Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of Factors Affecting Powdered Drug Reconstitution in Microgravity

Owing to the high cost of transporting mass into space, and the small volume available for equipment in the Space Shuttle Orbiter and the International Space Station, refrigeration space is extremely limited. For this reason, there exists strong motivation for transporting certain drugs in powdered form so that they do not require refrigeration. When needed, the powdered drug will be mixed with saline to obtain a liquid form that may be injected intravenously. While this is a relatively simple task in a 1-G environment, there are some difficulties that may be encountered in 0-G. In non-accelerated spaceflight, gravitational and inertial forces are eliminated allowing other smaller forces, such as capillary forces and surface tension, to dominate the behavior of fluids. For instance, water slowly ejected from a straw will tend to form a sphere, while fluid in a container will tend to wet the inside surface forming a highly rounded meniscus. Initial attempts at mixing powdered drugs with saline in microgravity have shown a tendency toward forming foamy emulsions instead of the desired homogeneous solution. The predominance of adhesive forces between the drug particles and the interface tensions at the gas/liquid and solid/liquid interfaces drastically reduce the rate of deaggregation of the drug powder and also reduce the rate of absorption of saline by the powder mass. In addition, the capillary forces cause the saline to wet the inside of the container, thus trapping air bubbles within the liquid. The rate of dissolution of a powder drug is directly proportional to the amount of surface area of the solid that is exposed to liquid solvent. The surface area of drug that is in contact with the liquid is greatly reduced in microgravity and, as a result, the dissolution rate is reduced as well. The KC-135 research described here was aimed at evaluating the extent to which it is possible to perform drug reconstitution in the weightlessness of parabolic flight using standard pharmacological supplies. The experiment included a parametric assessment of possible factors affecting the reconstitution process. The specific questions that we wished to answer were: (1) Is it possible to reconstitute powdered drugs in weightlessness using standard pharmacological equipment? (2) What are the differences between drug reconstitution in a 1-G and a 0-G environment? (3) What techniques of mixing the drug powder and diluent are more successful? (4) What physical and chemical factors play a role in determining the success of mixing and dissolution? (5) Is it necessary to employ crewmember and equipment restraints during the reconstitution process?

Schaffner, Grant↗

Thermographic Analysis of Composite Cobonds on the X-33

During the manufacture of the X-33 liquid hydrogen (LH2) Tank 2, a total of thirty-six reinforcing caps were inspected thermographically. The cured reinforcing sheets of graphite/epoxy were bonded to the tank using a wet cobond process with vacuum bagging and low temperature curing. A foam filler material wedge separated the reinforcing caps from the outer skin of the tank. Manufacturing difficulties caused by a combination of the size of the reinforcing caps and their complex geometry lead to a potential for trapping air in the bond line. An inspection process was desired to ensure that the bond line was free of voids before it had cured so that measures could be taken to rub out the entrapped air or remove the cap and perform additional surface matching. Infrared thermography was used to perform the precure "wet bond" inspection as well as to document the final "cured" condition of the caps. The thermal map of the bond line was acquired by heating the cap with either a flash lamp or a set of high intensity quartz lamps and then viewing it during cool down. The inspections were performed through the vacuum bag and voids were characterized by localized hot spots. In order to ensure that the cap had bonded to the tank properly, a post cure "flash heating" thermographic investigation was performed with the vacuum bag removed. Any regions that had opened up after the preliminary inspection or that were hidden during the bagging operation were marked and filled by drilling small holes in the cap and injecting resin. This process was repeated until all critical sized voids were filled.

Russell, Samuel S.↗

Thermographic Analysis of Composite Cobonds on the X-33

During the manufacture of the X-33 liquid hydrogen (LH2) Tank 2, a total of 36 reinforcing caps were inspected thermographically. The cured reinforcing sheets of graphite/epoxy were bonded to the tank using a wet cobond process with vacuum bagging and low temperature curing. A foam filler material wedge separated the reinforcing caps from the outer skin of the tank. Manufacturing difficulties caused by a combination of the size of the reinforcing caps and their complex geometry lead to a potential for trapping air in the bond line. An inspection process was desired to ensure that the bond line was free of voids before it had cured so that measures could be taken to rub out the entrapped air or remove the cap and perform additional surface matching. Infrared thermography was used to perform the procure 'wet bond' inspection as well a to document the final 'cured' condition of the caps. The thermal map of the bond line was acquired by heating the cap with either a flash lamp or a set of high intensity quartz lamps and then viewing it during cool down. The inspections were performed through the vacuum bag and voids were characterized by localized hot spots. In order to ensure that the cap had bonded to the tank properly, a post cure 'flash heating' thermographic investigation was performed with the vacuum bag removed. Any regions that had opened up after the preliminary inspection or that were hidden during the bagging operation were marked and filled by drilling small holes in the cap and injecting resin. This process was repeated until all critical sized voids were filled.

