Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D morphology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Protein crystal growth in microgravity

A series of protein-crystal growth experiments were performed on Space Shuttle flight STS-26 in September 1988 and STS-29 in March 1989. These proteins had been studied extensively in crystal-growth experiments on earth prior to the microgravity experiments. For those proteins which produced crystals of adequate size, 3D intensity data sets with electronic area detector systems were collected. Comparisons show that the microgravity-grown crystals of these proteins are larger, display more uniform morphologies, and yield diffraction data to significantly higher resolutions. Analyses of the 3D data sets indicate that the space-grown crystals are more highly ordered at the molecular level than their earth-grown counterparts.

Snyder, Robert↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, and spinal elongation. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, measurement tools have not been available for accurate assessments of body shape changes. This work aimed to develop a prototype 3-D body scanning system with the configuration and performance optimized for in-flight crewmember body scanning. A scan hardware system was developed using Intel RealSense commercial off-the-shelf 3D sensors. The sensor parameters were iteratively optimized and tested to obtain the performance level needed for body scanning. A scan booth structure was fabricated, with the overall size 4 x 4 x 8 feet. The specific number of sensors and mounting positions were determined by iterative simulations, which indicated that 16 cameras can capture 94% and 96% of body surface area from the 1st percentile female and 99th percentile male crew population subject. The mounted sensors were linked through a mix of USB-C and USB-3 cables and operated for data acquisition from a Linux laptop computer. A software prototype was developed using Python and Tkinter graphical user interface toolkit. A calibration procedure was also built using a panel of QR codes. A computer vision tool detected and decoded the unique ID and pattern locations of the QR codes. The calibration information determined the position and orientation of the 3D sensors with respect to each other. The scanner performance was assessed using a set of 3D printed custom manikins. The manikin size and shape were derived from the previous ISS study, which measured the crewmembers’ anthropometry changes across the different flight phases. The average anthropometric measurements at the pre-flight and flight day 15 were sampled and projected onto the 1st percentile female and 99th percentile male body shapes. Another pair of manikins were also 3D printed to simulate the neutral body posture, estimated from ISS microgravity environments. A preliminary analysis assessed the performance of the newly developed scanner against the reference scanner, which has been used at the NASA JSC for crew and test subject anthropometry. Although the new scanner data showed several artifacts and missing geometries in the occluded body areas such as armpits and crotch, overall shape matched with the reference scan. When the manikin surface coordinates were compared, a root mean square error of 1.3 cm was observed from the manikin torso segment. Linear measurements including the stature, knee height and circumference measurements at the chest and calf showed differences from the reference scan measurements, ranging between 0.3 and 0.9 cm. Overall, this work demonstrated a development framework for an in-flight scanner with design and operation optimized for crewmember body scanning. Further improvement can potentially provide previously unavailable anthropometric data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Numerical models of extragalactic radio sources

When supercomputer-implemented numerical simulations analyzing the nonlinear physics inherent in the hydrodynamic and MHD equations are applied to extragalactic radio sources, many of the complex structures observed on telescopic images are reproduced. Attention is presently given to recently obtained results from 2D and 3D numerical simulations of the formation and evolution of extended radio morphologies; these numerical models allow the exploration of such physical phenomena as the role of magnetic fields in the dynamics and emissivity of extended radio galaxies, intermittent outflow from the cores of active galaxies, fluid-jet instabilities, and the bending of collimated outflows by motion through the intergalactic medium.

Burns, Jack O.↗

Challenges in Scaling Analysis from Coupons to Elements in 3D Woven Composites for a Launch Vehicle End-Ring Structure

The limitations of structural design with 3D woven composites based on homogenized material models characterized using coupon test data, representative unit cell analysis, or a combination of the two are discussed in the context of a space launch system (SLS)-scale end ring. Selected building block test configurations at the coupon, element, and subcomponent scales are described in detail. Highly instrumented tests and X-ray computed tomography inspections are used to characterize the structural behavior and associated damage progression with increasing load. It is shown that a single homogenized material constitutive relationship, applied at coupon and element scale, is not sufficient to model the structural response observed in both tests. In fact, substantially different stress-strain laws are required to predict the response of the coupon and element scale specimens, despite similar loading conditions. A model with discrete representation of the binder tows and cohesive interfaces to model matrix cracking shows much better agreement with the test data at the two length scales. Thus, evidence is provided showing that predictive structural analysis of 3D woven composites requires discrete representation of the tows, matrix cracking morphology, and their interactions in the structural configuration. With accurate knowledge of the element scale behavior, engineering approximations readily enable analysis scale-up to the subcomponent level.

