Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alpha counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis and Recommendation of Alpha-Beta Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) alpha-beta continuous air monitor (CAM) is used for real-time detection of “artificial” alpha-beta particulates from the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory—called the “PNNL OS3300 Alpha-Beta Monitoring Software”—that provides real-time estimates of alpha-beta air concentrations and integrated activities that are calculated from measured CAM counts. The OS3300 software has alarm setpoints that can be used to provide an early indication of larger releases, that if allowed to persist, could approach defined dose limits. This report performs a detailed review of historical and current alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios, meteorology, and adjustment factors used in estimating released stack activity. Based on the results, the alpha and beta air concentration alarm setpoints will remain 1.77 × 10 -8 µCi/ml and 3.47 × 10 -8 µCi/ml, respectively; and the alpha and beta integrated activity alarm setpoints will remain 70.22 µCi and 137.63 µCi, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned radiological work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are below defined and regulatory limits.

325RPL↗

Challenges and Practical Solutions for Conducting Structural MARSSIM Surveys in Elevated Radon Environments - 20413

The Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) [1] provides comprehensive guidance for the development and implementation of radiological surveys conducted to demonstrate compliance with a dose- or risk-based cleanup goal during final status survey. The MARSSIM methodology follows an integrated strategy combining direct measurements and sampling to assess uniform residual contamination, and scanning surveys to identify localized areas of elevated activity. Building surveys assessing residual surface contamination present unique challenges from reliance on field measurements that may be subject to less than ideal environmental conditions. Additionally, limited characterization and excessive conservatism incorporated into the conceptual site model may result in derived concentration guideline levels (DCGL) and, as a consequence of relatively inefficient field instrumentation, corresponding attributable count rates generally comparable to background. The presence of elevated ambient radon concentrations and associated progeny deposition both exacerbate these intrinsic survey challenges and introduce a series of technical, logistic, and administrative obstacles that can wreak havoc on the statistical legitimacy of each component of the MARSSIM process. Short-lived radon progeny including polonium-218, lead-214, bismuth-214, and polonium-214 produce excessive alpha and beta radiation that may decrease instrument sensitivity through an increase in background count rates, and, at worst, may result in incorrect survey unit failure through the simulation of residual surface activity. Aside from the obvious solution of exhaustive radon mitigation, the primary objectives are to distinguish between radon progeny deposition and actual surface activity, and collect sufficient defensible data. The following is a technical discussion of the consequences of performing building MARSSIM surveys in the presence of elevated ambient radon atmospheres, conceptual examples, and an overview of practical strategies to minimize the effects of radon interference while collecting sufficient defensible data to complete the survey. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Artificial neural network based isotopic analysis of airborne radioactivity measurement for radiological incident detection

Responders need tools to rapidly detect and identify airborne alpha radioactivity during consequence management scenarios. Traditional continuous air monitor systems used for this purpose compute the net counts in various energy windows to determine the presence of specified isotopes, such as 235U, 239Pu, and 241Am. These calculations rely on having a well-calibrated detector, which is challenging in low-background environments. Here an alternative approach of using artificial neural networks to classify alpha spectra is presented. Two network architectures, fully connected and convolutional networks, were trained to classify alpha spectra into four categories: background and background plus the three isotopes above. Sources were injected into measured background at various fractions of the derived response level (DRL) corresponding to early-phase Protective Action Guides. The convolutional network identifies all sources at 1% of the DRL with average probability of detection of 95% and false alarm probability of 1%. Further, the network identifies sources ranging between 0.25% and 1% of the DRL with higher than 80% probability of detection and lower than 7% false alarm probability. Most significantly, the network performance improves in low-count background conditions, increasing its minimum probability of detection to 93% and reducing the false alarm probabilities to lower than 0.25%. These results show that, once trained on datasets representing a range of detection scenarios, artificial neural networks can accurately identify alpha isotopes of interest without the need for detector calibration.

