Search NASA⌕ Search

SEARCH · Search NASA

Results for “(S)TEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Understanding and quantifying electron beam effects during in situ TEM nanomechanical tensile testing on metal thin films

Transmission electron microscopy (TEM) imaging relies on high energy electrons for atomic scale resolution, however, the electrons themselves interact with and may alter the material being imaged. Using an in situ TEM MEMS-based nanomechanical testing technique, the effect of the electron beam (e-beam) on the deformation behavior of nanocrystalline Al and ultrafine-grained Au is investigated and quantified. We show that the e-beam enhances plastic deformation, leading to an increase in plastic strain rate and a decrease in true activation volume V* in Al (28 to 21b 3 , with b being the Burgers vector length). The e-beam has a much weaker effect on Au. The e-beam effect is not caused by knock-on damage, but rather an effective temperature increase due to additional atomic fluctuations provided by the e-beam. The effective temperature increase is larger for Al than Au. This e-beam effect does not change the deformation mechanisms, but instead accelerates the stress-driven, thermally activated plastic deformation. These experiments provide insight into the effects of the e-beam on plastic deformation in different metals and underscore the importance of understanding and quantifying these effects for proper interpretation of measured mechanical properties during in situ TEM experiments.

36 MATERIALS SCIENCE↗

Probing the role of local tunnel variations in early-stage lithiation of α-MnO₂ nanowires via in situ TEM

Understanding lithium-ion transport in tunnel-structured manganese oxides is essential for designing high-performance lithium-ion battery electrode materials. Here, we elucidate the early-stage lithiation mechanism of potassium-stabilized α-MnO 2 nanowires using in situ transmission electron microscopy (TEM) coupled with electron energy-loss spectroscopy (EELS), high-resolution TEM (HRTEM), and geometric phase analysis (GPA). Real-time TEM imaging reveals clear volume expansion at the reaction front, while EELS analysis uncovers lithium-ion diffusion far beyond this region, where no visible expansion is observed, indicating fast, defect-assisted transport. GPA and HRTEM analyses show that localized tensile and compressive strain fields, originating from pre-existing local tunnel structural variations, persist after lithiation. The tensile-strained regions enable lithium-ion insertion with minimal lattice distortion, offering additional free volume that facilitates rapid lithium-ion accommodation ahead of the structural transformation. Our results demonstrate a local tunnel variation-mediated fast diffusion pathway that precedes bulk reaction, underscoring the critical role of local strain in enabling early-stage lithium transport. Given the structural versatility of MnO 2 and its ability to accommodate diverse atomic arrangements beyond the well-known tunnel phases (β-, γ-, δ-, λ-, R-phases), our findings highlight the importance of understanding and engineering local structural environments. This work provides fundamental insights into the interplay between defects, strain, and ion dynamics, and presents defect engineering as a promising approach to enhance both rate performance and structural stability in manganese-based cathodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evolution of dislocation loops and voids in post-irradiation annealed ThO 2 : A combined in-situ TEM and cluster dynamics investigation

The effect of isochronal annealing on the evolution of dislocation loop and void population in proton irradiated ThO 2 has been investigated. Post-irradiation annealing in other actinide oxides like UO 2 shows significant loop coarsening. ThO 2 samples were irradiated with 2 MeV protons up to a dose of 0.1 dpa at 600°C. Post-irradiation isochronal annealing was performed at 600, 800, 1000 and 1100°C for 1 h at each temperature using in-situ TEM. Only faulted 1/3<111> type dislocation loops were observed, and their sizes and distribution were characterized. Further, the population of self-interstitial atom (SIA) dislocation loops did not show any significant growth and coarsening. Additionally, nanometric voids were observed at annealing temperatures of 1000 and 1100°C. Using cluster dynamics (CD), we have studied the nucleation and growth of point defects and defect clusters, i.e., SIA prismatic dislocation loops and nanometric and sub-nanometric voids in proton irradiated ThO 2 . The CD model was further utilized to predict the growth and coarsening of loops and voids during isochronal annealing at the experimental and higher temperatures. The model did not predict significant SIA loop growth which closely corresponds to the TEM observations. CD predicted SIA loop coarsening is insignificant even at high annealing temperature of 1500°C because the model only considers the growth of defect clusters by absorption of like point defects, i.e., SIA loops absorb interstitials and voids absorb vacancies, and cannot account for their migration and coalescence due to elastic interaction. The CD model also predicts the evolution of nanometric voids having mean size within the error bounds of TEM observations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Xe Plasma FIB for High-Quality TEM Sample Preparation

