Search NASA⌕ Search

SEARCH · Search NASA

Results for “Activation Foils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Expanding Benchmarks for Nuclear Data Validation [Slides]

The presentation discusses benchmarking in comparison to experimental truth, the integral experiments that were performed, and that benchmarks are evaluated experiments. It also discusses validation testing, and that the ultimate goal of the validation end product is to improve evaluated nuclear data for applications It does state that validation highlights errors in the Nuclear Data Pipeline that affect applications, for example: Missing Cd Capture Gammas in ENDF/B-VII.1. It acknowledges that additional types of experiments are needed to test data used in applications, and that validation experiments do not have to be complicated and expensive. The presentation also discusses different types of measurements including activation foil and fission chamber measurements, reactor kinetics measurements, and subcritical measurements. The presentation concludes with an experiment summary and states that all applications need validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Shielding Benchmark Overview [Slides]

This presentation shows that Integral experiments increase the level of realism from that of data measurements. Further, Godiva IV is capable of intensities to activate foils. IER 498 uses a relative measurement to provide an intermediate level of realism. With reproducibility and room return management are key components. The test matrix put forward in CED-2 enables numerous cross-comparisons. IER 498 facilitates various additional works using a room return shield to isolate the source. IER 557 demonstrated burst reproducibility sufficient for IER 498.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron production and dosimetry with D(D,n) 3 He, 12 C(D,n) 13 N and 7 Li(p,n) 7 Be reactions at the Sandia Ion Beam Laboratory

Neutrons are produced at the Sandia Ion Beam Laboratory (IBL) using a beam of 280 keV D 2 + ions onto an erbium deuteride target. At test locations in the forward direction these neutrons have energies of about 2.9 MeV and a maximum flux on the flange of the test chamber of about 10 10 n/cm 2 /hour. Dosimetry is done by counting associated charged particles and by nickel foil activation dosimetry. Neutrons with higher energies, up to 6 MeV are produced using higher energy deuterium, up to 3 MeV, from the Pelletron ion accelerator at the IBL on a deuteride target. This report provides detailed information on the methods used for the production and dosimetry of neutrons by the D(D,n) 3 He nuclear reaction at the IBL. Neutron production by the 7 Li(p,n) 7 Be reaction with a proton beam from the Pelletron on a lithium target, such as LiF is also discussed. This produces neutrons with lower energy, in the range from about 0.1 to 1.3 MeV. Neutron production by the 12 C(D,n) 13 N reaction is also discussed. The purpose of this report is to provide information needed to test the effects of neutron irradiation on semiconductor materials and devices at the Sandia IBL.

36 MATERIALS SCIENCE↗

Preliminary Activation Wire Analysis for the POKER Experiment Flattop Irradiation

Activation foils, or in this case wires, are commonly deployed to critical experiments at the Na tional Criticality Experiments Research Center (NCERC) to provide additional neutron diagnostics and provide additional energy-dependent responses to tie back to neutronic and/or multi-physics simulations.

07 ISOTOPE AND RADIATION SOURCES↗

First experimental determination of the ⁴⁰Ar(𝑛, 2𝑛)³⁹Ar reaction cross section and ³⁹Ar production in Earth’s atmosphere

The cosmogenic ³⁹Ar(t1∕2 = 268 years) isotope of argon is used for geophysical dating and tracing of underground and ocean water, as well as ice owing to its appropriate half-life and chemical inertness as a noble gas; ³⁹Ar serves also in nuclear weapon test monitoring. We measured for the first time the total cross section of the main ³⁹Ar cosmogenic production reaction in the atmosphere, namely ⁴⁰Ar(𝑛, 2𝑛)39 Ar, using 14.8 ± 0.3 MeV neutrons. The neutrons, produced by a deuterium-tritium generator, impinged on a stainless steel sphere filled with Ar gas highly enriched in the ⁴⁰Ar isotope and were monitored by a stack of fast-neutron activation foils. The reaction yield was measured by atom counting of long-lived ³⁹Ar with noble gas accelerator mass spectrometry and, independently, by decay counting relative to atmospheric argon (³⁹Ar/Ar= 8.12 × 10−16 ). A total ⁴⁰Ar(𝑛, 2𝑛)39 Ar cross section of 610 ± 100 mb was determined at 14.8 ± 0.3 MeV incident neutron energy. This result serves as a benchmark for recent theoretical calculations and evaluations, found to reproduce well the experimental total cross section. We use these energy-dependent theoretical cross sections together with experimental spectra of cosmogenic neutrons at different altitudes to calculate the global average rate of neutron-induced ³⁹Ar atmospheric production, resulting in 770 ± 240 39 Ar atoms/cm²/day. The secular equilibrium between the ³⁹Ar calculated production rate and radioactive decay rate leads to a partial isotopic abundance ³⁹Ar/Ar = (5.9 ± 1.8) × 10−16 , showing that ≈73% of atmospheric ³⁹Ar is produced by cosmogenic neutrons, the remaining part believed to be induced by muons and high-energy 𝛾 rays. The ⁴⁰Ar(𝑛, 2𝑛)³⁹Ar cross section at 14 MeV is also a key parameter for quantifying the anthropogenic contribution to atmospheric 39 Ar produced during the thermonuclear tests of the 1960s. We estimate that anthropogenic ³⁹Ar accounts for roughly 20% of the present atmospheric inventory.

