Search NASA⌕ Search

SEARCH · Search NASA

Results for “AC susceptibility measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Resonant AC power system proof-of-concept test program

Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

Wappes, Loran J.↗

Measurement of the Specific Heat Using a Gravity Cancellation Approach

The specific heat at constant volume C(sob V) of a simple fluid diverges near its liquid-vapor critical point. However, gravity-induced density stratification due to the divergence of isothermal susceptibility hinders the direct comparison of the experimental data with the predictions of renormalization group theory. In the past, a microgravity environment has been considered essential to eliminate the density stratification. We propose to perform specific heat measurements of He-3 on the ground using a method to cancel the density stratification. A He-3 fluid layer will be heated from below, using the thermal expansion of the fluid to cancel the hydrostatic compression. A 6% density stratification at a reduced temperature of 10(exp -5) can be cancelled to better than 0.1% with a steady 1.7 micro K temperature difference across a 0.05 cm thick fluid layer. A conventional AC calorimetry technique will be used to determine the heat capacity. The minimized bulk density stratification with a relaxation time 6500 sec at a reduced temperature of 10(exp -5) will stay unchanged during 1 Hz AC heating. The smear of the specific heat divergence due to the temperature difference across the cell is about 0.1% at a reduced temperature of 10(exp -6). The combination of using High Resolution Thermometry with a 0.5 n K temperature resolution in the AC technique and the cancellation of the density stratification will enable C(sub V) to be measured down to a reduced temperature of 10(exp -6) with less than a 1% systematic error.

Zhong, Fang↗

EcAMSat: Small Satellite to Examine E. coli's Response in Microgravity to the Antibiotic Gentamicin

We have successfully flown the EcAMSat (Escherichia coli Antimicrobial Satellite) free-flyer mission. This was a 6U small satellite that autonomously conducted an experiment in low Earth orbit to explore the impact of the space environment on antibiotic resistance in uropathogenic E. coli (UPEC) and the role a particular sigma factor plays in the response. After being held in stasis during transport to orbit, two strains†a wildtype UPEC and an isogenic mutant with a deleted gene that encodes a sigma factor†were grown to stationary phase in a fluidic card inside EcAMSat's payload, then incubated with three concentrations of the antibiotic gentamicin. The payload then administered alamarBlue®, a redox indicator, into all wells of the fluidic card. The cells were then incubated for 144 hours and metabolic activity was measured optically using the payloads' LED and detector system. Data were then telemetered to the ground and compared to a control experiment conducted in an identical satellite in a lab. The results of this experiment will help us better understand important therapeutic targets for treating bacterial infections on Earth and in space. Such targets are particularly relevant to deep-space and long-duration missions where crew may be more susceptible to infection and treatments for them may work differently.

antibiotic↗

Developing Glassy Magnets from Simulated Composition of Martian Soil for Exploration Applications

The long-term exploration goals of NASA include developing human habitation on Mars and conducting scientific investigations on Mars and other planetary bodies. In situ resource processing is a key objective in this area. We focus on the possibility of making magnetic glasses in situ for potential applications development. The paper will focus on ongoing work at NASA Marshall Space Flight Center on making magnetic glass from Mars soil simulants and its characterization. Analysis of the glass morphology, strength, chemistry and resulting magnetic properties will provide a fundamental understanding of the synthesized material that can be used for potential applications development. in an effort to characterize the magnetic properties of the Mars glasses, a series of tests were performed at NASA MSFC. Preliminary tests indicated that the glasses were attracted to a magnet and also had a small amount of residual magnetism. They were opaque (almost black in color). As the first step, a sample of Mars 1 glass (approx.1 mm x 1 mm x 5 mm length) was machined, weighed and its hysteresis curve was measured using a Vibration Sample Magnetometer (VSM). Next, a small furnace was designed and built and the sample was baked in a graphite (reducing agent) crucible at 800 C in an Argon atmosphere for 3 hours in the presence of a uniform, transverse (transverse to the 5mm length of the sample) magnetic field of 0.37 Tesla. The treated sample showed reddening on the outside and showed substantially increased residual magnetism. This sample was again analyzed in the VSM. The data clearly showed that some chemical change occurred during the heat treatment (color change) and that both the glasses have useful magnetic properties. Although no orientation effects of the magnetic field were considered, the data showed the following: 1. Both glass samples are primarily soft magnets and display ferromagnetic behavior (hysteresis, saturation, etc.) 2. The treated glass has improved saturation magnetism (order of magnitude increase), retentivity (factor of 6 increase) and susceptibility (order of magnitude increase) compared to the untreated glass 3. The untreated sample has higher coercivity (approx.50% that of Nickel) than the treated sample 4. Both samples have similar energy density. Results from a systematic study to quantify the effects of processing conditions such as heat treatment, atmosphere, containerless processing (by electrostatic levitation), and applications of external magnetic fields of different strengths will be discussed. Efforts on optimizing the magnetic properties of the product and the feasibility of using it for a couple of specific magnetic applications such as heat generation using an ac field and for electro forming will also be covered. The latter is an in situ manufacturing technique being studied for in-space fabrication applications at MSFC.

Ramachandran, N.↗