Andrew C Bergan↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Fluid Lensing and Applications to Remote Sensing of Aquatic Environments

The use of fluid lensing technology on UAVs is presented as a novel means for 3D imaging of aquatic ecosystems from above the water's surface at the centimeter scale. Preliminary results are presented from airborne fluid lensing campaigns conducted over the coral reefs of Ofu Island, American Samoa (2013) and the stromatolite reefs of Shark Bay, Western Australia (2014), covering a combined area of 15km2. These reef ecosystems were revealed with centimetre-scale 2D resolution, and an accompanying 3D bathymetry model was derived using fluid lensing, Structure from Motion and UAV position data. Data products were validated from in-situ survey methods including underwater calibration targets, depth measurements and millimetre-scale high-dynamic range gigapixel photogrammetry. Fluid lensing is an experimental technology that uses water transmitting wavelengths to passively image underwater objects at high-resolution by exploiting time-varying optical lensing events caused by surface waves. Fluid lensing data are captured from low-altitude, cost-effective electric UAVs to achieve multispectral imagery and bathymetry models at the centimetre scale over regional areas. As a passive system, fluid lensing is presently limited by signal-to-noise ratio and water column inherent optical properties to approximately 10 m depth over visible wavelengths in clear waters. The datasets derived from fluid lensing present the first centimetre-scale images of a reef acquired from above the ocean surface, without wave distortion. The 3D multispectral data distinguish coral, fish and invertebrates in American Samoa, and reveal previously undocumented, morphologically distinct, stromatolite structures in Shark Bay. These findings suggest fluid lensing and multirotor electric drones represent a promising advance in the remote sensing of aquatic environments at the centimetre scale, or 'reef scale' relevant to the conservation of reef ecosystems. Pending further development and validation of fluid lensing methods, these technologies present a solution for large-scale 3D surveys of shallow aquatic habitats with centimetre-scale spatial resolution and hourly temporal sampling.

Aquatic↗

Evaluating Retrieval Algorithm Climate Stability: Estimating 3D Optical Thickness Bias Distributions by Cloud Type

Detecting climate trends on large spatiotemporal scales requires accurate, stable measurements and stable retrieval algorithms. We strive to estimate how time-variant retrieval algorithm biases may impact trend detection. Here we focus on the 3D cloud optical thickness (τc) bias, which is among the largest in passive cloud retrieval algorithms. If this bias is time dependent, a possibility with potential decadal changes in cloud morphology, it may obscure genuine trends in τc. Although previous studies have evaluated the cloud- and sun-view geometry-dependent 3D τc bias on small spatial scales, before our current study none have evaluated the stability of this well-known bias on climate-relevant large spatiotemporal scales. These studies must estimate large scale distributions of the 3D τc bias by cloud type and estimate how cloud type amount may change between two climate states. We employ a novel approach to estimate large scale distributions of 3D τc using a proxy of the bias that quantifies the departure of clouds from satisfying the 1D radiative transfer assumption used in passive τc retrievals. This existing globally-distributed proxy is an angular consistency metric that was developed using fused Moderate-Resolution Imaging Spectroradiometer (MODIS) and Multi-angle Imaging Spectroradiometer (MISR) measurements. Calculating the 3D τc bias and the proxy, for known cloud fields enables us to establish statistical relationships between these two quantities, which can be used to calculate large-scale distributions of the 3D τc bias. This approach limits the number of 3D radiative transfer simulations required to only those needed to estimate a statistical relationship between the 3D τc bias for known cloud fields and a proxy of the bias. It is likely that future studies will be needed to evaluate retrieval algorithm bias stability for other geophysical variables as the community develops climate data records from satellite observations and their retrievals. This must be done in addition to monitoring and correcting measurement errors and uncertainties and understanding their impact on retrieved essential climate variables.

