Search NASA⌕ Search

SEARCH · Search NASA

Results for “ALTERNATING CURRENT GENERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental demonstration of transient CHI start-up using a floating biased electrode configuration

Transient coaxial helicity injection (CHI) current start-up in a spherical tokamak (ST) has been demonstrated for the first time using a reactor-relevant floating single biased (FSB) electrode configuration on QUEST. Unlike previous applications of CHI on HIT-II and on NSTX in which the entire ST vessel was split in two using two toroidal ceramic rings as vacuum breaks, in the FSB electrode configuration on QUEST, only the lower outer divertor plate is electrically insulated from the rest of the vessel. This is the CHI injector region. A CHI discharge is generated by driving current, using an external power supply, along magnetic field lines that connect the inner and outer divertor plates in the CHI injector region. The CHI plasma evolution and closed flux formation on QUEST are very similar to those on NSTX and have generated toroidal currents of 150 kA with 100 kA of current flowing on closed flux surfaces. An alternate, force-free model approach has been used to derive the CHI scaling relations. The resulting CHI scaling relations from the model are consistent with the conventional CHI scaling relations, which state that the CHI generated toroidal current is proportional to the CHI injector flux and the CHI injector current is inversely proportional to the toroidal field. These results from QUEST bode well for the application of CHI in a new generation of compact high field STs and low aspect ratio tokamaks in which the space for the central solenoid is very restricted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating Neutrino Event Generation in MARLEY Using CUDA-Based RNG and GPU Parallelization

MARLEY is a simulation tool that helps scientists study how low-energy neutrinos interact with matter. To work properly, MARLEY uses random numbers thousands of times in each simulation. These random numbers are important for modeling things like how neutrinos collide with atoms and what particles they produce. Right now, MARLEY runs on a regular computer processor (CPU) and uses a built-in random number generator called the Mersenne Twister. This setup works, but it can be slow, especially when trying to simulate many events. This research focuses on making MARLEY run faster by moving the random number generation and some of the repetitive calculations from the CPU to a graphics processing unit (GPU), which can handle many tasks at the same time. We use CUDA (a tool for programming NVIDIA GPUs) and cuRAND (a GPU-based random number library) to test faster alternatives to the current random number system. We compare different GPU-based generators, like curand_mtgp32, xorwow, and philox, to see which ones are the quickest and still give reliable results. Early tests show that using the GPU can make MARLEY simulations much faster. This project not only helps improve current simulation performance but also moves closer to a full simulation chain where all stages can run on modern GPU hardware.

Dunkley, Kimieka [Florida A-M]↗

Eddy Current Lift-Off Sensor Model

Eddy current sensors measure the lift-off or distance between the sensor head and a conducting surface. The sensor consists of a conducting coil carrying an alternating electrical current. By Faraday’s Law, a magnetic field is generated within the coil. This field induces electrical current loops within the conducting surface which in turn generate a magnetic field. This induced magnetic field opposes the coil magnetic field and thus, the current in the coil. This reduces the inductance of the coil while increasing its resistance. The strength of the induced magnetic field and consequently the coil inductance are proportional to the lift-off of the coil from the surface. Thus, a measurement of the coil inductance may yield a measure of the lift-off.

42 ENGINEERING↗

Coherent spin wave excitation with radio-frequency spin–orbit torque

Spin waves, collective perturbations of magnetic moments, are both fundamental probes for magnetic physics and promising candidates for energy-efficient signal processing and computation. Traditionally, coherent propagating spin waves have been generated by radio frequency (RF) inductive Oersted fields from current-carrying electrodes. An alternative mechanism, spin–orbit torque (SOT), offers more localized excitation through interfacial spin accumulation but has been mostly limited to DC to kHz frequencies. SOT driven by RF currents, with potentially enhanced pumping efficiency and unique spin dynamics, remains largely unexplored, especially in magnetic insulators. Here, we conduct a comprehensive theoretical and computational investigation into the generation of coherent spin waves via RF-SOT in the prototypical yttrium iron garnet. We characterize the excitation of forward volume, backward volume, and surface modes in both linear and nonlinear regimes, employing single and interdigitated electrode configurations. We reveal and explain several unique and surprising features of RF-SOT compared to inductive excitation, including higher efficiency, distinct mode selectivity, and directional symmetry, a ~ $3π/4$ phase offset, reduced anharmonic distortion in the nonlinear regime, and the absence of second harmonic generation. These insights position RF-SOT as a promising new mechanism for future magnonic and spintronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrogen-Based Energy Storage Systems for Large-Scale Data Center Applications

