Window Test Stand Status and Future Work [Slides]
Challenges to getting the window test stand running that were addressed. Initial design of half-anchor connector was insufficient. Accommodation of non-Rexolite windows required engineering.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Challenges to getting the window test stand running that were addressed. Initial design of half-anchor connector was insufficient. Accommodation of non-Rexolite windows required engineering.
The goal for this work is to determine the parameters that are needed for tuning the beam, and devise a structure sufficient for accessing, reading, and writing those parameters.
Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.
LANL is providing support to Niowave Inc. on the design and analysis of a 200 kW converter. The current design of the 200 kW (40 MeV, 5 mA electron beam) converter consists of LBE flowing from the top to the bottom. When compared to the Mk.5 20 kW converter, which flowed LBE from the bottom, flowing over a divider plate to create a waterfall, the 200 kW converter eliminates the divider plate, which would otherwise have melted with the higher beam power. Because the LBE flows from the top to the bottom, alternate methods to the divider plate need to be utilized to ensure a stable flow that minimizes splashing at the bottom of the LBE waterfall, while maintaining a uniform LBE thickness at the beam, and steady LBE flow at the desired flow rate.
Evidenced from experiments to date, NorthStar can expect that potentially significant changes in the target cooling passages are likely due to disk shape changes by thermal distortions or breakage. In the bulk of the target the result will be increased He flow in some channels and decreased flow in others.
This report provides information about accelerators, from the different types to ways they are used in everyday life.
It is critical to maintain proper flow rate of lead bismuth eutectic (LBE) for the operation of the Niowave converter. The high temperature of the LBE (> 200 °C) makes it difficult to purchase simple off the shelf flow meters. One method that can be used to measure the flow rate indirectly, is to use a venturi, with a known throat diameter and differential pressure measurement across the throat. LANL designed the venturi and after numerous iterations with vendors, narrowed down a differential pressure transducer to use with the venturi.
This report is a continuation of the work performed in the report, Mo-100 Disk Structural Integrity Tests I [1]. The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in-beam during production. These large temperature gradients cause high stress and deformation within the disks that could prove detrimental to the target assembly’s cooling performance. Disk fracture is also a possibility that must be understood. Therefore, disk structural integrity tests were performed to understand the thermal induced behavior of these disks. In order to replicate the in-beam conditions, the Mo-100 disks were subjected to large temperature gradients using a 30kW induction heater and coil. A series of transient tests were conducted in a similar fashion as the previous work, as well as an attempt to create steady state conditions for more accurate temperature gradients. The transient thermal test setup and results are described in this report.
Achieving high-gradient performance (low breakdown rates, low field emission, new materials for HOM absorption, cathodes at high gradient etc.) is a materials science problem. Los Alamos is, at core, a materials science laboratory with particular expertise in metallurgy. Los Alamos also considers itself the steward of accelerator science for the NNSA part of the DOE complex. Thus, Los Alamos has both an institutional interest in, and capability to address, this problem space. High gradient C-band work directly aligns with future NNSA and LANL missions.
The purpose of this document is to present the evaluation summary of the initial cost proposal of the mechanical beamline components and associated labor for the LANSCE Modernization Project (LAMP).
A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.
The LANSCE Modernization Project (LAMP) concept includes a drift-tube proton linac (DTL) from 3 MeV to 100 MeV consisting of 6 tanks. This technical note provides estimates of RF power required for the LAMP DTL tanks using DTLfish modeling.
Particle accelerators are among the most versatile and important tools of scientific discovery. The Nation's accelerators are responsible for a wealth of advances in materials science, chemistry, the biosciences, particle physics, and nuclear physics. They also have important applications to national security, the environment, energy, medicine, and on the quality of people's lives. LANL has a long history of making pioneering contributions to Accelerator Science including key contributions to the field of Computational Accelerator Physics. These include the development of early beam dynamics codes with space charge (such as PARMILA and PARMELA), the development of rf cavity codes and magnet codes (including Poisson and Superfish), and the development and distribution of codes to the accelerator community through the Los Alamos Accelerator Code Group. LANL researchers also helped pioneer the development of massively parallel space-charge codes. In project t22_accelsim we have moved beyond electrostatic models of collective effects (i.e., solving the Poisson equation in the bunch frame) to fully electromagnetic models based on the Lienard-Wiechert formalism. This approach enables the large-scale simulation of radiation production and collective effects in high brightness electron beams. This is highly relevant to LANL given its future goal of developing an X-ray Free Electron Laser (XFEL). It also directly impacts a LANL LDRD project to develop an undulator-based non-invasive beam profile monitor for beams created in laser-plasma accelerator systems.
This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). Many factors contribute to the performance limits of the CCL accelerator system. One performance limit is set by the CCL mechanical structure and available cooling. Heating of the structure is ultimately linked to the operating RF duty factor of the CCL. Another performance limit is set by the maximum RF and beam duty factors that can be supported by the 805-MHz klystrons and associated HVDC power supplies. The RF and HVDC systems also set limits for the maximum peak beam current that can be accelerated in the CCL. And finally, a maximum beam current limit is set by the beam dynamics determined by the details of the CCL physics design (number of cells per CCL tank, accelerating gradients, magnetic focusing lattice, beam losses, etc.). This limit can be informed by both simulation results and beam measurement data, if available. A detailed explanation of each performance limit is given in the sections below. The results are summarized in the table below. In all cases, it is assumed that the CCL and the RF system are operating in their nominal beam production configuration – nominal magnet set points and nominal cavity fields, unless otherwise specified.
Abstract not provided.
Using the code Parmteq and a model of the 750 keV test stand RFQ produced by Kress, labeled ‘as11c’, I calculate the effect on RFQ beam transmission in the following cases: 1. Varying input energy spread, 2. Transverse mismatch of the input beam, 3. Varying input emittance of matched beam, and 4. Injection offset of beam centroid. For this model, the RFQ transmission is 96.3%, input energy 35 keV, and beam current 35 mA.