Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Single Lens Dual-Aperture 3D Imaging System: Color Modeling

In an effort to miniaturize a 3D imaging system, we created two viewpoints in a single objective lens camera. This was accomplished by placing a pair of Complementary Multi-band Bandpass Filters (CMBFs) in the aperture area. Two key characteristics about the CMBFs are that the passbands are staggered so only one viewpoint is opened at a time when a light band matched to that passband is illuminated, and the passbands are positioned throughout the visible spectrum, so each viewpoint can render color by taking RGB spectral images. Each viewpoint takes a different spectral image from the other viewpoint hence yielding a different color image relative to the other. This color mismatch in the two viewpoints could lead to color rivalry, where the human vision system fails to resolve two different colors. The difference will be closer if the number of passbands in a CMBF increases. (However, the number of passbands is constrained by cost and fabrication technique.) In this paper, simulation predicting the color mismatch is reported.

bipartite filter↗

WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2D and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to enhance quality assurance services and to be consistently adaptive to the new advances in radiation therapy. This project was supported by NCI grants U10CA180868, U10CA180822, U24CA180803, U24CA12014 and PA CURE Grant.

60 APPLIED LIFE SCIENCES↗

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics↗

Single-molecule 3D imaging of HIV cellular entry by liquid-phase electron tomography

Enveloped viruses, including human immunodeficiency virus (HIV) and SARS-CoV-2, target cells through membrane fusion process. The detailed understanding of the process is sought after for vaccine development but remains elusive due to current technique limitations for direct three-dimensional (3D) imaging of an individual virus during its viral entry. Recently, we developed a simple specimen preparation method for real-time imaging of metal dynamic liquid-vaper interface at nanometer resolution by transmission electron microscopy (TEM). Here, we extended this method to study biology sample through snapshot 3D structure of a single HIV (pseudo-typed with the envelope glycoprotein of vesicular stomatitis virus, VSV-G) at its intermediate stage of viral entry to HeLa cells in a liquid-phase environment. By individual-particle electron tomography (IPET), we found the viral surface release excess lipids with unbound viral spike proteins forming ~50-nm nanoparticles instead of merging cell membrane. Moreover, the spherical-shape shell formed by matrix proteins underneath the viral envelope does not disassemble into a cone shape right after fusion. Further, the snapshot 3D imaging of a single virus provides us a direct structure-based understanding of the viral entry mechanism, which can be used to examine other viruses to support the development of vaccines combatting the current ongoing pandemic.

Kong, Lingli↗

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

Dual FIB-SEM 3D imaging and lattice boltzmann modeling of porosimetry and multiphase flow in chalk.

Mercury intrusion porosimetry (MIP) is an often-applied technique for determining pore throat distributions and seal analysis of fine-grained rocks. Due to closure effects, potential pore collapse, and complex pore network topologies, MIP data interpretation can be ambiguous, and often biased toward smaller pores in the distribution. We apply 3D imaging techniques and lattice-Boltzmann modeling in interpreting MIP data for samples of the Cretaceous Selma Group Chalk. In the Mississippi Interior Salt Basin, the Selma Chalk is the apparent seal for oil and gas fields in the underlying Eutaw Fm., and, where unfractured, the Selma Chalk is one of the regional-scale seals identified by the Southeast Regional Carbon Sequestration Partnership for CO2 injection sites. Dual focused ion - scanning electron beam and laser scanning confocal microscopy methods are used for 3D imaging of nanometer-to-micron scale microcrack and pore distributions in the Selma Chalk. A combination of image analysis software is used to obtain geometric pore body and throat distributions and other topological properties, which are compared to MIP results. 3D data sets of pore-microfracture networks are used in Lattice Boltzmann simulations of drainage (wetting fluid displaced by non-wetting fluid via the Shan-Chen algorithm), which in turn are used to model MIP procedures. Results are used in interpreting MIP results, understanding microfracture-matrix interaction during multiphase flow, and seal analysis for underground CO2 storage.

