Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANEMOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Four spot laser anemometer and optical access techniques for turbine applications

A time-of-flight anemometer (TOFA) system, utilizing a spatial lead-lag filter for bipolar pulse generation was constructed and tested. This system, called a Four Spot Laser Anemometer, was specifically designed for use in high speed, turbulent flows in the presence of walls or surfaces. The TOFA system uses elliptical spots to increase the flow acceptance angle to be comparable with that of a fringe type anemometer. The tightly focused spots used in the Four Spot yield excellent flare light rejection capabilities. Good results were obtained to 75 microns normal to a surface, with a f/2.5 collecting lens. This system is being evaluated for use in a warm turbine facility. Results from both a particle lag velocity experiment and boundary layer profiles will be discussed. In addition, an analysis of the use of curved windows in a turbine casing will be presented. Curved windows, matching the inner radius of the turbine casing, preserve the flow conditions, but introduce astigmatic aberrations. A correction optic was designed that virtually eliminates these astigmatic aberrations throughout the intrablade survey region for normal incidence.

Wernet, Mark P.↗

Four spot laser anemometer and optical access techniques for turbine applications

A time-of-flight anemometer (TOFA) system utilizing a spatial lead-lag filter for bipolar pulse generation has been constructed and tested. This system, called a four-spot laser anemometer, was specifically designed for use in high-speed, turbulent flows in the presence of walls or surfaces. The TOFA system uses elliptical spots to increase the flow acceptance angle to be comparable with that of a fringe-type anemometer. The tightly focused spots used in the four spot yield excellent flare light rejection capabilities. Good results have been obtained to 75 microns normal to a surface, with an f/2.5 collection lens. This system is being evaluated for use in a warm turbine facility. Results from both a particle-lag velocity experiment and boundary layer profiles will be discussed. In addition, an analysis of the use of curved windows in a turbine casing will be presented. Curved windows, matching the inner radius of the turbine casing, preserve the flow conditions, but introduce astigmatic aberrations. A correction optic was designed that virtually eliminates these astigmatic aberrations throughout the intrablade survey region for normal incidence.

Wernet, Mark P.↗

The K-Gill - A twin propeller-vane anemometer for measurements of atmospheric turbulence

A twin propeller-vane anemometer developed at the University of British Columbia was successfully used for unattended measurement of atmospheric turbulence over extended periods of time during moderate to high winds in the presence of sea spray. In this paper, a new design in twin propeller-vane anemometers is introduced. The instrument consists of two Gill anemometers mounted on a vane. The propeller shafts, one pointing up and the other pointing down, make an angle of 45 deg with the horizontal (hence, the name K-Gill). In addition to the desirable characteristics of the earlier design the K-Gill has symmetry, so that updraft and downdraft winds are measured with equal sensitivity. An algorithm for obtaining the vertical and downstream horizontal components of the wind velocity is described. Various sources of error and their magnitudes are discussed.

Atakturk, Serhad S.↗

Applications of hot-film anemometers in hypersonic shear layers

A wind tunnel test was conducted on a flat plate at zero angle of attack with a rearward facing 2D cooling film injector nozzle. The freestream Mach number was 8 and the injector Mach number was 3. The freestream Reynolds number varied from 0.43 to 3.3 million per ft during the test, and the injector flow rate was such that the jet exit and freestream static pressures were matched. The analysis reported herein will focus on data obtained at a freestream Reynolds number of 0.85 million per ft. The data consists of heat-transfer measurements obtained upstream and downstream of the injector nozzle and flowfield surveys obtained downstream of the injector nozzle with a pitot, total temperature, hot-film anemometer and hot-wire anemometer probes. The flowfield surveys were made at stations 0.1 to 9 in. downstream of the injector nozzle from near the model surface to approximately 2 in above the model surface. The hot-film anemometer was used to define the fluctuations in the shear layer separating the flows. The hot-film results are integrated with conventional measurement techniques to obtain a more complete description of the complicated shear layer separating hypersonic and supersonic flows.

Grubb, J. P.↗

Laser transit anemometer experiences in supersonic flow

The purpose of this paper is to present examples of velocity measurements obtained in supersonic flow fields with the laser transit anemometer system. Velocity measurements of a supersonic jet exhausting in a transonic flow field, a cone boundary survey in a Mach 4 flow field, and a determination of the periodic disturbance frequencies of a sonic nozzle flow field are presented. Each of the above three cases also serves to illustrate different modes of laser transit anemometer operation. A brief description of the laser transit anemometer system is also presented.

