Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

System and method for adaptive range 3D scanning

A scanner system is configured for acquiring three dimensional image information of an object. The scanner includes a projector, a camera, a graphics processing device, and a processor. The projector projects one of several pre-defined patterns upon the object. The camera captures an image from the object, which is received by the processor. The processor approximates mutual information from the object and the pattern using the graphics processing device, and selects a second pattern for projecting on the object.

Rosman, Guy↗

High-speed wide-angle interleaved scanning technique for a 3D imaging lidar

In this paper, we describe a novel interleaved scanner for an eye-safe 3D scanning lidar system to measure aerodynamic phenomena in a wind tunnel using elastic backscatter from seeding particles. The scanner assembly consists of a rotating polygon scanner for line scanning along the fast axis, a galvanometer (galvo) scanner for scanning along the slow axis, angular position sensors and motor controllers. The polygon scanner sweeps the lidar beam at up to 10,000 lines/s across a 27 deg angular field-of-regard in the fast axis, while the galvo scanner covers an angular range of 20 deg in the slow axis. Using this scanner, the lidar can perform non-intrusive flow visualization, velocimetry, and hard target mapping at mmscale spatial resolution to a standoff range of 5 m at an update rate of 50 Hz for the full field-of-regard. An interleaved scanning methodology for the acquisition of two snapshots of 3D lidar intensity data with a 100 μs time offset is discussed. The design of the control and data acquisition electronics is described. The effects of rapid scanning on the response of a narrow field-of-view lidar are addressed. The design of the scanner is scalable and can be tailored to meet the requirements of other applications by increasing or decreasing the standoff range, angular field-of-regard and scan rate.

3D Imaging Lidar↗

TU-H-BRC-01: A New Fabrication Method for Secondary Skin Collimation Using 3D Scanner and 3D Printer

Purpose: Using secondary skin collimation (SSC) to protect the critical organ surrounding the tumors is always desirable for electron and/or ortho-voltage treatments. However, the time-consuming and labor-intensive fabrication processes of current method (manually fabricate the lead mask) restrict the general use of SSC. The aim of this study is to develop a new SSC fabrication method using 3D scanning and 3D printing technologies in order to largely decrease the human labor involvement and fabrication time, also improve the fabrication accuracy. Methods: First, the patient surface was scanned with a 3D scanner (Structure Sensor, Occipital, CO). The raw scan data was subsequently transferred to a 3D modeling software (Rhinoceros, Ver. 5.0, McNeel North America, Seattle, WA). The tumor contour was then digitized and shielding region was determined by clinicians in the same software. The corresponding SCC conformed to the skin surface was then automatically generated by the software with the proper shielding thickness. The shell of the SCC (with hollow inside) was consequently printed by a 3D printer (Lulzbot TAZ, Aleph Objects, CO) using plastic material. Finally, the hollow mold of SCC was filled up with a melted cerrobend alloy. Once the cerrobend alloy cooled down, the fabrication of SCC was accomplished. Results: The results indicated the proposed method can achieve a much shorter time on making a SCC compared with tradition fabrication method. The processes of making a skin contour model for patients have been eliminated with the new method. SCC created by the new method possessed better accuracy and better conformality to patient’s skin contours. Conclusion: In this study, we have demonstrated a new method for the SCC fabrication. It is anticipated that our method can be an alternative way to replace conventional manual-based methods for electron and/or ortho-voltage SCC fabrication. This research was supported by the Global Ph.D. Fellowship Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (Grant No. 2015H1A2A1034071), Republic of Korea.

60 APPLIED LIFE SCIENCES↗

Can fractal dimensions objectivize gastropod shell morphometrics? A case study from Lake Lugu (SW China)

1. Morphometrics are fundamental for the analysis of size and shape in fossils, particularly because soft parts or DNA are rarely preserved and hard parts such as shells are commonly the only source of information. Geometric morphometrics, that is, landmark analysis, is well established for the description of shape but it exhibits a couple of shortcomings resulting from subjective choices during landmarking (number and position of landmarks) and from difficulties in resolving shape at the level of micro-sculpture. 2. With the aid of high-resolution 3D scanning technology and analyses of fractal dimensions, we test whether such shortcomings of linear and landmark morphometrics can be overcome. As a model group, we selected a clade of modern viviparid gastropods from Lake Lugu, with shells that show a high degree of sculptural variation. Linear and landmark analyses were applied to the same shells in order to establish the fractal dimensions. 3. The genetic diversity of the gastropod clade was assessed. The genetic results suggest that the gastropod clade represents a single species. The results of all morphometric methods applied are in line with the genetic results, which is that no specific morphotype could be delimited. Apart from this overall agreement, landmark and fractal dimension analyses do not correspond to each other but represent data sets with different information. Generally, the fractal dimension values quantify the roughness of the shell surface, the resolution of the 3D scans determining the level. In our approach, we captured the micro-sculpture but not the first-order sculptural elements, which explains that fractal dimension and landmark data are not in phase. 4. We can show that analyzing fractal dimensions of gastropod shells opens a window to more detailed information that can be considered in evolutionary and ecological contexts. We propose that using low-resolution 3D scans may successfully substitute landmark analyses because it overcomes the subjective landmarking. Analyses of 3D scans with higher resolution than used in this study will provide surface roughness information at the mineralogical level. We suggest that fractal dimension analyses of a combination of differently resolved 3D models will significantly improve the quality of shell morphometrics.