Woldegiorgis, Surafel F.↗

Conceptual design of DIII-D experiments to diagnose the lifetime of spin polarized fuel

Abstract In magnetic fusion experiments, the cross sections for the D-T and D- 3 He fusion reactions are increased by as much as 50% if the fuel remains spin polarized parallel to the magnetic field. The goal of this study is to assess the feasibility of lifetime measurements of spin polarization, in magnetic fusion relevant conditions, on the DIII-D tokamak using relative changes in charged fusion product (CFP) loss measurements that depend upon the differential fusion cross section d σ /dΩ. Relative measurements that capture changes in the escaping CFP pitch, poloidal, and energy distributions are studied in two realistic TRANSP calculated plasma scenarios: (a) vector-polarized 3 He and D pellets are injected into a hot hydrogen plasma to produce thermonuclear reactions, and (b) a tensor-polarized deuterium pellet is injected into an L-mode hydrogen background plasma that includes unpolarized 3 He neutral beam injection. Ideal CFP signals in both scenarios show substantial pitch sensitivity to polarization for 14.7 MeV proton detection at a poloidal angle of − 56 ∘ (on the outer wall in the ion ∇ B direction), and strong sensitivity to polarization for 3.6 MeV alpha flux detection by an array of poloidal detectors. Energy-resolved measurements of 14.7 MeV protons are also sensitive to the degree of polarization for the − 56 ∘ port in the beam-plasma scenario. A realistic assessment of CFP signals in the thermonuclear scenario show count rates in the range of 2 × 10 4 cps for pitch-resolved proton detection and 2 × 10 5 cps for alpha flux measurements. Reduced chi-squared χ r 2 calculations show polarization lifetime measurements are feasible for either proton or alpha detection of both enhanced or suppressed polarization for the thermonuclear scenario. Measurements of gamma rays produced in the weak D + 3 He → γ + 5 Li branch complement the CFP measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baltic Sea coastal sediment-bound eukaryotes have increased year-round activities under predicted climate change related warming

Climate change related warming is a serious environmental problem attributed to anthropogenic activities, causing ocean water temperatures to rise in the coastal marine ecosystem since the last century. This particularly affects benthic microbial communities, which are crucial for biogeochemical cycles. While bacterial communities have received considerable scientific attention, the benthic eukaryotic community response to climate change remains relatively overlooked. In this study, sediments were sampled from a heated (average 5°C increase over the whole year for over 50 years) and a control (contemporary conditions) Baltic Sea bay during four different seasons across a year. RNA transcript counts were then used to investigate eukaryotic community changes under long-term warming. The composition of active species in the heated and control bay sediment eukaryotic communities differed, which was mainly attributed to salinity and temperature. The family level RNA transcript alpha diversity in the heated bay was higher during May but lower in November, compared with the control bay, suggesting altered seasonal activity patterns and dynamics. In addition, structures of the active eukaryotic communities varied between the two bays during the same season. Hence, this study revealed that long-term warming can change seasonality in eukaryotic diversity patterns. Relative abundances and transcript expression comparisons between bays suggested that some taxa that now have lower mRNA transcripts numbers could be favored by future warming. Furthermore, long-term warming can lead to a more active metabolism in these communities throughout the year, such as higher transcript numbers associated with diatom energy production and protein synthesis in the heated bay during winter. In all, these data can help predict how future global warming will affect the ecology and metabolism of eukaryotic community in coastal sediments.

59 BASIC BIOLOGICAL SCIENCES↗

Ratio of 1,275 and 186 keV Gamma Ray Count Rates for Age Determination of Material in UF 6 Cylinders

In this work, a method for using ratios of passive gamma ray measurements to determine the time since the filling of UF 6 cylinders was explored. This method uses the 186 keV gamma ray emitted by 235 U and the 1,275 keV gamma ray that results from interactions of alpha particles in fluorine. Studies were made using MCNP models of both 30B cylinders and smaller 5A cylinders. Results indicate that for enrichments at or above that of natural uranium, this approach may provide a method for determining age up to 10 years or identifying whether the age is greater than 10 years, even if the uranium enrichment is unknown. The calculated results show the same behavior as the results of a recent measurement campaign, indicating the possibility of using this method for real-world cylinders.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