03 NATURAL GAS↗

3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

surgery↗

Synchrotron Radiation Microtomography for Large Area 3D Imaging of Multilevel Microelectronic Packages

3D x-ray computed tomography (CT), using conventional laboratory-based x-ray sources, has been used in the past to image multiple levels of interconnects in 3D microelectronic packages. These conventional x-ray sources can provide high resolution images with throughput times (TPT) of several hours. However, this can only be performed on localized areas of about 1–2 mm 2 , which gravely limits the application of 3D x-ray CT in the field of microelectronic packages with sizes usually in the range of 100–3600 mm 2 . An alternative to laboratory-based x-ray sources is synchrotron radiation, which can produce large area collimated beams for high flux x-ray imaging over a much larger field of view (FOV) than conventional sources. Synchrotrons can potentially image an entire 3D stacked chip package at high resolutions in less than an hour. Here, we present results using the micro-CT line at the advanced light source synchrotron to image an entire 16 × 16 mm system in a package in times as low as 3 min, demonstrating several orders of magnitude increase in the ratio of FOV to TPT as compared to laboratory-based x-ray methods.

42 ENGINEERING↗

Estimation of local stresses and elastic properties of a mortar sample by FFT computation of fields on a 3D image

This study concerns the prediction of the elastic properties of a 3D mortar image, obtained by micro-tomography, using a combined image segmentation and numerical homogenization approach. The microstructure is obtained by segmentation of the 3D image into aggregates, voids and cement paste. Full-fields computations of the elastic response of mortar are undertaken using the Fast Fourier Transform method. Emphasis is made on highly-contrasted properties between aggregates and matrix, to anticipate needs for creep or damage computation. The representative volume element, i.e. the volume size necessary to compute the effective properties with a prescribed accuracy, is given. Overall, the volumes used in this work were sufficient to estimate the effective response of mortar with a precision of 5%, 6% and 10% for contrast ratios of 100, 1000 and 10,000, resp. Finally, a statistical and local characterization of the component of the stress field parallel to the applied loading is carried out.

36 MATERIALS SCIENCE↗

Enhanced FIB-SEM systems for large-volume 3D imaging

Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33{+-}0.16 mm (s.d.) in overall translation and 0.29 deg. {+-}0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34{+-}0.16 mm (s.d.), 0.40{+-}0.2 mm (s.d.), and 0.51{+-}0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic 3D image registration for nano-resolution chemical mapping using synchrotron spectro-tomography

Nano-resolution synchrotron X-ray spectro-tomography has been demonstrated as a powerful tool for probing the three-dimensional (3D) structural and chemical heterogeneity of a sample. By reconstructing a number of tomographic data sets recorded at different X-ray energy levels, the energy-dependent intensity variation in every given voxel fingerprints the corresponding local chemistry. The resolution and accuracy of this method, however, could be jeopardized by non-ideal experimental conditions, e.g. instability in the hardware system and/or in the sample itself. Herein is presented one such case, in which unanticipated sample deformation severely degrades the data quality. Here, to address this issue, an automatic 3D image registration method is implemented to evaluate and correct this effect. The method allows the redox heterogeneity in partially delithiated Li x Ta 0.3 Mn 0.4 O 2 battery cathode particles to be revealed with significantly improved fidelity.

3D image registration↗

3D Imaging with Structured Illumination for Advanced Security Applications

Three-dimensional (3D) information in a physical security system is a highly useful discriminator. The two-dimensional data from an imaging systems fails to provide target distance and three-dimensional motion vector, which can be used to reduce nuisance alarm rates and increase system effectiveness. However, 3D imaging devices designed primarily for use in physical security systems are uncommon. This report discusses an architecture favorable to physical security systems; an inexpensive snapshot 3D imaging system utilizing a simple illumination system. The method of acquiring 3D data, tests to understand illumination design, and software modifications possible to maximize information gathering capability are discussed.