Yolanda Shea↗

Neonatal rat heart cells cultured in simulated microgravity

In vitro characteristics of cardiac cells cultured in simulated microgravity are reported. Tissue culture methods performed at unit gravity constrain cells to propagate, differentiate, and interact in a two-dimensional (2D) plane. Neonatal rat cardiac cells in 2D culture organize predominantly as bundles of cardiomyocytes with the intervening areas filled by nonmyocyte cell types. Such cardiac cell cultures respond predictably to the addition of exogenous compounds, and in many ways they represent an excellent in vitro model system. The gravity-induced 2D organization of the cells, however, does not accurately reflect the distribution of cells in the intact tissue. We have begun characterizations of a three-dimensional (3D) culturing system designed to mimic microgravity. The NASA-designed High-Aspect Ratio Vessel (HARV) bioreactors provide a low shear environment that allows cells to be cultured in static suspension. HARV-3D cultures were prepared on microcarrier beads and compared to control-2D cultures using a combination of microscopic and biochemical techniques. Both systems were uniformly inoculated and medium exchanged at standard intervals. Cells in control cultures adhered to the polystyrene surface of the tissue culture dishes and exhibited typical 2D organization. Cells cultured in HARVs adhered to microcarrier beads, the beads aggregated into defined clusters containing 8 to 15 beads per cluster, and the clusters exhibited distinct 3D layers: myocytes and fibroblasts appeared attached to the surfaces of beads and were overlaid by an outer cell type. In addition, cultures prepared in HARVs using alternative support matrices also displayed morphological formations not seen in control cultures. Generally, the cells prepared in HARV and control cultures were similar; however, the dramatic alterations in 3D organization recommend the HARV as an ideal vessel for the generation of tissuelike organization of cardiac cells in vitro.

Non-NASA Center↗

Neonatal rat heart cells cultured in simulated microgravity

In vitro characteristics of cardiac cells cultured in simulated microgravity are reported. Tissue culture methods performed at unit gravity constrain cells to propagate, differentiate, and interact in a two dimensional (2D) plane. Neonatal rat cardiac cells in 2D culture organize predominantly as bundles of cardiomyocytes with the intervening areas filled by non-myocyte cell types. Such cardiac cell cultures respond predictably to the addition of exogenous compounds, and in many ways they represent an excellent in vitro model system. The gravity-induced 2D organization of the cells, however, does not accurately reflect the distribution of cells in the intact tissue. We have begun characterizations of a three-dimensional (3D) culturing system designed to mimic microgravity. The NASA designed High-Aspect-Ratio-Vessel (HARV) bioreactors provide a low shear environment which allows cells to be cultured in static suspension. HARV-3D cultures were prepared on microcarrier beads and compared to control-2D cultures using a combination of microscopic and biochemical techniques. Both systems were uniformly inoculated and medium exchanged at standard intervals. Cells in control cultures adhered to the polystyrene surface of the tissue culture dishes and exhibited typical 2D organization. Cells in cultured in HARV's adhered to microcarrier beads, the beads aggregated into defined clusters containing 8 to 15 beads per cluster, and the clusters exhibited distinct 3D layers: myocytes and fibroblasts appeared attached to the surfaces of beads and were overlaid by an outer cell type. In addition, cultures prepared in HARV's using alternative support matrices also displayed morphological formations not seen in control cultures. Generally, the cells prepared in HARV and control cultures were similar, however, the dramatic alterations in 3D organization recommend the HARV as an ideal vessel for the generation of tissue-like organizations of cardiac cells in simulated microgravity.

