Search NASA⌕ Search

SEARCH · Search NASA

Results for “66”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Half-life of {sup 66}Ga

We measured the half-life of {sup 66}Ga by observing positrons from the {beta}{sup +} branch to the ground state of {sup 66}Zn with a superconducting Wu-type beta spectrometer. Our result is t{sub 1/2}=9.304(8)hours, which is the highest-precision measurement to date and disagrees with the Nuclear Data Sheets (NDS) value by over 6{sigma}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydrotreatment of Nylon 66 and Amide Model Compounds Over Sulfided NiMo Catalysts

Molybdenum sulfide-based catalysts, such as nickel–molybdenum on alumina (NiMoS x /Al 2 O 3 ), are widely used in hydrotreating and have potential for catalyzing waste plastic conversion via hydrogenolysis, yet their performance, such as reaction kinetics and network, for amide-rich polymer feeds is poorly defined. Here we combine Nylon 66 with the amide model compound, N,N-dibutylhexanediamide (DBDAD), to quantify hydrodeoxygenation (HDO) and hydrodenitrogenation (HDN) chemistry in a stirred batch reactor (53 bar H 2 , 280–320°C). DBDAD conversion is near-linear with time, indicating strong adsorption of the substrates on the active sites. Time-resolved product identification indicates parallel C─O first-cleavagedeoxygenation (DO) and C─N first-cleavagedenitrogenation (DN) sequences proceeding through amine and diol intermediates, respectively, to C 4 ─C 6 alkanes. Increasing temperature shifts selectivity toward DN, decreasing the initial r(DO)/r(DN) from 1.38 (280°C) to 0.69 (320°C), with an apparent activation energy of 173 kJ mol −1 for DBDAD conversion. At 300°C, nylon 66 converts faster than DBDAD, producing a complex mixture of oxygen- and nitrogen-containing species and an initial rate ratio r(DO)/r(DN) of 1.6. No heteroaromatic nitrogen products are detected by the method used. These results provide reaction pathways and product signatures relevant to hydro-processing catalysts exposed to polyamide-derived streams.

Nylon 66↗

Hypofractionated Radiation Therapy (66 Gy in 22 Fractions at 3 Gy per Fraction) for Favorable-Risk Prostate Cancer: Long-term Outcomes

Purpose: To report long-term outcomes of low- and intermediate-risk prostate cancer patients treated with high-dose hypofractionated radiation therapy (HypoRT). Methods and Materials: Patients with low- and intermediate-risk prostate cancer were treated using 3-dimensional conformal radiation therapy to a dose of 66 Gy in 22 daily fractions of 3 Gy without hormonal therapy. A uniform 7-mm margin was created around the prostate for the planning target volume, and treatment was prescribed to the isocenter. Treatment was delivered using daily ultrasound image-guided radiation therapy. Common Terminology Criteria for Adverse Events, version 3.0, was used to prospectively score toxicity. Biochemical failure was defined as the nadir prostate-specific antigen level plus 2 ng/mL. Results: A total of 129 patients were treated between November 2002 and December 2005. With a median follow-up of 90 months, the 5- and 8-year actuarial biochemical control rates were 97% and 92%, respectively. The 5- and 8-year actuarial overall survival rates were 92% and 88%, respectively. Only 1 patient died from prostate cancer at 92 months after treatment, giving an 8-year actuarial cancer-specific survival of 98%. Radiation therapy was well tolerated, with 57% of patients not experiencing any acute gastrointestinal (GI) or genitourinary (GU) toxicity. For late toxicity, the worst grade ≥2 rate for GI and GU toxicity was 27% and 33%, respectively. There was no grade >3 toxicity. At last follow-up, the rate of grade ≥2 for both GI and GU toxicity was only 1.5%. Conclusions: Hypofractionation with 66 Gy in 22 fractions prescribed to the isocenter using 3-dimensional conformal radiation therapy produces excellent biochemical control rates, with moderate toxicity. However, this regimen cannot be extrapolated to the intensity modulated radiation therapy technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Networks of icosahedra in the sodium-zinc-stannides Na{sub 16}Zn{sub 13.54}Sn{sub 13.46(5)}, Na{sub 22}Zn{sub 20}Sn{sub 19(1)}, and Na{sub 34}Zn{sub 66}Sn{sub 38(1)}

