Search NASA⌕ Search

SEARCH · Search NASA

Results for “wireless sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Vestibulo-Ocular Responses to Vertical Translation using a Hand-Operated Chair as a Field Measure of Otolith Function

The translational Vestibulo-Ocular Reflex (tVOR) is an important otolith-mediated response to stabilize gaze during natural locomotion. One goal of this study was to develop a measure of the tVOR using a simple hand-operated chair that provided passive vertical motion. Binocular eye movements were recorded with a tight-fitting video mask in ten healthy subjects. Vertical motion was provided by a modified spring-powered chair (swopper.com) at approximately 2 Hz (+/- 2 cm displacement) to approximate the head motion during walking. Linear acceleration was measured with wireless inertial sensors (Xsens) mounted on the head and torso. Eye movements were recorded while subjects viewed near (0.5m) and far (approximately 4m) targets, and then imagined these targets in darkness. Subjects also provided perceptual estimates of target distances. Consistent with the kinematic properties shown in previous studies, the tVOR gain was greater with near targets, and greater with vision than in darkness. We conclude that this portable chair system can provide a field measure of otolith-ocular function at frequencies sufficient to elicit a robust tVOR.

Wood, S. J.↗

Pilot Field Test: Performance of a Sit-to-Stand Test After Long-Duration Space Flight

BACKGROUND: Astronauts returning from the International Space Station are met by a team of recovery personnel typically providing physical assistance and medical support immediately upon landing. That is because long-duration spaceflight impacts astronauts' functional abilities. Future expeditions to planets or asteroids beyond the low Earth orbit, however, may require crewmembers to egress the vehicle and perform other types of physical tasks unassisted. It is therefore important to characterize the extent and longevity of functional deficits experienced by astronauts in order to design safe exploration class missions. Pilot Field Test (PFT) experiment conducted with participation of ISS crewmembers traveling on Soyuz expeditions 34S - 41S comprised several tasks designed to study the recovery of sensorimotor abilities of astronauts during the first 24 hours after landing and beyond. METHODS: The first test in the PFT battery sequence, and also the least demanding one from the sensorimotor perspective, was a Sit-to-Stand test. Test subjects were seated in the chair and had to stand up on command and remain standing for ten seconds. The subjects were instructed to stand up unassisted as quickly as they were able to, while maintaining postural control. Synchronized wireless inertial sensors mounted on the head, chest, lower back, wrists, and ankles were used to continuously log body kinematics. Crewmembers' blood pressure and heart rate were monitored and recorded with the Portapres and Polar systems. Each session was recorded with a digital video camera. During data collections occurring within the 24-hour postflight period, crewmembers were also asked to (1) evaluate their perceived motion sickness symptoms on a 20-point scale before and after completion of the test and (2) estimate how heavy they felt compared to their normal (preflight) body weight. Consent to participate in PFT was obtained from 18 crewmembers (11 US Orbital Segment [USOS] astronauts and 7 Russian cosmonauts). For 10 subjects, the first set of data was collected in the medical tent in Soyuz landing zone (1-2 hours after landing); the other 8 subjects were tested at the Kazakhstan deployment airport (4-5 hours after landing). 8 of the 11 astronauts were tested twice more within the first 24 hours postflight, at a refueling stop on the way to Houston (approximately 13 hours after landing) and at the Johnson Space Center (approximately 24 hours after landing). Later postflight data were collected in the first two weeks on some crewmembers. Finally, 6 astronauts were tested 60+ days after landing to establish a delayed baseline. RESULTS/DISCUSSION: Two of the 18 PFT participants felt too ill to attempt any tests in Kazakhstan (at either the landing zone or deployment airport). The remaining test subjects completed the Sit-to-Stand test and their reported motion sickness scores were unaffected by this task. The task completion times and body kinematics data analysis are currently underway. Preliminary analysis of astronaut data shows a steep improvement in the time to complete the task on the second data take, and in some cases, the trend continues through day six postflight. Head and trunk pitch angles and pitch rates were also examined and increases in all measures are evident throughout the observed recovery period (60+ days postflight). Interesting patterns of head and trunk pitch coordination have also emerged. One of the data analysis objectives is comparison of initial postflight performance and recovery of experienced crewmembers and first-time fliers. Another one - possible differences in performance between USOS and Russian crewmembers.

