hydrodynamic bearings - Small solid volume fraction

The lubrication problem of infinitely long slider bearings with a mixture of fluid and particulate solid at small volume fraction level is studied. Closed-form analytical solutions for pressure and shear stress are obtained for a class of solid aggregates. The results reduce to those of pure fluid in the limiting case. A parametric study of the bearing performance with particulate solid is presented.

Khonsari, M. M.↗

The risk of renal stone formation during and after long duration space flight

BACKGROUND: The formation of a renal stone during space flight may have serious negative effects on the health of the crewmember and the success of the mission. Urinary biochemical factors and the influence of dietary factors associated with renal stone development were assessed during long duration Mir Space Station missions. METHODS: Twenty-four-hour urine samples were collected prior to, during and following long duration space flight. The relative urinary supersaturation of calcium oxalate, calcium phosphate (brushite), sodium urate, struvite and uric acid were determined. RESULTS: Changes in the urinary biochemistry of crewmembers during long duration spaceflight demonstrated increases in the supersaturation of the stone-forming salts. In-flight hypercalciuria was evident in a number of individual crewmembers and 24-hour dietary fluid intake and urine volume were significantly lower. During flight, there was a significant increase in brushite supersaturation. CONCLUSIONS: These data suggest acute effects of space flight and postflight changes in the urinary biochemistry favoring increased crystallization in the urine. The effects of dietary intake, especially fluid intake, may have a significant impact on the potential for renal stone formation. Efforts are now underway to assess the efficacy of a countermeasure to mitigate the increased risk.

manned↗

Recovery after exercise in the heat--factors influencing fluid intake

The restoration of body fluid balance following dehydration induced by exercise will occur through regulatory responses which stimulate ingestion of water and sodium ions. A number of different afferent signalling systems are necessary to generate appropriate thirst or sodium appetite. The primary sensory information of naturally occurring thirst is derived from receptors sensing cell volume and the volume of the extracellular fluid compartment. Sensory information from the oropharyngeal region is also an important determinant of thirst. The interaction of these various afferent signalling systems within the central nervous system determines the extent of fluid replacement following dehydration.

Non-NASA Center↗

Changes in leg volume during microgravity simulation

Little published information exists regarding the magnitude and time course of cephalad fluid shift resulting from microgravity simulations. Six subjects were exposed to 150 min each at horizontal bed rest, 6-deg head-down tilt, and horizontal water immersion. Fluid shift was estimated by calculating leg volumes from eight serial girth measurements from groin to ankle before, during, and after exposure. Results were compared with data from the first 3 h of spacecraft. By the end of exposure, total leg volume for the six subjects decreased by 2.6 +/- 0.8 percent, 1.7 +/- 1.2 percent, and 4.0 +/- 1.6 percent for horizontal, head-down, and immersion, respectively. Changes had plateaued for horizontal and head-down and had slowed for immersion. Relatively more fluid was lost from the lower leg than the thigh for all three conditions, particularly head-down. During the first 3 h of spaceflight, total leg volume decreased by 8.6 percent, and relatively more fluid was lost from the thigh than the lower leg. The difference in volume changes in microgravity and simulated microgravity may be caused by the small transverse pressures still present in ground-based simulations and the extremely nonlinear compliance of tissue.

Thornton, William E.↗

Compressibility measurement of fluid-system ullage

Portable self-contained instrument measures volume of free gas or air trapped in closed fluid systems, such as lubricating-oil lines or hydraulic brakes. In response to measurement readings, operator may use device to accurately add or withdraw fluid to or from system.

Dzienis, D. A.↗

Modeling of Compressible Flow with Friction and Heat Transfer Using the Generalized Fluid System Simulation Program (GFSSP)

The present paper describes the verification and validation of a quasi one-dimensional pressure based finite volume algorithm, implemented in Generalized Fluid System Simulation Program (GFSSP), for predicting compressible flow with friction, heat transfer and area change. The numerical predictions were compared with two classical solutions of compressible flow, i.e. Fanno and Rayleigh flow. Fanno flow provides an analytical solution of compressible flow in a long slender pipe where incoming subsonic flow can be choked due to friction. On the other hand, Raleigh flow provides analytical solution of frictionless compressible flow with heat transfer where incoming subsonic flow can be choked at the outlet boundary with heat addition to the control volume. Nonuniform grid distribution improves the accuracy of numerical prediction. A benchmark numerical solution of compressible flow in a converging-diverging nozzle with friction and heat transfer has been developed to verify GFSSP's numerical predictions. The numerical predictions compare favorably in all cases.

Bandyopadhyay, Alak↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

The effect of fluid flow due to the crystal-melt density change on the growth of a parabolic isothermal dendrite

The Ivantsov (1947) analysis of an isolated isothermal dendrite (with zero surface tension) growing into a supercooled liquid is extended to include the effects of the fluid flow due to volume contraction or expansion upon solidification. For an axisymmetric paraboloidal dendrite, an analytic solution to the Navier-Stokes equations is obtained. The magnitude of the flow is proportional to the relative density change epsilon, and the flow becomes negligible far from the surface of the dendrite. The temperature field consistent with this flow can also be found explicitly. The well-known expression that relates the dimensionless supercooling to the Peclet number in the absence of fluid flow is modified for nonzero epsilon, but the effect is of order epsilon and hence is seen to be minor for most values of epsilon and dimensionless supercooling that occur in practice.

Mcfadden, G. B.↗

Electromagnetic probe technique for fluid flow measurements

The probes described herein, in various configurations, permit the measurement of the volume fraction of two or more fluids flowing through a pipe. Each probe measures the instantaneous relative dielectric constant of the fluid in immediate proximity. As long as separation of the relative dielectric constant of the fluid is possible, several or even many fluids can be measured in the same flow stream. By using multiple probes, the velocity of each fluid can generally be determined as well as the distribution of each constituent in the pipe. The values are determined by statistical computation. There are many potential applications for probes of this type in industry and government. Possible NASA applications include measurements of helium/hydrazine flow during rocket tests at White Sands, liquid/gas flow in hydrogen or oxygen lines in Orbiter engines, and liquid/gaseous Freon flow in zero gravity tests with the KS135 aircraft at JSC. Much interest has been shown recently by the oil industry. In this a good method is needed to measure the fractions of oil, water, and natural gas flowing in a pipeline and the velocity of each. This particular problem involves an extension of what has been developed to date and our plans to solve this problem will be discussed herein.