54 ENVIRONMENTAL SCIENCES↗

Laser Ultrasound Spectroscopy Scanning for 3D Printed Parts

One of the challenges of additive manufacturing is quality control due to the possibility of unseen flaws in the final product. The current methods of inspection are lacking in detail, too slow for practical use, or unable to validate internal structure. This report examines the use of laser ultrasound spectroscopy in layer by layer scans of 3D printed parts as they are created. The result is fast and detailed quality control. An additional advantage of this method is the ability to cancel a print as soon as a defect is detected, therefore saving materials and time. This technique, though simple in concept, has been a challenge to implement. I discuss tweaking the 3D printer configuration, and finding the optimal settings for laser scanning small parts made of ABS plastic, as well as the limits of how small of a detail the laser can detect. These settings include the frequency of the ultrasonic transducer, the speed of the laser, and the distance from the laser to the part.

47 OTHER INSTRUMENTATION↗

Application of Pinniped Vibrissae to Aeropropulsion

Vibrissae of Phoca Vitulina (Harbor Seal) and Mirounga Angustirostris (Elephant Seal) possess undulations along their length. Harbor Seal Vibrissae were shown to reduce vortex induced vibrations and reduce drag compared to appropriately scaled cylinders and ellipses. Samples of Harbor Seal vibrissae, Elephant Seal vibrissae and California Sea Lion vibrissae were collected from the Marine Mammal Center in California. CT scanning, microscopy and 3D scanning techniques were utilized to characterize the whiskers. Computational fluid dynamics simulations of the whiskers were carried out to compare them to an ellipse and a cylinder. Leading edge parameters from the whiskers were used to create a 3D profile based on a modern power turbine blade. The NASA SW-2 facility was used to perform wind tunnel cascade testing on the 'Seal Blades'. Computational Fluid Dynamics simulations were used to study incidence angles from -37 to +10 degrees on the aerodynamic performance of the Seal Blade. The tests and simulations were conducted at a Reynolds number of 100,000. The Seal Blades showed consistent performance improvements over the baseline configuration. It was determined that a fuel burn reduction of approximately 5 could be achieved for a fixed wing aircraft. Noise reduction potential is also explored.

wakes↗

Characterization and Analysis of Phoca Vitulina, Zalophus Californianus and Mirounga Angustirostris Vibrissae

Vibrissae of Phoca Vitulina (harbor seal) and Mirounga Angustirostris (elephant seal) possess undulations along their length. Harbor seal vibrissae have shown potential to reduce vortex induced vibrations and reduce drag compared to cylinders and ellipses. The exact geometry of the whiskers has not been well documented and the parameters that are responsible for the reduction in drag and vortex induced vibrations have not been characterized. Samples of six harbor seal vibrissae, six elephant seal vibrissae and six California sea lion (Zalophus californianus) vibrissae were collected from the Marine Mammal Center in California. The objectives of this study were to (1) Compare measurement techniques for digitizing and extracting parameters of the seal whiskers for the PeTaL (Periodic Table of Life) database. CT scanning, microscopy and 3D scanning techniques were compared. (2) Compare aerodynamic characteristics of a representative harbor seal whisker, elephant seal whisker, California sea lion whisker and ellipse at Re = 12000 and Re = 23000 based on major axis and free stream velocity. The data (in appendices) is available to compare CFD models or for further experimental validation, (3) Show close up images of whiskers and look for surface roughness effects. Variations in the seven parameters of the seal whisker were observed that may either be a feature of the vibration reduction mechanism or a result of natural variation. It is hypothesized that six parameters are sufficient to characterize seal whiskers based on analytic fitting. The drag coefficient of harbor seal whiskers examined in this study were found to be 25 percent lower than that of an ellipse with comparable major and minor axis lengths at Reynolds number of 12000. The dissipation length scale was found to be larger for seal whiskers. Potential applications of seal whisker morphology for aerospace are discussed. Roughness is not thought to play a factor in seal hydrodynamics.

