An APD for the efficient detection of the fast scintillation component of BaF2
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
We introduce a counting system of up to 500 MHz for synchrotron x-ray high-rate measurements. A silicon avalanche photodiode detector was used in the counting system. The fast-pulse circuit of the amplifier was designed with hybrid ICs to prepare an ASIC system for a large-scale pixel array detector in near future. The fast amplifier consists of two cascading emitter-followers using 10-GHz band transistors. A count-rate of 3.25x10{sup 8} s{sup -1} was then achieved using the system for 8-keV x-rays. However, a baseline shift by adopting AC-coupling in the amplifier disturbed us to observe the maximum count of 4.49x10{sup 8} s{sup -1}, determined by electron-bunch filling into a ring accelerator. We also report that an amplifier with a baseline restorer was tested in order to keep the baseline level to be 0 V even at high input rates.
This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of Muon Piston Calorimeter Extension (MPC-EX) Collaboration who have committed to participate in beam tests to be carried out during the 2013- 2014 Fermilab Test Beam Facility program.
We measure the ability of the Leonardo Selex Advanced Photodiode HgCdTe Infrared Array (SAPHIRA) avalanche photodiode array to perform photon counting. The current SAPHIRA arrays achieve >90% single-photon efficiency (independent of quantum efficiency expected to be also >90%) and a time resolution of 125 μs with a dark current of 21e {sup −} s{sup −1} pix{sup −1}. Our characterization of several iterations of the SAPHIRA detector over the past 3 years of its development have also revealed a broader pulse height distribution than was originally expected.
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169 K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
Explore the source record for details and available documents.
Abstract Not Provided
Explore the source record for details and available documents.
Abstract not provided.
With gradually increasing enhancing population and industrialization, exploitation of shale gas is enhancing in the world to satisfy the growing demand for energy worldwide. To exploit shale gas efficiently, accurate assessment of shale gas in place (GIP) is necessary for determining production strategies. Unlike free and dissolved gas, adsorbed gas contributes to the shale GIP up to 85% due to the well-developed surface area and micropores. Measured excess adsorption of methane (up to over 95% of subsurface shale gas) is often corrected to absolute adsorption to obtain the actual amount of adsorption under supercritical (or geological) conditions. During the correction, adsorption phase density (APD) is critical. However, the APD of subsurface shale gas and the effects of shale properties (e.g., mineralogy and pore structure) on APD remain poorly understood. A series of high-pressure methane adsorption isotherms (HPMAI) on Caney Shales were collected and analyzed in conjunction with other United States and Chinese shales from the literature at 35–125 °C and up to 15 MPa. Here, a three-layer Ono–Kondo (OK3) model is utilized to derive the temperature- and pressure-dependent APD coupling low-pressure nitrogen adsorption isotherms (LPNAI) and HPMAI. X-ray diffraction and organic geochemistry are combined to reveal the mineralogy. Brunauer–Emmett–Teller, Barrett–Joyner–Halenda, and Horvath–Kawazoe analyses via LPNAI are used to investigate the pore structures. Results show that APD increases with organic matter (OM) proxied by total organic carbon and decreases with clay minerals and the sum of quartz and feldspar. OM dramatically contributes to the APD as multiple-layer adsorption exists, and the APD for OM could be 1.4–8.5 times that for clay minerals. Other inorganic minerals contribute less to APD. The properties and constitution of the surface area instead of the volume fraction contribute to the APD in shales. APD does not show an obvious correlation with micropore volume, likely related to the ratio of micropore volume to the total pore volume. Here, we provide a significant and comprehensive study of petrological factors that impact the APD of subsurface shale gas, which will improve the estimation of supercritical adsorption and shale GIP under reservoir conditions. Also, the findings in this work can provide applications for subsurface carbon dioxide adsorption and storage.
Al 0.6 Ga 0.4 N deep‐UV p–i–n avalanche photodiodes (APDs) are demonstrated grown by metalorganic chemical vapor deposition (MOCVD) on a (0001) c‐plane aluminum nitride (AlN) bulk substrate and fabricated both with and without an ion implantation process for mesa‐edge electric‐field termination. Three design considerations are taken into account: the optical absorption of the AlN bulk substrate, the photosensitivity of the APD, and the breakdown electric field. The MOCVD growth conditions of the AlGaN APD layers are optimized. Then, a detailed description of the seven device fabrication steps of the APDs is provided, which includes nitrogen ion implantation. The APDs fabricated by the ion implant process exhibit a dark‐current density under low reverse bias ≈1 × 10 −9 A cm −2 . This is one order of magnitude lower than the APD fabricated without ion implantation from the same wafer. The breakdown voltage of the APD is ≈−140 V. The calculated optical gain of the ion‐implanted APD beyond avalanche breakdown is ≈5.2 × 10 5 (current limited) and the device has an average zero‐bias photoresponse of ≈68 mA W −1 at a wavelength of 250 nm.