Russell, S. S.↗

Validation of Long Bone Mechanical Properties from Densitometry

The objective of this study was to assess whether cross-sectional areal properties, calculated from densitometry, correlate to the true flexural properties. Right and left male embalmed tibiae were used in the study. Prior to scanning, the proximal end of each tibia was potted in a fixture with registration pins, flushed thoroughly with water under pressure to remove trapped air, and then placed in a constant thickness water bath attached to a precision indexer. Two sets of three scans of the entire tibia were taken with an Hologic QDR 1000/W densitometer at rotations of 0, 45, and 90 degrees about the tibia long axis. An aluminum step phantom and a bone step phantom, machined from bovine cortical bone, were also in the bath and scanned separately. Pixel attenuation data from the two sets of scans were averaged to reduce noise. Pixel data from the high energy beam were then converted to equivalent thicknesses using calibration equations. Cross-sectional areal properties (centroid, principal area moments and principal angle) along the length were computed from the three registered scans using methods developed in our laboratory. Flexural rigidities. Four strain gages were bonded around the circumference of each of 5 cross-sections encompassing the entire diaphysis. A known transverse load was then applied to the distal end and the bone was rotated 360 degrees in eight increments of 45 degrees each. Strains from the eight orientations were analyzed along with the known applied bending moments at each section to compute section centroids, curvatures, principal flexural rigidities and principal angle. Reference axes between the two methods were maintained within +/- 0.5 degrees using an electronic inclinometer. Principal angles (flexural - areal) differed by -2.0 +/- 4.0 degrees, and 1.0 +/- 2.5 degrees for the right and left tibia, respectively. Section principal flexural rigidities were highly correlated to principal areal moments (right: r(sup 2)= 0.997; left: r(sup 2)= 0.978) indicating a nearly constant effective flexural modulus. Right and left tibia exhibited a very high degree of symmetry when comparing either flexural or areal properties. To our knowledge this is the first study to validate the use of densitometry (DXA) to predict three dimensional structural properties of long bones. Our initial results support the conclusion that bone mineral and its distribution are the primary determinants of flexural modulus and rigidity.

Whalen, R.↗

Nanomanufacturing of Graphene Nanosheets Through Hole Engineering

Facile and scalable fabrication of highly dense and high quality graphene films and articles is extremely attractive for a range of electronic and mechanical applications. Pristine, high quality graphene with its inherent impermeability poses challenges in fabricating dense films and thick parts with high electrical conductivity due to the difficulty in removing trapped air and/or solvents used in various fabrication methods. To overcome this deficiency, nano-holes were intentionally created in pristine graphene (“holey graphene”) with an average diameter of approximately 15 nm. The holes serve as pathways for the rapid removal of gases or liquids and enable the fabrication of dense holey graphene nanostructures. Subsequently, a high temperature process is applied to effectively repair the nano-holes and recover the high quality graphene conjugated network. Through the creation and repair of the nano-holes, dense graphene articles were created that exhibited an ultrahigh conductivity of 2209 S/cm and a high carrier mobility of 673 cm2V-1s-1. This unique processing methodology enables the facile and scalable fabrication of high quality graphene constructs for a variety of applications.

Yanan Chen↗

Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers (Final Technical Report)

