Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Machine Learning Based AFP Inspection: A Tool for Characterization and Integration

Automated Fiber Placement (AFP) has become a standard manufacturing technique in the creation of large scale composite structures due to its high production rates. However, the associated rapid layup that accompanies AFP manufacturing has a tendency to induce defects. We forward an inspection system that utilizes machine learning (ML) algorithms to locate and characterize defects from profilometry scans coupled with a data storage system and a user interface (UI) that allows for informed manufacturing. A Keyence LJ-7080 blue light profilometer is used for fast 2D height profiling. After scans are collected, they are process by ML algorithms, displayed to an operator through the UI, and stored in a database. The overall goal of the inspection system is to add an additional tool for AFP manufacturing. Traditional AFP inspection is done manually adding to manufacturing time and being subject to inspector errors or fatigue. For large parts, the inspection process can be cumbersome. The proposed inspection system has the capability of accelerating this process while still keeping a human inspector integrated and in control. This allows for the rapid capability of the automated inspection software and the robustness of a human checking for defects that the system either missed or misclassified.

Sacco, Christopher↗

WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacement is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging technology may be valuable as physicians try to eliminate radiation-induce fibrosis and improve the therapeutic ratio of cancer radiotherapy. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.

60 APPLIED LIFE SCIENCES↗

A dosimetric evaluation of the Eclipse AAA algorithm and Millennium 120 MLC for cranial intensity-modulated radiosurgery

The aim of this study is to assess the accuracy of a convolution-based algorithm (anisotropic analytical algorithm [AAA]) implemented in the Eclipse planning system for intensity-modulated radiosurgery (IMRS) planning of small cranial targets by using a 5-mm leaf-width multileaf collimator (MLC). Overall, 24 patient-based IMRS plans for cranial lesions of variable size (0.3 to 15.1 cc) were planned (Eclipse, AAA, version 10.0.28) using fixed field-based IMRS produced by a Varian linear accelerator equipped with a 120 MLC (5-mm width on central leaves). Plan accuracy was evaluated according to phantom-based measurements performed with radiochromic film (EBT2, ISP, Wayne, NJ). Film 2D dose distributions were performed with the FilmQA Pro software (version 2011, Ashland, OH) by using the triple-channel dosimetry method. Comparison between computed and measured 2D dose distributions was performed using the gamma method (3%/1 mm). Performance of the MLC was checked by inspection of the DynaLog files created by the linear accelerator during the delivery of each dynamic field. The absolute difference between the calculated and measured isocenter doses for all the IMRS plans was 2.5% ± 2.1%. The gamma evaluation method resulted in high average passing rates of 98.9% ± 1.4% (red channel) and 98.9% ± 1.5% (blue and green channels). DynaLog file analysis revealed a maximum root mean square error of 0.46 mm. According to our results, we conclude that the Eclipse/AAA algorithm provides accurate cranial IMRS dose distributions that may be accurately delivered by a Varian linac equipped with a Millennium 120 MLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Real-Time Microwave Camera at K-Band (24 GHz)

Nondestructive testing (NDT) community has been moving towards effective and robust inspection systems that can provide real-time information about materials, geometrical, structural and mechanical characteristics of composite materials/structures. Moreover, in many applications it is desired to have an image of the structure, after which the information contained in the image is correlated to the above characteristics. Microwave signals penetrate inside of dielectric composite structures and their interaction with the interior of the structure renders critical information for NDT purposes. Subsequently, this information (i.e., magnitude and phase or reflected signal) may be used to produce an image of the interior of the structure revealing potential flaws or anomalies. Image processing and reconstruction techniques may also be incorporated to produce high-resolution images (i.e., synthetic-aperture, back-propagation, etc.). There are several different approaches for designing areal-time microwave camera system. One approach is based on modulated scatterer technique (MST), which is used to tag scattered electric field in a discrete two-dimensional (2D) spatial domain (e.g. a retina) resulting in the 2D magnitude and phase distribution of the scattered electric field which is required for producing an image of a material or structure under inspection. The ability to rapidly modulate resonant slot antennas in such a retina along with using receivers with fast responses provide for real-time image production capability. Design issue and criteria become more challenging at higher frequencies and for a relatively large retina size. This paper presents the basic design and challenges for a microwave camera with a retina size of 6" by 6" operating at a frequency of 24 GHz.

