Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADCS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization and QC practice of 16-channel ADC ASIC at cryogenic temperature for Liquid Argon TPC front-end readout electronics system in DUNE experiment

ColdADC is a low-noise 16-channel analog-to-digital converter ASIC designed for cold readout electronics of Liquid Argon Time Projection Chambers (LArTPCs) in the Deep Underground Neutrino Experiment (DUNE). ColdADC was specifically designed for operation at cryogenic temperatures (77 K–89 K). Cold electronics is considered to be an enabling technology for liquid argon detectors in neutrino experiments. The main function of the chip is to digitize signals from the 16-channel charge-sensitive amplifier designed at BNL (LArASIC) and send digitized signals to the data aggregator and serializer chip (COLDATA). ColdADC operates with a resolution of 12 bits and a sampling rate of 2 MS/s per channel. A complete characterization of prototype chips was conducted at cryogenic temperature, involving power consumption, noise and linearity performance. In the first DUNE Far-Detector module, 384000 data channels will be read out, corresponding to 24000 ColdADC chips. Therefore, systematic testing of ColdADC chips at cryogenic temperature is vital for the quality and reliability of DUNE Single-Phase modules. We have developed a Quality Control (QC) test stand that includes ColdADC evaluation and characterization at cryogenic temperature. The QC procedure was applied to a first batch of 33 chips, corresponding to 528 data channels. The obtained results meet all the required DUNE specifications for ColdADC. Moreover, the testing outcome allowed us to identify possibilities of performance optimization that are currently being addressed in the design of the next version of the chip. The Quality Control procedure is proved to be successful and will be a reference design for future large-batch production testing of final ColdADC ASICs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Signal to Noise Ratios in Ion Mobility Spectrometry and Structures for Lossless Ion Manipulations (SLIM) using a High Dynamic Range Analog-to-Digital Converter

Signal digitization is a commonly overlooked part of ion mobility-mass spectrometry (IMS-MS) workflows, yet it is a significant contributor for determining signal-to-noise ratios and MS resolution. Here we report on the integration of a 2 GS/s, 14-bit ADC with a structures for lossless ion manipulations (SLIM)-IMS-MS and compare the performance to a commonly used 8-bit ADC. The 14-bit ADC provided an effective reduction in digitized noise by factor of ~6, owing largely to the use of smaller bit sizes. The low baseline allowed the threshold voltage levels to be set very close to the MCP baseline voltage, allowing for as much signal to be acquired as possible without causing overloading or excessive digitization of MCP baseline noise. Analyses of Agilent tuning mixture ions and a complex mixture of heavy labeled phosphopeptides showed that the 14-bit ADC (compared to the 8-bit ADC) provided a modest signal-to-noise increase (~1.5 to 2-fold) for high intensity ions, such as the Agilent tuning mixture ions and the 2+ and 3+ charge states of many phosphopeptide constituents. However, signal enhancements were as much as 10-fold for low intensity ions, and the 14-bit ADC enabled discernable signal intensities otherwise lost using an 8-bit digitizer. Additionally, the 14-bit ADC required ~14-fold fewer mass spectra to be averaged to produce a mass spectrum with similar S/N as the 8-bit ADC under identical conditions, potentially providing an order of magnitude higher measurement throughput. The high resolution, low baseline, and fast speed of the new 14-bit ADC enables high performance digitization of MS, IMS-MS, and SLIM-IMS-MS spectra, and allows a much fuller picture of analyte profiles in complex mixtures to be acquired.

data acquisition, digitization, ion mobility spect↗

Synthesis of site-specific antibody-drug conjugates by ADP-ribosyl cyclases

Most of the current antibody-drug conjugates (ADCs) in clinic are heterogeneous mixtures. To produce homogeneous ADCs, established procedures often require multiple steps or long reaction times. The introduced mutations or foreign sequences may cause high immunogenicity. Here, we explore a new concept of transforming CD38 enzymatic activity into a facile approach for generating site-specific ADCs. This was achieved through coupling bifunctional antibody-CD38 fusion proteins with designer dinucleotide-based covalent inhibitors with stably attached payloads. The resulting adenosine diphosphate–ribosyl cyclase–enabled ADC (ARC-ADC) with a drug-to-antibody ratio of 2 could be rapidly generated through single-step conjugation. The generated ARC-ADC targeting human epidermal growth factor receptor 2 (HER2) displays excellent stability and potency against HER2-positive breast cancer both in vitro and in vivo. This proof-of-concept study demonstrates a new strategy for production of site-specific ADCs. It may provide a general approach for the development of a novel class of ADCs with potentially enhanced properties.

59 BASIC BIOLOGICAL SCIENCES↗