Here, a direct comparison between electron transparent transmission electron microscope (TEM) samples prepared with gallium (Ga) and xenon (Xe) focused ion beams (FIBs) is performed to determine if equivalent quality samples can be prepared with both ion species. We prepared samples using Ga FIB and Xe plasma focused ion beam (PFIB) while altering a variety of different deposition and milling parameters. The samples’ final thicknesses were evaluated using STEM-EELS $\textit{t/λ}$ data. Using the Ga FIB sample as a standard, we compared the Xe PFIB samples to the standard and to each other. We show that although the Xe PFIB sample preparation technique is quite different from the Ga FIB technique, it is possible to produce high-quality, large area TEM samples with Xe PFIB. We also describe best practices for a Xe PFIB TEM sample preparation workflow to enable consistent success for any thoughtful FIB operator. For Xe PFIB, we show that a decision must be made between the ultimate sample thickness and the size of the electron transparent region.

47 OTHER INSTRUMENTATION↗

In-situ/operando study of Cu-based nanocatalysts for CO 2 electroreduction using electrochemical liquid cell TEM

The structure of a nanocatalyst during electrocatalytic reactions often deviates from its pristine structure due to intrinsic properties, or physical and chemical adsorption at the catalytic surfaces. Taking Cu-based catalysts for CO 2 electroreduction reactions (CO 2 RR) as an example, they often experience segregation, leaching, and alloying during reactions. With the recent breakthrough development of high-resolution polymer electrochemical liquid cells, in-situ electrochemical liquid cell transmission electron microscopy (EC-TEM) alongside other advanced microscopy techniques, has become a powerful platform for revealing electrocatalysts restructuring at the atomic level. Considering the complex reactions involving electrified solid-liquid interfaces and catalyst structural evolution with intermediates, systematic studies with multimodal approaches are crucial. In this article, we demonstrate a research protocol for the study of electrocatalysts structural evolution during reactions using the in-situ EC-TEM platform. Using Cu and CuAg nanowire catalysts for CO 2 RR as model systems, we describe the experimental procedures and findings. We highlight the platform’s crucial role in elucidating atomic-scale pathways of nanocatalyst restructuring and identifying catalytic active sites, as well as avoiding potential artifacts to ensure unbiased conclusions. Using the multimodal characterization toolbox, we provide the opportunity to correlate the structure of a working catalyst with its performance. Finally, we discuss advancements as well as the remaining gap in elucidating the structural-performance relationship of working catalysts. We expect this article will assist in establishing guidelines for future investigations of complex electrochemical reactions, such as CO 2 RR and other catalytic processes, using the in-situ EC-TEM platform.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-Microtome for the Preparation of TEM Samples from Battery Cathodes

An ultra-microtome method is developed for the preparation of transmission electron microscopy (TEM) specimens from the cathodes of Li-ion battery. Results indicate that the samples prepared with the ultra-microtome method yield atomic resolution imaging from the core area of particles of hundreds to thousands of nanometers. Analysis of the TEM samples prepared with ultra-microtome indicates that no observable structural damage, such as microcracking, is introduced during the cutting process, and the cathodes cut by ultra-microtome exhibit unchanged micro-morphologies compared with the uncut ones. These results demonstrate that ultra-microtome is a promising method for the preparation of TEM specimens and revealing in-depth microstructures of fragile materials such as battery cathodes.

transmission electron microscopy, Sample Preparati↗

Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Cryo-FIB for TEM Investigation of Soft Matter and Beam Sensitive Energy Materials

Primarily driven by structural biology, the rapid advances in cryogenic electron microscopy techniques are now being adopted and applied by materials scientists. Samples that inherently have electron transparency can be rapidly frozen (vitrified) in amorphous ice and imaged directly on a cryogenic transmission electron microscopy (cryo-TEM), however this is not the case for many important materials systems, which can consist of layered structures, embedded architectures, or be contained within a device. Cryogenic focused ion beam (cryo-FIB) lift-out procedures have recently been developed to extract intact regions and interfaces of interest, that can then be thinned to electron transparency and transferred to the cryo-TEM for characterization. Several detailed studies have been reported demonstrating the cryo-FIB lift-out procedure, however due to its relative infancy in materials science improvements are still required to ensure the technique becomes more accessible and routinely successful. Here, we review recent results on the preparation of cryo-TEM lamellae using cryo-FIB and show that the technique is broadly applicable to a range of soft matter and beam sensitive energy materials. We then present a tutorial that can guide the materials scientist through the cryo-FIB lift-out process, highlighting recent methodological advances that address the most common failure points of the technique, such as needle attachment, lift-out and transfer, and final thinning.