Kofman, I. S.↗

Wireless Chemical Sensing Method

A wireless chemical sensor includes an electrical conductor and a material separated therefrom by an electric insulator. The electrical conductor is an unconnected open-circuit shaped for storage of an electric field and a magnetic field. In the presence of a time-varying magnetic field, the first electrical conductor resonates to generate harmonic electric and magnetic field responses. The material is positioned at a location lying within at least one of the electric and magnetic field responses so-generated. The material changes in electrical conductivity in the presence of a chemical-of-interest.

Woodard, Stanley E.↗

Wireless Temperature Sensing Method Using no Electrical Connections

A wireless temperature sensor includes an electrical conductor and a material spaced apart from the conductor and located within one or more of the responding electric field and responding magnetic field of the conductor. The conductor is electrically unconnected and is shaped for storage of an electric field and a magnetic field. In the presence of a time-varying magnetic field, the conductor resonates to generate harmonic electric and magnetic field responses, each of which has a frequency associated therewith. The material is selected such that it experiences changes in one of dielectric properties and magnetic permeability properties in the presence of a temperature change. Shifts from the sensor's baseline frequency response indicate that the material has experienced a temperature change.

Woodard, Stanley E.↗

Marsbee - Swarm of Flapping Wing Flyers for Enhanced Mars Exploration: NASA Innovative Advanced Concepts (NIAC) - Phase I: Final Report

Mars exploration has received significant interest from academia, industry, government, and the general public. Despite continued interest, flying on Mars remains challenging, mainly due to the ultra-thin Martian atmospheric density. Although the gravitational acceleration on Mars is 38 percent of Earth's 9.8 meters per second squared, the Martian atmospheric density is only 1.3 percent of the air density on Earth. The aerodynamic forces are proportional to the ambient fluid density. Therefore, flying near the surface of Mars has been considered nearly impossible. The proposed mission architecture (Fig. 1) consists of a Mars rover (already existing) that serves as a mobile base for Marsbees - a deployable swarm of small bio-inspired flapping wing vehicles. In one ConOps scenario, each Marsbee would carry an integrated stereographic video camera and the swarm could construct a 3D topographic map of the local surface for rover path planning. These flying scouts would provide a "third-dimension" to the rover capabilities. In other scenarios, each part of the swarm of Marsbees could carry pressure and temperature sensors for atmospheric sampling, or small spectral analyzers for identification of mineral outcroppings. In each scenario, the rover acts as a recharging and deployment/return station and data and communication hub. Human exploration of Mars is one of the major objectives of NASA and commercial entities such as SpaceX and Boeing. The identified innovations unique to the bio-inspired flapping Marsbee provide viable multi-mode flying mobility for Martian atmospheric and terrain exploration. A swarm of Marsbees provides an enhanced reconfigurable Mars exploration system that is resilient to individual component failures. These Marsbees can carry sensors and wireless communication devices in combination with a Mars rover and helicopters. These enhanced sensing and information gathering abilities can contribute to the following NASA Mars mission objectives: i) "Determine the habitability of an environment", ii) "Obtain surface weather measurements to validate global atmospheric models", and iii) "Prepare for human exploration on Mars." Various commercial entities, e.g. SpaceX and Boeing, are investing in technologies to transport humans to Mars.

Kang, Chang-kwon↗

TPSAS-NF1676L-12156-DND

The IVHM project recommends nine priorities for future IVHM research. Strain measurement technology is one of the nine recommendations. The Decadal Survey of Civil Aeronautics: Foundation for the Future, identified IVHM as the top NASA and national priority within the area of materials and structures. The survey also identified IVHM systems that warrant attention over the next decade such as “locally self-powered, wireless microelectromechanical sensors of various types tiny enough that very large numbers of sensors become practical.” Standard strain gages have been used to detect cracks in aircraft, and have been used to monitor load conditions and fatigue in airframes. High temperature devices will be able to monitor structural health in areas that are inaccessible today.

