Search NASA⌕ Search

SEARCH · Search NASA

Results for “'Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Gravitational wave measurement in the mid-band with atom interferometers

Abstract Gravitational Waves (GWs) have been detected in the ∼ 100 Hz and nHz bands, but most of the gravitational spectrum remains unobserved. A variety of detector concepts have been proposed to expand the range of observable frequencies. In this work, we study the capability of GW detectors in the “mid-band”, the ∼ 30 mHz– 10 Hz range between LISA and LIGO, to measure the signals from and constrain the properties of ∼ 1 – 100M ⊙ compact binaries. We focus on atom-interferometer-based detectors. We describe a Fisher matrix code,AIMforGW, which we created to evaluate their capabilities, and present numerical results for two benchmarks: terrestrial km-scale detectors, and satellite-borne detectors in medium Earth orbit. Mid-band GW detectors are particularly well-suited to pinpointing the location of GW sources on the sky. We demonstrate that a satellite-borne detector could achieve sub-degree sky localization for any detectable source with chirp mass ℳ c ≲ 50M ⊙ . We also compare different detector configurations, including different locations of terrestrial detectors and various choices of the orbit of a satellite-borne detector. As we show, a network of only two terrestrial single-baseline detectors or one single-baseline satellite-borne detector would each provide close-to-uniform sky-coverage, with signal-to-noise ratios varying by less than a factor of two across the entire sky. We hope that this work contributes to the efforts of the GW community to assess the merits of different detector proposals.

Astronomy & Astrophysics↗

Response of interferometers to the vacuum of quantum gravity

It has recently been suggested that exotic quantum gravity effects could lead to large vacuum fluctuations, potentially observable with realistic detectors. Experiments are currently being built to search for these signals. Here we analyze the minimal model of quantum gravity at low energies—the usual effective quantum field theory of gravitons—and show that it unambiguously predicts an unobservably small variation in the measured interferometer length Δ⁢𝐿 ∼ ℓ pl ∼ 10 −35 m. In particular, there are no divergences signaling a breakdown of this calculation in the low energy regime. Thus, detection of a large, gravitationally induced length variation would signal a severe breakdown of effective quantum field theory in low energy quantum gravity.

Carney, Daniel [Lawrence Berkeley National Laborat↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Vibration Studies for the CLARA Interferometer

The purpose of the CLARA experiment is to study the nature of undulator radiation emitted by single electrons circulating in the IOTA storage ring. The classical and quantum properties of the radiation are investigated by measuring its coherence length, intensity fluctuations and time correlations. The experiment took data in IOTA Run 4 (2022-2023). The key component of the apparatus is a Mach-Zehnder interferometer (MZI), in which the optical length of one of the arms can be precisely controlled. For some measurements, the fine regulation of the arm length must be smaller than the radiation wavelength. For this reason, the apparatus is particularly sensitive to mechanical vibrations. In this note, we model and measure the effect of vibrations on the performance of the MZI under various conditions. Several improvements of the setup were implemented to minimize systematic distortions of the observed interference patterns. In this report, we present a mathematical model of the effect of mechanical vibrations on observed detector and coincidence rates. We also describe the measurements that were made to estimate the magnitude and spectra of rate fluctuations and their sources in the CLARA MZI under various conditions. Finally, we estimate the magnitude of arm length fluctuations and we deduce the sensitivity to coincidence-rate variations in our apparatus.

43 PARTICLE ACCELERATORS↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Requirements for probing chiral Casimir-Polder forces in a molecular Talbot-Lau interferometer

We theoretically investigate the influence of chiral Casimir-Polder (CP) forces in Talbot-Lau interferometry, based on three nanomechanical gratings. We study scenarios where the second grating is either directly written into a chiral material or where the nanomask is coated with chiral substances. We show requirements for probing enantiospecific effects in matter-wave interferometry in the transmission signal and the interference fringe visibility, which depend on the de Broglie wavelength and the molecular chirality. The proposed setup is particularly sensitive to CP forces in the nonretarded regime where chiral effects can be comparable in magnitude to their electric and magnetic counterparts. While the first and third gratings do not change the phase of the matter wave, applying a coating of chiral substances to them enhances the instrument's chiral selectivity. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Multiloop and multiaxis atomtronic Sagnac interferometry

We report the experimental realization of a large-area and multiaxis atomtronic interferometer in an optical waveguide for rotation sensing. A large enclosed area is achieved through multiloop operation in a guided-atom interferometer using Bose-Einstein condensates. We demonstrate a three-loop interferometer with a total interrogation time of ∼ 0.4 s and an enclosed area of 8.7 mm 2 —the largest reported in a fully guided or one-dimensional setup. High-contrast interference fringes are observed for up to five Sagnac orbits in a smaller loop-area configuration. Our approach enables interleaved rotation measurements about multiple arbitrary axes within the same experimental setup. We present results for area-enclosing interferometers in both horizontal and vertical planes, demonstrating that the interferometer contrast remains comparable across orthogonal orientations of the enclosed area vectors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Feynman diagrams for matter wave interferometry

We introduce a new theoretical framework based on Feynman diagrams to compute phase shifts in matter wave interferometry. The method allows for analytic computation of higher order quantum corrections, beyond the traditional semi-classical approximation. These additional terms depend on the finite size of the initial matter wavefunction and/or have higher order dependence on ℏ. We apply the method to compute the response of matter wave interferometers to power law potentials and potentials with an arbitrary spatial dependence. The analytic expressions are validated by comparing to numerical simulations, and estimates are provided for the scale of the quantum corrections to the phase shift response to the gravitational field of the earth, anharmonic trapping potentials, and gravitational fields from local proof masses. We also find that for certain experimentally feasible parameters, these corrections are large enough to be measured and could lead to systematic errors if they are not mitigated. We find that to first order in a spatially dependent potential, quantum corrections vanish when the initial matter wavepacket has spherical symmetry and the potential satisfies Laplace's equation. We anticipate these quantum corrections will be especially important for trapped matter wave interferometers and for free-space matter wave interferometers in the presence of proof masses. These interferometers are becoming increasingly sensitive tools for mobile inertial sensing, gravity surveying, tests of gravity and its interplay with quantum mechanics, and searches for dark energy.

Glick, Jonah [Northwestern U.; Fermilab] (ORCID:00↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