This report summarizes the carbon capture research and development conducted by The State University of New York at Buffalo (UB) and GTI Energy (GTI) for award “DE-FE0031969: Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers” sponsored by the U.S. Department of Energy (DOE). The objective of this project is to develop an innovative sorbent structure of trapped small amines in HNC embedded in PEF for DAC. This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An innovative sorbent structure of trapped small amines in hierarchical nanoporous capsules (HNC) embedded in porous electrospun fibers (PEF) was developed for direct air capture (DAC). This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An interfacial polymerization process was developed, which utilized loaded amines inside mesoporous silica and trimesoyl chloride (TMC) dissolved in organic solvents as the precursors, to generate a polyamide (PA) coating layer on mesoporous silica and thus trap amines. Reaction conditions, including TMC concentration, organic solvents, reaction time, etc., for interfacial polymerization were optimized to effectively trap loaded amines, and cyclic heating-cooling operation was conducted to evaluate the coating quality. Larger pore volume mesoporous silica was also synthesized to increase amine loading and thus increase CO 2 capacity. The optimized sorbent material exhibited CO 2 capacity as high as 4.88 mmol/g under humid DAC conditions and negligible loss (<1%) during 10 cyclic heating-cooling operations. The optimized PA-coated sorbent also showed fast adsorption and desorption kinetics, with <20% t1/2 increase compared to uncoated sorbent. PEF fabrication conditions, including organic solvents for dissolving core and shell polymers, voltage, distance from the nozzle to the collection panel, etc. were adjusted to better incorporate HNC. After incorporating the optimized sorbent material into PEF, the structured sorbent had a CO 2 capacity of approximately 4.0 mmol/g under humid DAC conditions, with capacity loss of 0.17% per cycle and t1/2 increase less than 10%. A techno-economic analysis (TEA) for the process design for a DAC system based on our developed sorbent structure of trapped small amines in HNC embedded in PEF was conducted. The process design included process description and major equipment sizing and energy and mass balances in addition to scale-up research results and estimated capture cost. Aspen Adsorption Simulator was used to fit the experimentally measured breakthrough curves and extract equilibrium and kinetic data of the optimized sorbent. Our results indicated that for a DAC plant with CO 2 productivity of 3,000 tonne/year, the levelized cost of CO 2 capture was $\$$612/tonne, with the largest contribution of 44.33% from the fixed operation cost. Increasing CO 2 productivity, while maintaining similar fixed operation cost, is expected to significantly reduce the CO 2 capture cost. A sensitivity study was also conducted to understand the influence of total plant cost, sorbent cost, CO 2 concentration in the feed, sorbent mat lifetime, sorbent regeneration electricity, and adsorption blower pressure drop on the levelized cost of CO 2 capture, revealing a capture cost range of $\$$520-870/tonne.

36 MATERIALS SCIENCE↗

Trapping light in air with membrane metasurfaces for vibrational strong coupling

Optical metasurfaces can manipulate electromagnetic waves in unprecedented ways at ultra-thin engineered interfaces. Specifically, in the mid-infrared (mid-IR) region, metasurfaces have enabled numerous biochemical sensing, spectroscopy, and vibrational strong coupling (VSC) applications via enhanced light-matter interactions in resonant cavities. However, mid-IR metasurfaces are usually fabricated on solid supporting substrates, which degrade resonance quality factors (Q) and hinder efficient sample access to the near-field electromagnetic hotspots. Besides, typical IR-transparent substrate materials with low refractive indices, such as CaF 2 , NaCl, KBr, and ZnSe, are usually either water-soluble, expensive, or not compatible with low-cost mass manufacturing processes. Here, we present novel free-standing Si-membrane mid-IR metasurfaces with strong light-trapping capabilities in accessible air voids. We employ the Brillouin zone folding technique to excite tunable, high-Q quasi-bound states in the continuum (qBIC) resonances with our highest measured Q-factor of 722. Leveraging the strong field localizations in accessible air cavities, we demonstrate VSC with multiple quantities of PMMA molecules and the qBIC modes at various detuning frequencies. Our new approach of fabricating mid-IR metasurfaces into semiconductor membranes enables scalable manufacturing of mid-IR photonic devices and provides exciting opportunities for quantum-coherent light-matter interactions, biochemical sensing, and polaritonic chemistry. The authors introduce a mid-IR metasurface fabricated by decorating a free-standing Si-membrane with air holes. The enhanced light-matter interactions in such air cavities enable vibrational strong coupling and advanced biochemical sensing.

infrared spectroscopy↗

Receptacle for Optical-Fiber Scraps

Small pieces of glass trapped by moving air. Device traps fibers in section of black air-conditioner filter material. Filter section rests on metal screen above axial fan, which pulls air down through filter. Fan is small, quiet unit of type ordinarily used to cool electronic equipment.