36 MATERIALS SCIENCE↗

Computer vision models and advanced TEM imaging for microstructures of irradiated AM316 stainless steels

Advancements were made in automating microscopy-based material characterization, particularly in studying irradiation effects on additively manufactured (AM) materials using machine learning (ML) and computer vision (CV). These automation efforts address the challenges of analyzing complex microstructures, accelerating the detection of irradiation-induced defects. Two CV models were developed at Argonne National Laboratory (ANL) to enhance transmission electron microscopy (TEM) analysis of irradiated AM 316 stainless steel. The first model focused on the detection of irradiation-induced dislocation loops, which contribute to material hardening and embrittlement. These loops, categorized as faulted or perfect, were automatically detected and classified using a Mask R-CNN model trained on TEM images from both in-situ and ex-situ ion irradiation experiments. The model achieved high accuracy, with precision, recall, and F1 scores of 0.839, 0.734, and 0.776, respectively, demonstrating its effectiveness in analyzing dislocation loops in irradiated AM materials. The second CV model was developed to analyze the size and wall thickness of dislocation cells in laser powder bed fusion (LPBF) 316 stainless steel. Using a U-Net++ architecture with EfficientNet as the encoder, the model was trained on TEM images to segment and measure cell size and wall thickness.

36 MATERIALS SCIENCE↗

In-situ TEM investigation of void swelling in nickel under irradiation with analysis aided by computer vision

Understanding the stability of irradiation-induced voids in materials is important for engineering material's swelling behavior under irradiation. In-situ TEM offers a spatial and temporal resolution that is suitable for investigating the evolution of voids under irradiation. However, the in-situ videos have often been too large to be analyzed manually, leaving the valuable data underutilized. For this work, we developed a deep learning-based semantic segmentation model to consistently study the growth and shrinkage of voids in nickel under 1 MeV krypton ion irradiation at various temperatures from 525 °C to 650 °C. With a foil thickness near 100 nm and ion flux of 6.3 × 10 11 ions∙ cm –2 ∙s –1 , the pre-existing voids, which were created beforehand by irradiation at 600 °C to 0.5 dpa, shrank at low temperatures and grew at high temperatures under irradiation, where the transition occurred at 575 °C (~0.5 T M ). The observed stability transition provided new insight for the shrinkage mechanism of voids under irradiation. In addition, an annealing experiment on nickel, previously irradiated at 600 °C to 3 dpa, was performed sequentially at 650 °C to 720 °C to reveal the shrinkage rate of void as a function of temperature and void size. The advantage of combining computer vision and in-situ TEM to obtain comprehensive void evolution was demonstrated.

36 MATERIALS SCIENCE↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗

In-situ TEM observation of shear induced microstructure evolution in Cu-Nb alloy

Phase boundaries in multiphase alloys govern defect interaction and chemical intermixing across different phases during plastic deformation. Dynamic interaction of defects with phase boundaries in multiphase alloys, especially for immiscible alloys, has been topic of significant research interest in recent years. In this work, we describe a novel approach for carrying out in-situ TEM shear deformation to directly observe interfacial microstructural evolution of a Cu-Nb alloy. A unique double shear specimen geometry is microfabricated by a focused ion beam technique to apply shear deformation upon push loading inside the TEM. From the real-time observation, we discover that the phase boundary with a zigzag morphology effectively blocks stacking faults nucleated in a Cu grain from slipping into a Nb grain. Meanwhile, the Cu phase bears the most plastic deformation through slip or twinning mechanisms. This work sheds light on understanding the shear deformation and the behavior of phase boundaries in multiphase alloys during shear deformation.

36 MATERIALS SCIENCE↗

Correlating results from high resolution EBSD with TEM- and ECCI-based dislocation microscopy: Approaching single dislocation sensitivity via noise reduction

High resolution electron backscatter diffraction (HREBSD), an SEM-based diffraction technique, may be used to measure the lattice distortion of a crystalline material and to infer the geometrically necessary dislocation content. Uncertainty in the image correlation process used to compare diffraction patterns leads to an uneven distribution of measurement noise in terms of the lattice distortion, which results in erroneous identification of dislocation type and density. This work presents a method of reducing noise in HREBSD dislocation measurements by removing the effect of the most problematic components of the measured distortion. The method is then validated by comparing with TEM analysis of dislocation pile-ups near a twin boundary in austenitic stainless steel and with ECCI analysis near a nano-indentation on a tantalum oligocrystal. Finally, the HREBSD dislocation microscopy technique is able to resolve individual dislocations visible in TEM and ECCI and correctly identify their Burgers vectors.

