Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of the Third Harmonic Demagnetization Field on the ac Losses of a Granular FeSeTe Superconductor in ac Field

The first harmonics of the magnetic response, of inter- and intragranular volume fractions of a FeSe{sub 0.5}Te{sub 0.5} granular superconducting sample in an alternate magnetic field, have been numerically extracted from the measured magnetization of the whole system by using a model which considers the effects of the fundamental demagnetization fields generated by the magnetization itself. This allowed us to obtain the temperature and field behaviors of the inter- and intragranular ac losses during an ac cycle. These parameters have been found sensitive to the existence of the third harmonic components of the demagnetization field produced by the corresponding magnetization harmonics of the sample. This confirms that the effects of the magnetic response third harmonic components on the sample magnetization, through the demagnetization field, should be taken into account for a more detailed analysis of the measured ac magnetic curves.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Interfacial Resistance on AC Loss as a Function of Applied AC Field in YBCO Filamentary Conductors

To reduce ac loss in Y-Ba-Cu-O (YBCO) coated conductors while maintaining current sharing between filaments, an attempt was made to introduce an interfacial resistance between the YBCO filaments and a continuous silver cap layer. The YBCO filaments were produced via laser scribing of MOCVD YBCO films deposited on standard Ion Beam Assisted Deposition (IBAD) templates. After laser scribing, the filaments were exposed to air at room temperature to degrade the YBCO surface. A three micron thick silver cap layer was then and each sample was oxygen annealed at different temperature to produce different interface resistance at the interface between the silver and YBCO. Measurements of the ac loss was measured as a function of applied perpendicular field and frequency revealed a correlation between the reduction in coupling loss and the oxygen annealing temperature.

36 MATERIALS SCIENCE↗

Antiferromagnetic and nematic phase transitions in BaF e 2 ( A s 1 - x P x ) 2 studied by ac microcalorimetry and SQUID magnetometry

In this work, we study the antiferromagnetic (AFM) and structural phase transitions in single-crystal BaF e 2 ( A s 1 – x P x ) 2 ( x = 0 , 0.3 ) at temperatures T N and T S , respectively, by high-resolution ac microcalorimetry and SQUID magnetometry. The specific heat measurements of both as-grown and annealed BaF e 2 A s 2 display a sharp peak at the AFM-structural transitions. A kink in the entropy of annealed BaF e 2 A s 2 gives evidence for splitting of the two transitions by approximately 0.5 K. No additional features could be identified in the specific heat of both BaF e 2 A s 2 and BaF e 2 ( A s 0.7 P 0.3 ) 2 in the temperature regions around T * > T S where torque measurements had revealed the “true” nematic phase transition, even though the Ginzburg-Landau model used to fit the magnetic torque data indicates that the expected thermal anomaly should be easily observable with our experimental resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Decentralized Carrier Interleaving in Cascaded Multilevel DC-AC Converters: Preprint

Cascaded dc-ac converters with interleaved carriers are commonly used in applications where elevated voltages and low-distortion multilevel waveforms are needed. Example applications include modular multilevel converters and solid-state transformers. In such systems, carrier interleaving is generally achieved via communication among the stacked converters or a centralized controller. Due to the large number of converters in such a system, existing approaches entail significant wiring complexity and communication may limit resilience to failures. In this paper, we introduce a control strategy which achieves communication-free carrier interleaving among series-connected converters. The proposed controller is embedded within each converter control loop and only requires measurements available at each set of converter terminals. We formulate a dynamic system model and show that the system converges to the interleaved condition irrespective of the number of converters in the stack. After outlining a practical method for digital implementation, experiments are shown on a hardware-in-the-loop setup.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications - Literature Survey for Impact of Varying Refrigerant Charge on AC System Performance

The report summarizes the findings of ASHRAE Research project 1173, by Purdue University to assess the impact of varying refrigerant charge on air conditioner (AC) system performance. This project tested six residential air conditioners with varying the system charge in a wide range, using TXV or fixed-orifice as the expansion device. In summary, the systems using fixed-orifices are much more sensitive to reduction of the system charge than using TXVs. The systems using fixed-orifices had noticeable performance degradations when reducing the system charge below 90% relative to the factory charge; the systems using TXVs experienced drastic performance penalties when decreasing the system charge below 80%. In the cases, the TXVs were all fully open and couldn’t control the target superheat degree. In order to limit the system charge for lower-GWP refrigerants, without degrading the system performance much, the AC systems are recommended to use TXV and compact heat exchangers, i.e. micro-channel heat exchangers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AC to AC Solid State Transformer with Bidirectional Switches

This report details the work of the 3-year project for the AC-to-AC Solid State Transformer with Bidirectional Switches project devoted to developing and demonstrated a Type I Solid State Transformer. This report details the design, fabrication, and evaluation of both three-phase and single-phase versions of this solid state transformer operating as a single module, modules in parallel, and modules in cascade. Additionally, this report details the fabrication and evaluation of custom Silicon Carbide bidirectional switches to enable this topology with a comparison between monolithically integrated bidirectional switches as well as co-packaged back-to-back unidirectional devices. Finally, results for custom-fabricated Fe 4 N/ferrite laminated toroidal cores for high frequency transformers are present.

42 ENGINEERING↗

Development of a 10 kW High Temperature High Power Density Three-Phase AC-DC-AC SiC Converter

This paper presents the development and experimental performance of a 10 kW, all SiC, 250 C junction temperature high-power-density three-phase ac-dc-ac converter. The electromagnetic interference filter, thermal system, high temperature package, and gate drive design are discussed in detail. Finally, tests confirming the feasibility and validating the theoretical basis of the prototype converter system are described.

30 DIRECT ENERGY CONVERSION↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