Shyam, Vikram↗

Secondary porosity prediction in complex carbonate reefs using 3D CT scan image analysis and machine learning

Development and preservation of carbonate porosity and permeability are critical to characterizing reservoirs. However, secondary porosity, such as vugs and fractures, are difficult to identify and require collection of expensive wireline tools or core sampling. Wireline logs and cores have traditionally been used to identify the presence of secondary porosity but fail to quantify the contribution to total reservoir porosity. Additionally, advanced wireline logs and core are not readily available for most wells. Dual energy CT scans were collected on whole core from the A-1 Carbonate and Brown Niagaran formations drawn from six wells in northern Michigan. 3D analysis techniques were applied to identify and isolate secondary porosity features. A series of machine learning and data analytics techniques were applied to the dataset to predict secondary porosity features on basic wireline logs. The predictive model successfully predicted secondary porosity with high confidence.

02 PETROLEUM↗

An Imaging System for Automated Characteristic Length Measurement of Debrisat Fragments

The debris fragments generated by DebriSat's hypervelocity impact test are currently being processed and characterized through an effort of NASA and USAF. The debris characteristics will be used to update satellite breakup models. In particular, the physical dimensions of the debris fragments must be measured to provide characteristic lengths for use in these models. Calipers and commercial 3D scanners were considered as measurement options, but an automated imaging system was ultimately developed to measure debris fragments. By automating the entire process, the measurement results are made repeatable and the human factor associated with calipers and 3D scanning is eliminated. Unlike using calipers to measure, the imaging system obtains non-contact measurements to avoid damaging delicate fragments. Furthermore, this fully automated measurement system minimizes fragment handling, which reduces the potential for fragment damage during the characterization process. In addition, the imaging system reduces the time required to determine the characteristic length of the debris fragment. In this way, the imaging system can measure the tens of thousands of DebriSat fragments at a rate of about six minutes per fragment, compared to hours per fragment in NASA's current 3D scanning measurement approach. The imaging system utilizes a space carving algorithm to generate a 3D point cloud of the article being measured and a custom developed algorithm then extracts the characteristic length from the point cloud. This paper describes the measurement process, results, challenges, and future work of the imaging system used for automated characteristic length measurement of DebriSat fragments.

Moraguez, Mathew↗

Revisiting the Hail Radar Reflectivity–Kinetic Energy Flux Relation by Combining T-Matrix and Discrete Dipole Approximation Calculations to Size Distribution Observations

The retrieval of hail kinetic energy with weather radars or its simulation in numerical models is challenging because of the shape complexity and variable density of hailstones. We combine 3D scans of individual hailstones with measurements of the particle size distributions (PSD) and T-matrix calculations to understand how hail reflectivity Z changes when approximating hailstones as spheroids, as compared to the realistic shapes obtained by 3D scanning technology. Additionally, recent terminal velocity relations are used to compare Z to the hail kinetic energy flux E ˙ . We parameterize the hail backscattering cross sections at L, S, C, and X bands as a function of size between 0.5 and 5.0 cm, matching the range of the observed PSDs. The scattering calculations use the T-matrix method for size parameters below 1.0 and the discrete dipole approximation (DDA) method otherwise. The DDA calculations are done for 48 digital models of realistic hailstones of sizes between 1 and 5 cm. The DDA cross sections are calculated for multiple orientations and averaged assuming a fully random orientation distribution to provide a single value per hailstone. The T-matrix reflectivity assuming solid ice spheres presents negligible differences to DDA results for size parameters below 1.0. Therefore, T matrix was used to fill in the gaps left by the DDA calculations. The results are mapped to the same size bins of the observed PSDs, allowing the calculation of the radar reflectivity. This is then correlated to E ˙ , allowing a potential improvement of past retrieval methods of E ˙ from Z in multiple wavelengths.

54 ENVIRONMENTAL SCIENCES↗

Design Visualization Internship Overview

This is a report documenting the details of my work as a NASA KSC intern for the Summer Session from June 2nd to August 8th, 2014. This work was conducted within the Design Visualization Group, a Contractor staffed organization within the C1 division of the IT Directorate. The principle responsibilities of the KSC Design Visualization Group are the production of 3D simulations of NASA equipment and facilities for the purpose of planning complex operations such as hardware transportation and vehicle assembly. My role as an intern focused on aiding engineers in using 3D scanning equipment to obtain as-built measurements of NASA facilities, as well as using CATIA and DELMIA to process this data. My primary goals for this internship focused on expanding my CAD knowledge and capabilities, while also learning more about technologies I was previously unfamiliar with, such as 3D scanning. An additional goal of mine was to learn more about how NASA operates, and how the U.S. Space Program operates on a day-to-day basis. This opportunity provided me with a front-row seat to the daily maneuvers and operations of KSC and NASA as a whole. Each work day, I was able to witness, and even take part of, a small building block of the future systems that will take astronauts to other worlds. After my experiences this summer, not only can I say that my goals have been met, but also that this experience has been the highlight of my experience in higher education.