39 Ar atmospheric production↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the Fast-Neutron Irradiator and the Fast-Flux Tube Irradiation Fixtures at the Pennsylvania State Breazeale Reactor

Accurate knowledge of the neutron spectrum at a nuclear research reactor is a prerequisite for planning irradiation experiments, as well as for evaluating irradiation exposure results. The neutron-flux spectrum in the fast-neutron irradiator (FNI) and the fast-flux tube (FFT) irradiation fixtures at the Pennsylvania State Breazeale Reactor (PSBR) were characterized using the multi-foil neutron activation method. These irradiation fixtures make use of graded shielding to produce unique neutron fields. Multiple foil sets were irradiated in the fixtures with different exposure times and reactor powers to understand the stability over a wide range of operating conditions. Measured results were evaluated against a MCNP6 simulation to produce a measurement-informed neutron flux-energy spectrum for each fixture using STAYSL_PNNL. Simulated estimates of the FNI fixture, a newer fixture (~25 years old), demonstrated excellent agreement with measured results; the FFT did not. Thermal neutron measurements from the FFT suggest there is additional thermal leakage not captured in the simulation model. In conclusion, possible explanations for the discrepancy include burn-out or degradation (i.e., micro-cracking, gaps, etc.) in the boral and cadmium liners over the lifetime of the fixture (~40 years old).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Excitation function of 54 Fe(p, α ) 51 Mn from 9.5 MeV to 18 MeV

Excitation function of the 54 Fe(p,α) 51 Mn reaction was measured from 9.5 to 18 MeV $E_{0,p^+}$ by activating a foil stack of 54 Fe electrodeposited on copper substrates. Residual radionuclides were quantified by HPGe gamma ray spectrometry. Both 51 Mn ($t_{1/2}$ = 46.2 min, $\langle E_{β^+}\rangle$=963.7keV, $I_{β^+}$ = 97%; $E_γ$ = 749.1keV, $I_γ$ = 0.265%) and its radioactive daughter, 51 Cr ($t_{1/2}$ = 27.704d, $E_γ$ = 320.1 keV, $I_γ$ = 9.91%), were used to indirectly quantify formation of 51 Mn. Results agree within uncertainty to the only other measurement in literature and predictions of default TALYS theoretical code. Final relative uncertainties are within ±12%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental observation and integrated modelling of proton-beryllium fusion in He and D plasmas at JET

Validated integrated modelling of JET ITER-like wall experiments in which fusion performance is driven by reactions between fast ions and intrinsically present metal wall impurities is presented. A steady-state L-mode plasma with dominant proton-beryllium fusion and neutron yields of up to ≈ 6·10 13 s -1 is developed in He and D, via radiofrequency heating of a H minority. The fusion drive is unambiguously confirmed by the neutral particle analyser, fast ion loss detector, and γ-ray diagnostics. Experiments are analysed via an integrated modelling framework, developed to model the two-stage proton beryllium-fusion chain and produce high-fidelity fusion product source terms. The modelling chain comprises TRANSP and JETTO for plasma core modelling, LOCUST for full orbit product tracking and collisional slowing-down, DRESS to resolve two- and three-body fusion kinematics, and MCNP for neutron transport calculations. Modelling shows that the primary 9 Be(p,n) 9 B reaction is the dominant neutron emitter at naturally present concentrations of beryllium in these experiments. The yield contribution of secondary reactions between fusion products and beryllium, 9 Be(d,n) 10 B and 9 Be(α,n) 12 C, is found to be negligible. The proton-deuteron knock-on effect in D plasmas is modelled, which is calculated to contribute ≈ 25% to the total neutron yield. For both He and D discharges the total computed neutron rates match fission chamber (FC) measurements within the combined experimental and computational uncertainty, with an average discrepancy of ≈ ± 20%. Realistic proton-beryllium neutron sources are propagated through JET’s MCNP neutron transport model which shows that 235 U FCs’ response is sensitive to p–Be source changes, with up to ≈ 10% variation compared to a D–D neutron source. We show that the high-energy tail of the fast proton minority can be studied with multi-foil neutron activation. The framework is also applied to the study of interactions between fast protons and boron impurities, of relevance to ITER. We calculate that in JET conditions a significant alpha source with DT-like energies could be generated through 11 B(p, α)2α fusion, and detected via γ-emission in secondary interactions between fast alphas and boron. The work represents an important step towards validating predictive integrated modelling capabilities for non-standard fusion reactions.