Ghasr, M. T.↗

Lidar Mapping and Surveillance of Nuclear Infrastructure

Wear is unavoidable, whether it occurs in a nuclear facility or abridge on the highway its detection is crucial to preventing the failure of a system. While tools capable of detecting localized damage exist, industry lacks methods to evaluate the health of larger infrastructure. Routine inspection of nuclear facilities must be undertaken to ensure the safety of personnel and proper containment of nuclear materials. Most systems in a nuclear facility are designated as radioactive and confined spaces. To constantly monitor such systems in person would be hazardous but with a remote inspection tool it can be done in a safer and easier way. Lidar: Operates by emitting a laser pulse and looking for the reflected light. Allows user to gain 3D information of the environment. Project Objective: To develop an inspection tool for evaluating the health of large scale infrastructure using Lidar and machine learning. Autonomous Platform + Lidar + Data Fusion + Big Data. Use SLAM to build a 2D map of the environment. Point cloud created by transforming the points between reference frames. Point cloud to Surface: Inherent representation of surface geometry; Difficult to process with conventional techniques. Point cloud to Image: Easily processed by conventional machine learning algorithms. The quantity of data generated will necessitate a big data framework to manage the data for processing. Additional Sensors: Detecting the temperature (a) chemical makeup (b) and radiation emission (c) of a surface could assist in detecting problems. Human inspection can detect irregularities in both physical objects and their point-cloud representations. This is a good indication that mapping nuclear sites using Lidar will provide qualitative insight into the health of the facility. If deep learning can be used to automatically identify problem areas then the completed tool could become an invaluable asset.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LatticeAnalytics: Strut-Level Visualization and Inspection of Additively Manufactured Lattice Structures

Additive manufacturing (AM) is revolutionizing the production of custom components with complex internal geometries, essential for high-performance applications in diverse fields such as medicine and defense. These AM parts optimize strength while minimizing weight by utilizing internal lattice structures consisting of large quantities of small interconnected struts. However, the complexity of these structures, combined with the challenges of using X-ray Computed Tomography (XCT) data, makes validation of part reliability difficult. This ultimately inhibits the development of novel parts for our collaborating material scientists. Here, we introduce LatticeAnalytics, a novel framework specifically designed for visual inspection of defects in these lattice structures. Our framework offers an end-to-end solution that includes the data management of XCT scans, enables remote access for geographically dispersed teams through a web-based dashboard, and incorporates novel visualizations. Our analysis is facilitated by a coarse alignment between the lattice’s nominal model, a spatial graph, and the XCT data. We employ a simple VR-based approach for fast and rough alignment, followed by an offline registration and identification of the struts. With the nodes and struts aligned and identified in the volume, our framework allows querying of subvolumes containing a single strut at multiple resolutions. This avoids computation over the entire lattice and also allow for easy parallelization of down-stream computations, such as strut-specific metrics. To depict a fast overview of the strut quality, we introduce two innovative visual encodings, crucial for our collaborators’ research in creating novel AM parts: the Contour View and the Roughness Map, which depict critical geometrical and surface features of individual struts in standardized two 2D views. We evaluated the integrated system through expert interviews. The feedback confirms the framework’s practicality and its effectiveness in enhancing current inspection workflows. It solves major bottlenecks for our collaborators, ultimately helping them create novel parts with advanced properties.

Miao, Haichao [Lawrence Livermore National Laborat↗

2D-Ising critical behavior in mixtures of water and 3-methylpyridine

The effect of an antagonistic salt on the phase behavior and nanoscale structure of a mixture of D{sub 2}O and 3-methylpyridine was investigated by visual inspection and small-angle neutron scattering (SANS). The addition of the antagonistic salt, namely sodium tetraphenylborate (NaBPh{sub 4}), induces the shrinking of the two-phase region in contrast to the case in which a normal (hydrophilic) salt is added. Below the phase separation point, the SANS profiles cannot be described by the Ornstein-Zernike function owing to the existence of a long-range periodic structure. With increasing salt concentration, the critical exponents change from the values of 3D-Ising and approach those of 2D-Ising. These results suggest that the concentration fluctuation of the mixture of solvents is limited to a quasi two-dimensional space by the periodic structure induced by the adding the salt. The same behaviors were also observed in mixtures composed of water, 3-methylpyridine, and ionic surfactant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessing High-energy, Laser-driven, X-ray Sources as a Technique to Analyse ILW Containers - 18242