Global demand for data and data access has spurred the rapid growth of the data center industry. To meet demands, data centers must provide uninterrupted service even during the loss of primary power. Service providers seeking ways to eliminate their carbon footprint are increasingly looking to clean and sustainable energy solutions, such as hydrogen technologies, as alternatives to traditional backup generators. In this viewpoint, a survey of the current state of data centers and hydrogen-based technologies is provided along with a discussion of the hydrogen storage and infrastructure requirements needed for large-scale backup power applications at data centers.

08 HYDROGEN↗

Design and Stability Analysis of Control System in Multiport Autonomous Reconfigurable Solar Power Plants (MARS)

The Multiport Autonomous Reconfigurable Solar Power Plant (MARS) is an integrated photovoltaic (PV) power generation and energy storage system (ESS), that is designed to connect to both alternating current (AC) transmission grids and high-voltage direct current (HVDC) links. It is a three-phase plant consisting of numerous components with a complex hardware and hierarchical control architecture. This paper presents an approach to decouple the multivariable system of MARS using a recursive reduced-order and boundary layer system methodology. This approach enables efficient computation of the control parameters for the Ll, L2, and L3 controllers. To validate the effectiveness of the proposed control strategy, cyclic tests in accordance with pre-defined performance criteria using controller Hardware-in-the-Loop (cHIL) experiments are conducted. The results demonstrate that the MARS system operates consistently under steady-state conditions. Furthermore, the dynamic response of the MARS system to various grid events is analyzed, underlining the resilience of MARS in presence of faults or loss of generation within the connected WECC system.

Xia, Qian↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revised monthly energy generation estimates for 1,500 hydroelectric power plants in the United States

Abstract The U.S. Energy Information Administration (EIA) conducts a regular survey (form EIA-923) to collect annual and monthly net generation for more than ten thousand U.S. power plants. Approximately 90% of the ~1,500 hydroelectric plants included in this data release are surveyed at annual resolution only and thus lack actual observations of monthly generation. For each of these plants, EIA imputes monthly generation values using the combined monthly generating pattern of other hydropower plants within the corresponding census division. The imputation method neglects local hydrology and reservoir operations, rendering the monthly data unsuitable for various research applications. Here we present an alternative approach to disaggregate each unobserved plant’s reported annual generation using proxies of monthly generation—namely historical monthly reservoir releases and average river discharge rates recorded downstream of each dam. Evaluation of the new dataset demonstrates substantial and robust improvement over the current imputation method, particularly if reservoir release data are available. The new dataset—named RectifHyd—provides an alternative to EIA-923 for U.S. scale, plant-level, monthly hydropower net generation (2001–2020). RectifHyd may be used to support power system studies or analyze within-year hydropower generation behavior at various spatial scales.

13 HYDRO ENERGY↗

Solar Canopy Expansion Project (Final Technical Report)

This project is a parking-lot canopy solar photovoltaic system, consisting of four canopy structures and 1,080 470-watt (W) modules. The nameplate rating of the project is 507.6 kilowatts direct current (kWDC) at Standard Test Condition (STC), and 448 kilowatts alternating current (kWAC). It is interconnected to the existing Tribe-owned medium-voltage micro-grid generation system via a step-up transformer and short medium-voltage line. This project offsets energy usage from more expensive existing sources, specifically the Tribe-owned gas-fired engine generators providing the primary power source for existing Tribal facilities and the electric utility, which provides an alternate source. The solar photovoltaic system is a renewable source, which has the benefit of reducing reliance on fossil-fuel burning sources. By reducing demand on existing Tribe-owned conventional generators, the project has avoided the need to add more conventional generation and has prolonged the lifespan of existing gas-fired engine generators. The project reduced energy costs and reliance on fossil-fuel burning power sources, increasing Tribe-owned generating sources and self-reliance, and prolonging the lifespan of existing generators. A side benefit to the project is the production of dozens of covered parking spaces in the existing parking lot.