The three new ternary phases Na{sub 16}Zn{sub 13.54}Sn{sub 13.46(5)} (I), Na{sub 22}Zn{sub 20}Sn{sub 19(1)} (II), and Na{sub 34}Zn{sub 66}Sn{sub 38(1)} (III) were obtained by direct fusion of the pure elements and characterized by single crystal X-ray diffraction experiments: I, Ibam, Z=8, a=27.401(1), b=16.100(1), c=18.431(1) A, R{sub 1}/wR{sub 2} (all data)=0.051/0.088; II, Pnma, Z=4, a=16.403(1), b=15.598(1), c=22.655(6) A, R{sub 1}/wR{sub 2} (all data)=0.038/0.071; III, R3-bar m, Z=3, a=16.956(1), c=36.861(1) A, R{sub 1}/wR{sub 2} (all data)=0.045/0.092. The structures consist of complex 3D cluster networks made of Zn and Sn atoms with the common motif of Kagome nets of icosahedra. Additionally to the new heteroatomic {l_brace}Zn{sub 12-x}Sn{sub x}{r_brace} icosahedra that are omnipresent, triangular units, cages, and pairs of triply fused icosahedra fill the cavities of the Kagome nets in compounds I, II, and III, respectively. Whereas I crystallizes in a new structure type, II and III have structural analogs in trielide chemistry. All three compounds closely approach the electron numbers expected for valence compounds according to the extended 8-N rule. The concept of achieving an isovalent situation to triel elements by combination of electron poorer and richer elements and the readily mixing of Zn and Sn allow the formation of icosahedral and triangular clusters without the participation of a group 13 element. - Graphical abstract: Three new compounds Na{sub 16}Zn{sub 13.54}Sn{sub 13.46(5)} (I), Na{sub 22}Zn{sub 20}Sn{sub 19(1)} (II), and Na{sub 34}Zn{sub 66}Sn{sub 38(1)} (III) were obtained from the elements and were characterized by single-crystal X-ray diffraction. Their structures have in common Kagome layers of {l_brace}Zn{sub 12-x}Sn{sub x}{r_brace} icosahedra. Additional building units, such as triangles, 15-atom spacer, and triply fused icosahedra fill the structures of I, II, and III, respectively. The structures and the electron requirements are discussed.

36 MATERIALS SCIENCE↗

Effect of thermal annealing on structure and optical band gap of Se{sub 66}Te{sub 25}In{sub 9} thin films

Thin films of a-Se{sub 66}Te{sub 25}In{sub 9} have been deposited onto a chemically cleaned glass substrate by thermal evaporation technique under vacuum. Glassy nature of the films has been ascertained by X-ray diffraction pattern. The analysis of absorption spectra, measured at normal incidence, in the spectral range 400-1100 nm has been used for the optical characterization of thin films under investigation. The effect of thermal annealing on structure and optical band gap (E{sub g}) of a-Se{sub 66}Te{sub 25}In{sub 9} have been studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Model-independent determination of the dipole response of 66 Zn using quasimonoenergetic and linearly polarized photon beams

Background: Photon strength functions are an important ingredient in calculations relevant for the nucleosynthesis of heavy elements. The relation to the photoabsorption cross section allows to experimentally constrain photon strength functions by investigating the photoresponse of atomic nuclei. Purpose: Here, we determine the photoresponse of 66 Zn in the energy region of 5.6 MeV to 9.9 MeV and analyze the contribution of the 'elastic' decay channel back to the ground state. In addition, for the elastic channel electric and magnetic dipole transitions were separated. Methods: Nuclear resonance fluorescence experiments were performed using a linearly polarized quasi-monoenergetic photon beam at the High Intensity γ-ray Source. Photon beam energies from 5.6 to 9.9 MeV with an energy spread of about 3% were selected in steps of 200–300 keV. Two high purity germanium detectors were used for the subsequent γ-ray spectroscopy. Results: Full photoabsorption cross sections are extracted from the data making use of the monoenergetic character of the photon beam. For the ground-state decay channel, the average contribution of electric and magnetic dipole strengths is disentangled. The average branching ratio back to the ground state is determined as well. Conclusions: The new results indicate lower cross sections when compared to the values extracted from a former experiment using bremsstrahlung on 66 Zn. In the latter, the average branching ratio to the ground state is estimated from statistical-model calculations in order to analyze the data. Corresponding estimates from statistical-model calculations underestimate this branching ratio compared to the values extracted from the present analysis, which would partly explain the high cross sections determined from the bremsstrahlung data.