Hunter, William W., Jr.↗

A high-performance constant-temperature hot-wire anemometer

A high-performance constant-temperature hot-wire anemometer has been designed based on a system theory analysis that can be extended to arbitrary order. A motivating factor behind the design was to achieve the highest possible frequency response while ensuring overall system stability. Based on these considerations, the design of the circuit and the selection of components is discussed in depth. Basic operating instructions are included in an operator's guide. The analysis is used to identify operating modes, observed in all anemometers, that are misleading in the sense that the operator can be deceived by interpreting an erroneous frequency response. Unlike other anemometers, this instrument provides front panel access to all the circuit parameters which affect system stability and frequency response. Instructions are given on how to identify and avoid these rather subtle and undesirable operating modes by appropriate adjustment of the controls. Details, such as fabrication drawings and a parts list, are provided to enable others to construct the instrument.

Watmuff, Jonathan H.↗

Drag Force Anemometer Used in Supersonic Flow

To measure the drag on a flat cantilever beam exposed transversely to a flow field, the drag force anemometer (beam probe) uses strain gauges attached on opposite sides of the base of the beam. This is in contrast to the hot wire anemometer, which depends for its operation on the variation of the convective heat transfer coefficient with velocity. The beam probe retains the high-frequency response (up to 100 kHz) of the hot wire anemometer, but it is more rugged, uses simpler electronics, is relatively easy to calibrate, is inherently temperature compensated, and can be used in supersonic flow. The output of the probe is proportional to the velocity head of the flow, 1/2 rho u(exp 2) (where rho is the fluid density and u is the fluid velocity). By adding a static pressure tap and a thermocouple to measure total temperature, one can determine the Mach number, static temperature, density, and velocity of the flow.

Fralick, Gustave C.↗

A comparison of disturbance levels measured in hypersonic tunnels using a hot-wire anemometer and a pitot pressure probe.

Disturbance levels were measured in the test section of a Mach 5 blowdown jet using a constant-current, hot-wire anemometer and a pressure transducer. The disturbance levels, measured by the two instruments and normalized by local mean values, agreed within about 30%, with the pitot data higher than the hot-wire data. The rms disturbance levels measured with the hot-wire anemometer and converted to pitot pressures using a quasi-steady flow analysis, were about two-thirds the levels measured with the pitot probe. The variation of the normalized rms disturbance levels with stagnation pressure indicated that transition occurred in the boundary layer on the nozzle wall and influenced the outputs of the instruments located at the exit of the nozzle when the total pressure was about 35 N/sq cm. Below this pressure the disturbance levels decreased markedly. At higher pressures the disturbances were predominantly aerodynamic noise generated by the turbulent boundary layer on the nozzle wall.

Stainback, P. C.↗

Multipurpose miniature drag-force anemometer

Simple, rugged, accurate probe measures steady-state and dynamic flow angle, and turbulence intensity in flowing fluids at subsonic velocity. Probe is simpler in design and calibration, and more durable, than hot-wire and hot-film anemometers and is not affected by flow contamination. It is less expensive and complex than laser anemometers. Associated electronics are as simple as those of strain-gage pressure transducers.

Fralick, G. C.↗

Laser anemometer signals - Visibility characteristics and application to particle sizing

Investigations have been conducted concerning the characteristics of the visibility function as determined by the parameters of the laser anemometer system and the electromagnetic scattering properties of the particles. Experiments have been performed to evaluate the backscatter visibility of signals from a symmetric, s polarization laser anemometer as a function of the particle diameter and a parameter ratio. The results have been compared with the predictions of an analysis based on Mie's scattering theory. The analysis has also been used to evaluate the effects of the collecting aperture's size and location.

Adrian, R. J.↗

Hot-wire, laser anemometer and force balance measurements of cross-sectional planes of single and interacting trailing vortices

Single and multiple trailing vortices shed from semi-span wings and a transport model in a wind tunnel were studied by means of a laser-velocimeter, hot-wire anemometer, and a trailing model incorporating a 6-component force balance. Velocity profile and turbulence data from the laser-velocimeter and hot-wire anemometer are presented and shown to compare well with the Betz inviscid circulation model. Lift and rolling moment measurements on the following model are compared with those predicted from the flow field measurements.