Polychlorinated biphenyls (PCBs) have been known as serious persistent organic pollutants (POPs), causing developmental delays and motor dysfunction. We have investigated the effects of two PCB congeners, 3,3′,4,4′-tetrachlorobiphenyl (PCB 77) and 3,3′,4,4′,5-pentachlorobiphenyl (PCB 126) on ECG, action potential, and the rapidly activating delayed rectifier K{sup +} current (I{sub Kr}) of guinea pigs' hearts, and hERG K{sup +} current expressed in Xenopus oocytes. PCB 126 shortened the corrected QT interval (QTc) of ECG and decreased the action potential duration at 90% (APD{sub 90}), and 50% of repolarization (APD{sub 50}) (P < 0.05) without changing the action potential duration at 20% (APD{sub 20}). PCB 77 decreased APD{sub 20} (P < 0.05) without affecting QTc, APD{sub 90}, and APD{sub 50}. The PCB 126 increased the I{sub Kr} in guinea-pig ventricular myocytes held at 36 °C and hERG K{sup +} current amplitude at the end of the voltage steps in voltage-dependent mode (P < 0.05); however, PCB 77 did not change the hERG K{sup +} current amplitude. The PCB 77 increased the diastolic Ca{sup 2+} and decreased Ca{sup 2+} transient amplitude (P < 0.05), however PCB 126 did not change. The results suggest that PCB 126 shortened the QTc and decreased the APD{sub 90} possibly by increasing I{sub Kr}, while PCB 77 decreased the APD{sub 20} possibly by other modulation related with intracellular Ca{sup 2+}. The present data indicate that the environmental toxicants, PCBs, can acutely affect cardiac electrophysiology including ECG, action potential, intracellular Ca{sup 2+}, and channel activity, resulting in toxic effects on the cardiac function in view of the possible accumulation of the PCBs in human body. -- Highlights: ► PCBs are known as serious environmental pollutants and developmental disruptors. ► PCB 126 shortened QT interval of ECG and action potential duration. ► PCB 126 increased human ether-a-go-go-related K{sup +} current and I{sub Kr}. ► PCB 77 decreased action potential duration and increased intracellular Ca{sup 2+} content. ► PCBs acutely change cardiac electrophysiology and rhythmicity.
A top-illuminated deep-ultraviolet Al 0.6 Ga 0.4 N p-i-n avalanche photodiode (APD) structure was designed and grown by metalorganic chemical vapor deposition on an AlN bulk substrate and on two different quality AlN/sapphire templates, and APDs were fabricated and tested. The APD devices with a circular diameter of 20 μm have demonstrated a distinctive reverse-bias breakdown behavior. The reverse breakdown voltage of the APDs is approximately -140 V, which corresponds to a breakdown electric field of 6–6.2 MV/cm for the Al 0.6 Ga 0.4 N material as estimated by Silvaco TCAD simulation. The APDs grown on the AlN bulk substrate show the lowest leakage current density of < 1 × 10 -8 A/cm 2 (at low reverse bias) compared to that of the devices grown on the AlN templates. From the photocurrent measurement, a maximum gain (current limited) of 1.2 × 10 4 is calculated. The average temperature coefficients of the breakdown voltage are negative for APD devices fabricated from both the AlN bulk substrate and the AlN templates, but these data show that the coefficient is the least negative for the APD devices grown on the low-dislocation-density AlN bulk substrate.
The kinetics of formation and growth of ordered antiphase domains (APDs) in titanium carbohydride TiC{sub 0.50}H{sub 0.21} has been investigated by neutron diffraction. A model of ordered APDs is proposed. It is established that the pronounced ordering of interstitial atoms and APDs begin at 450°C. It is shown that the period of ordered APDs (P ≈ 10–12) is independent of the exposure time at a constant temperature. It is found that the temperature of ordered APDs, T{sub OAPD}, increases nonlinearly with an increase in the carbon concentration in the range 0.50 ≤ C/Ti ≤ 0.70. The formation temperature of ordered APDs is found to correlate with the concentration dependence of the order–disorder transition temperature and be 0.60 of the order–disorder transition temperature: T{sub APD} = 0.60Τ{sub C}.
In this paper, a four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm 2 and an absorption layer thickness of 110 μ m. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. Finally, for the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.
Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever possible. Novel calibration processes have been made possible with an insertable integrating sphere (ISIS), using an avalanche photodiode (APD) as a reference detector and optical parametric oscillator (OPO). Discussed are a novel in situ spatial calibration with the use of the ISIS, the use of an APD as a reference detector to streamline the APD calibration process, a standard dc spectral calibration, and in situ pulsed spectral calibration made possible with a combination of an OPO as a light source, the ISIS, and an APD used as a reference detector. In addition a relative quantum efficiency curve for the APDs is obtained to aid in uncertainty analysis.