The principle concern regarding intermediate level waste (ILW) containers is the internal volumetric expansion due to the formation of corrosion products. To tackle this (via non-destructive testing) the development of a new technique to identify problematic containers was initiated by radiographic imaging and neutron assay of small scale, simulated, nuclear waste packages. This was achieved using a high-energy laser pulse to produce a bright burst of high-energy Bremsstrahlung radiation for imaging and a pulse of thermal energy neutrons for isotopic quantification. The small scale, simulated, nuclear waste packages (typically a quarter of a 28 mm natural uranium penny encased in grout) were produced with corrosion from oxygen and hydrogen rich environments to simulate the potential effects of long term storage. These samples were characterised using electron and ion beam techniques prior to encapsulation to establish the extent of corrosion and sample morphology. The small-scale samples were analysed using high-resolution x-ray tomography (XRT). These 3D pictures identified the corrosion state of the material and the effect on the surrounding grout matrix. These data sets were used as a baseline to compare with the 2D images obtained from the high-energy radiography to ascertain the imaging quality and potential capability of a laser driven inspection system. The study established the non-destructive imaging capability of a high-energy laser driven x-ray source for identifying fine features such as corrosion products on uranium samples encased in grout and cracks, and for penetrative imaging through large thicknesses of grout. In addition, generation of laser-driven neutrons of thermal energy required for active interrogation of uranium isotopes is demonstrated experimentally and simulations of the neutron inspection method are presented, thus paving the way for criticality testing of ILW containers. This current study is single pulse exposure acquisition, but the data can be used to predict the potential capability of a diode-pumped laser-driven system operating at, or above, 10 Hz by utilising, for example, the Dipole laser technology recently delivered by the STFC Central Laser Facility. Such a system will enable 3D tomography of nuclear waste containers and also greatly reduced signal to noise ratio via multiple acquisition and image stacking. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

Elastic-Poroelastic Simulation of Locally Resonant Ultrasound for Aging Li-Metal Batteries

An elastic-poroelastic simulation of ultrasound inspection for lithium-metal batteries is presented and compared to empirical reflection spectra measured during battery cycling. Simulated reflection spectra were obtained using a two-dimensional (2D) plane strain model, comprised of dozens of individual microns-thick layers within a Li-metal pouch cell. The simulated reflection spectra were then compared to ultrasonic reflection spectra measurements taken intermittently during cell cycling. A sensitivity analysis and parameter calibration were performed for the pristine pouch cell simulation prior to cycling, providing a baseline to account for difficult to measure poroelastic material parameters. Then, the reduction in solid Li anode thickness and corresponding growth into a mossy lithium layer was modeled to represent aging conditions. Results from both simulations and empirical inspections show similar trends in through-thickness resonance frequencies due to cell aging.

Battery↗

Analysis of SSME inspection imagery using AI approaches

The automated analysis of SSME injector assemblies has been investigated for the cases of LOX post surface defects and injector-baffle deterioration. Defects are isolated via 2D feature extraction from borescope and camera images; temporal-frequency transforms are then used to create a multiresolution set of feature vectors representing image contents. The potential flaws thus discriminated are then segmented and classified according to known categories. AI is applied in the form of a blackboard architecture that is controlled by a rule-based production system.

Finegan, Michael K., Jr.↗

Modelling grain-scattered ultrasound in austenitic stainless-steel welds: A hybrid model

The ultrasonic inspection of austenitic stainless steel welds can be challenging due to their coarse grain structure, charaterised by preferentially oriented, elongated grains. The anisotropy of the weld is manifested as both a ‘steering’ of the beam and the back-scatter of energy due to the macroscopic granular structure of the weld. However, the influence of weld properties, such as mean grain size and orientation distribution, on the magnitude of scattered ultrasound is not well understood. A hybrid model has been developed to allow the study of grain-scatter effects in austenitic welds. An efficient 2D Finite Element (FE) method is used to calculate the complete scattering response from a single elliptical austenitic grain of arbitrary length and width as a function of the specific inspection frequency. A grain allocation model of the weld is presented to approximate the characteristic structures observed in austenitic welds and the complete scattering behaviour of each grain calculated. This model is incorporated into a semi-analytical framework for a single-element inspection of a typical weld in immersion. Experimental validation evidence is demonstrated indicating excellent qualitative agreement of SNR as a function of frequency and a minimum SNR difference of 2 dB at a centre frequency of 2.25 MHz. Additionally, an example Monte-Carlo study is presented detailing the variation of SNR as a function of the anisotropy distribution of the weld, and the application of confidence analysis to inform inspection development.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shape, metal abundance, chemistry, and origin of chondrules in the Renazzo (CR) chondrite