14 SOLAR ENERGY↗

Attaining regularization length insensitivity in phase-field models of ductile failure

In this work, a cohesive phase-field model of ductile fracture in a finite-deformation setting is presented. The model is based on a free-energy function in which both elastic and plastic work contributions are coupled to damage. Using a strictly variational framework, the field evolution equations, damage kinetics, and flow rule are jointly derived from a scalar least-action principle. Particular emphasis is placed on the use of a rational function for the stress degradation that maintains a fixed effective strength with decreasing regularization length. The model is employed to examine crack growth in pure mode-I problems through the generation of crack growth resistance (J-R) curves. In contrast to alternative models, the current formulation gives rise to J-R curves that are insensitive to the regularization length. Numerical evidence suggests convergence of local fields with respect to diminishing regularization length as well.

42 ENGINEERING↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LLGOMAX: Enhancing Industry-Standard Tools for AC Optimal Unit Commitment (CRADA Final Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC ("LLNS"), as manager and operator of Lawrence Livermore National Laboratory ("LLNL") and ECCO International Inc. ("Participant"). The team designed and implemented a new approach for the Security-Constrained Alternating-Current Unit Commitment (SCACUC) problem. The SCACUC problem is a mathematical optimization problem that decides which generating units should be online and how much power should be produced (and consumed) at each point of the power grid. The decisions are made so as to minimize the total cost of supplying electricity while respecting technical constraints of the power grid, both under normal and emergency conditions. The team developed a solution for SCACUC as specified in the ARPA-E Grid Optimization Competition (GOC) Challenge 3, which put forth a forward-looking version of the problem, which many features not present in today’s electricity market specifications for SCACUC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scale and Regionality of Nonelectric Markets for U.S. Nuclear Light Water Reactors

This study assesses existing and potential industries that could conceivably be directly coupled to existing nuclear reactors. The goal is to identify the scale, location, and accessibility of the candidate industrial-product markets, as well as process feedstocks that are available near the plants to establish new industries. For example, CO 2 as a feedstock can be combined with H 2 to produce formic acid (FA), transportation fuels, and lubricants. These new plants can be entirely supported with the heat and electricity provided by a nearby NPP. The potential demand for nonelectric industrial products was assessed by documenting current and possible growth of nonelectricity product markets considered. This assessment used DOE- and industry-supported tools, data, and projections to capture regional industrial market opportunities. Electricity-capacity markets that reward large and reliable generators, such as NPPs, were considered because the electricity market will likely continue to be an important revenue source to NPPs. The key is to balance the needs of energy customers so as to optimize revenue for the affiliated energy customers or partners. In most cases, flexible plant energy delivery and power generation for the grid will require either energy storage or a stock of intermediate products to sustain the industrial customers when the NPP dispatches electricity to the grid. A diverse mix of temperate regions with operating NPPs around the U.S.—representing a variety of operating markets, local generation mix, and seasonal climates—were chosen for this market study. Both current and future market opportunities for candidate industrial-product markets surrounding these NPPs were studied. Figure 2 illustrates the regions chosen for this study. The success of developing nonelectric industrial-product markets as alternative revenue-generating sources for LWRs depends, not only on demand from growing existing markets, such as petroleum refining and NH 3 production, but also on the development of new markets such as light-duty (LD) and heavy-duty (HD) hydrogen FCEVs, synfuels, chemical production, biofuels, metal refining, injection of hydrogen into NG pipelines for gas power-generating units, FA, polymers, and close-coupled industrial heat applications, all of which can significantly increase demand relative to current levels while decarbonizing energy sectors. This study also presents a sample analysis of the economics of hydrogen production in an area of Minnesota, considering the capital and operating costs of a hydrogen plant as well as the local market demand for hydrogen. It includes some assumptions on electricity-grid pricing, showing how hydrogen could be integrated with an NPP and be competitive with the incumbent hydrogen-production process, steam methane reforming (SMR). The objectives of this study include: Provide U.S. NPP operators a robust sampling of the market demand location, scale, and accessibility (including storage and transportation) of the wide variety of industrial-product choices that can be produced using nuclear thermal energy and electricity proximate to a subset of U.S. NPPs to inform the industry of the potential opportunity; show examples and trade-off analyses of how U.S. LWR operators can access these markets, including storage and transportation of industrial products to their intended markets; and present a general analysis example for one industrial product (hydrogen) in one region (Minnesota area), including production, storage, and transportation, to show how nuclear-hybrid integrated energy systems (IESs) could access local markets and improve the profitability of an NPP.

