Search NASA⌕ Search

SEARCH · Search NASA

Results for “Abel Inversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An experimental investigation of gas fuel injection with X-ray radiography

In this paper, an outward-opening compressed natural gas, direct injection fuel injector has been studied with single-shot x-ray radiography. Three dimensional simulations have also been performed to compliment the x-ray data. Argon was used as a surrogate gas for experimental and safety reasons. This technique allows the acquisition of a quantitative mapping of the ensemble-average and standard deviation of the projected density throughout the injection event. Two dimensional, ensemble average and standard deviation data are presented to investigate the quasi-steady-state behavior of the jet. Upstream of the stagnation zone, minimal shot-to-shot variation is observed. Downstream of the stagnation zone, bulk mixing is observed as the jet transitions to a subsonic turbulent jet. From the time averaged data, individual slices at all downstream locations are extracted and an Abel inversion was performed to compute the radial density distribution, which was interpolated to create three dimensional visualizations. The Abel reconstructions reveal that upstream of the stagnation zone, the gas forms an annulus with high argon density and large density gradients. Inside this annulus, a recirculation region with low argon density exists. Downstream, the jet transitions to a fully turbulent jet with Gaussian argon density distributions. This experimental data is intended to serve as a quantitative benchmark for simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporally and spatially resolved X-ray densitometry in a shock tube

Gas densities were measured by x-ray absorption spectroscopy to examine spatial inhomogeneity in density behind incident and reflected shock waves in a miniature (12.7 mm bore) high repetition rate shock tube. Shock waves were generated in argon. The pressure and temperature behind the incident shock were P 2 ~ 1.72 bar and T 2 ~ 800 K, while those behind the reflected shock were P 5 ~ 6.5 bar and T 5 ~ 1480 K. Time-resolved line-of-sight transmission measurements using x-rays at 9 keV photon energy were made along various axial and transverse locations covering the entire shock tube cross section. The x-ray transmission at each location was converted to pathlength-integrated densities, which in some conditions could be further converted to pathlength-averaged densities. The measured gas densities were compared with those calculated by the normal shock wave relations, and good agreement was found in the preshock and immediately behind the incident shock regions. Similar agreement was found for reflected shock conditions very near the endwall. However, increasingly large differences between the measured and calculated gas densities were found as distance from the endwall increased. Furthermore, reconstruction by Abel inversion allowed time and radially resolved densities to be obtained from the transverse measurements. While the profiles measured in this experiment are of insufficient signal-to noise level and resolution to definitively assign boundary layer thicknesses, future improvements may be able to do this. The radially resolved densities reveal growing sidewall thermal boundary layers in gases behind the reflected shock. These reconstructions were compared with a model of the thermal boundary layer and are consistent with values of the thermal boundary layer thickness being between 0.25 mm and 1 mm at 0.7 ms after shock reflection.

42 ENGINEERING↗

Effect of Ducting on Radio Occultation Measurements: An Assessment Based on High-Resolution Radiosonde Soundings

Recent studies have shown that the presence of elevated ducts in the lower atmosphere has an adverse effect on the inversion of GPS radio occultation data. The problem arises because the microwave refractivity within and below an elevated duct is no longer uniquely determined by the bending angle profile. Applying Abel inversion without a priori knowledge of the duct will introduce a negative bias in the retrieved refractivity profile within and below the duct. In this work, high vertical resolution radiosonde data are used to give a quantitative assessment of the characteristics and effects of ducts, including their frequency of occurrences, heights, and thicknesses at different latitudes and seasons. The negative bias from the Abel-retrieved refractivity profiles resulting from these ducts is also computed. The results give a strong indication that ducting in the lower troposphere is a frequent phenomenon over the tropics and midlatitudes. The ducts are shown to be predominantly caused by sharp changes in the vertical structure of water vapor. The majority of the ducts are found to be below 2 km, with a median duct layer thickness of about 100 m. The negative refractivity bias is shown to be largest below 2 km, with a median value of about 0.5-1% in the tropics and 0.2-0.5% in midlatitudes. The bias is about a factor of 2-3 smaller between 2 to 3 km and is negligible above 4 km.

signals↗

Recovery of excitation intensity dependence in pulsed, focused beams - Nonsaturated case

It is shown how the dependence of a nonsaturated excitation process on local, instantaneous intensity can be obtained from temporally and spatially unresolved data by inversion, even for a nonuniform intensity distribution in the probe volume. This treatment is in contrast with the usual approach in which effects of nonuniform excitation are either disregarded or simulated. For exponential intensity profiles, the solution is obtained in the form of an Abel inversion. The ill-conditioned nature of the problem is demonstrated, and extension to the study of intensity-dependent line shapes is made.