We used synchrotron X-ray microtomography to image in 3-dimensions (3D) eight whole chondrules in a {approx}1 cm{sup 3} piece of the Renazzo (CR) chondrite at {approx}17 {micro}m per volume element (voxel) edge. We report the first volumetric (3D) measurement of metal/silicate ratios in chondrules and quantify indices of chondrule sphericity. Volumetric metal abundances in whole chondrules range from 1 to 37 volume % in 8 measured chondrules and by inspection in tomography data. We show that metal abundances and metal grain locations in individual chondrules cannot be reliably obtained from single random 2D sections. Samples were physically cut to intersect representative chondrules multiple times and to verify 3D data. Detailed 2D chemical analysis combined with 3D data yield highly variable whole-chondrule Mg/Si ratios with a supra-chondritic mean value, yet the chemically diverse, independently formed chondrules are mutually complementary in preserving chondritic (solar) Fe/Si ratios in the aggregate CR chondrite. These results are consistent with localized chondrule formation and rapid accretion resulting in chondrule + matrix aggregates (meteorite parent bodies) that preserve the bulk chondritic composition of source regions.

43 PARTICLE ACCELERATORS↗

R and DE Robotic Sensor Intern Team: Advanced Sensor Suite Prototype

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel is an example of such an environment where a biannual inspection is currently performed. Presently inspections are performed by teleoperated robotic crawlers which provide low-res video feedback to the structural engineers. Advanced sensors: including Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. Possible sensors were a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The Hokuyo UTM-30LX-EW shown below provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. Along with the Lidar, a camera sensor, IMU sensor, pan-tit unit, and on board computer needed to be identified. The two panospheric cameras allow for full 360 deg. FOV. The IMU will give data on the state of the robot inside the tunnel. The computer is used to gather and process data on board and to control the pan-tilt system. Mounts were designed and 3D printed to build the prototype of the sensor suite. It was designed to have the Lidar on top With its full FOV free while having the camera below and as close to together as possible while still leaving much of their FOV visible. The design also managed the cables such that they were unlikely to be damaged if in tension and so that they did not intrude much on the cameras vision. The sensor tree developed for the H-Canyon tunnel inspection project produces a large quantity of camera and Lidar data. a postprocessing pipeline was created to facilitate the analysis of these data. The pipeline follows the following routine: 1) Registration - Salient local features in subsequent scans are identified and used to align the scans With one another. This allows production of a single cohesive map of the tunnel. 2) Sensor Fusion - RGB camera data is 'painted' onto the depth data created by the Lidar. 3) Segmentation - Individual surfaces from within the scene are segmented out separately for individual analysis. 4) Degradation Analysis - Automatic mapping of local deviation from the plane in position or surface normal is performed, as is detection of exposed rebar using Lidar return intensity. 2) Obstacle Detection - Lidar data is also used in real time to detect obstacles in the environment. This could give feedback to the operator to successfully drive in the tunnel. 6) Graphic User Interface - a custom GUI was created to facilitate customer use of the system. The system provides real-time feedback from both the cameras and Lidar. The Lidar point-cloud data is also used for obstacle detection. As the Lidar spins, various algorithms are run to analyze the current 'slice' and obstacles in the environment are determined and registered on a cost-map. A Graphical User Interface (GUI) was developed to allow the user to easily command the crawler to set the rotational speed of the Lidar, perform a scan, and register and save the 3D generated cloud after a scan is done. For the good of the crawler, a critical aspect of the GUI design is to allow the user to cancel a scan any time after it is commanded and before it is saved. The sensor trees depth accuracy was evaluated in comparison to a high end commercial FARO Terrestrial Laser Scanner (TLS) with specifications for millimeter accuracy at distances above 10 m. For the purposes of these tests, the depth measurements produced by the TLS were taken as ground truth. Example test wall panels were scanned with the TLS and postprocessed with its proprietary software, and subsequently scanned with the sensor tree system. The two scans were manually aligned and for each point in the output cloud from the sensor tree, the distance to the nearest ground truth point in the FARO cloud was determined. 98.7% of all produced points were within the specified target range of 6 mm, with an average deviation of 1.75 mm. The test walls used have an overall in-wall depth variation of around 40 mm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-C-9A-07: Fabrication and Calibration of a Novel High-Sensitivity Collimator for Brain SPECT Imaging

