Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adaptation, Physiological/physiology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Plants in space

Virtually all scenarios for the long-term habitation of spacecraft and other extraterrestrial structures involve plants as important parts of the contained environment that would support humans. Recent experiments have identified several effects of spaceflight on plants that will need to be more fully understood before plant-based life support can become a reality. The International Space Station (ISS) is the focus for the newest phase of space-based research, which should solve some of the mysteries of how spaceflight affects plant growth. Research carried out on the ISS and in the proposed terrestrial facility for Advanced Life Support testing will bring the requirements for establishing extraterrestrial plant-based life support systems into clearer focus.

Non-NASA Center↗

Neural readaptation to Earth's gravity following return from space

The consequence of exposure to microgravity on the otolith organs was studied by recording the responses of vestibular nerve afferents supplying the utricular otolith organ to inertial accelerations in four toadfish, Opsanus tau, sequentially for 5 days following two National Aeronautics and Space Administration shuttle orbital flights. Within the first day postflight, the magnitude of response to an applied translation was on average three times greater than for controls. The reduced gravitational acceleration in orbit apparently resulted in an upregulation of the sensitivity of utricular afferents. By 30 h postflight, responses were statistically similar to control. The time course of return to normal afferent sensitivity parallels the reported decrease in vestibular disorientation in astronauts following return from space.

manned↗

Horizontal vestibuloocular reflex evoked by high-acceleration rotations in the squirrel monkey. IV. Responses after spectacle-induced adaptation

The horizontal angular vestibuloocular reflex (VOR) evoked by sinusoidal rotations from 0.5 to 15 Hz and acceleration steps up to 3,000 degrees /s(2) to 150 degrees /s was studied in six squirrel monkeys following adaptation with x2.2 magnifying and x0.45 minimizing spectacles. For sinusoidal rotations with peak velocities of 20 degrees /s, there were significant changes in gain at all frequencies; however, the greatest gain changes occurred at the lower frequencies. The frequency- and velocity-dependent gain enhancement seen in normal monkeys was accentuated following adaptation to magnifying spectacles and diminished with adaptation to minimizing spectacles. A differential increase in gain for the steps of acceleration was noted after adaptation to the magnifying spectacles. The gain during the acceleration portion, G(A), of a step of acceleration (3,000 degrees /s(2) to 150 degrees /s) increased from preadaptation values of 1.05 +/- 0.08 to 1.96 +/- 0.16, while the gain during the velocity plateau, G(V), only increased from 0.93 +/- 0.04 to 1.36 +/- 0.08. Polynomial fits to the trajectory of the response during the acceleration step revealed a greater increase in the cubic than the linear term following adaptation with the magnifying lenses. Following adaptation to the minimizing lenses, the value of G(A) decreased to 0.61 +/- 0.08, and the value of G(V) decreased to 0.59 +/- 0.09 for the 3,000 degrees /s(2) steps of acceleration. Polynomial fits to the trajectory of the response during the acceleration step revealed that there was a significantly greater reduction in the cubic term than in the linear term following adaptation with the minimizing lenses. These findings indicate that there is greater modification of the nonlinear as compared with the linear component of the VOR with spectacle-induced adaptation. In addition, the latency to the onset of the adapted response varied with the dynamics of the stimulus. The findings were modeled with a bilateral model of the VOR containing linear and nonlinear pathways that describe the normal behavior and adaptive processes. Adaptation for the linear pathway is described by a transfer function that shows the dependence of adaptation on the frequency of the head movement. The adaptive process for the nonlinear pathway is a gain enhancement element that provides for the accentuated gain with rising head velocity and the increased cubic component of the responses to steps of acceleration. While this model is substantially different from earlier models of VOR adaptation, it accounts for the data in the present experiments and also predicts the findings observed in the earlier studies.

NASA Discipline Neuroscience↗

Variable practice with lenses improves visuo-motor plasticity

Novel sensorimotor situations present a unique challenge to an individual's adaptive ability. Using the simple and easily measured paradigm of visual-motor rearrangement created by the use of visual displacement lenses, we sought to determine whether an individual's ability to adapt to visuo-motor discordance could be improved through training. Subjects threw small balls at a stationary target during a 3-week practice regimen involving repeated exposure to one set of lenses in block practice (x 2.0 magnifying lenses), multiple sets of lenses in variable practice (x 2.0 magnifying, x 0.5 minifying and up-down reversing lenses) or sham lenses. At the end of training, adaptation to a novel visuo-motor situation (20-degree right shift lenses) was tested. We found that (1) training with variable practice can increase adaptability to a novel visuo-motor situation, (2) increased adaptability is retained for at least 1 month and is transferable to further novel visuo-motor permutations and (3) variable practice improves performance of a simple motor task even in the undisturbed state. These results have implications for the design of clinical rehabilitation programs and countermeasures to enhance astronaut adaptability, facilitating adaptive transitions between gravitational environments.

