Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANOVA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Validation of Cardiovascular Parameters During NASA's Functional Task Test

Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures in the prone position and stand test were less than 8% for the test sessions. ANOVA results yielded a greater inter-subject variability (p.0.006) than inter-session variability (p>0.05) for HRV in the stand test. CONCLUSION: These studies show that a 3 minute stand delivers repeatable cardiovascular heart rate and BP data in the context of this larger series of tests such as the FTT.

Arzeno, N. M.↗

Validation of Cardiovascular Parameters during NASA's Functional Task Test

Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p<0.006) than inter-session variability (p>0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight rest and stand values. Postflight HRV showed higher LF/HF for rest and stand and lower HFnu during rest. CONCLUSION: These studies show that a 3 min stand delivers repeatable HRV data in the context of this larger series of FTT tests. Spaceflight-induced changes in blood pressure, RR and autonomic function (HRV) are evident from the RFST.

Arzeno, N. M.↗

Finite Element Model Calibration Approach for Ares I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of nonconventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pre-test predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

Finite Element Model Calibration Approach for Area I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of non-conventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pretest predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

On-Orbit Prospective Echocardiography on International Space Station Crew

Introduction A prospective trial of echocardiography was conducted on of six crewmembers onboard the International Space Station. The main objective was to determine the efficacy of remotely guided tele-echocardiography, including just-in-time e-training methods and determine what "space normal" echocardiographic data is. Methods Each crewmember operator (n=6) had 2-hour preflight training. Baseline echocardiographic data were collected 55 to 167days preflight. Similar equipment was used in each 60-minute in-flight session (mean microgravity exposure - 114 days (34 -- 190)). On Orbit ultrasound operators used an e-learning system within 24h of these sessions. Expert assistance was provided using ultrasound video downlink and two-way voice. Testing was repeated 5 to 16 days after landing. Separate ANOVA was used on each echocardiographic variable (n=33). Within each ANOVA, three tests were made: a) effect of mission phase (preflight, in-flight, post flight); b) effect of echo technician (two technicians independently analyzed the data); c) interaction between mission phase and technician. Results Nine rejections of the null hypothesis (mission phase or technician or both had no effect) were discovered and considered for follow up. Of these, six rejections were for significant technician effects, not as a result of space flight. Three rejections of the null hypothesis (Aortic Valve time velocity integral, Mitral E wave Velocity and heart rate) were attributable to space flight, however determined not to be clinically significant. No rejections were due to the interaction between technician and space flight. Conclusion No consistent clinically significant effects of long-duration space flight were seen in echocardiographic variables of the given group of subjects.

Hamilton, Douglas R.↗

SMAR Sessions

This slide presentation is a series of educational presentations that are on the statistical function of analysis of variance (ANOVA). Analysis of Variance (ANOVA) examines variability between groups, relative to within groups, to determine whether there's evidence that the groups are not from the same population. One other presentation reviews hypothesis testing.

Ploutz-Snyder, Robert↗

Direct Relationship Between Perceptual and Motor Variability

The time that elapses between stimulus onset and the onset of a saccadic eye movement is longer and more variable than can be explained by neural transmission times and synaptic delays (Carpenter, 1981, in: Eye Movements: Cognition & Visual Perception, Earlbaum). In theory, noise underlying response-time (RT) variability could arise at any point along the sensorimotor cascade, from sensory noise arising Vvithin the early visual processing shared Vvith perception to noise in the motor criterion or commands necessary to trigger movements. These two loci for internal noise can be distinguished empirically; sensory internal noise predicts that response time Vvill correlate Vvith perceived stimulus magnitude whereas motor internal noise predicts no such correlation. Methods. We used the data described by Liston and Stone (2008, JNS 28:13866-13875), in which subjects performed a 2AFC saccadic brightness discrimination task and the perceived brightness of the chosen stimulus was then quantified in a second 21FC perceptual task. Results. We binned each subject's data into quartiles for both signal strength (from dimmest to brightest) and RT (from slowest to fastest) and analyzed the trends in perceived brightness. We found significant effects of both signal strength (as expected) and RT on normalized perceived brightness (both p less than 0.0001, 2-way ANOVA), without significant interaction (p = 0.95, 2-way ANOVA). A plot of normalized perceived brightness versus normalized RT show's that more than half of the variance was shared (r2 = 0.56, P less than 0.0001). To rule out any possibility that some signal-strength related artifact was generating this effect, we ran a control analysis on pairs of trials with repeated presentations of identical stimuli and found that stimuli are perceived to be brighter on trials with faster saccades (p less than 0.001, paired t-test across subjects). Conclusion. These data show that shared early visual internal noise jitters perceived brightness and the saccadic motor output in parallel. While the present correlation could theoretically result, either directly or indirectly, from some low-level brainstem or retinal mechanism (e.g., arousal, pupil size, photoreceptor noise) that influences both visual and oculomotor circuits, this is unlikely given the earlier fin ding that the variability in perceived motion direction and smooth-pursuit motor output is highly correlated (Stone and Krauzlis, 2003, JOV 3:725-736), suggesting that cortical circuits contribute to the shared internal noise.