Akins, Robert E.↗

In-situ Imaging of Pyrolyzing Aerospace Materials

Tracking morphological changes of materials during heating is crucial to understand its response in fire protection, biofuel production, thermal protection systems (TPS) for hypersonic flight. As materials are heated, they undergo physical and chemical changes due to water loss, stretching or shrinking, pyrolysis and chemical reactions in the ambient environment. The effects of these changes can have a profound impact on the material’s performance, indicated by changes in on the porosity and volume. While materials such as wood shrink as they pyrolyze and lose mass, others swell due to their inherent characteristics when exposed to heat [1]. This study focuses on experiments conducted at the Advanced Light Source (ALS) beamline 8.3.2, where in situ micro-computed tomography (µ-CT) is performed on materials as they are being pyrolyzed. Through in situ µ-CT, the change in total volume and porosity can be obtained in real-time, allowing for better understanding of the underlying thermophysical and chemical processes as a function of temperature. This study also focuses on the implementation of the Porous Microstructure Analysis software (PuMA) [2] to obtain thermal conductivity, permeability, and other properties of the material from the 3D tomographies. The information gained from these tomographies will supplement microscale model development of material morphological change and will aid macroscale modeling for high-temperature applications. For this study, Room Temperature Vulcanizing silicone (RTV) [3-5] is heated from room temperature to 1000°C using an infrared lamp heating system, and tomographies are continuously collected as the sample is heated. The tomographies are then segmented to obtain solid and void phases, from which estimates of pore size, porosity and total volume are extracted as a function of temperature. PuMA is deployed on the segmented tomographies to obtain thermal conductivity, permeability, and other properties as a function of temperature. Preliminary results show that RTV first intumesces (swells) as pyrolysis begins, due to build-up of pyrolysis gases in closed pores, and then shrinks significantly as more open pores are formed and the pyrolysis gases outgas. Pore network visualization of the tomographies using OpenPNM [6] showed the increase in pore connectivity with increase in temperature. Future work will focus on using PuMA to obtain macroscopic properties of RTV as a function of temperature.

Tomography↗

Optimal Estimation Inversion of Ionospheric Electron Density from GNSS-POD Limb Measurements: Part I-Algorithm and Morphology

GNSS-LEO radio links from Precise Orbital Determination (POD) and Radio Occultation (RO) antennas have been used increasingly in characterizing the global 3D distribution and variability of ionospheric electron density (N e ). In this study, we developed an optimal estimation (OE) method to retrieve N e profiles from the slant total electron content (hTEC) measurements acquired by the GNSS-POD links at negative elevation angles (ε < 0°). Although both OE and onion-peeling (OP) methods use the Abel weighting function in the N e inversion, they are significantly different in terms of performance in the lower ionosphere. The new OE results can overcome the large N e oscillations, sometimes negative values, seen in the OP retrievals in the E-region ionosphere. In the companion paper in this Special Issue, the HmF2 and NmF2 from the OE retrieval are validated against ground-based ionosondes and radar observations, showing generally good agreements in NmF2 from all sites. Nighttime hmF2 measurements tend to agree better than the daytime when the ionosonde heights tend to be slightly lower. The OE algorithm has been applied to all GNSS-POD data acquired from the COSMIC-1 (2006–2019), COSMIC-2 (2019–present), and Spire (2019–present) constellations, showing a consistent ionospheric N e morphology. The unprecedented spatiotemporal sampling of the ionosphere from these constellations now allows a detailed analysis of the frequency–wavenumber spectra for the N e variability at different heights. In the lower ionosphere (~150 km), we found significant spectral power in DE1, DW6, DW4, SW5, and SE4 wave components, in addition to well-known DW1, SW2, and DE3 waves. In the upper ionosphere (~450 km), additional wave components are still present, including DE4, DW4, DW6, SE4, and SW4. The co-existence of eastward- and westward-propagating wave4 components implies the presence of a stationary wave4 (SPW4), as suggested by other earlier studies. Further improvements to the OE method are proposed, including a tomographic inversion technique that leverages the asymmetric sampling about the tangent point associated with GNSS-LEO links.