Cy Wilson↗

Remotely powered line monitor

Improved devices, apparatuses, systems, and methods involving the use of field probes with voltage-controlled variable impedance elements and surface-launched acoustic wave devices, including surface acoustic wave (SAW) devices and SAW sensor-tag wireless interface devices to measure voltage and current in current carrying conductors (CCCs) via measurement of the electric fields and magnetic fields around said CCCs are disclosed. The devices, apparatuses, systems, and methods taught in the present invention include a remotely powered line-mounted measurement unit that requires no connection to electrical ground for operation, and that has no internal energy source, no energy harvesting or power conditioning circuitry, no discrete energy storage components, and no radio. The devices, apparatuses, systems, and methods taught in the present invention also provide for determining the phase (leading or lagging) of the current relative to the voltage in AC power systems, and also provide for measurement of temperature of the conductor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Output Current Estimation and Control in Primary Side LCC Secondary Side Series Compensated Wireless Power Transfer System without Secondary Side Sensors

The estimation (and control) of the output variables is often challenging for wireless power transfer (WPT) systems. This paper presents a secondary side sensor-less closed loop estimation technique to estimate the output current in a primary side LCC and secondary side series compensated WPT system. Using information of primary side variables, the proposed estimation can estimate the output current over a wide range of load current variations. Results are presented to verify the efficacy of the proposed estimation.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)↗

Wireless Instrumentation Use on Launch Vehicles

This slide presentation reviews the results of a study on the use of wireless instrumentation and sensors on future launch vehicles. The use of wireless technologies would if feasible would allow for fewer wires, and allow for more flexibility. However, it was generally concluded that wireless solutions are not currently ready to replace wired technologies for launch vehicles. The recommendations of the study were to continue to use wired sensors as the primary choice for vehicle instrumentation, and to continue to assess needs and use wireless instrumentation where appropriate. The future work includes support efforts for wireless technologies, and continue to monitor the development of wireless solutions.

Sherman, Aaron↗

Monitoring of bacteria growth using a wireless, remote query resonant-circuit sensor: application to environmental sensing

A new technique is presented for in-vivo remote query measurement of the complex permittivity spectra of a biological culture solution. A sensor comprised of a printed inductor-capacitor resonant-circuit is placed within the culture solution of interest, with the impedance spectrum of the sensor measured using a remotely located loop antenna; the complex permittivity spectra of the culture is calculated from the measured impedance spectrum. The remote query nature of the sensor platform enables, for example, the in-vivo real-time monitoring of bacteria or yeast growth from within sealed opaque containers. The wireless monitoring technique does not require a specific alignment between sensor and antenna. Results are presented for studies conducted on laboratory strains of Bacillus subtilis, Escherichia coli JM109, Pseudomonas putida and Saccharomyces cerevisiae.

Non-NASA Center↗

Wireless Interrogation of a High Temperature Antenna Sensor Without Electronics

This paper presents a novel interrogation mechanism for an antenna sensor subjected to high temperatures. In sensor node, an Ultra-wide Band (UWB) microstrip antenna was used as a wireless Tx/Rx transceiver to amplify the reflected interrogation signal from the temperature-sensing element, i.e. the patch antenna-sensor. A microstrip delay line was used to connect the Tx/Rx antenna and the antenna-sensor so that the reflected signal from the sensor node is delayed and can be separated from the background clutter using time-domain (T-D) gating technique. In this paper, the principle of operation of the proposed interrogation mechanism is first discussed, followed by the design and simulations of the sensor node circuitry. Finally, a temperature test was conducted to validate the wireless temperature sensing performance of the antenna sensor.

Tchafa, Franck Mbanya↗

Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

Simons, Rainee N.↗