Accelerating Cavities for a Relativistic-Klystron Two-Beam Accelerator. Final Technical Report
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Fermilab is planning to upgrade its accelerator complex to deliver a more powerful and intense proton-beam for neutrino experiments. In the framework of the so-called Proton Improvement Plan-II (PIP-II), we are designing and developing a cryomodule containing superconducting accelerating cavities, the Single Spoke Resonators of type 1 (SSR1). In this paper, we present the sequence of analysis and calculations performed for the structural de- sign of these cavities, using the rules of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC). The lack of an accepted procedure for addressing the design, fabrication, and inspection of such unique pressure vessels makes the task demanding and challenging every time. Several factors such as exotic materials, unqualified brazing procedures, limited nondestructive examination, and the general R&D nature of these early generations of cavity design, conspire to make it impractical to obtain full compliance with all ASME BPVC requirements. However, the presented approach allowed us to validate the design of these new generation of single spoke cavities with values of maximum allowable working pressure that exceed the safety requirements. This set of rules could be used as a starting point for the structural design and development of similar objects.
This project aimed to develop a prototype for a novel accelerator structure comprising coupled cavities that are tuned to support modes with harmonically-related eigenfrequencies, with the goal of reaching an acceleration gradient >200 MeV/m and a breakdown rate <10 -7 /pulse/meter. Phase I involved computations, design, and preliminary engineering of a prototype multi-harmonic cavity accelerator structure; plus tests of a bimodal cavity. A computational procedure was used to design an optimized profile for a bimodal cavity with high shunt impedance and low surface fields to maximize the reduction in temperature rise ΔT. This cavity supports the TM010 mode and its 2nd harmonic TM011 mode. Its fundamental frequency is at 12 GHz, to benchmark against the empirical criteria proposed within the worldwide High Gradient collaboration for X-band copper structures; namely, a surface electric field E sur max < 260 MV/m and pulsed surface heating ΔT max < 56 °K. With optimized geometry, amplitude and relative phase of the two modes, reductions are found in surface pulsed heating, modified Poynting vector, and total RF power—as compared with operation at the same acceleration gradient using only the fundamental mode.
Multilayer films on the interior of a superconducting radio frequency (SRF) accelerating cavity have the potential to increase the lower critical magnetic field Hc1 of the bulk cavity material [A. Gurevich, Appl. Phys. Lett. 88, 012511 (2006)]. A cavity with enhanced Hc1 can tolerate higher accelerating gradients, allowing for the construction of SRF par?ticle accelerators with lower capital costs, and more stable beams and cryogenic systems. Multilayer films are composed of alternating layers of insulator and superconductor, each of which layer is thinner than the London penetration depth of the superconductor. This dissertation presents an experimental program for the evaluation of multilayer thin films for SRF, as well as the first evaluation of such films in the RF regime. A stripline disk res?onator operating at 2.8 GHz supplies field to a small, flat multilayer sample, in which the superconducting film is (Nb,Ti)N and the insulating film is Al2O3. By measuring the Q of the resonator, Hc1 may be measured and compared with equivalent bulk superconducting samples
The objective of this research project is to produce single crystal niobium (Nb) tubes for use as particle accelerator cavities for the Fermi laboratory’s International Linear Collider project. Single crystal Nb tubes may have superior performance compared to a polycrystalline tube because the absence of grain boundaries may permit the use of higher accelerating voltages.
Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 {\mu}m accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 {\mu}m over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.
Presents the design of a fast-tuning system based on nickel-zinc ferrite for a 24.6 MHz accelerating cavity, developed to compensate for frequency shifts during transition crossing in a hadron storage ring. Covers ferrite material selection, tuner mechanical design, and expected RF performance.
ACE3P is a 3D massively parallel simulation suite that developed at SLAC National Accelerator Laboratory that can perform coupled electromagnetic, thermal and mechanical study. Effectively utilizing supercomputer resources, ACE3P has become a key simulation tool for particle accelerator R and D. A new frequency domain solver to perform mechanical harmonic response analysis of accelerator components is developed within the existing parallel framework. This solver is designed to determine the frequency response of the mechanical system to external harmonic excitations for time-efficient accurate analysis of the large-scale problems. Coupled with the ACE3P electromagnetic modules, this capability complements a set of multi-physics tools for a comprehensive study of microphonics in superconducting accelerating cavities in order to understand the RF response and feedback requirements for the operational reliability of a particle accelerator. (auth)
The objectives of this project are to 1, Expand the scientific and technological understanding of the effect of post-treatment (electropolish, buffered chemical polish, low-temperature baking) on the surface of niobium; 2, Relate the knowledge to the performance of niobium superconducting radiofrequency accelerator cavities; and, 3, Thereby design and demonstrate an electropolish process that can be applied to complete cavities.