NASA Discipline Neuroscience↗

Gravity and body mass regulation

The effects of altered gravity on body mass, food intake, energy expenditure, and body composition are examined. Metabolic adjustments are reviewed in maintenance of energy balance, neural regulation, and humoral regulation are discussed. Experiments with rats indicate that genetically obese rats respond differently to hypergravity than lean rats.

NASA Discipline Regulatory Physiology↗

Space motion sickness preflight adaptation training: preliminary studies with prototype trainers

Preflight training frequently has been proposed as a potential solution to the problem of space motion sickness. The paper considers successively the otolith reinterpretation, the concept for a preflight adaptation trainer and the research with the Miami University Seesaw, the Wright Patterson Air-Force Base Dynamic Environment Simulator and the Visually Coupled Airborne Systems Simulator prototype adaptation trainers.

NASA Discipline Neuroscience↗

Understanding metabolic alterations in space flight using quantitative models: fluid and energy balance

This report summarizes many of the results obtained during the Skylab program, on metabolic changes during weightlessness. The examination of the data was conducted following an integrated multi-disciplinary and multi-experimental approach. Emphasis is given on several major aspects of metabolic adaptation to space flight: fluid-electrolyte regulation, mechanisms of hormone disturbances, energy balance and etiology of weight loss. The aim is to obtain a composite picture of the fluid, electrolyte and energy response to weightlessness.

Non-NASA Center↗

Spacelab experiments on space motion sickness

Recent research results from ground and flight experiments on motion sickness and space sickness conducted by the Man Vehicle Laboratory are reviewed. New tools developed include a mathematical model for motion sickness, a method for quantitative measurements of skin pallor and blush in ambulatory subjects, and a magnitude estimation technique for ratio scaling of nausea or discomfort. These have been used to experimentally study the time course of skin pallor and subjective symptoms in laboratory motion sickness. In prolonged sickness, subjects become hypersensitive to nauseogenic stimuli. Results of a Spacelab-1 flight experiment are described in which four observers documented the stimulus factors for and the symptoms/signs of space sickness. The clinical character of space sickness differs somewhat from acute laboratory motion sickness. However SL-1 findings support the view that space sickness is fundamentally a motion sickness. Symptoms were subjectively alleviated by head movement restriction, maintenance of a familiar orientation with respect to the visual environment, and wedging between or strapping onto surfaces which provided broad contact cues confirming the absence of body motion.

Flight Experiment↗

Effects of 5 weeks of lower limb suspension on muscle size and strength

Lack of weight-bearing, as occurs in space, appears to be associated with reductions in strength and mass of skeletal muscle. Very limited data, however, is at hand describing changes in skeletal muscle size and function following manned space missions. Our current knowledge therefore is mainly based on studies of space flown rats. It is obvious though that this information, only in part can be extrapolated to humans. A few bed rest studies have demonstrated that decreases in strength and muscle size are substantial. At this time, however, the magnitude or time course of such changes either in response to space flight or simulations of microgravity have not been defined. In the last few years we have employed a human model to simulate unloading of lower limb skeletal muscles that occurs in microgravity. This model was essentially adopted from the rat hindlimb suspension technique. The purpose of this study was to assess the magnitude of decreases in muscle strength and size as a result of five weeks of unilateral lower limb suspension.

Non-NASA Center↗

Mechanisms of post-flight orthostatic intolerance

Post-flight orthostatic intolerance is a dramatic physiological consequence of human adaptation to microgravity made inappropriate by a sudden return to 1-G. The immediate mechanism is almost always a failure to maintain adequate tissue perfusion, specifically perfusion of the central nervous system, but vestibular dysfunction may occasionally be the primary cause. Orthostatic intolerance is present in a wide range of clinical disorders of the nervous and cardiovascular systems. The intolerance that is produced by spaceflight and 1-G analogs (bed rest, head-down tilt at a moderate angle, water immersion) is different from its clinical counterparts by being only transiently present in subjects who otherwise have normal cardiovascular and regulatory systems. However, the same set of basic pathophysiological elements should be considered in the analysis of any form of orthostatic intolerance.

