Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR PURIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The His-tag as a decoy modulating preferred orientation in cryoEM

The His-tag is a widely used affinity tag that facilitates purification by means of affinity chromatography of recombinant proteins for functional and structural studies. We show here that His-tag presence affects how coproheme decarboxylase interacts with the air-water interface during grid preparation for cryoEM. Depending on His-tag presence or absence, we observe significant changes in patterns of preferred orientation. Our analysis of particle orientations suggests that His-tag presence can mask the hydrophobic and hydrophilic patches on a protein’s surface that mediate the interactions with the air-water interface, while the hydrophobic linker between a His-tag and the coding sequence of the protein may enhance other interactions with the air-water interface. Our observations suggest that tagging, including rational design of the linkers between an affinity tag and a protein of interest, offer a promising approach to modulating interactions with the air-water interface.

59 BASIC BIOLOGICAL SCIENCES↗

Electrification and decarbonization of spent Li-ion batteries purification by using an electrochemical membrane reactor

The expanding electric vehicle market brings with it exponential growth in the use of lithium (Li)-ion batteries (LIB) for which a wave of spent LIB is expected to come within the next 5 to 10 years. Due to the economic and strategic value imbedded within the metals contained in LIB, different recycling technologies, including hydrometallurgy, pyrometallurgy and direct recycling, are under development. Being different from previous hydrometallurgical methods, which may have high chemical consumption and negative environmental impact, an electrochemical membrane reactor is designed and validated for the first time, to electrify and decarbonize the impurity removal process. This reactor electroplates copper (Cu) and electrochemically precipitates aluminum (Al) and iron (Fe) from simulated spent LIB leachates, by consuming only air, water, and electricity, and the impurities are reduced to <1 ppm. The purified leachate maintains 99.5 % of the nickel (Ni), 95.4 % of the cobalt (Co) and 99.14 % of manganese (Mn) from the original leachate solution, and then can be directly applied for cathode precursor synthesis. Additionally, the purification process doesn’t introduce extra impurity, and the reactor restoration process generates valuable by-product hydro sulfate (H2SO4). This electrochemical process can reduce the cost, because of the much less chemical consumption and the valuable by-product generation, and mitigates the waste emissions, because of no extra impurity introduced and no greenhouse gas (GHG) produced. In conclusion, the chemical precipitation method uses significant amount of NaOH, which induced GHG emission during the manufacturing process.

25 ENERGY STORAGE↗

Electrochemical Mitigation of Corrosion in Molten Chloride Salts During CSP Plant Operation

We are designing an electrochemical flow-cell for removal of corrosive impurities from molten chloride salt Gen3 Concentrating Solar Power (CSP) plants during plant operation. Corrosive impurities will inevitably form in molten chloride salts upon exposure to air and moisture. We previously showed that even small amounts of these impurities, especially MgOHCl, will be detrimental in Gen3 CSP plants, necessitating prohibitively expensive containment alloys and frequent replacement of corroded components. Pre-purification of salt with Mg metal at temperatures above 650 degrees C is the current method for removing corrosive impurities from chloride salts before they are introduced to CSP systems. However, this is not a suitable method for impurity removal during plant operation. First, this method will produce MgO particulates which will damage plant components. Second, Mg metal is solid at the low temperature point (500 degrees C), so the purification will not proceed at a fast rate. At the high temperature point, Mg is soluble. In this case, fast purification may proceed, but dissolved metal is likely to precipitate out in cold-temperature point components, causing damage. In contrast, our electrochemically driven method allows fast Mg-based purification to proceed at the low temperature point, without formation of harmful particulates and without the risk of Mg metal precipitation. This novel approach is inspired by electrorefining techniques that are widely employed in industrial metallurgy for removal of impurities from metals. Impurities in the incoming molten salt will be reduced to inert MgO at the cathode, which can be removed by periodically washing the cell with acid. Simultaneously, Mg dissolution at the anode will ensure salt composition is maintained, with no net removal of Mg2+. We have validated this electrochemical approach at lab scale under static conditions with batch rectors. Furthermore, we have performed analytical modeling and technoeconomic analysis to produce a preliminary engineering design for the purification flow cell.