03 NATURAL GAS↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Alternative Vector PWM for CSI Common-Mode Voltage Reduction During Voltage-Boost Operation with Low Modulation Index

This paper proposes a new pulse-width modulation (PWM) scheme named alternative vector PWM (AVM) algorithm that reduces the common-mode voltage (vCM) generated by a 3-phase current source inverter (CSI) during operation within a portion of its voltage-boost regime when the CSI’s modulation index is below 1/3–√(=0.5774). Three different active current vector pairs (one conventional pair with adjacent active current vectors and two proposed pairs with non-adjacent active current vectors) are used to reduce vCM based on the CSI’s output voltage conditions. Experimental results confirm significant reductions in major vCM spectral components by up to approx. 85% between the 3rd harmonic of the fundamental frequency and the CSI’s PWM frequency, validating the advantages of the proposed AVM algorithm over the conventional PWM.

42 ENGINEERING↗

Performance Limits of an Alternating Current Electroluminescent Device

Abstract The use of an alternating current (AC) voltage is a simple, versatile method of producing electroluminescence from generic emissive materials without the need for contact engineering. Recently, it was shown that AC‐driven, capacitive electroluminescent devices with carbon nanotube network contacts can be used to generate and study electroluminescence from a variety of molecular materials emitting in the infrared‐to‐ultraviolet range. Here, performance trade‐offs in these devices are studied through comprehensive device simulations and illustrative experiments, enhancing understanding of the mechanism and capability of electroluminescent devices based on alternating as opposed to direct current (DC) schemes. AC‐driven electroluminescent devices can overcome several limitations of conventional DC‐driven electroluminescent devices, including the requirement for proper alignment of material energy levels and the need to process emitting materials into uniform thin films. By simultaneously optimizing device geometry, driving parameters, and material characteristics, the performance of these devices can be tuned. Importantly, the turn‐on voltage of AC‐driven electroluminescent devices approaches the bandgap of the emitting material as the gate oxide thickness is scaled, and internally efficient electroluminescence can be achieved using low‐mobility single‐layer emitter films with varying thicknesses and energy barrier heights relative to the contact.

Wang, Vivian↗

An overview of switchgrass phenotypes variability across diverse populations and their implications for conversion to fuels

There have been substantial changes to the human lifestyle over the past two centuries, which are reflected in the amount of fuel we consume to power our day-to-day needs. The way we use these resources has indeed manifested in an overdependence on non-renewable energy sources, such as coal and petroleum, for generating electricity and powering our transportation needs. There is a pressing need to explore alternative ways of fueling our current lifestyle without impacting the environment. Biofuels have long been touted as a sustainable solution for use as drop-in fuels in aviation and maritime applications. Still, they have yet to establish themselves as a competitive commercial alternative, necessitating further research and development. Lignocellulosic biomass is an underutilized resource that is widely accessible for the commercial processing of renewable biofuels. Bioenergy crops, such as switchgrass (Panicum virgatum L.), which can be cultivated on marginal lands with minimal competition for agricultural land, are an ideal and promising candidate for bulk-scale biofuel synthesis. Over the past 30 years, significant progress has been made in breeding and genetically modifying these grasses to enhance their drought resilience and subsequent yields. However, discrepancies in biomass composition can lead to irregular feedstocks for downstream operations, which in turn affect overall production targets for biofuels. Here, this review examines the variability in switchgrass (P. virgatum L.) biomass phenotypes across diverse populations and plant components, and their implications for biofuel conversion. The study highlights significant variations in biomass yield, composition, and cell wall chemistry both between switchgrass genotypes and within individual cultivars. Key findings include differences in cellulose, hemicellulose, and lignin content between leaves and stems, which affect biomass digestibility and ethanol yield. The review also discusses the impact of lignin chemistry, particularly the syringyl/guaicyl (S/G) ratio, on the efficiency of biomass saccharification. Furthermore, it explores how these variations respond differently to various pretreatment techniques, affecting overall biofuel production. We conclude that understanding and quantifying this variability is crucial for optimizing switchgrass as a feedstock for commercial biofuel production, thereby potentially addressing the pressing need for sustainable energy sources in sectors such as aviation.

Kousika, Rohit [Univ. of Tennessee, Knoxville, TN ↗