$\mathrm{α}$ decay of the longest-lived Cm isotope: $^{247}_{96}\mathrm{Cm}$

We report alpha decay of 247 Cm was studied fifty years ago using a 1.6 Bq source containing 99.4 % 247 Cm and levels in 243 Pu were deduced. Using the same source, γ-ray spectra were measured with a more efficient Ge detector. A γ-ray spectrum was also measured in coincidence with α particles for a period of two months and has 80 times more counts than the previously published spectrum. Gamma-ray energies were determined with higher precision and four new γ rays were identified. A new high-energy γ ray of 564.5 keV was observed, which is interpreted as a transition between a level at 564.5 keV and the ground state of 243 Pu. The 564.5-keV level has been tentatively assigned to the 7/2 - [743] Nilsson state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

REDC Process Instrumentation Modernization Project

Critical electronics used for isotopes production have become outdated and difficult to manufacture. In particular the alpha-particle and neutron detection electronics (commonly referred to as Q2809A-9 and -11) which are used to monitor effluent activity in ORNL Building 7920 were designed and deployed in 1966-67. These electronics are still used but some parts are no longer available for purchase. In addition, the printed circuit boards used in the Count Rate Monitor (CRM) module have no fabrication files or quality assurance documentation. In light of this, a project to modernize the modules for ability to manufacture with modern parts was undertaken. Both the preamplifier and CRM were modernized with new printed circuit boards and parts which are current catalog parts. In addition, QA documentation was generated which allows the manufacturer to assure proper operation prior to delivery.

42 ENGINEERING↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plant Hosts Modify Belowground Microbial Community Response to Extreme Drought

Drought stress negatively impacts microbial activity, yet the magnitude of stress responses is likely dependent on a diversity of belowground interactions. Populus trichocarpa individuals and no-plant bulk soils were exposed to extended drought (~0.03% gravimetric water content [GWC] after 12 days), rewet, and a 12-day “recovery” period to determine the effects of plant presence in mediating soil microbiome stability to water stress. Plant metabolomic analyses indicated that drought exposure increased host investment in C and N metabolic pathways (amino acids, fatty acids, phenolic glycosides) regardless of recovery. Several metabolites positively correlated with root-associated microbial alpha-diversity, but not those of soil communities. Soil bacterial community composition shifted with P. trichocarpa presence and with drought relative to irrigated controls, whereas soil fungal composition shifted only with plant presence. However, root fungal communities strongly shifted with drought, whereas root bacterial communities changed to a lesser degree. The proportion of bacterial water-stress opportunistic operational taxonomic units (OTUs) (enriched counts in drought) was high (~11%) at the end of drying phases and maintained after rewet and recovery phases in bulk soils, but it declined over time in soils with plants present. For root fungi, opportunistic OTUs were high at the end of recovery in drought treatments (~17% abundance), although relatively not responsive in soils, particularly planted soils (<0.5% abundance for sensitive or opportunistic). These data indicate that plants modulate soil and root-associated microbial drought responses via tight plant-microbe linkages during extreme drought scenarios, but trajectories after extreme drought vary with plant habitat and microbial functional groups.

59 BASIC BIOLOGICAL SCIENCES↗

Use of Compton suppression gamma ray spectrometry to determine 239 Pu

We report 239 Pu has been characterized by gamma-ray spectroscopy for a level higher than the usual environmental ones typically needing alpha spectrometry, ICP-MS or TIMS. The higher activities typically have applications in reprocessing, safeguards verification, and nuclear forensics. For activities of hundreds of Bq/g, it is possible to use gamma ray spectrometry for 239 Pu characterization. A soil reference standard of 185 Bq/g (75 ng/g) was measured on a 79% efficient HPGe with a digital Compton suppression system. The ratios of the counting statistics for suppressed and unsuppressed uncertainties for various 239 Pu photopeaks were determined. The effects of self-attenuation on the low energy gamma rays were evaluated, and it was determined that Compton suppression was an effective characterization method of 239 Pu after accounting for self-attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Project 57 Air Monitoring Report: (Jan 1 - Dec 31 2018)

