Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accuracy and stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Accuracy and stability of finite element schemes for the duct transmission problem

An investigation is conducted regarding the feasibility of approaches for improving the efficiency and stability of existing finite element method (FEM) schemes, taking into account both analytical and numerical studies. Of the four schemes considered for the 'steady' problem, the Hermitian Galerkin formulation appears to be the most efficient and therefore the most suitable scheme for futher full scale implementation. The Hermitian residual least squares (RLS) scheme although comparable in accuracy for the cases considered exhibits a slight tendency to cumulative errors. The performance of both the Lagrangian element schemes considered compares poorly with that of their Hermitian element counterparts. This is particularly true of the Lagrangian RLS scheme. The presence of internal oscillatory components is an inevitable consequence of all Galerkin schemes irrespective of element type.

Astley, R. J.↗

NASA hydrogen maser accuracy and stability in relation to world standards

Frequency comparisons were made among five NASA hydrogen masers in 1969 and again in 1972 to a precision of one part in 10 to the 13th power. Frequency comparisons were also made between these masers and the cesium-beam ensembles of several international standards laboratories. The hydrogen maser frequency stabilities as related to IAT were comparable to the frequency stabilities of individual time scales with respect to IAT. The relative frequency variations among the NASA masers, measured after the three-year interval, were 2 + or - 2 parts in 10 to the 13th power. Thus time scales based on hydrogen masers would have excellent long-term stability and uniformity.

Peters, H. E.↗

Explicit numerical formulas of improved stability and accuracy for the solution of parabolic equations

A class of explicit numerical formulas which involve next nearest neighbor as well as nearest neighbor points are explored in this paper. These formulas are formal approximations to the linear parabolic partial-differential equation of first order in time and second order in distance. It was found that some of these formulas can employ time steps as much as four times that for the conventional explicit technique without becoming unstable. Others showed improved accuracy for a given time step and spatial grid spacing. One formula achieved a steady-state solution of specified accuracy for an example problem in less than 4 percent of the total computational time required by the conventional explicit technique.

Olstad, W. B.↗

Accuracy and stability of time-split finite-difference schemes

In a recently published work by Abarbanel and Gottlieb (1980), a new class of explicit time-split algorithms designed for application to the compressible Navier-Stokes equations was developed. These algorithms, which utilize locally-one-dimensional (LOD) spatial steps, were shown to possess stability characteristics superior to those of other time-split schemes. In the present work, the properties of an implicit LOD method, analogous to the Abarbanel-Gottlieb algorithm, are examined using the two-dimensional heat conduction equation as the test problem. Both temporal and spatial inconsistencies inherent in the scheme are identified, and a new consistent, implicit splitting approach is developed and applied to the linear Burgers' equation. The relationship between this new method and other time-split implicit schemes is explained and stability problems encountered with the method in three dimensions are discussed.

Dwoyer, D. L.↗

Cryogenic Behavior of the High Temperature Crystal Oscillator PX-570

Microprocessors, data-acquisition systems, and electronic controllers usually require timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that utilize crystal oscillators due to availability, cost, ease of operation, and accuracy. Stability of these oscillators, i.e. crystal characteristics, is usually governed, amongst other things, by the ambient temperature. Operation of these devices under extreme temperatures requires, therefore, the implementation of some temperature-compensation mechanism either through the manufacturing process of the oscillator part or in the design of the circuit to maintain stability as well as accuracy. NASA future missions into deep space and planetary exploration necessitate operation of electronic instruments and systems in environments where extreme temperatures along with wide-range thermal swings are countered. Most of the commercial devices are very limited in terms of their specified operational temperature while very few custom-made and military-grade parts have the ability to operate in a slightly wider range of temperature. Thus, it is becomes mandatory to design and develop circuits that are capable of operation efficiently and reliably under the space harsh conditions. This report presents the results obtained on the evaluation of a new (COTS) commercial-off-the-shelf crystal oscillator under extreme temperatures. The device selected for evaluation comprised of a 10 MHz, PX-570-series crystal oscillator. This type of device was recently introduced by Vectron International and is designed as high temperature oscillator [1]. These parts are fabricated using proprietary manufacturing processes designed specifically for high temperature and harsh environment applications [1]. The oscillators have a wide continuous operating temperature range; making them ideal for use in military and aerospace industry, industrial process control, geophysical fields, avionics, and engine control. They exhibit low jitter and phase noise, consume little power, and are suited for high shock and vibration applications. The unique package design of these crystal oscillators offers a small ceramic package footprint, as well as providing both through-hole mounting and surface mount options.

Patterson, Richard↗

Future Laser-Cooled Microwave Clock Performance

Limitations to the performance of laser-cooled earth and space-based Cs clocks will be critically discussed. The most significant limitation to the stability and accuracy of laser-cooled atomic clocks is the frequency shift due to cold collisions. Because of it, laser-cooled Cs clocks must be operated at low density and this implies that space based Cs clock performance will not be significantly better than earth based. To regain some of the high accuracy and stability lost to the low density, clocks can be designed to multiply launch (or juggle) atoms. Clocks based on other atoms, in particular Rb-87 or possibly Rb-85, may have much smaller cold collision frequency shifts and therefore be capable of higher stability and accuracy, especially in a space environment.