GNSS constellation↗

Updates on the Predictive Materials Modeling Software Tools

Updates on NASA‘s efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. The PMM effort is part of the Entry Systems Modeling (ESM) project under NASA’s Game Changing Development (GCD) program. To reduce the need for extensive testing and accelerate the design cycle process, ESM is developing simulation and modeling tools that enable the characterization of the properties of thermal protection materials and their response to extremely hot plasma. The Porous Microstructure Analysis (PuMA) software has been developed to compute effective material properties and perform material response simulations on digitized microstructures of porous media. PuMA is able to import three-dimensional digital images obtained from X-ray microtomography or to generate artificial microstructures that mimic real materials. PuMA also provides a module for interactive 3D visualizations. Version 3, which was recently released as open-source, includes modules to compute simple morphological properties such as porosity, volume fractions, pore diameter, and specific surface area. Additional capabilities include the determination of effective thermal and electrical conductivity (both radiative and solid conduction - including the ability to simulate local anisotropy for the latter); effective diffusivity and tortuosity from the continuum to the rarefied regime; techniques to determine the local material orientation, as well as mechanical properties (elasticity coefficients), and permeability. Computed properties are then used to inform a macro-scale material response model, such as those implemented in the Porous material Analysis Toolbox based on OpenFOAM (PATO) software developed within ESM. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale, assuming Local Thermal Equilibrium. Recent efforts include the development of a mechanical erosion model as well as a unified model allowing an intrinsic coupling between fluid and material. Comparison to flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI] and Mars 2020 MEDLI2) is critical in order to validate these computational tools. Examples of ablative material response using the code will be presented, including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrated the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains through the use of massively parallel computations.

material modeling↗

An Optimization of Pulsed ElectroMagnetic Fields Study

To date, in our research we have focused on the use of normal human neuronal progenitor (NHNP) cells because of their importance in human nervous system regeneration, development and maintenance, but we have developed 2-D and 3-D bioreactors that can accommodate any cell line. In this Project, we will include the use of tissues important for physiological regeneration: Human osteoblasts or chondrocytes, and vascular cells. Our initial results with the NHNP cells were quite startling using extremely low-level electromagnetic fields (5 microtesla at 10Hz; 6mA). The low-amplitude, rapidly time-varying electromagnetic fields exert a very potent effect on the proliferation, morphology, and gene expression of the cells in culture, both in standard 2-dimensional culture plates as well as cells organized into 3-dimensional tissue-like assemblies (TLAs) in a 3D bioreactor. We have replicated our preliminary results many, many times, have analyzed the gene expression using gene arrays (followed by Luminex analysis for protein production), and have monitored cell proliferation, orientation, morphology, and glucose metabolism, and we are confident that we have a stable and reliable model to study the control of high-level cellular processes by application of low-amplitude, time varying electromagnetic fields (TVEMF) (1, 2). In additional studies at the University of Michigan, we have been able to generate functional in vitro engineered mammalian skeletal muscle, and have employed nerve-muscle co-culture techniques to promote axonal sprouting. We believe that nearly all tissues, in particular, neural, are susceptible to the influences of low-level TVEMF.

Goodwin, Thomas J.↗

NeMO-Net & Fluid Lensing: The Neural Multi-Modal Observation & Training Network for Global Coral Reef Assessment Using Fluid Lensing Augmentation of NASA EOS Data