Liston, Dorion B.↗

Overexpression of Catalase in Mitochondria Mitigates the Effects of Simulated Microgravity and Social Isolation on Cytokine Expression in Mouse Hippocampus

Space flight missions are becoming longer and more common and evidence points to the physiological toll the missions have on the human body. Aging, sedentary lifestyle, and spaceflight have similar degenerative effects on almost every part of our body; both exposure to the space environment and aging result in cardiovascular deconditioning, bone loss, muscle atrophy, brain changes, and immune response impairment. We hypothesize that exposure to the space environment generates excessive Reactive Oxygen Species (ROS), which results in neuroinflammation and aging-like degenerative symptoms in the brain. We used the hindlimb unloading (HU) model to mimic microgravity with either paired or single housed animals (social isolation). Responses to 30d (30 days) of HU were compared in wildtype or transgenic MCAT (Mitochondrial-targeted CATalase) mice, in which mitochondrial ROS is quenched by over-expression of human catalase. Expression of 4-Hydroxynonenal (4HNE) and Park7 (redox-sensitive chaperone and sensor of oxidative stress) were measured by ELISA (Enzyme-Linked ImmunoSorbent Assay), a protein array quantified from the hippocampal cytokines and 8-hydroxy-2'-deoxyguanosine in serum was measured by ELISA to assess oxidative DNA damage. Preliminary analysis of cage behavior patterns from video collected at the end of the study showed that MCAT HU mice (socially housed) were more active and conducted more exploratory activities compared to NL (Normally Loaded). Our biochemical results showed simulated microgravity and/or social isolation caused changes in levels of cytokines related to immune responses. Two-way ANOVA (Analysis of Variance) revealed significant interaction effects of HU and genotype in expression levels of five cytokines (out of 35) in socially-housed animals. Elevation of these generally pro-inflammatory cytokines by HU in WT (Wild Type) mice was mitigated in MCAT mice, suggesting a role for mitochondrial ROS signaling in inflammatory CNS (Central Nervous System) responses to microgravity. Interestingly, some of these cytokines in the hippocampus displayed strong correlations to the 4HNE levels. We also found substantive cytokine responses to social isolation in the hippocampus; housing and genotype interaction effects were significant (by 2-Factor ANOVA) for 15 cytokines, most of which were mitigated in MCAT mice.Taken together, our results showed that both simulated microgravity and social isolation influenced cytokine levels in the hippocampus and MCAT mice were at least partially protected from these changes. These findings implicate a potentially important role for mitochondrial ROS in CNS responses to the challenges posed by long duration spaceflight.

MCAT↗

Analysis of the quality of image data acquired by the LANDSAT-4 Thematic Mapper and Multispectral Scanners

The geometric quality of TM film and digital products is evaluated by making selective photomeasurements and by measuring the coordinates of known features on both the TM products and map products. These paired observations are related using a standard linear least squares regression approach. Using regression equations and coefficients developed from 225 (TM film product) and 20 (TM digital product) control points, map coordinates of test points are predicted. The residual error vectors and analysis of variance (ANOVA) were performed on the east and north residual using nine image segments (blocks) as treatments. Based on the root mean square error of the 223 (TM film product) and 22 (TM digital product) test points, users of TM data expect the planimetric accuracy of mapped points to be within 91 meters and within 117 meters for the film products, and to be within 12 meters and within 14 meters for the digital products.

Colwell, R. N.↗

Impact of Thematic Mapper Sensor Characteristics on Classification Accuracy

A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, D.C. each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.

Williams, D. L.↗

Quick Look Analysis of TM Data of the Washington, District of Columbia Area

A fixed factor analysis-of-variance (ANOVA) approach was used to quantify the impact of each TM sensor characteristic (spectral, spatial, and radiometric resolutions) on classification accuracy. All assessments were made relative to MSS sensor characteristics, and the impact of each characteristic was assessed individually, and in all possible combinations. Thematic Mapper data acquired over the Washington, D.C. area on November 2, 1982 were utilized to conduct the experiment. The following results were obtained: the reduction of quantization level from eight bits to six bits caused a decrease in overall accuracy (7%); the use of only three bands (TM 2, 3 and 4) covering the isible and near infrared portion of the spectrum caused a decrease in overall accuracy (7%); and the decrease in spatial resolution resulted in an increase in overall accuracy (4%). Results indicate that the increased radiometric and spectral resolution of the TM instrument do provide increased information content. The result of the spatial resolution degradation is somewhat misleading, in that the result is more a function of spatial resolution.