Ruyten, Wilhelmus M.↗

Basis set expansion for inverse problems in plasma diagnostic analysis

A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)] is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20–25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial Molecular AlO Temperature Distributions in Laser-Induced Plasma

Spatially resolved, line-of-sight measurements of aluminum monoxide emission spectra in laser ablation plasma are used with Abel inversion techniques to extract radial plasma temperatures. Contour mapping of the radially deconvolved signal intensity shows a ring of AlO formation near the plasma boundary with the ambient atmosphere. Simulations of the molecular spectra were coupled with the line profile fitting routines. Temperature results are presented with simultaneous inferences from lateral, asymmetric radial, and symmetric radial AlO spectral intensity profiles. This analysis indicates that shockwave phenomena in the radial profiles, including a temperature drop behind the blast wave created during plasma initiation were measured.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Z{sub eff} profile measurement system with an optimized Czerny-Turner visible spectrometer in large helical device

Z{sub eff} measurement system using a visible spectrometer has been newly designed and constructed instead of an old interference filter system to eliminate line emissions from the signal and to measure the Z{sub eff} value in low-density plasmas. The system consists of the Czerny-Turner-type spectrometer with a charge-coupled device camera and 44 optical fibers vertical array. The spectrometer is equipped with an additional toroidal mirror for further reduction in the astigmatism in addition to a flat and two spherical mirrors and three gratings (110, 120, and 1200 grooves/mm) with 30 cm focal length. The images from 44 optical fibers can be detected without astigmatism in a wavelength range of 200-900 nm. Combination of the optical fiber (core diameter: 100 {mu}m) with the lens (focal length: 30 mm) provides spatial resolution of 30 mm at the plasma center. Results clearly indicate a very good focus image of the fiber and suggest the absence of the cross-talk between adjacent fiber images. Absolute intensity calibration has been done using a standard tungsten lamp to analyze the Z{sub eff} value. The bremsstrahlung profile and resultant Z{sub eff} profile have been obtained after Abel inversion of the signals observed in large helical device plasmas with elliptical poloidal cross section.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-line holography for the characterization of ultrafast laser filamentation in transparent media

A powerful experimental method, based on holographic microscopy, is used to retrieve the spatiotemporal distribution of small (<10{sup -3}) refractive index perturbations induced by ultrafast laser pulses in transparent media. A numerical iterative wavefront propagation approach is used to accurately reconstruct both the phase and the amplitude of the perturbed probe beam wavefront, while Abel inversion recovers the exact three dimensional distribution of the perturbation. For demonstration, a laser filament induced plasma string in air is fully characterized.

36 MATERIALS SCIENCE↗

Fast electron bremsstrahlung in axisymmetric magnetic configuration

The nonthermal bremsstrahlung is calculated in a plasma with arbitrary axisymmetric magnetic configuration, taking into account the relativistic angular anisotropy of the radiation cross section at high photon energies, the helical winding of the field lines on the magnetic flux surfaces, and the poloidal variation of the electron distribution function including particle trapping effects. The fast electron dynamics during current drive in tokamaks and reverse field pinches can be investigated in detail by coupling this calculation to a bounce-averaged relativistic Fokker-Planck solver, which calculates the electron distribution function. The asymmetry between high- and low-field side hard x-ray emission intensity that has been measured on the Tore-Supra tokamak [Equipe TORE SUPRA, in Proceedings of the 15th Conference on Plasma Physics and Controlled Nuclear Fusion Research, Seville (International Atomic Energy Agency, Vienna, 1995) Vol. 1, IAEA-CN-60/A1-5 (Institute of Physics, Bristol, U.K., 1995), p. 105] is explained for the first time by the role of trapped electrons. A much stronger poloidal asymmetry is predicted for the line-integrated fast electron bremsstrahlung in the poloidal plane of the Madison Symmetric Torus [R. N. Dexter et al., Fusion Tech. 19, 131 (1991)], since the helical winding of the magnetic field lines is much larger for a reverse field pinch configuration. In this case, the hard x-ray emission is no longer a flux surface quantity, which prevents local reconstructions using a standard Abel inversion, whatever the geometrical arrangement of the lines of sight.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical interferometric analysis of colliding laser produced air plasmas

Colliding air plasmas produced using 1064 nm Nd:YAG laser were analyzed using optical interferometry. For generating multiple air plasmas, the spherical aberrations of the focusing lens were used. The three-dimensional (3D) distributions of the electron density and the gas density behind shock wave front were investigated. The two-dimensional fast Fourier transform technique was used to extract the phase shift of the interferograms and a numerical inverse Abel transformation was applied to reconstruct the 3D distribution of the refractive index. Based on the Gladston-Dale relation, high resolution images of the 3D distributions of the electron density and the gas density were achieved. From the results, a stagnation layer was formed due to the collision of shock waves and the succeeding plasmas. The enhancements of electron density and gas density were observed in the collision zone. It shows that the collision region depends on the pulse energy. With smaller pulse energy, the thickness of the stagnation layer increased, while the enhancement of the gas density behind the shock wave front in the collision zone reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of the shielding cylinder and substrate on the characteristics of an argon radio-frequency atmospheric glow discharge plasma jet

