Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ba₁₋ₓSrₓFeO₃₋ᵧ as an Improved Oxygen Carrier for Chemical Looping Air Separation: A Computational and Experimental Study

Chemical looping air separation (CLAS) is a promising method to generate pure carbon-dioxide from fuel combustion with a pure oxygen stream, which is produced through the capture, and targeted release, of oxygen from the atmosphere using a solid oxide carrier. The performance of this process depends on the redox characteristics of the oxide carrier. Using experimental oxygen-temperature-programmed desorption (TPD) and thermogravimetric analysis (TGA), the study shows that Ba₀․₇₅Sr₀․₂₅FeO₃ has improved oxygen storage capacity (OSC), oxidation, and reduction kinetics over pristine SrFeO₃ at temperatures ranging from 300-500 °C. The redox energetics computed by using first-principles density functional theory (DFT) calculations also depict the measured trend establishing it as an important descriptor of the measured performance. The Ba₁₋ₓSrₓFeO₃₋ᵧ depicts a Sr-substitution and oxygen stoichiometry induced structural phase transition from hexagonal at low temperatures to pseudo-cubic phase with higher OSC up to T=400 °C. Also, the mechanism leading to this structural phase transition is identified by performing electronic and vibrational structural calculations. This presentation was given on March 8, 2024 at the APS March Meeting in Minneapolis, MN.

Acharya, Shree Ram↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

Redox-Based Chemical Looping Large-Scale Air Separation Unit Designs Using Perovskite Material

Oxygen production by means of air separation through redox cycle reactions of Sr 1–x Ca x FeO 3-δ perovskite particles is examined numerically in the context of modular large-scale units. Fixed-bed, multicomponent reactor designs allowing for the recovery of the energy released by the exothermic oxidation (or adsorption) to enhance the endothermic reduction (or desorption) of the perovskite material are considered and compared against a baseline cylindrical packed bed. Numerically, the gas–solid reacting system is approximated as a single-phase reacting gas flow through a porous medium of constant porosity. The redox kinetics account for the oxygen nonstoichiometry of the perovskite, which exhibits a dependence on the temperature and the oxygen partial pressure, in order to describe some mechanisms of the oxygen vacancies. Results show that the spontaneous release of the oxygen from the lattice arrangements, through the thermal management of the heat of the oxidation reaction from the geometrical design of the reactors, can be enhanced up to 4% with respect to the baseline oxygen production of 0.201 g O 2 ·h –1 ·g perovskite –1 with the cylindrical packed bed, in the condition of operations in this work, at 500 °C. Sensitivity to the operation temperature showed that the oxygen production is greatly enhanced by approximately 30% with the increase of the temperature from 500 to 550 °C. We report this result is consistent with experimental observations of faster release of the oxygen from the lattice arrangements of this perovskite at 550 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An A- and B-Site Substitutional Study of SrFeO3−δ Perovskites for Solar Thermochemical Air Separation

An A‑ and B‑site substitutional study of SrFeO3−δ perovskites (A’xA1−xB’yB1−yO3−δ, where A = Sr and B = Fe) was performed for a two‑step solar thermochemical air separation cycle. The cycle steps encompass (1) the thermal reduction of A’xSr1−xB’yFe1−yO3−δ driven by concentrated solar irradiation and (2) the oxidation of A’xSr1−xB’yFe1−yO3−δ in air to remove O2, leaving N2. The oxidized A’xSr1−xB’yFe1−yO3−δ is recycled back to the first step to complete the cycle, resulting in the separation of N2 from air and concentrated solar irradiation. A-site substitution fractions between 0 ≤ x ≤ 0.2 were examined for A’ = Ba, Ca, and La. B-site substitution fractions between 0 ≤ y ≤ 0.2 were examined for B’ = Cr, Cu, Co, and Mn. Samples were prepared with a modified Pechini method and characterized with X-ray diffractometry. The mass changes and deviations from stoichiometry were evaluated with thermogravimetry in three screenings with temperature- and O2 pressure-swings between 573 and 1473 K and 20% O2/Ar and 100% Ar at 1 bar, respectively. A’ = Ba or La and B’ = Co resulted in the most improved redox capacities amongst temperature- and O2 pressure-swing experiments.

14 SOLAR ENERGY↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

A data-driven linear formulation of the optimal demand response scheduling problem for an industrial air separation unit

Demand response (DR) has become a key element in balancing the power grid as the contribution of time-varying renewable power generation increases. Chemical plants are appealing candidates for DR programs as they offer large, concentrated and flexible loads. DR participation calls for frequent production rate changes over time scales that overlap with the dominant dynamics of the plant. Production scheduling should therefore consider the process dynamics explicitly. Here we present a data-driven approach for modelling the scheduling-relevant dynamics based on historical closed-loop operating data using autoregressive with extra inputs (ARX) models. We introduce a new, linear scheduling problem formulation based on the ARX representation, and demonstrate its implementation on an industrial air separation unit.

42 ENGINEERING↗

Single-column cryogenic air separation: enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N2-enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde's single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde's single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O2. However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

Cheng, Mao↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Air separation via two-step solar thermochemical cycles based on SrFeO 3-δ and (Ba,La) 0.15 Sr 0.85 FeO 3-δ perovskite reduction/oxidation reactions to produce N 2 : rate limiting mechanism(s) determination

Two-step solar thermochemical cycles based on reversible reactions of SrFeO 3–δ and (Ba,La) 0.15 Sr 0.85 FeO 3–δ perovskites were considered for air separation. The cycle steps encompass (1) the thermal reduction of SrFeO 3–δ or (Ba,La) 0.15 Sr 0.85 FeO 3–δ perovskites driven by concentrated solar irradiation and (2) oxidation in air to remove O 2 and produce N 2 . Rate limiting mechanisms were examined for both reactions using a combination of isothermal and non-isothermal thermogravimetry for temperature-swings between 673 and 1373 K, heating rates of 10, 20, and 50 K min –1 , and O 2 pressure-swings between 20% O 2 /Ar and 100% Ar at atmospheric pressure. Evolved O 2 and associated lag due to transport behavior were measured with gas chromatography and used with measured sample temperatures to predict equilibrium compositions from a compound energy formalism thermodynamic model. Measured and predicted chemical equilibrium changes in deviation from stoichiometry were compared. Rapid chemical kinetics were observed as the samples equilibrated rapidly for all conditions, indicative that heat and mass transfer were the rate limiting mechanisms. Furthermore, the effects of bulk diffusion (or gas diffusion through the bed or pellet) were examined using pelletized and loose powdered samples and determined to have no discernable impact.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adsorption-based membranes for air separation using transition metal oxides

In this work, we use computational modeling to examine the viability of adsorption-based pore-flow membranes for separating gases when a purely size-based separation strategy is ineffective. Using molecular dynamics simulations of O 2 and N 2 , we model permeation through a nanoporous graphene membrane. Permeation is assumed to follow a five-step adsorption-based pathway, with desorption being the rate-limiting step. Using this model, we observe increased selectivity between O 2 and N 2 , resulting from increased adsorption energy differences. We explore the limits of this strategy, providing an initial set of constraints that need to be satisfied to allow for selectivity. Finally, we provide a preliminary exploration of some transition metal oxides that appear to satisfy those conditions. Using density functional theory calculations, we confirm that these oxides possess adsorption energies needed to operate as adsorption-based pore-flow membranes. These adsorption energies provide a suitable motivation to examine adsorption-based pore-flow membranes as a viable option for air separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