In the Phase I program, Calabazas Creek Research, Inc. (CCR), in collaboration with North Carolina State University (NCSU), fabricated copper accelerator cavities and used Atomic Layer Deposition (ALD) to apply thin metal coatings of tungsten and platinum. It was hypothesized that a tungsten coating would provide a robust surface more resistant to arcing and arc damage. The platinum coating was predicted to reduce processing time by inhibiting oxides that form on copper surfaces soon after machining. Two sets of cavity parts were fabricated. One was coated with 35 nm of tungsten, and the other with approximately 10 nm of platinum. Only the platinum cavity parts could be high power tested during the Phase I program due to schedule and funding constraints. The platinum coated cavity exhibit poor performance when compared with pure copper cavities. Not only did arcing occur at lower power levels, but the processing time was actually longer. There were several issues that contributed to the poor performance. First, machining of the base copper cavity parts failed to achieve the quality and cleanliness standards specified to SLAC National Accelerator Center. Secondly, the ALD facilities were not configured to provide the high levels of cleanliness required. Finally, the nanometer coating applied was likely far too thin to provide the performance required. The coating was ablated or peeled from the surface in regions of high fields. It was concluded that the current ALD process could not provide improved performance over cavities produced at national laboratories using dedicated facilities.
Improved energy efficiency and reduced cost are greatly desired for advanced particle accelerators. Progress toward both can be made by atomically-smoothing the interior surface of the niobium superconducting radiofrequency accelerator cavities at the machine's heart. Laser polishing offers a green alternative to the present aggressive chemical processes. We found parameters suitable for polishing niobium in all surface states expected for cavity production. As a result, careful measurement of the resulting surface chemistry revealed a modest thinning of the surface oxide layer, but no contamination.
Topography arising from the final etch step in preparing niobium superconducting radiofrequency (SRF) accelerator cavities is understood to significantly impact cavity performance at high field levels. This study investigated the effect of process temperature and time on the etch rate and topography arising from the widely-used buffered chemical polishing (BCP). This study aims to understand more thoroughly the genesis of topography in BCP of polycrystalline niobium, with the ultimate aim of finding a path to surface smoothness comparable to that obtained by electro-polishing (EP). It was found that the etch process is controlled by the surface reaction; and that the etch rate varies with crystallographic orientation. The familiar micron-scale roughening necessarily results. Gas evolution has an impact, but is secondary. The major outcome is that surface smoothness comparable to EP appears to be inherently unachievable for polycrystalline niobium using BCP, setting an upper limit to the gradient for which it is useful.
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 \mu m was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.
This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024
Here, we report the results of surface characterizations of niobium (Nb) samples electropolished together with a single cell superconducting radio-frequency accelerator cavity. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive X-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.
Current designs for muon accelerators require high-gradient radio frequency (RF) cavities to be placed in solenoidal magnetic fields. These fields help contain and efficiently reduce the phase space volume of source muons in order to create a usable muon beam for collider and neutrino experiments. In this context and in general, the use of RF cavities in strong magnetic fields has its challenges. It has been found that placing normal conducting RF cavities in strong magnetic fields reduces the threshold at which RF cavity breakdown occurs. To aid the effort to study RF cavity breakdown in magnetic fields, it would be helpful to have a diagnostic tool which can localize the source of breakdown sparks inside the cavity. These sparks generate thermal shocks to small regions of the inner cavity wall that can be detected and localized using microphones attached to the outer cavity surface. Details on RF cavity sound sources as well as the hardware, software, and algorithms used to localize the source of sound emitted from breakdown thermal shocks are presented. In addition, results from simulations and experiments on three RF cavities, namely the Aluminum Mock Cavity, the High-Pressure Cavity, and the Modular Cavity, are also given. These results demonstrate the validity and effectiveness of the described technique for acoustic localization of breakdown.
A 218 MHz quarter wave niobium cavity has been fabricated for the purpose of demonstrating Nb3Sn technology on a low-beta accelerator cavity. Niobiumtin has been established as a promising next generation SRF material, but development has focused primarily in high-beta elliptical cell cavities. This material has a significantly higher TC than niobium, allowing for design of higher frequency quarter wave cavities (that are subsequently smaller) as well as for significantly lowered cooling requirements (possibly leading to cryocooler based designs). The fabrication, initial cold testing, and Nb3Sn coating are discussed as well as test plans and details of future applications.
We investigate the feasibility of beam position diagnostics using higher order mode (HOM) signals excited by an electron beam in the third harmonic 3.9 GHz superconducting accelerating cavities at FLASH. After careful theoretical and experimental assessment of the HOM spectrum, three modal choices have been narrowed down to fulfill different diagnostics requirements. These are localized dipole beam-pipe modes, trapped cavity modes from the fifth dipole band, and propagating modes from the first two dipole bands. These modes are treated with various data analysis techniques: modal identification, direct linear regression (DLR), and singular value decomposition (SVD). Promising options for beam diagnostics are found from all three modal choices. This constitutes the first prediction, subsequently confirmed by experiments, of trapped HOMs in third harmonic cavities, and also the first direct comparison of DLR and SVD in the analysis of HOM-based beam diagnostics.