CSP↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

Electrochemical Control for Corrosion in Molten Chlorides During CSP Plant Operation

The Liquid Pathway of the Concentrating Solar Power Generation 3 (CSP Gen3) program proposed low-cost molten chloride salt for energy storage. However, online corrosion control was identified as a remining major risk of the Liquid Pathway approach. This project addressed that risk. Electrochemical solutions for corrosion mitigation during CSP plant operation were investigated and their feasibility and scalability were evaluated. The leading cause of corrosion in molten chloride salt systems was identified as corrosive impurities that form within the salt upon exposure to trace amounts of air and moisture. Leveraging electrochemistry, reduction/oxidation reactions can be employed to remove these corrosive impurities. In Phase 1 of this project, a bench-scale batch electrochemical reactor was designed, fabricated, and used to assess the kinetics and thermodynamics of electrochemical salt purification. In Phase 2, a laboratory-scale flow reactor was designed, fabricated, and used to assess the efficacy of the electrochemical method under flowing conditions. Results show that under proposed operating conditions for the Liquid Pathway Gen3 Pilot Plant, the electrochemical method is significantly more effective at removing impurities than alternative chemical and thermal methods, and that the electrochemical method produces less harmful byproducts. A key advance made in the course of this project was the development of a 2-electrode method for electrochemical purification that is more scalable than previously developed 3 electrode methods. This novel method is based on Magnesium (Mg) electrowinning. A provisional patent based on this invention has been submitted (USPTO Application No. 63/480,355). Additional key advances made during this project include assessment of the effect of dissimilar alloys on corrosion, kinetic and thermodynamic evaluation of thermolysis reactions of impurities within the molten salt, characterization of byproducts of purification reactions, and generation of IP focused on isolating value-added products using molten salt-based electrochemistry that could be deployed to valorize the process (USPTO Application No. 63/478,806). Ultimately, this project represented a step toward feasibility of Liquid Pathway Gen3 CSP. The method developed under this project could significantly reduce capital expenses and operating costs and increase plant profitability by enabling use of less expensive alloys, decreasing maintenance, and increasing plant longevity. Key focus areas for follow-on work have been identified as 1) evaluation of the efficacy of the electrochemical method under turbulent conditions in a larger flow system, such as the FASTR loop, 2) development of methods for removal of purification byproducts, 3) modeling pilot and industrial scale performance of electrochemical salt purification during plant operation and 4) further assessment of the effect of impurities on salt vapor phase.

14 SOLAR ENERGY↗

Spatiotemporal Adaptive Passive Direct Air Capture

Carbon Collect Inc., along with Arizona State University, the Electric Power Research Institute (EPRI), PM Group, and Trimeric Corporation, completed an initial design of a commercial-scale, passive direct air capture (DAC) system termed “carbon trees” that will capture, separate, and store at least 100,000 tonnes/year of carbon dioxide (CO2) from air (net basis). Passive DAC is unique among DAC technologies in that passive air delivery by wind avoids the energy penalty of forced convection. Carbon Collect Inc.’s sorbent-agnostic approach offers the flexibility to choose sorbents for a wide range of climates. A combination of steam, low-grade heat, and vacuum releases the CO2 from the sorbent, which is extracted from the chamber and purified and compressed for geological storage. A commercial carbon tree forest combines the output of several thousand trees for compression and purification with high heat and energy integration. The project team prepared an initial engineering design package for each of three geographically diverse host sites throughout the United States to better understand the effect of local/regional ambient conditions on DAC system performance and project costs. A techno-economic analysis, life cycle analysis, business case analysis, and an environmental, health, and safety risks assessment were also completed for each of the three geographically diverse host sites.

14 SOLAR ENERGY↗

Oxy-Combustion System Process Optimization

The overall objective of this work is to develop a new chemical absorbent-based, high pressure, CO 2 purification system to remove the residual oxygen that currently contaminates the recovered CO 2 , and to optimize the Pressurized Oxy-Combustion (POxC) process to minimize the Cost of Electricity (COE) generated in this advanced combustion process. TDA developed and validated the performance of the oxygen removal system for CO 2 purification. In collaboration with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI), we optimized the POxC process, including thermal management, heat integration, and power cycle optimization using process design and modeling supported with Aspen Plus® process simulations. The techno-economic analysis results indicate that the pressurized oxycombustion coal power plant with Ion-transport membrane (ITM) air separation unit (ASU) (Case 2 – 30.55%) does not show an advantage over a cryogenic ASU (Case 1 – 31.24%) while TDA’s sorption-based ASU (Case 4 - 32.61%) shows a significant advantage over the cryogenic ASU (Case 1 – 331.24%). The specific plant costs show a wide range with a low of $2544/kW for Case 11C (TDA ASU, co-sequestering the SO x , and ultra-supercritical steam cycle) to a high of $2975/kW for Case 12A (cryogenic ASU and sCO 2 cycle). In general, the ITM ASU based cases have lower specific plant costs than the corresponding cryogenic ASU based cases while the TDA ASU based cases show the lowest specific plant costs. The main reason for lowering these costs is the higher overall plant thermal efficiency which decreases the plant cost on a $ per kW basis. Next comparing the cases with different power cycle working fluid conditions in terms of temperature and pressure while all utilizing steam, similar trends as the plant costs may be observed. However, with the supercritical CO 2 (sCO 2 ) cycle, the increase in thermal efficiency of the sCO 2 cycle was not able to offset its increase in plant cost making the plant costs higher than those of the corresponding steam cycle cases. The Cost of Electricity (COE) again shows similar trends as the specific plant costs. The COE for Case 11C at $110.1/MWh is also the lowest, but among all cases that do not co-sequester the SO x , Case 12C (TDA ASU and sCO 2 cycle) has the lowest COE at $\$$117.5/MWh while the highest is for Case 8A (cryogenic ASU and supercritical steam cycle) at $130.4/MWh.