Nevin, R.↗

Modification of Bushing Test Rig and Research of Variable Inlet Guide Vane Bushings For Further Development of PM304 Bushings

PS304 is a high temperature solid lubricant coating comprised of a nickel-chrome binder, chrome oxide hardener, barium-calcium fluoride high temperature lubricant, and silver as the low temperature lubricant. This coating is used to lubricate Oil-Free Foil Air Bearings as they experience friction and wear during start up and shut down. The coating deposition process begins with undercutting the shaft. This area is then sandblasted to provide a rough surface for the coating to adhere to. The coating powder is then sent through the plasma spray gun and a reasonably thick layer is applied to the undercut area of the shaft. The coating is then ground down even with the surface of the shaft and gets a nice polished finish. The foil air bearings use the solid lubricant, as mentioned above, during start up and shut down. During normal operating conditions, generally above 2000RPM, the bearings utilize air as their lubricant. Foil air bearings are comprised of a thin top foil and a corrugated bump foil. They have an interference fit with the shaft before operation. As the air gets "trapped" between the top foil and the shaft, it presses the top foil against the bump foil, in turn compressing the bumps. As the bumps compress, it allows for the air to separate the top foil from the shaft, therefore, utilizing the trapped air as its lubricant.

Yanke, Anne↗

Bubble and Drop Nonlinear Dynamics (BDND)

Free drops and bubbles are weakly nonlinear mechanical systems that are relatively simple to characterize experimentally in 1-G as well as in microgravity. The understanding of the details of their motion contributes to the fundamental study of nonlinear phenomena and to the measurement of the thermophysical properties of freely levitated melts. The goal of this Glovebox-based experimental investigation is the low-gravity assessment of the capabilities of a modular apparatus based on ultrasonic resonators and on the pseudo- extinction optical method. The required experimental task is the accurate measurements of the large-amplitude dynamics of free drops and bubbles in the absence of large biasing influences such as gravity and levitation fields. A single-axis levitator used for the positioning of drops in air, and an ultrasonic water-filled resonator for the trapping of air bubbles have been evaluated in low-gravity and in 1-G. The basic feasibility of drop positioning and shape oscillations measurements has been verified by using a laptop-interfaced automated data acquisition and the optical extinction technique. The major purpose of the investigation was to identify the salient technical issues associated with the development of a full-scale Microgravity experiment on single drop and bubble dynamics.

Trinh, E. H.↗

Identification and Characterization of Persistent Cold Pool Events from Temperature and Wind Profilers in the Columbia River Basin

Cold pool events occur when deep layers of stable, cold air remain trapped in a valley or basin for multiple days, without mixing out from daytime heating. With large impacts on air quality, freezing events, and es-pecially on wind energy production, they are often poorly forecast by modern mesoscale numerical weather prediction (NWP) models. Understanding the characteristics of cold pools is, therefore, important to provide more accurate forecasts. This study analyzes cold pool characteristics with data collected during the Second Wind Forecast Improvement Project (WFIP2), which took place in the Columbia River basin and Gorge of Oregon and Washington from fall 2015 until spring 2017. A subset of the instrumentation included three microwave radiometer pro?lers, six radar wind pro?lers with radio acoustic sounding systems, and seven sodars, which together provided seven sites with collocated vertical pro?les of temperature, humidity, wind speed, and wind direction. Using these collocated observations, we developed a set of criteria to determine if a cold pool was present based on stability, wind speed, direction, and temporal continuity, and then developed an automated algorithm based on these criteria to identify all cold pool events over the 18 months of the ?eld project. Characteristics of these events are described, including statistics of the wind speed distributions and pro?les, stability conditions, cold pool depths, and descent rates of the cold pool top. The goal of this study is a better understanding of these characteristics and their processes to ultimately lead to improved physical parameterizations in NWP models, and consequently improve forecasts of cold pool events in the study region as well at other locations that experiences similar events.

McCaffrey, Katherine L.↗

Multisorbent tubes for collecting volatile organic compounds in spacecraft air

The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.

NASA Center JSC↗

Advanced Signal Processing Techniques Applied to Terahertz Inspections on Aerospace Foams

The space shuttle's external fuel tank is thermally insulated by the closed cell foams. However, natural voids composed of air and trapped gas are found as by-products when the foams are cured. Detection of foam voids and foam de-bonding is a formidable task owing to the small index of refraction contrast between foam and air (1.04:1). In the presence of a denser binding matrix agent that bonds two different foam materials, time-differentiation of filtered terahertz signals can be employed to magnify information prior to the main substrate reflections. In the absence of a matrix binder, de-convolution of the filtered time differential terahertz signals is performed to reduce the masking effects of antenna ringing. The goal is simply to increase probability of void detection through image enhancement and to determine the depth of the void.