Williams, D. L.↗

Impact of Thematic Mapper Sensor Characteristics on Classification Accuracy

A fixed effect, three factor (two levels per factor) analysis of variance was used to quantitatively assess the significance of the improved spectral, spatial and radiometric resolution capabilities of the LANDSAT-4 thematic mapper sensor relative to the familiar MSS sensor. TM data acquired over the Washington, D.C. area were progressively degraded in spectral, spatial and radiometric characteristics to simulate the MSS, and classification accuracies were derived in a consistent manner for all eight treatments in the ANOVA design. Statistical testing of the significance of differences in classification accuracies between treatments indicated that the increased number of spectral bands and the improved quantization capabilities afforded by the TM sensor design would lead to significant improvements in classification accuracies attainable relative to MSS. In contrast, however, the improved spatial resolution provided by the TM sensor did not enhance classification accuracy. This latter result was felt to be more a function of the type of classification algorithms available.

Williams, D. L.↗

Impact of thematic mapper sensor characteristics on classification accuracy

A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, DC, each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30 m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.

Williams, D. L.↗

The effects of sensor advancements on Thematic Mapper data classification

Analyses of Landsat Thematic Mapper (TM) data were conducted to assess the effects of sensor advancements on the thematic classification of remote sensing data. The effects of altering three sensor characteristics (spatial resolution, data quantization, and spectral band configuration) from Landsat Multispectral Scanner (MSS) specifications were investigated using analysis-of-variance (ANOVA). Analyses were conducted on data from two TM scenes: Washington, D.C. (late autumn) and western Pennsylvania (late summer). Results indicate that the contribution of sensor advancements to thematic classification are highly dependent of spectral and spatial scene attributes.

Irons, J. R.↗

Spatial characterization of acid rain stress in Canadian Shield Lakes

An analysis was performed to interpret the spatial aspects of lake acidification. Three types of relationships were investigated based upon the August to May seasonal scene pairing. In the first type of analysis ANOVA was used to examine the mean Thematic Mapper band one count by ecophysical strata. The primary difference in the two ecophysical strata is the soil type and depth over the underlying bedrock. Examination of the August to May difference values for TM band one produced similar results. Group A and B strata were the same as above. The third type of analysis examined the relationship between values of the August to May difference from polygons which have similar ecophysical properties with the exception of sulfate deposition. For this case lakes were selected from units with sandy soils over granitic rock types and the sulfate deposition was 1.5 or 2.5 g/sq m/yr.

Tanis, Fred J.↗

The use of underwater dynamometry to evaluate two space suits

Four Astronauts were instrumented and donned one of three extravehicular activity (EVA) suits: the currently in use shuttle suit (STS), the Mark III (MK3), and the AX5. The STS was used as the comparison suit because of approved status. Each subject performed ten different exercises in each suit in three different manners (static, dynamic and fatigue) in two different environments, WETF and KC-135 (KC-135 not completed as of this report). Data were recorded from a flight qualified underwater dynamometer (Cybex power head) with a TEAC multichannel recorder/tape and downloaded into the VAX computer system for analysis. Also direct hard copy strip chart recordings were made for backup comparisons. Data were analyzed using the ANOVA procedure and results were graphed and reported without interpretation to the NASA/JSC ABL manager.

Squires, W. G.↗

Eccentric and concentric muscle performance following 7 days of simulated weightlessness

Changes in skeletal muscle strength occur in response to chronic disuse or insufficient functional loading. The purpose of this study was to examine changes in muscle performance of the lower extremity and torso prior to and immediately after 7 days of simulated weightlessness (horizontal bed rest). A Biodex was used to determine concentric and eccentric peak torque and angle at peak torque for the back, abdomen, quadriceps, hamstring, soleus, and tibialis anterior. A reference angle of 0 degrees was set at full extension. Data were analyzed by ANOVA.

Hayes, Judith C.↗

Systematic methods for knowledge acquisition and expert system development

Nine cooperating rule-based systems, collectively called AUTOCREW, were designed to automate functions and decisions associated with a combat aircraft's subsystem. The organization of tasks within each system is described; performance metrics were developed to evaluate the workload of each rule base, and to assess the cooperation between the rule-bases. Each AUTOCREW subsystem is composed of several expert systems that perform specific tasks. AUTOCREW's NAVIGATOR was analyzed in detail to understand the difficulties involved in designing the system and to identify tools and methodologies that ease development. The NAVIGATOR determines optimal navigation strategies from a set of available sensors. A Navigation Sensor Management (NSM) expert system was systematically designed from Kalman filter covariance data; four ground-based, a satellite-based, and two on-board INS-aiding sensors were modeled and simulated to aid an INS. The NSM Expert was developed using the Analysis of Variance (ANOVA) and the ID3 algorithm. Navigation strategy selection is based on an RSS position error decision metric, which is computed from the covariance data. Results show that the NSM Expert predicts position error correctly between 45 and 100 percent of the time for a specified navaid configuration and aircraft trajectory. The NSM Expert adapts to new situations, and provides reasonable estimates of hybrid performance. The systematic nature of the ANOVA/ID3 method makes it broadly applicable to expert system design when experimental or simulation data is available.

Belkin, Brenda L.↗