A quick glance at selected topics in this issue [v. 26(2), 15 Apr 2019]
“A quick glance at selected topics in this issue” aims to highlight contents of the Journal and provide a quick review to the readers.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
“A quick glance at selected topics in this issue” aims to highlight contents of the Journal and provide a quick review to the readers.
Continued monitoring of the Buckman Direct Diversion and Los Alamos County Water Supply Wells; Groundwater Protection - Continued implementation of the Interim Facility-Wide Groundwater Monitoring Plan (IFGMP); Surface Water Protection - Continued protection of surface water through implementation of the Individual Stormwater Permit (IP); Buckman Early Notification System operability at 100% per MOU Requirements.
Our main activity this quarter was focused on carrying out the data analysis following the experimental campaign conducted at the Irradiated Fuel Examination Laboratory (IFEL) at ORNL. More specifically, we focused on the demonstration of hard X-rays two reflections, as well as the quantification of the background reduction and signal-to-noise-ratio (SNR) under different experimental conditions. Significant time and effort was spent developing data analysis tools using the Root software toolkit, and carefully checking data consistency across data sets and with simulations. Some results are presented below.
Cybersecurity is essential for interoperable power systems and transportation infrastructure in the US. As the US transitions to transportation electrification, cyber attacks on vehicle charging could impact nearly all US critical infrastructure. This is a growing area of concern as more charging stations communicate to a range of entities (grid operators, vehicles, OEM vendors, etc.), as shown in Figure I.1.1.1. The research challenges are extensive and complicated because there are many end users, stakeholders, and software and equipment vendors. Poorly implemented electric vehicle supply equipment (EVSE) cybersecurity is a major risk to electric vehicle (EV) adoption because the political, social, and financial impact of cyberattacks—or public perception of such—ripples across the industry and has lasting and devastating effects. Unfortunately, there is no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. For this reason, there is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured interfaces. Thus, comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project is providing the automotive industry with a strong technical basis for securing this infrastructure by developing threat models, prioritizing technology gaps, and developing effective countermeasures. Specifically, the team is creating a cybersecurity threat model and performing a technical risk assessment of EVSE assets, so that automotive, charging, and utility stakeholders can better protect customers, vehicles, and power systems in the face of new cyber threats.
This is a powerpoint presentation designed to update the Technical Coordination Team (TCT) associated with the AGR irradiation experiment program on operations of the AGR-5/6/7 experiment over the past six months (since the last TCT meeting). The presentation primarily deals with operational challenges to failed fuel particles in capsule 1. Specifically, how to keep fission products from capsule 1 from entering the other four capsules in the experiment.
Sandia National Laboratories (SNL) is a multi-purpose engineering and science laboratory owned by the U.S. Department of Energy (DOE)/National Nuclear Security Administration. SNL is managed and operated by Sandia Corporation (Sandia), a wholly-owned subsidiary of Lockheed Martin Corporation. Sandia National Laboratories, New Mexico (SNL/NM) is located within the boundaries of Kirtland Air Force Base (KAFB), southeast of the City of Albuquerque in Bernalillo County, New Mexico. The Mixed Waste Landfill (MWL) is located 4 miles south of SNL/NM central facilities and 5 miles southeast of Albuquerque International Sunport, in the north-central portion of Technical Area (TA)-III. The MWL disposal area comprises 2.6 acres. During operations, the MWL accepted containerized and other low-level radioactive waste and minor amounts of mixed waste from SNL/NM research facilities and off-site DOE and U.S. Department of Defense generators from March 1959 to December 1988. More specific information regarding the MWL inventory and past disposal practices is presented in the MWL Phase 2 RCRA Facility Investigation Report (Peace et al. September 2002) and the extensive MWL Administrative Record.
Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.
National Center for Nuclear Security (NCNS) samples were irradiated on Godiva. Fission chamber testing for NCNS was conducted on Flat-Top. This operation involved multiple core configuration changes, which doubled as important training opportunities for NEN-2 Crew Member Trainees. These experiments support nuclear forensics research.
Traditional batteries are composed of two-dimensional films that are stacked and/or rolled. Thin film batteries display high power density while their thick film counterparts show good energy density, but it has proven difficult to concurrently achieve both within these planar form factors. In addition, conventional Li-ion batteries based on liquid organic electrolytes or gel polymer electrolytes have raised severe safety concerns due to the intrinsic flammable properties of the organic electrolytes. They are also not ideal for the use of high energy density metallic lithium (Li) anodes due to Li dendrite growth, or sulfur cathodes due to shuttling effects that result in fast capacity fade. There is an urgent need to develop safe, high-performance solid-state batteries (SSBs) with advanced electrolyte and separator technologies. Although in recent years a series of superionic conductors have been developed for electrolytes and separators, their performance does not satisfy demanding criteria due to large impedance from poor solid electrolyte-electrode contact and questionable electrochemical and mechanical stability. Unlike the well-established roll-to-roll fabrication of conventional Li-ion batteries, the processing of SSBs is unique due to the brittleness of solid-state electrolytes (SSEs). The commercially available or lab-developed SSE discs are usually very thick (hundreds of micrometers to millimeters) to overcome their brittle nature, which unfortunately increases the cell impedance and accounts for the majority of the overall cell weight and volume, leading to dramatically decreased power and energy densities. In this project, we will investigate 3D printing techniques to overcome safety, fabrication, mechanical, and electrochemical issues in SSBs. 3D printing builds complex structures in a layer-by-layer fashion, which allows rapid production of hierarchical architectures, gradient and multi-material structures, and multi-component assemblies. 3D printing is an emerging area that could fundamentally transform energy storage devices. For example, 3D printing can produce batteries with arbitrary form factors to fit a product’s specific volume requirements and can create interwoven electrode arrangements over a wide range of length scales to improve transport and increase power density for a given energy density. For SSBs, 3D printing may dramatically reduce the separator thickness from ~1 mm (by hydraulic pressing) to tens of micrometers or less. In addition, the interfacial contact area between the electrolyte and the electrode may be increased via 3D interdigitated designs. Hence, we expect a significant reduction of the overall cell impedance and enhancement of both energy and power densities of SSBs by harnessing an array of 3D printing technologies being developed at Lawrence Livermore National Laboratory (LLNL).
Abstract not provided.
Abstract not provided.
Abstract not provided.
Advanced SPARCS Training Workshop in Chile April 9-12, 2018.
Advanced SPARCS Training Workshop in Chile April 9-12, 2018.
Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)
The project was based on the research of the history of the emergency use air purifying respirators (APRs) in TRA-670. Interviews, inspections, and document reviews were conducted. The interviews, inspections, and documents revealed that there were no current documents as to why the emergency use APRs were placed into TRA-670. The APRs were placed into green emergency boxes and stashed around the plant. Though they are checked to ensure they are not messed with, they have not been cleaned or re-verified since 2016 (some since 2014). When interviewees were asked, in an emergency, when they would reach for an APR over an emergency use SCBA, the consensus was that they would not. They would evacuate the facility as quickly as possible. If emergency respiratory protection were needed, a SCBA would be used. This is because, in an emergency scenario, one would not know what is in the air, so the utilization of a SCBA would be the safest option. Overall, the recommendation would be for the removal of the emergency use APRs.