42 ENGINEERING↗

Quantitative Nanoscale 3D Imaging of Intergranular Corrosion of 304 Stainless Steel Using Hard X-Ray Nanoprobe

Multi-modal imaging, which visualizes changes in the structure and chemistry of the same region of interest in materials by combining various techniques, is becoming attractive to material scientists. Here, we describe a multi-modal approach to investigate intergranular (IG) corrosion of sensitized stainless steels using synchrotron-based nanoscale X-ray imaging with sensitivity to microstructure and chemical composition. Three-dimensional tomography of 304 stainless steel samples deteriorated by IG corrosion, was carried out using X-ray fluorescence and differential phase contrast imaging. These findings were further supported with surface imaging and chemical analysis using scanning electron microscopy and energy dispersive X-ray spectroscopy. The combined quantitative structural and chemical analysis indicates that chromium segregates along grain boundaries, cracking is due to IG corrosion, and Cr-enrichment occurs on the cracked surfaces. Such quantitative 3D imaging of Cr 23 C 6 nucleation at grain boundaries and Cr enriched oxides at cracked surfaces is a powerful tool to correlate IG corrosion mechanisms at nanoscale with buried grain boundary structure and alloy composition. Such understanding of IG corrosion mechanisms is critical for both the development of predictive multiscale corrosion models, and the engineering of corrosion resistant materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-154: Establishment and Implement of 3D Image Guided Brachytherapy Planning System

Purpose: Cannot observe the dose intuitionally is a limitation of the existing 2D pre-implantation dose planning. Meanwhile, a navigation module is essential to improve the accuracy and efficiency of the implantation. Hence a 3D Image Guided Brachytherapy Planning System conducting dose planning and intra-operative navigation based on 3D multi-organs reconstruction is developed. Methods: Multi-organs including the tumor are reconstructed in one sweep of all the segmented images using the multiorgans reconstruction method. The reconstructed organs group establishs a three-dimensional visualized operative environment. The 3D dose maps of the three-dimentional conformal localized dose planning are calculated with Monte Carlo method while the corresponding isodose lines and isodose surfaces are displayed in a stereo view. The real-time intra-operative navigation is based on an electromagnetic tracking system (ETS) and the fusion between MRI and ultrasound images. Applying Least Square Method, the coordinate registration between 3D models and patient is realized by the ETS which is calibrated by a laser tracker. The system is validated by working on eight patients with prostate cancer. The navigation has passed the precision measurement in the laboratory. Results: The traditional marching cubes (MC) method reconstructs one organ at one time and assembles them together. Compared to MC, presented multi-organs reconstruction method has superiorities in reserving the integrality and connectivity of reconstructed organs. The 3D conformal localized dose planning, realizing the 'exfoliation display' of different isodose surfaces, helps make sure the dose distribution has encompassed the nidus and avoid the injury of healthy tissues. During the navigation, surgeons could observe the coordinate of instruments real-timely employing the ETS. After the calibration, accuracy error of the needle position is less than 2.5mm according to the experiments. Conclusion: The speed and quality of 3D reconstruction, the efficiency in dose planning and accuracy in navigation all can be improved simultaneously.

60 APPLIED LIFE SCIENCES↗

3D imaging of semiconductor components by discrete laminography

X-ray laminography is a powerful technique for quality control of semiconductor components. Despite the advantages of nondestructive 3D imaging over 2D techniques based on sectioning, the acquisition time is still a major obstacle for practical use of the technique. In this paper, we consider the application of Discrete Tomography to laminography data, which can potentially reduce the scanning time while still maintaining a high reconstruction quality. By incorporating prior knowledge in the reconstruction algorithm about the materials present in the scanned object, far more accurate reconstructions can be obtained from the same measured data compared to classical reconstruction methods. We present a series of simulation experiments that illustrate the potential of the approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