Iversen, J. D.↗

Feasibility study of transit photon correlation anemometer for Ames Research Center unitary wind tunnel plan

A laser transit anemometer measured a two-dimensional vector velocity, using the transit time of scattering particles between two focused and parallel laser beams. The objectives were: (1) the determination of the concentration levels and light scattering efficiencies of naturally occurring, submicron particles in the NASA/Ames unitary wind tunnel and (2) the evaluation based on these measured data of a laser transit anemometer with digital correlation processing for nonintrusive velocity measurement in this facility. The evaluation criteria were the speeds at which point velocity measurements could be realized with this technique (as determined from computer simulations) for given accuracy requirements.

Mayo, W. T., Jr.↗

Application of split-film anemometer and mini-computer for measurement in turbulent separated flow

A split-film anemometer has been adapted for measurement of highly turbulent intermittently reversing flows in regions of local separation around airfoils and flaps. Analog signals from the split-film anemometer are fed directly to a mini-computer for processing and analysis. Mean velocity magnitude and direction, intermittency of reversal, turbulence intensity and histograms of the velocity are obtained as outputs of the system.

Wentz, W. H.↗

Laser anemometer measurements in a transonic axial flow compressor rotor

A laser anemometer system employing an efficient data acquisition technique was used to make measurements upstream, within, and downstream of the compressor rotor. A fluorescent dye technique allowed measurements within endwall boundary layers. Adjustable laser beam orientation minimized shadowed regions and enabled radial velocity measurements outside of the blade row. The flow phenomena investigated include flow variations from passage to passage, the rotor shock system, three-dimensional flows in the blade wake, and the development of the outer endwall boundary layer. Laser anemometer measurements are compared to a numerical solution of the streamfunction equations and to measurements made with conventional instrumentation.

Strazisar, A. J.↗

Dynamic behavior of a beam drag-force anemometer

A cantilevered beam with strain gages attached to the fixed ends and the minimax technique were used in an experiment conducted to determine the dynamic behavior of a drag-force anemometer in high frequency, unsteady flow. In steady flow the output of the anemometer is proportional to stream velocity head and flow angle. Fluid mechanics suggests that, in unsteady flow, the output would also be proportional to the rate of change of fluid velocity. It was determined that effects due to the rate of change of fluid velocity are negligible for the probe geometry and frequencies involved.

Fralick, G. C.↗

Efficient laser anemometer for intra-rotor flow mapping in turbomachinery

Innovative features of the anemometer include: (1) a rapid and efficient data acquisition process, (2) a detailed real-time graphic display of the data being accumulated, and (3) input laser beam positioning that maximizes the size of the intra-rotor region being mapped. Results demonstrate the anemometer's capability in flow mapping within a transonic axial-flow compressor rotor. The use of fluorescent seed particles allows flow measurements near the rotor hub and the casing window.

Powell, J. A.↗

Comparison of surface wind stress measurements - Airborne radar scatterometer versus sonic anemometer

Sea surface wind stress measurements recorded by a sonic anemometer are correlated with airborne scatterometer measurements of ocean roughness (cross section of radar backscatter) to establish the accuracy of remotely sensed data and assist in the definition of geophysical algorithms for the scatterometer sensor aboard Seasat A. Results of this investigation are as follows: Comparison of scatterometer and sonic anemometer wind stress measurements are good for the majority of cases; however, a tendency exists for scatterometer wind stress to be somewhat high for higher wind conditions experienced in this experiment (6-9 m/s). The scatterometer wind speed algorithm tends to overcompute the higher wind speeds by approximately 0.5 m/s. This is a direct result of the scatterometer overestimate of wind stress from which wind speeds are derived. Algorithmic derivations of wind speed and direction are, in most comparisons, within accuracies defined by Seasat A scatterometer sensor specifications.

Brucks, J. T.↗

High-speed laser anemometer system for intrarotor flow mapping in turbomachinery

A fringe-type laser anemometer with innovative features is described. The innovative features include: (1) rapid, efficient data acquisition processes, (2) detailed graphic display of data being accumulated, and (3) input laser-beam positioning that allows greater optical access to the intrarotor region. Results are presented that demonstrate the anemometer's capability in flow mapping within a transonic axial-flow compressor rotor.

Powell, J. A.↗