Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air source heat pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Evaluating Air-Source Heat Pumps with Distributed Energy Resources in REopt

This training introduces attendees to NREL's REopt(R) web tool and its capabilities in evaluating air-source heat pumps (ASHP) alongside distributed energy resources (DERs). Designed for energy managers, facility operators, and sustainability managers, this session will explore how REopt provides techno-economic analysis to assess the financial viability of ASHP while identifying synergies with solar PV and battery storage. Participants will gain practical insights into using REopt to optimize energy strategies, reduce costs, and improve site resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pumps for all? Distributions of the costs and benefits of residential air-source heat pumps in the United States

Electrification of fossil-fuel combustion in buildings is a key component of achieving global greenhouse gas emissions targets. We use physics simulations of 550,000 statistically representative households to analyze distributions of the costs and benefits of three air-to-air heat pump performance levels, with and without insulation upgrades, across the diversity of the US housing stock. We find positive greenhouse gas reductions in every US state for all performance levels across five 2022-2038 electric grid scenarios, with full adoption reducing national emissions by 5%-9%. We find that air-to-air heat pumps could be cost effective without subsidies in 59% of households (65 million). However, efficiency is key: whereas minimum-efficiency equipment could increase energy bills in 39% of households, this fraction is only 19% when also upgrading insulation or 5% when using higher-efficiency equipment, though both strategies have higher upfront costs. Such affordability challenges could be addressed through supportive incentives, policy, and innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Residential Air Source Heat Pump using Low–Global Warming Potential Refrigerants

We report low–global warming potential refrigerants can significantly reduce the direct emissions of CO 2 originating from HVAC systems. However, high-efficiency systems are needed to reduce indirect CO 2 emissions. In this study, an R410A residential 5-Ton heat pump was optimized using R32, R454A, R454B, R454C, and R455A. Among these options, R455A and R454C have the lowest global warming potential but have lower volumetric capacity and high glide. Optimization results using 5 mm tube heat exchangers showed 12.4% to 19.1% efficiency improvements and 13% to 33% reduction in CO 2 emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Deep learning–based digital twins for heat pumps

Heat pumps are effective cooling and heating appliances to save energy in buildings. However, traditional heat pump models are challenging to integrate with building demands in a co-simulation environment because of the nonlinear thermodynamics of refrigerants. Developing digital twin representatives for heat pumps capable of faster calculations with good accuracy is desirable. This study aimed to establish a generic deep learning–based digital twin for heat pumps with a large amount of high-fidelity data. Two refrigerants for two different heat pumps were considered: an air source heat pump with refrigerant R-410A, an air source heat pump with refrigerant CO 2 , a water source heat pump with refrigerant R-410A, and a water source heat pump with refrigerant CO 2 . Furthermore, results showed that the deep learning (long short-term memory) models effectively represented these four heat pumps as a digital twin: (a) accuracy for training and testing showed smaller than 0.02 for heating electricity and heating demands, and (b) the digital twins showed good consistency with original data for heating electricity and heating demands (root mean square errors of less than 0.12 W and 0.19 W, respectively). Therefore, deep learning–based heat pump models can be used in the co-simulation of building mechanical systems.

Air source heat pump↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