Telescience↗

Parametric Finite Element Analysis of Naturally Corroded Steel Specimens Using 3D Surface Laser Scans

Corrosion is considered a uniform thickness reduction design guideline of the maritime industry. However, additionally, the corroded and irregular morphology of the surface affects the steel's load-bearing capacity and its impact on the strength and elongation behaviour of the steel is not yet fully understood. These effects on the local behaviour of steel structures under tensile loading were investigated with tensile tests on naturally corroded steel specimens and nonlinear finite element simulations including the corroded surface morphology with a uniform surface idealation. The models also include the deformed specimen shape. The developed approach led to highly accurate parametric finite element models predicting the ultimate tensile strength and longitudinal position of fracture. The results show that all included aspects are essential for accurate simulations, while solely the maximum available surface resolution was not as decisive.

corrosion↗

Retrieval of Boundary Layer 3D Cloud Properties Using Scanning Cloud Radar and 3D Radiative Transfer

Retrievals of cloud optical and microphysical properties for boundary layer clouds, including those widely used by ASR investigators, frequently assume that clouds are sufficiently horizontally homogeneous that scattering and absorption (at all wavelengths) can be treated using one dimensional (1D) radiative transfer, and that differences in the field-of-view of different sensors are unimportant. Unfortunately, most boundary layer clouds are far from horizontally homogeneous, and numerous theoretical and observational studies show that the assumption of horizontal homogeneity leads to significant errors. The introduction of scanning cloud and precipitation radars at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program sites presents opportunities to move beyond the horizontally homogeneous assumption. The primary objective of this project was to develop a 3D retrieval for warm-phase (liquid only) boundary layer cloud microphysical properties, and to assess errors in current 1D (non-scanning) approaches. Specific research activities also involved examination of the diurnal cycle of hydrometeors as viewed by ARM cloud radar, and continued assessment of precipitation impacts on retrievals of cloud liquid water path using passive microwaves.

54 ENVIRONMENTAL SCIENCES↗

3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

Macke, R. J.↗

A New Geometric Method Based on Two-Dimensional Transmission Electron Microscopy for Analysis of Interior versus Exterior Pd Loading on Hollow Carbon Nanofibers

Hallow carbon nanofibers (CNFs) are being explored as catalyst supports because of their unique properties; catalytic activities with both interior and exterior metal loadings are being evaluated. Electron tomography (3D transmission electron microscopy, 3D TEM) has been used to estimate internal versus external loading of metal nanoclusters. However, this method is time consuming and requires a specialized TEM. We prepared three hollow CNF supported Pd samples with various Pd localizations, and developed a geometric analysis method based on 2D TEM images to estimate Pd internal versus external loading percentages. Results show the similar localization for the same sample in terms of the number, surface area, and mass of Pd nanoclusters but distinct values for different samples. To test our method, we compare results for one segment of a CNF using both 3D scanning transmission electron microscopy (3D TEM) and our new 2D geometic analysis method. Agreement is within 15.1%. Our results also agree with 3D TEM results from the literature for similarly prepared Pd on CNFs (within 5.6%). Our geometric analysis method is proposed as a more straightforward and fast way to evaluate metal nanocluster localizations on tubular supports.

2D↗

Morphometric Comparison of Clavicle Outlines from 3D Bone Scans and 2D Chest Radiographs: A Short-listing Tool to Assist Radiographic Identification of Human Skeletons

This paper describes a computerized clavicle identification system, primarily designed to resolve the identities of unaccounted for US soldiers who fought in the Korean War. Elliptical Fourier analysis is used to quantify the clavicle outline shape from skeletons and postero-anterior antemortem chest radiographs to rank individuals in terms of metric distance. Similar to leading fingerprint identification systems, shortlists of the top matching candidates are extracted for subsequent human visual assessment. Two independent tests of the computerized system using 17 field-recovered skeletons and 409 chest radiographs demonstrate that true positive matches are captured within the top 5% of the sample 75% of the time. These results are outstanding given the eroded state of some field-recovered skeletons and the faintness of the 1950’s photoflurographs. These methods enhance the capability to resolve several hundred cold cases for which little circumstantial information exists and current DNA and dental record technologies cannot be applied.

computer assisted↗