Gibble, Kurt↗

Convection equation modeling: A non-iterative direct matrix solution algorithm for use with SINDA

The determination of the boundary conditions for a component-level analysis, applying discrete finite element and finite difference modeling techniques often requires an analysis of complex coupled phenomenon that cannot be described algebraically. For example, an analysis of the temperature field of a coldplate surface with an integral fluid loop requires a solution to the parabolic heat equation and also requires the boundary conditions that describe the local fluid temperature. However, the local fluid temperature is described by a convection equation that can only be solved with the knowledge of the locally-coupled coldplate temperatures. Generally speaking, it is not computationally efficient, and sometimes, not even possible to perform a direct, coupled phenomenon analysis of the component-level and boundary condition models within a single analysis code. An alternative is to perform a disjoint analysis, but transmit the necessary information between models during the simulation to provide an indirect coupling. For this approach to be effective, the component-level model retains full detail while the boundary condition model is simplified to provide a fast, first-order prediction of the phenomenon in question. Specifically for the present study, the coldplate structure is analyzed with a discrete, numerical model (SINDA) while the fluid loop convection equation is analyzed with a discrete, analytical model (direct matrix solution). This indirect coupling allows a satisfactory prediction of the boundary condition, while not subjugating the overall computational efficiency of the component-level analysis. In the present study a discussion of the complete analysis of the derivation and direct matrix solution algorithm of the convection equation is presented. Discretization is analyzed and discussed to extend of solution accuracy, stability and computation speed. Case studies considering a pulsed and harmonic inlet disturbance to the fluid loop are analyzed to assist in the discussion of numerical dissipation and accuracy. In addition, the issues of code melding or integration with standard class solvers such as SINDA are discussed to advise the user of the potential problems to be encountered.

Schrage, Dean S.↗

Sextant Navigation on the International Space Station: A Human Space Exploration Demo

Astronauts on board the International Space Station (ISS) tested a hand-held sextant to demonstrate potential use on future human exploration missions such as Orion and Gateway. The investigation, designed to aid in the development of emergency navigation methods for future crewed spacecraft, took place from June-December 2018. A sextant provides manual capability to perform star/planet-limb sightings and estimate vehicle state during loss of communication or other contingencies. Its simplicity and independence from primary systems make it useful as an emergency survival backup or confirming measurement source. The concept of using a sextant has heritage in Gemini, Apollo, and Skylab. This paper discusses the instrument selection, flight certification, crew training, product development, experiment execution, and data analysis. Preflight training consisted of a hands-on session with the instrument and practice in a Cupola mock-up with star field projector dome. The experiment itself consisted of several sessions with sextant sightings in the ISS Cupola module by two crew members. Sightings were taken on star pairs, star/moon limb, and moon diameter. The sessions were designed to demonstrate star identification and acquisition, sighting stability, accuracy, and lunar sights. Results are presented which demonstrate sightings within the accuracy goal of 60 arcseconds, even in the presence of window refraction effects and minimal crew training. The crew members provided valuable feedback on sighting products and microgravity stability techniques.

Exploration↗

Refinement of the ICRF

Since the ICRF was generated in 1995, VLBI modeling and estimation, data quality: source position stability analysis, and supporting observational programs have improved markedly. There are developing and potential applications in the areas of space navigation Earth orientation monitoring and optical astrometry from space that would benefit from a refined ICRF with enhanced accuracy, stability and spatial distribution. The convergence of analysis, focused observations, and astrometric needs should drive the production of a new realization in the next few years.

Ma, Chopo↗

Application of Atmospheric Infrared Sounder (AIRS) Data to Climate Research

The application of hyper spectral radiometric data to climate research requires very high absolute radiometric accuracy and stability. We use cloud-free tropical ocean data from the Atmospheric InfraRed Sounder (AIR) Calibration Data Subset (ADCS) to show that the radiometric precision and stability required climate applications has been achieved. The sea surface skin temperatures derived from the AIRS 2616cm-1 super window channel are stable relative to the RTG.SST at the better than 8 mK/year level, and the spectral calibration is stable at the 1 ppm/year level. The excellent stability and accuracy are the result of the implementation of AIRS as a grating array spectrometer, which is cooled and stabilized within 10 mK at 155 K. Analysis of daily measurements of the temperature gradient between the surface and 7 km altitude show that the AIRS Calibration Data Subset has applications which extend its original intent for calibration support to climate research. The Atmospheric Infrared Sounder (AIRS) on the EOS Aqua satellite was launched into polar orbit in May 2002. AIRS covers the spectral region from 640 to 2700 cm-1 with 2378 independent channels and represents the first of a new generation of hyper spectral resolution sounders in support of global sounding data for weather forecasting and climate research.

infrared↗