59 ≤ A ≤ 89↗

IR Spectroscopic Study of Interatomic Interaction in [(CoFeB){sub 60}C{sub 40}/SiO{sub 2}]{sub 200} and [(CoFeB){sub 34}(SiO{sub 2}){sub 66}/C]{sub 46} Multilayer Nanostructures with Metal-Containing Composite Layers

This paper presents an IR spectroscopic study of chemical bonds between components of amorphous [(CoFeB){sub 60}C{sub 40}/SiO{sub 2}]{sub 200} and [(CoFeB){sub 34}(SiO{sub 2}){sub 66}/C]{sub 46} multilayer nanostructures (MNS’s) made up of metal-containing composite layers and different interlayers, which influence their electromagnetic properties. Our results demonstrate that, even though the MNS’s have identical elemental compositions, their IR spectra differ significantly. The reason for this is that the main contribution to the IR spectrum of the [(CoFeB){sub 60}C{sub 40}/SiO{sub 2}]{sub 200} MNS is made by its SiO{sub 2} interlayers. The formation of other bonds with oxygen and silicon is blocked by the carbon present in the (CoFeB){sub 60}C{sub 40} composite layers, as evidenced by the presence of the strongest mode in the IR spectra of this structure, which corresponds to boron carbide, BC. The considerable intensity redistribution to the low-frequency region in the IR spectrum of the [(CoFeB){sub 34}(SiO{sub 2}){sub 66}/C]{sub 46} MNS, containing carbon interlayers, is due to the incorporation of nominal SiO2 into the metal-containing composite layers and the partial redistribution of oxygen bonds from the SiO{sub 2} to the 3d transition metals, resulting in the formation of metal oxides and a silicon suboxide. The interaction of the carbon present in the interlayers between the composite layers with elements of the composite layers, in particular with boron, is considerably weaker in comparison with the other MNS, [(CoFeB){sub 60}C{sub 40}/SiO{sub 2}]{sub 200}, which has oxide interlayers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evidence for mass loss at polar latitudes in the Be stars Omega Orionis and 66 Ophiuchi

IUE observations of the pole-on Be stars Omega Ori and 66 Oph have revealed the unexpected presence of high velocity (-250 to -850 km/sec), relatively narrow (about 1 A) absorption components to the resonance lines of C IV, Si IV, and Si III. The C IV features show structure indicative of multiple shells or clouds. If Omega Ori and 66 Oph are indeed viewed pole-on, then these observations suggest that substantial matter is being ejected from the polar regions of these stars. The nature of these unusual high velocity features, which were not observed in other pole-on Be stars considered in the program, and the column densities and mass loss rates implied by them are discussed in this Letter.

Peters, G. J.↗

Wind-Tunnel Investigation of an NACA 66,2-216 Low-Drag Wing with Split Flaps of Various Sizes, Special Report