Trinh, Long Buu↗

Optical Levitation of Micro-Scale Particles in Air

Success has been achieved using a radiation pressure gradient to levitate microscale particles in air for as long as four hours. This work is performed as a precursor to the development of a vacuum based optical tweezers interrogation tool for nanotechnology research. It was decided to first proceed with solving the problem of achieving optical levitation of a micro-scale particle in air before trying the same in a vacuum environment. This successful optical levitation in air confirms the work of Ashkin and Dziedzic. Levitation of 10 and 13.8 microns diameter polystyrene spheres was achieved, as well as the levitation of 10 and 100 microns diameter glass spheres. Particles were raised and lowered. A modicum of success was achieved translating particles horizontally. Trapping of multiple particles in one laser beam has been photographed. Also, it has been observed that particles, that may be conglomerates or irregular in shape, can also be trapped by a focused laser beam. Levitated glass beads were photographed using laser light scattered from the beads. The fact that there is evidence of optical traps in air containing irregular and conglomerate particles provides hope that future tool particles need not be perfect spheres.

Wrbanek, Susan Y.↗

Stratospheric feedback from continued increases in tropospheric methane

Tropospheric concentrations of methane have increased steadily over the past ten years at an average rate of 16.5 ppbv per year, to a value in January 1988 of 1.69 ppmv. Measurements of CH sub 4 concentrations in air bubbles trapped in ice cores have shown concentrations of about 0.7 ppmv 200 years ago, with little further change for thousands of years before that. Interpolation earlier into this century suggests a concentration of about 1.1 to 1.2 ppmv in the 1940's. The only important pathway believed to be important for transfer of air from the troposphere to the stratosphere in through the tropical tropopause which is cold enough to reduce the mixing ratio of H sub 2 O in that air to about 3 ppmv. The only other major pathway for the delivery of H to the stratosphere is through the simultaneous injection of gaseous CH sub 4 in the same rising air. The formation of clouds in the stratosphere is dependent upon very low temperatures, and generally upon the amount of water vapor available. The possibility of a positive feedback exists, especially in well-oxidized methane air, that clouds are easier to form than earlier. This could mean enhancement of PSCs in both Antarctic and Arctic locations. Additional H sub 2 O in the stratosphere can also add to some of the greenhouse calculations.

Rowland, F. Sherwood↗

Simulation-driven design optimization of reaction injection molding (RIM) process for polydicyclopentadiene (pDCPD): Minimizing cycle time, defects, and warpage

Replacing metal components in trucks, trailers, and buses with lightweight polymer composites is challenging due to high temperatures and complex manufacturing. The Reaction Injection Molding (RIM) process using Dicyclopentadiene (DCPD) resin offers a solution by producing robust parts with excellent stiffness, impact strength, and resistance properties. Simulations are essential for optimizing this process, predicting defects, and improving quality. However, most commercial software is tailored for thermoplastics, requiring thermoset users to generate their own datasets. In this study, a material data card for DCPD was developed to perform RIM simulations. Design of Experiments (DOE) was used to identify key factors affecting filling, curing, and warpage, aiming to minimize cycle time and defects. The simulations explored varying injection gate parameters (size, location, number) and process conditions (mold/resin temperature, injection/curing pressure). Results showed that gate design significantly impacts filling behavior and defects. A single central gate provided balanced flow with fewer defects, while two corner gates led to more defects. Additionally, lower injection pressure increased filling time, while higher mold temperature accelerated curing but led to more warpage. In conclusion, this optimization framework aims to enhance DCPD part performance and promote sustainable manufacturing by reducing waste and energy consumption.

42 ENGINEERING↗

Mobile sampler for use in acquiring samples of terrestrial atmospheric gases

Samples of terrestrial atmospheric gasses from a free body of such gasses using a device characterized by a plurality of tubular bodies adapted to be mounted in side by side relation on a motorized highway vehicle in mutual parallelism with the axis of the normal path of travel for the vehicles. Each of the bodies is of a cylindrical configuration and has an axial opening at each of its opposite ends through which a linear flow path is defined. A pair of pivotally supported, spring-biased sealing caps is mounted adjacent to the ends of the body and continuously urged into a hermetic sealing relationship. A restraint for securing the caps against spring-urged pivotal displacement, includes a separable, normally tensioned line interconnecting the caps and an operable release mechanism for simultaneously releasing the caps for spring-urged displacement. A hot wire cutter is included for separating the line, whereby samples of air are trapped in the body as the caps are spring-driven to assume an hermetically sealed relation with the openings defined in each of the opposite ends of the body.

Tucker, C. E.↗