20 FOSSIL-FUELED POWER PLANTS↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparing energy and water use of aqueous and gas-based metalworking fluids

Gas-based metalworking fluids (MWFs) have been proposed as alternative coolants and lubricants in machining operations to mitigate concerns surrounding water use and pollution, industrial hygiene, occupational health, and performance limitations associated with water-based (aqueous) MWFs that are ubiquitously used in the metals manufacturing industry. This study compares the primary energy and water use associated with the consumptive use, delivery, and disposal of aqueous MWFs with three gas-based MWFs in the literature-minimum quantity lubricant-in-compressed air (MQL), liquid/gaseous N-2, and liquid/supercritical CO2. The comparison accounts for reported differences in machining performance in peer-reviewed experimental studies across several machining processes and materials. The analysis shows that despite the reported improvement in tool life with N-2 and CO2-based MWFs, the electricity- and water-intensive separation and purification processes for N-2 and CO2 lead to their higher primary energy and water use per volume of material machined relative to water-based MWFs. Although MQL is found to have lower primary energy use, significant consumptive water use associated with the vegetable oil commonly used with this MWF leads to higher overall water use than aqueous MWF, which is operated in a recirculative system. Gas-based MWFs thus shift the water use upstream of the manufacturing plant. Primary energy and water use of gas-based MWFs could be reduced by focusing on achieving higher material removal rates and throughput compared to aqueous MWF instead of solely targeting improvements in tool life. Additionally, the consumptive use of CO2 and N-2 MWFs could be minimized by optimizing their flow rates and delivery to precisely meet the cooling and lubrication needs of specific machining processes instead of flooding the tool and workpiece with these gases. This article met the requirements for a gold-gold JIE data openness badge described at http://jie.click/badges.

cutting fluids↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Photoautotrophic organic acid production: Glycolic acid production by microalgal cultivation

Although microalgae produce value-added products, such as lipids, pigments, and polysaccharides using light and carbon dioxide, these intracellular products require costly downstream processes such as extraction and purification. Thus, extracellular products are desirable for economic production. While reported before, the secretion of glycolic acid by microalgal photorespiration has not received attention for industrial applications. Here we developed a two-stage continuous cultivation system to increase glycolic acid production using a glycolate dehydrogenase (GYD1) deficient mutant of Chlamydomonas reinhardtii which produces high concentrations of glycolic acid. Specifically, 3% CO 2 was supplied in the first-stage culture for the production of biomass and ambient air (0.03% CO 2 ) was supplied to the second stage for the production of glycolic acid. As a result, overall glycolic acid productivity reached 82.0 mg L -1 d -1 at a dilution rate of 0.34 d -1 . However, as the pH of the second stage decreased to 4.7 due to the increased glycolic acid production, we controlled the pH of the second stage at pH 6.0, resulting in 122.6 mg L -1 d -1 of glycolic acid productivity. Flux balance analysis revealed that the experimental glycolic acid production rate was 69% of the theoretical glycolic acid production rate. The deviation might be due to the toxicity of glycolic acid. When a techno-economic analysis was conducted based on the experimental results, the minimum glycolic acid production cost was estimated to be $31 kg -1 , indicating a potential for industrial production. Our findings suggest that microalgae can be utilized for the cost-effective industrial production of glycolic acid.