JET↗

SCALE 6.2.4 Validation: Radiation Shielding

For safe and reliable use of computer codes by the community, accuracy must be clearly evaluated. In particular, the nuclear reactor engineering and licensing field needs accurate tools for radiation shielding modeling. Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) is one such tool, with built-in variance reduction methods distributed within the SCALE code, and its validity is demonstrated in this report for the released version 6.2.4. Representative benchmarks corresponding to shielding analysis are selected for the validation study. Typical experimental results analyzed from those benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma doses, foil neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between experiment and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, MAVRIC agrees well with the experiment results. MAVRIC is also compared to Monte Carlo N-Particle (MCNP) calculations when available, and both codes generally produce good agreements within estimated uncertainties. The selected benchmarks are obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP Handbook), the Shielding Integral Benchmark Archive & Database (SINBAD), and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to incrementally expand the shielding validation suite incrementally.

61 RADIATION PROTECTION AND DOSIMETRY↗

FLUKA simulation validation to measure the beam energy of a cyclotron

FLUKA is a fully integrated particle physics MonteCarlo simulation package which has many applications in high energy experimental physics and engineering. When using a cyclotron for medical radionuclide production, it is important to know that the beam energy is suitable to cause the intended nuclear reaction and minimize unwanted impurities. Here, this work focuses on the comparison of FLUKA as a tool to measure the beam energy of a cyclotron with experimental results using the method of stacked copper foils interspaced by an aluminum degrader. We compared two methods to determine the activity ratio: determining the activity in each foil using the experimentally measured cross-sections from the National Nuclear Data Center (NNDC) cross-section data and calculating the activity in the two Cu foils using the FLUKA program. These results were compared to those reported by Gagnon et al., 2011. The FLUKA results gave energy measurements that were different than the true energy by a percentage in the range of 2.4% to 13%, suggesting that FLUKA is not recommended for pre-calculating the cyclotron beam energy using these low Z materials without experimental confirmation. It also confirms that the experimental cross-section data from the NNDC database is superior for this application giving energy values that ranged from 0.1% to 1.6% from the true energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low profile pressure disconnect device for lithium ion batteries

Casings for lithium ion batteries are provided that include a container or assembly that defines a base, side walls and a top or lid, and a vent structure associated with the container or assembly. A flame arrestor may be positioned in proximity to the vent structure. The lithium ion battery may also include a pressure disconnect device associated with the casing. The pressure disconnect device may include a deflectable dome-based activation mechanism, and the deflectable dome-based activation mechanism may be configured and dimensioned to prevent burn through, e.g., by increasing the mass of the dome-based activation mechanism, adding material (e.g., foil) to the dome-based activation mechanism, and combinations thereof. Burn through may also be avoided, at least in part, based on the speed at which the dome-based activation mechanism responds at a target trigger pressure.

25 ENERGY STORAGE↗

A Data-driven approach to Core Power distribution reconstruction in a Nuclear Reactor

This report presents the initial development of a data-driven approach for reconstructing the core power distribution in a nuclear reactor (power shape synthesis) using ex-core sensors. Traditional techniques rely on deploying a large number of detectors throughout the reactor core. However, this approach is not feasible for innovative reactor concepts like Advanced Reactors and Microreactors. First, the tight lattice pitch, designed to maximize power density, limits the space available for sensors. Secondly, the harsh operating conditions are not compatible with commercially available detectors. The method proposed in this work integrates high-fidelity modeling with data-driven techniques to accurately reconstruct power distribution across various reactor types, thereby reducing the reliance on in-core sensors. Purdue University Reactor One (PUR-1) was selected as the test case. The CAD model representing the latest configuration of the PUR-1 core was imported into the OpenMC simulation framework, and the model was built. Additionally, the previously developed MCNP6 model was updated. The two models were assessed against the data collected during an experimental campaign conducted in July 2024. Thirty gold foils were placed in three Irradiation Assemblies in PUR-1 core. Using the measured activity of the irradiated foils, the neutron flux at different core locations was estimated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An In-Depth Analysis of the Transformation of Tin Foil Anodes during Electrochemical Cycling in Lithium-Ion Batteries

Tin foils have an impressive lithium-storage capacity more than triple that of graphite anodes, and their adoption could facilitate a drastic improvement in battery energy density. However, implementation of a dense foil electrode architecture represents a significant departure from the standard blade-cast geometry with a distinct electrochemical environment, and this has led to confusion with regards to the first cycle efficiency of the system. In this work, we investigate the unique behavior of a tin active material in a foil architecture to understand its performance as an anode. We find shallow cycling of the foil results in an irreversible formation (< 40%) due to diffusional trapping, but intermediate and complete utilization allows for a remarkably reversible formation reaction (> 90%). This striking nonlinearity stems from an in situ transformation from bulk metal to porous electrode that occurs during formation cycles and defines electrode-level lithium-transport on subsequent cycles. As a result, an alternative cycling procedure for assessing the stability of foils is proposed to account for this chemomechanical effect.

25 ENERGY STORAGE↗