Non-NASA Center↗

Cardiopulmonary adaptation to weightlessness

The lung is profoundly affected by gravity. The absence of gravity (microgravity) removes the mechanical stresses acting on the lung paranchyma itself, resulting in a reduction in the deformation of the lung due to its own weight, and consequently altering the distribution of fresh gas ventilation within the lung. There are also changes in the mechanical forces acting on the rib cage and abdomen, which alters the manner in which the lung expands. The other way in which microgravity affects the lung is through the removal of the gravitationally induced hydrostatic gradients in vascular pressures, both within the lung itself, and within the entire body. The abolition of a pressure gradient within the pulmonary circulation would be expected to result in a greater degree of uniformity of blood flow within the lung, while the removal of the hydrostatic gradient within the body should result in an increase in venous return and intra-thoracic blood volume, with attendant changes in cardiac output, stroke volume, and pulmonary diffusing capacity. During the 9 day flight of Spacelab Life Sciences-1 (SLS-1) we collected pulmonary function test data on the crew of the mission. We compared the results obtained in microgravity with those obtained on the ground in both the standing and supine positions, preflight and in the week immediately following the mission. A number of the tests in the package were aimed at studying the anticipated changes in cardiopulmonary function, and we report those in this communication.

short duration↗

The effects of gravity on the circadian timing system

The physiological system responsible for the temporal coordination of an organism is the circadian timing system (CTS). This system provides two forms of temporal coordination. First, the CTS provides for synchronization of the organism with the 24 hour period of the external environment. This synchronization of the organism with the environment is termed entrainment. Second, this system also provides for internal coordination of the various physiological, behavioral, and biochemical events within the organism. When either of these two temporal relationships are disturbed, various dysfunctions can be manifest within the organism. Homeostatic capacity of other physiological systems may be reduced. Performance is decreased and sleep disorders, mental health impairment (e.g., depression), jet lag syndrome, and shift work maladaptation frequently occur. Over the last several years, several studies have evaluated the potential influence of gravity on this physiological control system by examining changes in rhythmic characteristics of organisms exposed to altered gravitational environments. The altered gravitational environments have included the microgravity of spaceflight as well as hyperdynamic fields produced via centrifugation.

Review↗

Orientation and movement in unusual force environments

A manned space mission to Mars might take as long as 1 year each way. Consequently, artificial gravity is being considered as a way of preventing the debilitating effects of long-duration exposure to microgravity on the human body. The present article discusses some of the problems associated with adapting to the rotation levels that might be used to generate artificial gravity. It also describes how exposure to background-force levels greater or less than the 1-G force of Earth gravity affects orientation and movement control. The primary emphasis of the article is that human movement and orientation control are dynamically adapted to the 1-G force background of Earth and that accommodation to altered force levels or to rotating environments requires a wide range of adaptive changes.

Parabolic Flight↗

Vestibular factors influencing the biomedical support of humans in space

This paper will describe the biomedical support aspects of humans in space with respect to the vestibular system. The vestibular system is thought to be the primary sensory system involved in the short-term effects of space motion sickness although there is increasing evidence that many factors play a role in this complex set of symptoms. There is the possibility that an individual's inner sense of orientation may be strongly coupled with the susceptibility to space motion sickness. A variety of suggested countermeasures for space motion sickness will be described. Although there are no known ground-based tests that can predict space motion sickness, the search should go on. The long term effects of the vestibular system in weightlessness are still relatively unknown. Some preliminary data has shown that the otoconia are irregular in size and distribution following extended periods of weightlessness. The ramifications of this data are not yet known and because the data was obtained on lower order animals, definitive studies and results must wait until the space station era when higher primates can be studied for long durations. This leads us to artificial gravity, the last topic of this paper. The vestibular system is intimately tied to this question since it has been shown on Earth that exposure to a slow rotating room causes motion sickness for some period of time before adaptation occurs. If the artificial gravity is intermittent, will this mean that people will get sick every time they experience it? The data from many astronauts returning to Earth indicates that a variety of sensory illusions are present, especially immediately upon return to a 1-g environment. Oscillopsia or apparent motion of the visual surround upon head motion along with inappropriate eye motions for a given head motion, all indicate that there is much to be studied yet about the vestibular and CNS systems reaction to a sudden application of a steady state acceleration field like 1-g. From the above information it is obvious that the vestibular system does have unique requirements when it comes to the biomedical support of space flight. This is not to say that other areas such as cardiovascular, musculo-skeletal, immunological and hematological systems do not have their own unique requirements but that possible solutions to one system can provide continuing problems to another system. For example, artificial gravity might be helpful for long term stabilization of bone demineralization or cardiovascular deconditioning but might introduce a new set of problems in orientation, vestibular conflict and just plain body motion in a rotating space vehicle.