36 MATERIALS SCIENCE↗

In situ TEM study of crystallization and chemical changes in an oxidized uncapped Ge 2 Sb 2 Te 5 film

Ge 2 Sb 2 Te 5 (GST-225) has been the most used active material in nonvolatile phase-change memory devices. Understanding the kinetics and dynamics involved in crystallization is critical for the optimization of materials and devices. A GST-225 thin film of 20 nm thickness was prepared by sputtering directly onto a Protochip and left uncapped and exposed to atmosphere for approximately 1 year. Here, early stages of crystallization and growth of the film have been studied inside the TEM from room temperature to 140 °C. The morphological and structural transformations have been studied by a C s -corrected environmental TEM, and images have been recorded using a high-speed low electron dose camera (Gatan K3 IS). The amorphous to crystalline transformation has been observed at ~35 °C. From the large field, high-resolution images obtained using the Gatan K3 IS camera early crystallization can be detected and nucleation rates and growth velocities can be obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the mechanisms of anisotropic dissolution in metal oxides by applying radiolysis simulations to liquid-phase TEM

Iron-based redox-active minerals are ubiquitous in soils, sediments, and aquatic systems. Their dissolution is of great importance for microbial impacts on carbon cycling and the biogeochemistry of the lithosphere and hydrosphere. Despite its widespread significance and extensive prior study, the atomic-to-nanoscale mechanisms of dissolution remain poorly understood, particularly the interplay between acidic and reductive processes. Here, we use in situ liquid-phase-transmission electron microscopy (LP-TEM) and simulations of radiolysis to probe and control acidic versus reductive dissolution of akaganeite (β–FeOOH) nanorods. Informed by crystal structure and surface chemistry, the balance between acidic dissolution at rod tips and reductive dissolution at rod sides was systematically varied using pH buffers, background chloride anions, and electron beam dose. We find that buffers, such as bis-tris, effectively inhibited dissolution by consuming radiolytic acidic and reducing species such as superoxides and aqueous electrons. In contrast, chloride anions simultaneously suppressed dissolution at rod tips by stabilizing structural elements while promoting dissolution at rod sides through surface complexation. Dissolution behaviors were systematically varied by shifting the balance between acidic and reductive attacks. The findings show LP-TEM combined with simulations of radiolysis effects can provide a unique and versatile platform for quantitatively investigating dissolution mechanisms, with implications for understanding metal cycling in natural environments and the development of tailored nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TEM turbulence in simulation and experiment in quasisymmetric and degraded-symmetry configurations of the HSX stellarator

The Helically Symmetric Experiment (HSX) has demonstrated reduced neoclassical transport and flow damping with quasisymmetry, but the difference of turbulent transport between quasisymmetric and degraded-symmetry configurations has not been definitively assessed. Profile analysis presented here shows that anomalous transport at the mid-radius is larger with degraded quasisymmetry when temperature and density profiles are matched. An initial comparison (${T_\mathrm{i}/T_\mathrm{e}} = 1$) between the quasisymmetric and degraded symmetry configurations finds that trapped-electron mode (TEM) turbulence can support larger heat fluxes in the degraded symmetry configuration despite smaller linear growth rates. However, further simulations at the experimental temperature ratio ($T_\mathrm{i}/T_\mathrm{e} = 0.2$) do not reproduce this effect. Experimental measurements of heat transport and density fluctuation amplitude are compared to nonlinear gyrokinetic simulations at the experimental temperature ratio. The heat flux and density fluctuation amplitude in simulation reproduce a substantial dependence on the density gradient, and the simulated heat flux matches measurements within experimental uncertainties, indicating that TEM turbulence is responsible for the anomalous transport at the steep density gradient in HSX.

HSX↗

Nanometer-scale resolution in an ultra-high pressure environmental TEM holder

Environmental Transmission Electron Microscopy gas holders are vital for studying catalyst nanostructures in reactive gases. Although there are existing methods to understand the behavior of catalysts during reaction, a “pressure gap” exists. Pressures of up to 4.5 bar have been demonstrated, but many industrial catalysts operate at 10–100 bar. This work introduces an ultra-high-pressure TEM gas holder designed to bridge this gap. Experiments demonstrate it can safely operate and achieve nanometer-scale resolution (~ 1.5 nm) in an Environmental TEM at pressures up to 27.5 bar. Practical resolution limitations are attributed to contamination and vibration rather than increased gas scatter.

36 MATERIALS SCIENCE↗

In-situ TEM Holder for Ultrafast, Multimodal Imaging

This project developed a prototype in-situ specimen holder product to transmission electron microscope (TEM) users that drastically expand the usability of TEM by combining nanoscale laser excitation and optical signal collection. A commercial prototype has been constructed and a few nanoscale materials characterization experiments have been performed to validate its performance and demonstrate its utility in real scientific studies, for example, in-situ characterization and mapping of defects in the synthesis of nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