Search NASA⌕ Search

SEARCH · Search NASA

Results for “ASTRONOMICAL PHOTOMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Subtleties in the flat-fielding of charge-coupled device /CCD/ images

Astronomical photometry with CCDs will often involve relatively low signal levels (less than 1000 charge carriers per pixel), at which nonlinear effects sometimes become significant. These effects will probably play a role in the processing of Space Telescope data. The problem apparently arises because signal charges are not read out equally completely from all columns and all pixels. It is shown that, although a first-order correction can be made by subtracting a low-level flat field from all frames before conventional processing, higher accuracy can be achieved by modeling the response with a nonlinear function.

Baum, W. A.↗

The Hubble Space Telescope high speed photometer

The Hubble Space Telescope will provide the opportunity to perform precise astronomical photometry above the disturbing effects of the atmosphere. The High Speed Photometer is designed to provide the observatory with a stable, precise photometer with wide dynamic range, broad wavelenth coverage, time resolution in the microsecond region, and polarimetric capability. Here, the scientific requirements for the instrument are examined, the unique design features of the photometer are explored, and the improvements to be expected over the performance of ground-based instruments are projected.

Vancitters, G. W., Jr.↗

Design and Specification of Optical Bandpass Filters for Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS)

Advanced optical bandpass filters for the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) have been developed on a filter-by-filter basis through detailed studies which take into account the instrument's science goals, available optical filter fabrication technology, and developments in ACS's charge-coupled-device (CCD) detector technology. These filters include a subset of filters for the Sloan Digital Sky Survey (SDSS) which are optimized for astronomical photometry using today's charge-coupled-devices (CCD's). In order for ACS to be truly advanced, these filters must push the state-of-the-art in performance in a number of key areas at the same time. Important requirements for these filters include outstanding transmitted wavefront, high transmittance, uniform transmittance across each filter, spectrally structure-free bandpasses, exceptionally high out of band rejection, a high degree of parfocality, and immunity to environmental degradation. These constitute a very stringent set of requirements indeed, especially for filters which are up to 90 mm in diameter. The highly successful paradigm in which final specifications for flight filters were derived through interaction amongst the ACS Science Team, the instrument designer, the lead optical engineer, and the filter designer and vendor is described. Examples of iterative design trade studies carried out in the context of science needs and budgetary and schedule constraints are presented. An overview of the final design specifications for the ACS bandpass and ramp filters is also presented.

Leviton, Douglas B.↗

Photometric Calibration of Consumer Video Cameras

Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to analyze. The light source used to generate the calibration images is an artificial variable star comprising a Newtonian collimator illuminated by a light source modulated by a rotating variable neutral- density filter. This source acts as a point source, the brightness of which varies at a known rate. A video camera to be calibrated is aimed at this source. Fixed neutral-density filters are inserted in or removed from the light path as needed to make the video image of the source appear to fluctuate between dark and saturated bright. The resulting video-image data are analyzed by use of custom software that determines the integrated signal in each video frame and determines the system response curve (measured output signal versus input brightness). These determinations constitute the calibration, which is thereafter used in automatic, frame-by-frame processing of the data from the video images to be analyzed.

Suggs, Robert↗

Ultraviolet photometry with the Astronomical Netherlands Satellite /ANS/ Observations of Beta Canis Majoris variables

The paper deals with detailed ANS observations of three Beta Canis Majoris variables: Xi-1 CMa, HD 61068 (whose discovery is reported here) and 15 CMa. Light curves at five ultraviolet wavelengths are presented, and the periods and amplitudes are discussed. The ultraviolet colors are used to derive temperatures and temperature variations, which are compared with the MK spectral types. The anomalously high luminosity found for Xi-1 CMa on the basis of certain line strengths is also discussed.

Lesh, J. R.↗

Ultraviolet photometry with the Astronomical Netherlands Satellite /ANS/ - Faint blue stars in the halo

Blue stars at high galactic latitudes have been observed with the UV telescope on board ANS. In this paper a subset of the collected data pertaining to the cooler stars is discussed. Most of them have energy distributions in general agreement with the visual spectral type. One star is exceptionally blue, and of seven possible horizontal-branch stars, two have UV energy distributions distinct from main-sequence stars in the sense that they have an excess at 1550 A and a large Balmer jump.

De Boer, K. S.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. VII alpha squared Canum Venaticorum.

Far-ultraviolet photometry by OAO-2 is presented for alpha squared CVn covering the entire 5.47-day period of this magnetic Ap variable. The light curves ranging from 1330 to 3320 A indicate that there are two important sources of back warming from far-ultraviolet absorption. Strong line blanketing by the rare earths redistributes flux longward of the Balmer discontinuity, causing the major observed photometric variations. In addition, a second source, which may be due to a combination of continuous opacities and line blanketing from the iron-peak and rare-earth groups below 1600 A, apparently redistributes flux into the region of the Balmer discontinuity. It is also found that ground-based determinations of the effective temperature are overestimated due to the flux redistribution from far-ultraviolet absorption. The effective temperature of alpha squared CVn derived from OAO and ground-based absolute fluxes is found to be 11,200 K, which remains constant over the cycle.