With unique features of low breakdown voltages, large and uniform discharge areas and high concentrations of chemically reactive species, radio-frequency, atmospheric-pressure glow discharge (rf APGD) plasma sources produced with bare-metallic electrodes have shown promising prospects in the field of materials processing. In this paper, the spatial distributions (i.e., the directly measured integrated axial distribution and the radial distribution by using the inverse Abel transform) of the emission intensities of the Ar I 696.5 nm line are studied for the argon rf APGD plasma jet under different operation conditions, including variations of the rf power input or the argon flow rate, the existence of the solid shielding cylinder or the substrate. The experimental results show that, with other parameters being unchanged, the emission intensities of the Ar I 696.5 nm line increase with increasing the rf power input or the argon flow rate; and the solid shielding cylinder has more significant influences on the characteristics of the plasma impinging jet by reducing the mass flow rate of the ambient air entrained into the plasma jet region than those for the cases without the existence of the substrate at the downstream of the plasma torch nozzle exit.

36 MATERIALS SCIENCE↗

Convergent ablator performance measurements

The velocity and remaining ablator mass of an imploding capsule are critical metrics for assessing the progress toward ignition of an inertially confined fusion experiment. These and other convergent ablator performance parameters have been measured using a single streaked x-ray radiograph. Traditional Abel inversion of such a radiograph is ill-posed since backlighter intensity profiles and x-ray attenuation by the ablated plasma are unknown. To address this we have developed a regularization technique which allows the ablator density profile {rho}(r) and effective backlighter profile I{sub 0}(y) at each time step to be uniquely determined subject to the constraints that {rho}(r) is localized in radius space and I{sub 0}(y) is delocalized in object space. Moments of {rho}(r) then provide the time-resolved areal density, mass, and average radius (and thus velocity) of the remaining ablator material. These results are combined in the spherical rocket model to determine the ablation pressure and mass ablation rate during the implosion. The technique has been validated on simulated radiographs of implosions at the National Ignition Facility [Miller et al., Nucl. Fusion 44, 228 (2004)] and implemented on experiments at the OMEGA laser facility [Boehly et al., Opt. Commun. 133, 495 (1997)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density measurements using coherence imaging spectroscopy based on Stark broadening

A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the H{sub {gamma}} line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution 3D gas-jet characterization

We present a tomographic characterization of gas jets employed for high-intensity laser-plasma interaction experiments where the shape can be non-symmetrically. With a Mach-Zehnder interferometer we measured the phase shift for different directions through the neutral density distribution of the gas jet. From the recorded interferograms it is possible to retrieve 3-dimensional neutral density distributions by tomographic reconstruction based on the filtered back projections. We report on criteria for the smallest number of recorded interferograms as well as a comparison with the widely used phase retrieval based on an Abel inversion. As an example for the performance of our approach, we present the characterization of nozzles with rectangular openings or gas jets with shock waves. With our setup we obtained a spatial resolution of less than 60 {mu}m for an Argon density as low as 2 x 10{sup 17} cm{sup -3}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics for the free electron density of laser-generated plasma

This article reports on the development and set-up of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics of the free electron density in laser-generated plasma. The interferometer allows the recording of a series of 4 images within 6 ns of a single laser-plasma interaction. For the setup presented here, the minimal accessible free electron density is 5 x 10{sup 18} cm{sup -3}, the maximal one is 2 x 10{sup 20} cm{sup -3}. Furthermore, it provides a resolution of the electron density in space of 50 {mu}m and in time of 0.5 ns for one image with a customizable magnification in space for each of the 4 images. The electron density was evaluated from the interferograms using an Abel inversion algorithm. The functionality of the system was proven during first experiments and the experimental results are presented and discussed. A ray tracing procedure was realized to verify the interferometry pictures taken. In particular, the experimental results are compared to simulations and show excellent agreement, providing a conclusive picture of the evolution of the electron density distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of neutral density profiles using a deuterium Balmer-alpha diagnostic in the C-2 FRC plasma

In C-2 field-reversed configuration (FRC) device, low neutral density outside the FRC separatrix is required to minimize the charge exchange loss of fast particles. Titanium gettering is used in C-2 to reduce the wall recycling and keep the neutral density low in plasma edge. The measurements of neutral density radial profile are desirable to understand the plasma recycling and the effects of titanium gettering. These measurements are also needed to study the interaction of neutral beams with FRC plasma and confinement of fast ions. Diagnostic based on absolute deuterium Balmer-alpha (D-alpha) radiation measurements is developed and deployed on C-2 device to measure the radial profile of neutral density. Simultaneous measurements of electron density and temperature are done using CO{sub 2} interferometer, Thomson scattering, and triple probes diagnostics along with absolute D-alpha radiation. Abel inversion was performed to get the time dependent radial profile of the local D-alpha emission density. Neutral density profiles are obtained under different machine conditions of titanium deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