An investigation was conducted in the NACA 19-foot pressure wind tunnel of a rectangular wing having NACA 66, 2-216 low-drag airfoil sections and various sizes of simple split flaps. The purpose of the investigation was, primarily, to determine the influence of these flap installations on the aerodynamic characteristics of the wing. Complete lift, drag, and pitching-moment characteristics were determined for a range of test Reynolds numbers from about 2,600,000 to 4,600,000 for each of the installations and for the plain wing. The results of this investigation indicate that values of maximum lift coefficient similar to those of wings with conventional airfoil sections and split flaps can be expected of wings having the NACA 66,2-216 low-drag sections. The increment of maximum lift due to the split flap was found to be practically independent of the Reynolds number over the range investigated. The optimum split flap on the basis of maximum lift appears to have a chord about 20% of the wing chord and a deflection of 60 degrees. The C(sub L) max of the wing with the 0.20c partial-span flap deflected 60 degrees is 2.07 at a Reynolds number of 4,600,000 while with the full-span flap it is approximately 2.53; the increment of the maximum lift coefficient due to the flap is approximately proportional to the flap span. Although the addition of a split flap tends to hasten the stall and to cause it to occur more abruptly, little change in pattern is evidenced by observations of the behavior of wool tufts on the wing.

Muse, Thomas C.↗

Results of a 3-day Pilot Study to Validate Planetary Prebreathe Protocols Using a 56.5 kPa 34% O2, 66% N2 Saturation Cabin Atmosphere

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies was initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 3-day human-in-the-loop system checkout. METHODS: Six volunteers acclimated to the 56.6kPa/34% O2 66% N2 environment for 48hrs prior to conducting a 20-minute prebreathe and a 6-hour simulated EVA at 34kPa/85% O2 / 15% N2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs. Decompression stress was evaluated by serial doppler and echocardiographs, as well as by clinical features of DCS signs/symptoms. RESULTS AND DISCUSSION: Preliminary data analysis noted venous gas emboli (VGE) in 3 of 6 subjects, with peak Grade II VGE by Doppler and peak E-B score of 5 by cardiac ultrasonography. No volunteers were diagnosed with DCS during this initial test. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Validation of exploration prebreathe protocols has since been initiated with an 11-day saturation test using the same facility and protocol.

Alejandro Garbino↗

Evaluation of Planetary Extravehicular Activity Prebreathe Protocols using a 56.5 kPa, 34% O2, 66% N2 Saturation Cabin Atmosphere in an 11-day Hypobaric Hypoxia Study

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during Lunar extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. A cabin/vehicle “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies were initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 11-day human-in-the-loop system checkout. METHODS: Six volunteers lived in a hyboparic chamber for 11 days with an ‘exploration atmosphere’ of 56.6kPa/34% O2 66% N2. Subjects acclimated to the exploration atmosphere for 48hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15min, as well as clinical monitoring for DCS signs/symptoms. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were present in 3 of 6 subjects during EVAs, with peak Grade II VGE as evaluated by Doppler and a peak Eftedal-Brubakk score of 5 by cardiac ultrasonography. Two cases of DCS were diagnosed during the 11-day test chamber. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Two cases of DCS (8%) does not cross either accept or reject pre-test criterion, so an additional study is planned for 2023 to meet our pre-test thresholds.

Alejandro Garbino↗

Wind Tunnel Tests of Ailerons at Various Speeds I : Ailerons of 0.20 Airfoil Chord and True Contour with 0.35 Aileron-chord Extreme Blunt Nose Balance on the NACA 66,2-216 Airfoil

Hinge-moment, lift, and pressure-distribution measurements were made in the two-dimensional test section of the NACA stability tunnel on a blunt-nose balance-type aileron on an NACA 66,2-216 airfoil at speeds up to 360 miles per hour corresponding to a Mach number of 0.475. The tests were made primarily to determine the effect of speed on the action of this type of aileron. The balance-nose radii of the aileron were varied from 0 to 0.02 of the airfoil chord and the gap width was varied from 0.0005 to 0.0107 of the airfoil chord. Tests were also made with the gap sealed.