Non-NASA Center↗

Biomedical support of man in space

In its broadest sense, biomedical support of man in space must not be limited to assisting spacecraft crew during the mission; such support should also ensure that flight personnel be able to perform properly during landing and after leaving the craft. Man has developed mechanisms that allow him to cope with specific stresses in his normal habitat; there is indisputable evidence that, in some cases, the space environment, by relieving these stresses, has also allowed the adaptive mechanisms to lapse, causing serious problems after re-entry. Inflight biomedical support must therefore include means to simulate some of the normal stresses of the Earth environment. In the area of cardiovascular performance, we have come to rely heavily on complex feedback mechanisms to cope with two stresses, often combined: postural changes, which alter the body axis along which gravitational acceleration acts, and physical exercise, which increases the total load on the system. Unless the appropriate responses are reinforced continuously during flight, crew members may be incapacitated upon return. The first step in the support process must be a study of the way in which changes in g, even of short duration, affect these responses. In particular we should learn more about effects of g on the "on" and "off" dynamics, using a variety of approaches: increased acceleration on one hand at recumbency, immersion, lower body positive pressure, and other means of simulating some of the effects of low g, on the other. Once we understand this, we will have to determine the minimal exposure dose required to maintain the response mechanisms. Finally, we shall have to design stresses that simulate Earth environment and can be imposed in the space vehicle. Some of the information is already at hand; we know that several aspects of the response to exercise are affected by posture. Results from a current series of studies on the kinetics of tilt and on the dynamics of readjustment to exercise in different postures will be presented and discussed.

NASA Discipline Cardiopulmonary↗

Perception of tilt (somatogravic illusion) in response to sustained linear acceleration during space flight

During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural and head vertical (dorsoventral) linear accelerations of 0.5 g and 1 g during constant velocity rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear-out or right-ear-out (Gy centrifugation), or lay supine along the centrifuge arm with their head off-axis (Gz centrifugation). Pre-flight centrifugation, producing linear accelerations of 0.5 g and 1 g along the Gy (interaural) axis, induced illusions of roll-tilt of 20 degrees and 34 degrees for gravito-inertial acceleration (GIA) vector tilts of 27 degrees and 45 degrees , respectively. Pre-flight 0.5 g and 1 g Gz (head dorsoventral) centrifugation generated perceptions of backward pitch of 5 degrees and 15 degrees , respectively. In the absence of gravity during space flight, the same centrifugation generated a GIA that was equivalent to the centripetal acceleration and aligned with the Gy or Gz axes. Perception of tilt was underestimated relative to this new GIA orientation during early in-flight Gy centrifugation, but was close to the GIA after 16 days in orbit, when subjects reported that they felt as if they were 'lying on side'. During the course of the mission, inflight roll-tilt perception during Gy centrifugation increased from 45 degrees to 83 degrees at 1 g and from 42 degrees to 48 degrees at 0.5 g. Subjects felt 'upside-down' during in-flight Gz centrifugation from the first in-flight test session, which reflected the new GIA orientation along the head dorsoventral axis. The different levels of in-flight tilt perception during 0.5 g and 1 g Gy centrifugation suggests that other non-vestibular inputs, including an internal estimate of the body vertical and somatic sensation, were utilized in generating tilt perception. Interpretation of data by a weighted sum of body vertical and somatic vectors, with an estimate of the GIA from the otoliths, suggests that perception weights the sense of the body vertical more heavily early in-flight, that this weighting falls during adaptation to microgravity, and that the decreased reliance on the body vertical persists early post-flight, generating an exaggerated sense of tilt. Since graviceptors respond to linear acceleration and not to head tilt in orbit, it has been proposed that adaptation to weightlessness entails reinterpretation of otolith activity, causing tilt to be perceived as translation. Since linear acceleration during in-flight centrifugation was always perceived as tilt, not translation, the findings do not support this hypothesis.

STS-90 Shuttle Project↗

Dynamics of the human linear vestibulo-ocular reflex at medium frequency and modification by short-term training

We study here the effect of a short-term training paradigm on the gain and phase of the human translational VOR (the linear VOR: LVOR). Subjects were exposed to lateral sinusoidal translations on a sled, at 0.5 Hz, 0.3 g peak acceleration. With subjects tracking a remembered target at 1.2 m, the LVOR (slow-phase) under these conditions typically has a phase lead or lag, and a gain that falls short of compensatory. To induce short-term adaptation (training), we presented an earth-fixed visual scene at 1.2 m during sinusoidal translation (x 1 viewing) for 20 minutes, so as to drive the LVOR toward compensatory phase and gain. We examined both the slow-phase and the saccadic responses to these stimuli. Testing after training showed changes in slow-component gain and phase which were mostly but not always in the compensatory direction. These changes were more consistent in naive subjects than in subjects who had previous LVOR experience. Changes in gain were seen with step as well as sinusoidal test stimuli; gain changes were not correlated with vergence changes. There was a strong correlation between gain changes and phase changes across subjects. Fast phases (catch-up saccades) formed a large component of the LVOR under our testing conditions (approximately 30% of the changes in gain but not in phase due to training.

Non-NASA Center↗

Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Clinical Trial↗