Search NASA⌕ Search

SEARCH · Search NASA

Results for “AFOSR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

23 records · Page 2

Separation and Transition on the ROTEX-T Cone-Flare

As part of NATO STO AVT-346 “Predicting Hypersonic Boundary-Layer Transition on Complex Geometries,” coordinated experimental and computational studies were conducted on the ROTEX-T, a cone-flare geometry used in a successful flight-test experiment. At the as-flown conditions, a separation bubble existed at the compression corner. Separation, reattachment, and the multifaceted linear instability paths leading this bubble to transition to turbulence are challenging to predict, but have significant impact on surface pressure and heat flux. High-resolution background-oriented schlieren and infrared thermography measurements were made in the AFOSR–Notre Dame Large Mach-6 Quiet Tunnel at freestream unit Reynolds numbers from 5.8×10(exp 6) to 12.2×10(exp 6) m-1and nominally zero angle of attack. High-speed self-aligned focusing schlieren, infrared thermography, and focused laser differential interferometry measurements were made in the AFRL Mach-6 Ludwieg Tube from 2.2×10(exp 6) to 24.7×10(exp 6) m-1and nominally zero degrees angle of attack. The surface heat-flux and Stanton number distributions were computed. Separation and reattachment locations, as well as the flow state at each, were determined from the combination of surface and off-wall measurements. The convective and global boundary-layer instabilities of the axisymmetric laminar flow at the experimental conditions were investigated computationally. Amplification of Mack’s first and second modes were observed to have logarithmic amplification factors between 5 to 7.5 at the separation location, depending on conditions. The flow was found to be globally unstable to stationary three-dimensional disturbances concentrated in the reattachment region. Previous analysis of the ROTEX-T flight data had not assessed reattachment location or the flow state upon reattachment. Thanks to the insights gained from the coordinated, on- and off-wall ground-test measurements, these evaluations have now been made. The separation location indicated by laminar simulations is consistently numerically predicted to be upstream of the experimentally observed location for a transitional separation bubble. The cause of this difference is understood to lie in the steady-state and axisymmetric assumptions made by both solvers employed to compute the basic states analyzed, as flow topology considerations assert that unsteady two-dimensional or axisymmetric separation bubbles are structurally unstable and will become three-dimensional. Computed laminar heating rates prior to separation agreed well with experiment; transitional heating rates after reattachment were between laminar and turbulent computations.

CFD Validation↗

Separation and Transition on the ROTEX-T Cone-Flare

As part of NATO STO AVT-346 “Predicting Hypersonic Boundary-Layer Transition on Complex Geometries,” coordinated experimental and computational studies were conducted on the ROTEX-T, a cone-flare geometry used in a successful flight-test experiment. At the as-flown conditions, a separation bubble existed at the compression corner. Separation, reattachment, and the multifaceted linear instability paths leading this bubble to transition to turbulence are challenging to predict, but have significant impact on surface pressure and heat flux. High-resolution background-oriented schlieren and infrared thermography measurements were made in the AFOSR–Notre Dame Large Mach-6 Quiet Tunnel at freestream unit Reynolds numbers from 5.8×10(exp 6) to 12.2×10(exp 6) m-1and nominally zero angle of attack. High-speed self-aligned focusing schlieren, infrared thermography, and focused laser differential interferometry measurements were made in the AFRL Mach-6 Ludwieg Tube from 2.2×10(exp 6) to 24.7×10(exp 6) m-1and nominally zero degrees angle of attack. The surface heat-flux and Stanton number distributions were computed. Separation and reattachment locations, as well as the flow state at each, were determined from the combination of surface and off-wall measurements. The convective and global boundary-layer instabilities of the axisymmetric laminar flow at the experimental conditions were investigated computationally. Amplification of Mack’s first and second modes were observed to have logarithmic amplification factors between 5 to 7.5 at the separation location, depending on conditions. The flow was found to be globally unstable to stationary three-dimensional disturbances concentrated in the reattachment region. Previous analysis of the ROTEX-T flight data had not assessed reattachment location or the flow state upon reattachment. Thanks to the insights gained from the coordinated, on- and off-wall ground-test measurements, these evaluations have now been made. The separation location indicated by laminar simulations is consistently numerically predicted to be upstream of the experimentally observed location for a transitional separation bubble. The cause of this difference is understood to lie in the steady-state and axisymmetric assumptions made by both solvers employed to compute the basic states analyzed, as flow topology considerations assert that unsteady two-dimensional or axisymmetric separation bubbles are structurally unstable and will become three-dimensional. Computed laminar heating rates prior to separation agreed well with experiment; transitional heating rates after reattachment were between laminar and turbulent computations.

CFD Validation↗

Opportunities in Intense Ultrafast Lasers: Reaching for the Brightest Light

The laser has revolutionized many areas of science and society, providing bright and versatile light sources that transform the ways we investigate science and enable trillions of dollars of commerce. Now a second laser revolution is under way with pulsed petawatt-class lasers (1 petawatt: 1 million billion watts) that deliver nearly 100 times the total world’s power concentrated into a pulse that lasts less than one-trillionth of a second. Such light sources create unique, extreme laboratory conditions that can accelerate and collide intense beams of elementary particles, drive nuclear reactions, heat matter to conditions found in stars, or even create matter out of the empty vacuum. These powerful lasers came largely from U.S. engineering, and the science and technology opportunities they enable were discussed in several previous National Academies’ reports. Based on these advances, the principal research funding agencies in Europe and Asia began in the last decade to invest heavily in new facilities that will employ these high-intensity lasers for fundamental and applied science. No similar programs exist in the United States. This report was commissioned by four U.S. agencies—the Office of Naval Research (ONR), the Air Force Office of Scientific Research (AFOSR), the Department of Energy’s Office of Science (DOE-SC), and the National Nuclear Security Administration (NNSA)—to assess the opportunities and to recommend a path forward for possible U.S. investments in this area of science.

47 OTHER INSTRUMENTATION↗

Characterization of thermally heat-treated polyacrylonitrile carbon fibers

This study investigates the graphitization process of polyacrylonitrile (PAN) carbon fibers by subjecting commercial fibers to thermal heat treatment at temperatures ranging from 1400 to 2100 °C in 100 °C increments, using either argon or nitrogen gas atmospheres. Changes in crystallinity, surface morphology, and lattice parameters were analyzed for two commercial carbon fibers using X-ray diffraction, scanning electron microscopy, and Raman spectroscopy. Results indicated minimal changes in surface morphology with increasing heat-treatment temperature; however, crystallinity significantly increased. Crystallinity changes were more strongly dependent on temperature rather than gas atmosphere or fiber type. At intermediate heat-treatment temperatures (1600–1800 °C), fibers treated in argon showed a slight preference for graphitization. The highest level of graphitization was measured at 2100 °C. Crystallite size increased as the intensity ratio of the D1 to G Raman peaks increased, reaching a peak around ~1800 °C, after which the ratio started to decrease. This behavior aligns with Ferrari's three-stage model of carbon crystallization and is consistent with both the Marie-Mering degree of graphitization and Brubaker's Integrated Absolute Differential models, all of which describe the transformation from an amorphous to a more graphitic structure. At the higher heat-treatment temperatures, the changes between atmospheres and fiber types were measured to converge to similar levels of graphitization. In conclusion, this study evaluates the progressive change in commercial grade carbon fibers when heat-treated.

Characterization↗