Experiments on rotating externally pressurized air journal bearings. Part 2 - Attitude angle and air flow
Air flow and attitude angle compared with theory for rotating externally pressurized air journal bearings
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Air flow and attitude angle compared with theory for rotating externally pressurized air journal bearings
Load and stiffness characteristics of rotating externally pressurized air journal bearings
Global meteorological observations are essential in initialization and assimilation of numerical weather prediction (NWP) models. Many key weather variables such as temperature, humidity, and wind can be relatively well observed by in-situ and remote techniques from surface, suborbital and orbital platforms. However, sea surface air pressure cannot be well-sampled. Over open oceans, the pressure can only be observed by very limited buoys, ships, and oceanic platforms. There is no operational remote sensing method available for the crucial dynamic variable of the Earth’s climate and weather systems. Advanced techniques for global sea level pressure (SLP) observations are urgently needed for improving NWP models, particularly for improvement of severe weather forecasts. Recent studies on the space and airborne Microwave BArometric Radar and Sounder (MBARS) systems provide a great potential to fill the SLP observational gap. The systems studied have three channels with center frequencies at 65.5, 67.76 and 70 GHz. These channels are designed to operate at atmospheric oxygen (O2) absorption bands for column O2 mass measurements. When sea surface returns of spectrally closely-spaced paired channels are measured, surface reflection and atmospheric attenuation other than O2 are very similar, but the difference in O2 absorption is substantial. Thus, the differential absorption loss of this frequency pair leads to measures of atmospheric O2 amount. For the residual absorption loss caused by other agents, a third frequency having the same spectral space to the weak absorption frequency of the first pair can be used, which forms the second pair and produces the same residual as the first pair. Removal of the residual of this second pair from the first pair can further mitigate environmental impacts. Thus, this 3-channel approach will provide precise O2 amount retrievals. Since oxygen is well mixed in the atmosphere, the column air mass or SLP can be obtained. Currently, MBARS is rapidly maturing its advanced technology. An upcoming airborne field flight campaign is planned in late 2024. The 3-channel approach will be use in SLP retrievals. This MBARS team will discuss the physics-based SLP retrieval technique and report latest progresses in this upcoming AGU annual meeting.
Human body adaptive reaction to increased air pressure based on higher nervous system study
The effects were studied of low-pressure air on contamination and corrosion in the tantalum alloy T-111/lithium system at 980 and 1260 C. Capsules of T-111 containing lithium were exposed to six vacuum levels between 1 x 10 to the 8th power and 0.0003 torr by controlled air leakage into a vacuum system. Capsules exposed at 980 C and 0.0002 torr failed from intragranular oxidation. The remainder of the capsules completed the 96-hour tests. The depth of oxygen contamination was greater at 980 C than at 1260 C. Tests made at 0.0001 and 0.00001 torr levels caused large increases in the oxygen content of the T-111. Tests at 0.000001 torr or less produced no significant contamination. No lithium corrosion of the T-111 was observed under any of the conditions.
Results of measured and calculated shift coefficients are presented for 170 absorption lines of H2O in five vibrational-rotational bands. The measurements have been carried out using highly sensitive laser spectrometers with a resolution of at least 0.01/cm; the calculations are based on the Anderson-Tsao-Curnutte-Frost method. Good agreement is obtained between the theoretical and experimental values of the shift coefficients of H2O lines due to N2, O2, and air pressure.
Samples of liquid oxygen, high pressure nitrogen, low pressure nitrogen, and missile grade air were studied to determine the hydrocarbon concentrations. Concentration of the samples was achieved by adsorption on a molecular sieve and activated charcoal. The trapped hydrocarbons were then desorbed and transferred to an analytical column in a gas chromatograph. The sensitivity of the method depends on the volume of gas passed through the adsorbent tubes. The value of the method was verified through recoverability and reproducibility studies. The use of this method enables LOX, GN2, and missile grade air systems to be routinely monitored to determine low level increases in specific hydrocarbon concentration that could lead to potentially hazardous conditions.
Development and characteristics of high pressure control valve
Information regarding the safety limits of hydrocarbons in liquid and gaseous oxygen, the steps taken for hydrocarbon removal from liquified gases, and the analysis of the contaminants was searched and the results are presented. The safety of hydrocarbons in gaseous systems was studied, and the latest hydrocarbon test equipment and methodology is reviewed. A detailed sampling and analysis plan is proposed to evaluate high pressure GN2 and LOX systems.
This paper discusses a Reliability, Availability, and Maintainability (RAM) independent assessment conducted to support the refurbishment of the Compressor Station at the NASA Langley Research Center (LaRC). The paper discusses the methodologies used by the assessment team to derive the repair by replacement (RR) strategies to improve the reliability and availability of the Compressor Station (Ref.1). This includes a RAPTOR simulation model that was used to generate the statistical data analysis needed to derive a 15-year investment plan to support the refurbishment of the facility. To summarize, study results clearly indicate that the air compressors are well past their design life. The major failures of Compressors indicate that significant latent failure causes are present. Given the occurrence of these high-cost failures following compressor overhauls, future major failures should be anticipated if compressors are not replaced. Given the results from the RR analysis, the study team recommended a compressor replacement strategy. Based on the data analysis, the RR strategy will lead to sustainable operations through significant improvements in reliability, availability, and the probability of meeting the air demand with acceptable investment cost that should translate, in the long run, into major cost savings. For example, the probability of meeting air demand improved from 79.7 percent for the Base Case to 97.3 percent. Expressed in terms of a reduction in the probability of failing to meet demand (1 in 5 days to 1 in 37 days), the improvement is about 700 percent. Similarly, compressor replacement improved the operational availability of the facility from 97.5 percent to 99.8 percent. Expressed in terms of a reduction in system unavailability (1 in 40 to 1 in 500), the improvement is better than 1000 percent (an order of magnitude improvement). It is worthy to note that the methodologies, tools, and techniques used in the LaRC study can be used to evaluate similar high value equipment components and facilities. Also, lessons learned in data collection and maintenance practices derived from the observations, findings, and recommendations of the study are extremely important in the evaluation and sustainment of new compressor facilities.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Voltage breakdown in low pressure regions and resulting electrical corona
The pressure measurement was made by a Model 830J Rosemont sensor which utilized the principle of a changing pressure to change correspondingly the capacitance of the pressure sensitive element. The sensor's range was stated to be from zero to 100 Torr (14 km); however, the sensor was not activated until an altitude of 20 km (41 Torr) was reached during the balloon ascent. The resolution of the sensor was specified by the manufacturer as infinitesimal; however, associated electronic and pressure readout systems limit the resolution to .044 Torr. Thus in the vicinity of an altitude of 30 km the pressure resolution corresponded to an altitude resolution of approximately 33 meters.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.