During the late 1950s, the Atomic Energy Commission (AEC) (now the U.S. Department of Energy [DOE]) conducted a series of safety experiments to determine if a nuclear device subjected to a large conventional explosives detonation would result in a nuclear yield. The AEC obtained temporary use of a large portion of western Emigrant Valley from the U.S. Department of Defense (DOD) for one of these experiments: Project 57. Following the Project 57 safety experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DOD. Emigrant Valley is part of the Nevada Test and Training Range (NTTR). For safety and security reasons, access to the NTTR is controlled using both physical (i.e., fences) and administrative (e.g., signs and postings) controls. Therefore, the public cannot access the Project 57 site and there are no known human receptors that routinely access the site. Project 57 was detonated on April 24, 1957, in Emigrant Valley approximately 13 mi (21 km) northeast of the north end of Yucca Flat. This test was undertaken to develop: (1) a means of estimating immediate distribution and long-term redistribution of plutonium dispersed during a nonnuclear detonation; (2) biomedical evaluation techniques for use in likely plutonium-laden environments; (3) methods of decontaminating ground areas, pavements, and building materials; and (4) alpha survey instruments and field monitoring procedures to promptly estimate contaminant deposition. Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the ground surface. Various radiological surveys have been performed in the area since Project 57 was conducted. The AEC delineated the area containing radioactive material based on radioactivity surveys performed shortly after the test was conducted. A designated Contamination Area (CA), marked by a fence, was established later. The distribution of americium-241 (Am-241) in the area was determined again in a 1997 flyover, which showed Am-241 ranging from as much as 70,000 counts per second (cps) at ground zero to background (<70 cps). This survey also documented Am-241 radioactivity on the ground surface beyond the east side CA fence at levels of up to 150 cps. In 2007, the DOE expanded the CA by posting “Contamination Area” signs 200 ft to 400 ft (60 m to 120 m) beyond the original fence, which formed a new CA boundary.

54 ENVIRONMENTAL SCIENCES↗

Mapathons versus automated feature extraction: a comparative analysis for strengthening immunization microplanning

Background: Social instability and logistical factors like the displacement of vulnerable populations, the difficulty of accessing these populations, and the lack of geographic information for hard-to-reach areas continue to serve as barriers to global essential immunizations (EI). Microplanning, a population-based, healthcare intervention planning method has begun to leverage geographic information system (GIS) technology and geospatial methods to improve the remote identification and mapping of vulnerable populations to ensure inclusion in outreach and immunization services, when feasible. We compare two methods of accomplishing a remote inventory of building locations to assess their accuracy and similarity to currently employed microplan line-lists in the study area. Methods: The outputs of a crowd-sourced digitization effort, or mapathon, were compared to those of a machine-learning algorithm for digitization, referred to as automatic feature extraction (AFE). The following accuracy assessments were employed to determine the performance of each feature generation method: (1) an agreement analysis of the two methods assessed the occurrence of matches across the two outputs, where agreements were labeled as “befriended” and disagreements as “lonely”; (2) true and false positive percentages of each method were calculated in comparison to satellite imagery; (3) counts of features generated from both the mapathon and AFE were statistically compared to the number of features listed in the microplan line-list for the study area; and (4) population estimates for both feature generation method were determined for every structure identified assuming a total of three households per compound, with each household averaging two adults and 5 children. Results: The mapathon and AFE outputs detected 92,713 and 53,150 features, respectively. A higher proportion (30%) of AFE features were befriended compared with befriended mapathon points (28%). The AFE had a higher true positive rate (90.5%) of identifying structures than the mapathon (84.5%). The difference in the average number of features identified per area between the microplan and mapathon points was larger (t = 3.56) than the microplan and AFE (t = -2.09) (alpha = 0.05). Conclusions: Our findings indicate AFE outputs had higher agreement (i.e., befriended), slightly higher likelihood of correctly identifying a structure, and were more similar to the local microplan line-lists than the mapathon outputs. These findings suggest AFE may be more accurate for identifying structures in high-resolution satellite imagery than mapathons. However, they both had their advantages and the ideal method would utilize both methods in tandem.

59 BASIC BIOLOGICAL SCIENCES↗