Molnar, M. R.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XXXIII - The symbiotic star AG Pegasi

Ultraviolet broadband photometry obtained with the Wisconsin Experiment Package on OAO 2 is presented for the symbiotic binary star AG Peg. The hot component of the binary is found to be a luminous ultraviolet source, with an energy distribution consistent with its WN6 optical spectral type. Total luminosities of 1000 and 17,000 suns are found for the hot star by assuming, respectively, that the giant primary of AG Peg is a normal M3 III star and that it fills its Roche lobe. The eruptive behavior of AG Peg is shown to require the higher luminosity, and the activity in AG Peg is discussed in terms of a very slow novalike nuclear-powered event.

Gallagher, J. S.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XIII - The albedos of Jupiter, Uranus, and Neptune

Presentation of OAO-2 broad-band ultraviolet photometry data for Jupiter, Uranus, and Neptune. These data have been combined with observations of 23 late-type stars to derive planetary albedos over the region 2000-4300 A. The new broad-band albedo for Jupiter agrees well with a previous measurement based on OAO-2 spectrometer data. The albedos for Uranus and Neptune are in good agreement with ground measurements in the region of overlap. The results for Uranus and Neptune have been compared with theoretical calculations for semiinfinite and finite pure H2 Rayleigh-Raman scattering atmospheres. Except for the shortest wavelengths, the measurements lie below the semiinfinite theoretical calculations. The calculations for the finite atmospheres suggest that an additional absorbing constituent will be needed to explain the observed albedos.

Savage, B. D.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XL - The energy distributions of spiral and irregular galaxies

Measurements of the total light of 40 spiral and irregular galaxies are presented. The photometry covers the wavelength range 1550-4250 A and is calibrated on an absolute basis. On the average later-type galaxies are not only bluer at short wavelengths than ellipticals but significantly bluer than visual colors would imply. This reflects a recent history of more vigorous formation of massive stars. The shape of the upper part of the initial mass function apparently varies more among early-type galaxies, producing a wide scatter in their energy distributions. In at least some galaxies interstellar dust appears to have little influence upon the emerging radiation. The local volume luminosity spectrum due to galaxies turns up steeply at short wavelengths, and is shaped largely by contributions from late-type galaxies. The observed ultraviolet background cannot be produced by normal galaxies, although the large corrections implied by theoretical evolutionary models may account for the measurements.

Code, A. D.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XXI - Absolute energy distribution of stars in the ultraviolet

The absolute energy distribution in the ultraviolet is given for the stars alpha Vir, eta UMa, and alpha Leo. The calibration is based on absolute heterochromatic photometry between 2920 and 1370 A carried out with an Aerobee sounding rocket. The fundamental radiation standard is the synchrotron radiation from 240-MeV electrons in a certain synchrotron storage ring. On the basis of the sounding-rocket calibration, the preliminary OAO-2 spectrometer calibration has been revised; the fluxes for the three program stars are tabulated in energy per second per square centimeter per unit wavelength interval.

Bless, R. C.↗

Ultraviolet photometry from the orbiting astronomical observatory. 8: The blue Ap stars

The filter photometers in the Wisconsin Experiment Package on OAO-2 were used to obtain data for a carefully selected set of 24 blue Ap stars and 31 comparison standard B and A dwarfs and giants for a program of relative photometry. Observations were made in seven bandpasses over the effective wavelength range 1430A-4250A. The Ap stars observed include members of the Si, Hg-Mn and Sr-Cr-Eu peculiarity classes. Most of them are too blue in B-V for their published MK spectral classes. The blue Ap stars are markedly deficient in emitted ultraviolet flux and are underluminous as compared to normal stars with the same UBV colors. The Hg-Mn stars appear less flux deficient in the ultraviolet for their UBV colors than do Si or Sr-cr-Eu stars. Most of the Ap stars observed possess ultraviolet flux distributions, or ultraviolet color temperatures, consistent with their published MK spectral classes to well within the classification uncertainties.

Leckrone, D. S.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XI - The 1971 eclipse of 32 Cygni

We observed the 1971 eclipse of 32 Cyg at regular intervals from November 1 to 15 with the wide-band filter photometers aboard OAO-2. Data have been reduced for seven filter bands with effective wavelengths between 4250 and 1430 A. Both the constancy of the light near mid-eclipse for the shorter wavelengths, and the derived energy distribution of the B component over all of these wavelengths indicate that the eclipse was total. The spectral types determined from the photometry of the two components are B5 and K4 Ib, after correction for interstellar reddening of 0.10 mag in B-V.

Doherty, L. R.↗