Purpose: We have designed a novel collimator for brain SPECT imaging that yields greatly increased sensitivity near the center of the brain without loss of resolution. The collimator was manufactured and initial evaluation has been completed. Methods: The collimator was time-consuming and challenging to build. Because our desired hole pattern required substantial variations in hole angle, we designed two supporting plates to securely position about 34,000 hexagonal, slightly tapered, 75-mm long steel pins. The holes in the plates were modeled to yield the desired focal length, hole length and septal thickness. Molten lead was poured in between the plates, and all pins were removed after cooling. The sensitivity gain compared to a fan-beam collimator was measured using a point source placed along the central ray at several distances from the collimator face. Visual inspection of the holes was not possible as the collimator was sealed so it could be safely mounted on a SPECT system. Therefore, we prepared a 2D array of 768, ∼48μCi Tc-99m point sources, separated by 1.6 cm. The array was imaged for 10 minutes at 4 shifted locations to reduce sampling distance to 8 mm. Results: The sensitivity of the novel cone-beam collimator varied with distance from the detector face; it was higher than that of the fan-beam collimator by factors ranging from 3 to 176. Examination of the projections of the 4×768 point sources revealed that fewer than 2% of the holes were fully or partially blocked, which indicates that the intensive manual fabrication process was very successful. Conclusion: We have designed and manufactured a novel collimator for brain SPECT imaging. As expected, the sensitivity is much higher than that of a fan-beam collimator. Because of differences between the manufactured collimator and its design, reconstruction of the data will require a measured system function.

60 APPLIED LIFE SCIENCES↗

NMF-Based Anomaly Detection in CMS 2D Tracking Occupancy Histograms

The CMS experiment relies on Data Quality Monitoring (DQM) to ensure that recorded collision data are suitable for physics analysis. During LHC Run 3, each run contains many lumisections and tracking monitoring elements, making offline inspection challenging, especially for localized detector effects that may appear only for short periods of time. This poster presents an unsupervised machine-learning approach to identify anomalous lumisections in CMS tracking occupancy histograms using Non-Negative Matrix Factorization (NMF). The workflow uses offline CMS DQMIO tracking histograms retrieved with the CMS DIALS API and organized as two-dimensional occupancy maps for each lumisection. After selecting stable lumisections, the occupancy maps are normalized and arranged into a non-negative data matrix. The NMF model learns a compact set of basis patterns describing normal tracking occupancy. Each lumisection is then reconstructed from these learned components, and the reconstruction error is used as an anomaly score. Large residuals indicate occupancy patterns that deviate from normal detector behavior and are flagged for further inspection. This NMF-based approach provides a fast and interpretable way to flag lumisections whose tracking occupancy patterns differ from normal detector behavior. Preliminary studies show sensitivity to known tracking anomalies, and ongoing work is focused on validating the method across additional Run 3 Pixel and Strip detector issues.

Rodríguez Ramos, Iliomar [Puerto Rico U., Mayaguez↗

Automated eddy current inspection of Space Shuttle APU turbine wheel blades

An automated inspection system based on eddy current testing (ET) techniques has been developed to inspect turbine wheel blades on the APU used in NASA's Space Transportation system. The APU is a hydrazine-powered gas turbine with a 15-cm diameter Rene 41 turbine wheel, which has 123 first-stage blades and 123 second-stage blades. The flaw detection capability of the ET system is verified through comparison with fluorescent penetrant test results. Results of the comparison indicate that ET is capable of inspecting surfaces with very restrictive geometries. The ET capability requires development of probes with extremely small coils to allow inspection within 0.4 mm of the blade root and the leading and trailing edges of the blade and within a height restriction of less than 1 mm. The color 2D presentation of the ET data provided crack-growth pattern and length information similar to those found with visual techniques. It also provided visual clues to minimize geometry effects such as generated from blade edges, a neighoring blade, and changes in the blade thickness.

Fisher, Jay L.↗