FLYING, HIGH-SPEED↗

Cross sections of projectile-like fragments in the reaction {sup 19}F+{sup 66}Zn in the beam energy range of 3-6 MeV/nucleon

Angular distributions of projectile-like fragments (PLFs) have been measured in the reaction {sup 19}F+{sup 66}Zn at E{sub lab}=61,82,92, and 109 MeV to understand their formation in the low energy domain (< or approx. 7 MeV nucleon). In this energy range, maximum angular momentum 'l{sub max}' in the reaction is lower than or close to the critical or limiting angular momentum for complete fusion 'l{sub lim}(CF).' The sum-rule model was modified to explain the cross sections of PLFs in the present study. For the first time, the modified sum-rule model, with a competition of incomplete fusion (ICF) reaction with complete fusion below l{sub lim}(CF) reasonably reproduced the cross sections of PLFs in the beam energy range of the present study. It was observed that the cross sections of lighter PLFs fall more rapidly with decreasing beam energy compared to those of heavier PLFs, suggesting a change in the reaction mechanism from heavier to lighter PLFs. Transfer probabilities for peripheral collisions were calculated within the framework of a semiclassical formalism. The parameters of the nuclear potential required for the calculation of transfer probability were obtained by fitting the elastic scattering data measured in the present work. Calculated transfer probabilities were significantly lower compared to the corresponding experimental values, suggesting a significant overlap of the projectile and the target nuclei in incomplete fusion reactions. The present analysis showed that the overlap of the projectile and the target nuclei increases with increasing mass transfer at a given beam energy and for a given PLF, overlap increases with increasing beam energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A New De Havilland Commercial Airplane : the D.H. 66 with Three Bristol "jupiter" Engines

The D.H. 66, constructed at Stag Lane Works of the De Haviland Aircraft Company built for Imperial Airways, Ltd. The fuselage has an all steel construction while the wings are made with box spars of wood and spruce ribs. It has a biplane tail and encloses the stabilizer trimming gear in a casing which serves to streamline the rear portion of the fuselage, but which is not part of the main structure. It weighs 9060 lbs. empty and 2500 lbs. after fueling with a total loaded weight of 14,700 lbs.

AIRPLANES - DES↗

Tailoring compatibilization potential of maleic anhydride–grafted polypropylene by sequential rheochemical processing of polypropylene and polyamide 66 blends

Reactive compatibilization of immiscible polymer blends using a preferred compatibilizer leaves the following question: How much loading of a compatibilizer is good enough and what maximum properties can be achieved? A good understanding of the process can help solve the reutilization of mixed waste plastics. Here, the reactive compatibilization of polypropylene-graft-maleic anhydride (PP-g-MAH) on polypropylene/polyamide 66 (PP/PA66) blends is quantitatively assessed using thermorheological, microoptical, spectroscopic, and x-ray scattering-based characterization tools. The overall compositions of all PP(60%)/PA66(30%)/PP-g-MAH(10%) blends are kept constant while systematically controlling the degree of the chemical reaction by varying the sequential addition of PP-g-MAH to the melt mixture. The first feeding of PP-g-MAH (x%, 0 ≤ x ≤ 10) is conducted at 280°C and the second feeding of (10–x)% is at 200°C. During the first step, a larger amount of chemical activity is observed up to 4%–6% addition of PP-g-MAH. Furthermore, the constant chemical composition allows a systematic comparison of the compatibilizer-dependent thermal, rheological, morphological, and mechanical properties. With an increased degree of interfacial reaction, the size of dispersed PA66 domains decreases to register improved interfacial adhesion with the PP matrix, yielding enhanced Young's modulus and absolute failure strength of the isotropic matrix.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for diphoton resonances in the 66 to 110 GeV mass range using pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search is performed for light, spin-0 bosons decaying into two photons in the 66 to 110 GeV mass range, using 140 fb −1 of proton-proton collisions at $\sqrt{s}$ = 13 TeV produced by the Large Hadron Collider and collected by the ATLAS detector. Multivariate analysis techniques are used to define event categories that improve the sensitivity to new resonances beyond the Standard Model. A model-independent search for a generic spin-0 particle and a model-dependent search for an additional low-mass Higgs boson are performed in the diphoton invariant mass spectrum. No significant excess is observed in either search. Mass-dependent upper limits at the 95% confidence level are set in the model-independent scenario on the fiducial cross-section times branching ratio into two photons in the range of 8 fb to 53 fb. Similarly, in the model-dependent scenario upper limits are set on the total cross-section times branching ratio into two photons as a function of the Higgs boson mass in the range of 19 fb to 102 fb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