42 ENGINEERING↗

Heterogenous catalysis for oxygen tolerant photoredox atom transfer radical polymerization and small-molecule dehalogenation

Heterogeneous photocatalysts (PCs) have garnered attention for their sustainability and cost-effectiveness. Despite the existence of various types of these PCs, their synthesis often involves complex, multi-step procedures and laborious purification. Herein, we propose a simple method for attaching small-molecule photocatalytic species onto crosslinked 3-D polymer networks as insoluble scaffolds to create robust heterogeneous PCs. The highly swellable poly(ethylene glycol)-based ChemMatrix (CM) resin, known for its amphiphilic properties and high functional group loading, facilitated the covalent immobilization of the photoredox dye Eosin Y (EY), but also streamlined functionalization with Ir( III ) complexes. The resulting heterogeneous CM-EY demonstrated efficient photocatalytic performance in open-to-air dual photoredox catalysis of atom transfer radical polymerization (photo-ATRP) under green light. This was confirmed by the well-controlled synthesis of polymers with molecular masses ranging from 20 kDa to 300 kDa and low dispersities. Furthermore, CM-EY exhibited excellent photostability and recyclability over multiple cycles of ATRP. The heterogeneous catalysis of photo-ATRP provided high temporal control and enabled benign conditions for synthesizing protein-polymer hybrids (PPH). When combined with the initiator-modified CM (CM-BIB), CM-EY facilitated the solid-phase synthesis of homopolymers and block copolymers with recyclable performance. However, the coordinatively bound Ir@CM showed decreased catalytic activity and efficiency toward photoredox dehalogenation due to the leaching of active species during recycling. This study highlights the advantages of the covalent linking of catalysts to solid supports over non-covalent interactions, underscoring the potential of functionalized polymer resin as a promising scaffold. Such an approach offers customization and tunability, presenting opportunities for innovation in green chemistry.

Kapil, Kriti↗

Molten Salt Loop Testing of Sensors and Off-Gas Components: FY23 progress

The Liquid Salt Test Loop (LSTL) at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature fluoride salt systems (Figure 1). The LSTL is primarily constructed using Inconel 600 alloy and operates at temperatures of up to 700°C. The facility is loaded with 165 kg of LiF-NaF-KF salt (FLiNaK). This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. FLiNaK is also an advantageous salt for the secondary side of molten salt reactors. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. Additional heating is available through an induction heater rated at 200 kW. The relatively large heating and cooling capability enables the formation of a temperature gradient across the loop (i.e., a hot and a cold side), which is important for chemistry and corrosion studies. The LSTL is a unique US capability for high-temperature molten halide salt testing. Although some efforts are underway at universities, the LSTL’s scale, co-located purification system, and relatively large power differentiates it from other testing systems. Furthermore, unlike efforts within industry, access to the DOE-supported facility and communication of results, which are generally disseminated publicly, result in a broad significance in the molten salt reactor community.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Hybrid biophysical systems for atmospheric CO 2 capture

Negative emissions technologies will be essential for limiting anthropogenic global temperature increases to 2 °C in the later years of the 21st century. Carbonic anhydrase (CA) metalloenzymes catalyze the otherwise slow conversion of CO 2 into carbonic acid (H 2 CO 3 ), suggesting their utility in the rapid hydration and downstream capture of dissolved CO 2 in aqueous media for a variety of CO 2 capture methods, such as thermal and pH swings and mineralization. The possibility of driving the rapid capture of CO 2 by catalyzing the CO 2 hydration bottleneck carries real potential for realizing efficient direct air capture (DAC) and direct ocean capture (DOC) systems. However, scaled application of CAs will be dependent on some way of economically sourcing the enzymes at volumes relevant to scaled DAC/DOC operations. In this perspective, we consider the prospect of catalyzing CO 2 hydration using a CA that is bound to the outer membrane of a cyanobacterial host, engineered constructs we call CyCAMs. Coupling extracellular CA expression to a marine, photosynthetic cyanobacterial host results in a CO 2 hydration catalyst that is continuously refreshed during the bacterial growth cycle, without the need for enzyme purification or harvesting steps. In the case of marine cyanobacteria, sunlight and the solutes native to seawater provide the respective energy, nutrients and sources of inorganic carbon essential to maintaining the bacterial population. We consider the potential impact of CA-mediated CO 2 hydration on a variety of DAC processes, with CO 2 mineralization explored as a primary use case.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Investigation of Moisture Byproducts in Molten Calcium Chloride

Residual water in molten CaCl 2 reacts to form different byproducts, such as HCl, which can impact the corrosivity of the salt and efficiency of electrochemical operations, such as electrolytic oxide reduction and electrorefining. The ability to detect and quantify these byproducts electrochemically can provide feedback on the efficacy of vacuum drying and other purification methods, as well as the impact of these byproducts on process operations. An electrochemical signal’s association with the production of H 2 is verified and characterized using cyclic voltammetry (CV) and residual gas analysis. CV estimated a 2-electron exchange process associated with H 2 production. CV detected trace quantities of an oxidized species containing hydrogen in the salt on the order of 10 ppm. Different salt handling methods were compared for their impact on the hydrogen electrochemical signal. It was found that 30 min of exposure of CaCl 2 in a beaker to low-humidity air (<20%) had minimal impact on the H 2 production signal.

Electrochemistry↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