We present preliminary results from NASA NeMO-Net, the first neural multi-modal observation and training network for global coral reef assessment. NeMO-Net is an open-source deep convolutional neural network (CNN) and interactive active learning training software in development which will assess the present and past dynamics of coral reef ecosystems. NeMO-Net exploits active learning and data fusion of mm-scale remotely sensed 3D images of coral reefs captured using fluid lensing with the NASA FluidCam instrument, presently the highest-resolution remote sensing benthic imaging technology capable of removing ocean wave distortion, as well as hyperspectral airborne remote sensing data from the ongoing NASA CORAL mission and lower-resolution satellite data to determine coral reef ecosystem makeup globally at unprecedented spatial and temporal scales. Aquatic ecosystems, particularly coral reefs, remain quantitatively misrepresented by low-resolution remote sensing as a result of refractive distortion from ocean waves, optical attenuation, and remoteness. Machine learning classification of coral reefs using FluidCam mm-scale 3D data show that present satellite and airborne remote sensing techniques poorly characterize coral reef percent living cover, morphology type, and species breakdown at the mm, cm, and meter scales. Indeed, current global assessments of coral reef cover and morphology classification based on km-scale satellite data alone can suffer from segmentation errors greater than 40%, capable of change detection only on yearly temporal scales and decameter spatial scales, significantly hindering our understanding of patterns and processes in marine biodiversity at a time when these ecosystems are experiencing unprecedented anthropogenic pressures, ocean acidification, and sea surface temperature rise. NeMO-Net leverages our augmented machine learning algorithm that demonstrates data fusion of regional FluidCam (mm, cm-scale) airborne remote sensing with global low-resolution (m, km-scale) airborne and spaceborne imagery to reduce classification errors up to 80% over regional scales. Such technologies can substantially enhance our ability to assess coral reef ecosystems dynamics.

satellite data↗

NASA NeMO-Net

We present preliminary results from NASA NeMO-Net, the first neural multi-modal observation and training network for global coral reef assessment. NeMO-Net is an open-source deep convolutional neural network (CNN) and interactive active learning training software in development which will assess the present and past dynamics of coral reef ecosystems. NeMO-Net exploits active learning and data fusion of mm-scale remotely sensed 3D images of coral reefs captured using fluid lensing with the NASA FluidCam instrument, presently the highest-resolution remote sensing benthic imaging technology capable of removing ocean wave distortion, as well as hyperspectral airborne remote sensing data from the ongoing NASA CORAL mission and lower-resolution satellite data to determine coral reef ecosystem makeup globally at unprecedented spatial and temporal scales. Aquatic ecosystems, particularly coral reefs, remain quantitatively misrepresented by low- resolution remote sensing as a result of refractive distortion from ocean waves, optical attenuation, and remoteness. Machine learning classification of coral reefs using FluidCam mm-scale 3D data show that present satellite and airborne remote sensing techniques poorly characterize coral reef percent living cover, morphology type, and species breakdown at the mm, cm, and meter scales. Indeed, current global assessments of coral reef cover and morphology classification based on km-scale satellite data alone can suffer from segmentation errors greater than 40%, capable of change detection only on yearly temporal scales and decameter spatial scales, significantly hindering our understanding of patterns and processes in marine biodiversity at a time when these ecosystems are experiencing unprecedented anthropogenic pressures, ocean acidification, and sea surface temperature rise. NeMO-Net leverages our augmented machine learning algorithm that demonstrates data fusion of regional FluidCam (mm, cm-scale) airborne remote sensing with global low-resolution (m, km-scale) airborne and spaceborne imagery to reduce classification errors up to 80% over regional scales. Such technologies can substantially enhance our ability to assess coral reef ecosystems dynamics.

NASA↗

Effect of Clouds on Shuttle Imaging

This report describes the results of the AMU's task for determining the effect of clouds on optical imaging of the Space Shuttle launch vehicle during its ascent phase from lift-off to Solid Rocket Booster (SRB) Separation. This effort was motivated by Recommendation R3.4-1 from the Columbia Accident Investigation Board Report. The AMU developed a 3-dimensional (3D) model to forecast the probability that at any time from lift-off to SRB separation, at least three of the ascent imaging cameras would have a view of the Shuttle unobstructed by cloud. Because current observational and modeling capabilities do not permit accurate forecasts of cloud morphology and location, the AMU simulated obscuration of the lines-of-sight (LOS) from a network of cameras to the Shuttle by idealized cloud-fields placed randomly within the 3D domain. For each random realization of numerous cloud-field scenarios the number of simultaneous views of the Shuttle was computed from the LOS data between lift-off and SRB separation. The percent of time with 3 simultaneous views was averaged from 100 random realizations of each scenario. Analyses of the percent of time viewable were made to determine its sensitivity to cloud amount, cloud base height, cloud thickness, cloud horizontal dimensions, and an upgrade of the camera network.

Short, David A.↗