Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alternating minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Subspace-Aware Index Codes

In this paper, we generalize the well-known index coding problem to exploit the structure in the source-data to improve system throughput. In many applications (e.g., multimedia), the data to be transmitted may lie (or can be well approximated) in a low-dimensional subspace. We exploit this low-dimensional structure of the data using an algebraic framework to solve the index coding problem (referred to as subspace-aware index coding) as opposed to the traditional index coding problem which is subspace-unaware. Also, we propose an efficient algorithm based on the alternating minimization approach to obtain near optimal index codes for both subspace-aware and -unaware cases. In conclusion, our simulations indicate that under certain conditions, a significant throughput gain (about 90%) can be achieved by subspace-aware index codes over conventional subspace-unaware index codes.

97 MATHEMATICS AND COMPUTING↗

Information-theoretic discrepancy based iterative reconstructions (IDIR) for polychromatic x-ray tomography

Purpose: X-ray photons generated from a typical x-ray source for clinical applications exhibit a broad range of wavelengths, and the interactions between individual particles and biological substances depend on particles' energy levels. Most existing reconstruction methods for transmission tomography, however, neglect this polychromatic nature of measurements and rely on the monochromatic approximation. In this study, we developed a new family of iterative methods that incorporates the exact polychromatic model into tomographic image recovery, which improves the accuracy and quality of reconstruction.Methods: The generalized information-theoretic discrepancy (GID) was employed as a new metric for quantifying the distance between the measured and synthetic data. By using special features of the GID, the objective function for polychromatic reconstruction which contains a double integral over the wavelength and the trajectory of incident x-rays was simplified to a paraboloidal form without using the monochromatic approximation. More specifically, the original GID was replaced with a surrogate function with two auxiliary, energy-dependent variables. Subsequently, the alternating minimization technique was applied to solve the double minimization problem. Based on the optimization transfer principle, the objective function was further simplified to the paraboloidal equation, which leads to a closed-form update formula. Numerical experiments on the beam-hardening correction and material-selective reconstruction were conducted to compare and assess the performance of conventional methods and the proposed algorithms.Results: The authors found that the GID determines the distance between its two arguments in a flexible manner. In this study, three groups of GIDs with distinct data representations were considered. The authors demonstrated that one type of GIDs that comprises “raw” data can be viewed as an extension of existing statistical reconstructions; under a particular condition, the GID is equivalent to the Poisson log-likelihood function. The newly proposed GIDs of the other two categories consist of log-transformed measurements, which have the advantage of imposing linearized penalties over multiple discrepancies. For all proposed variants of the GID, the aforementioned strategy was used to obtain a closed-form update equation. Even though it is based on the exact polychromatic model, the derived algorithm bears a structural resemblance to conventional methods based on the monochromatic approximation. The authors named the proposed approach as information-theoretic discrepancy based iterative reconstructions (IDIR). In numerical experiments, IDIR with raw data converged faster than previously known statistical reconstruction methods. IDIR with log-transformed data exhibited superior reconstruction quality and faster convergence speed compared with conventional methods and their variants.Conclusions: The authors' new framework for tomographic reconstruction allows iterative inversion of the polychromatic data model. The primary departure from the traditional iterative reconstruction was the employment of the GID as a new metric for quantifying the inconsistency between the measured and synthetic data. The proposed methods outperformed not only conventional methods based on the monochromatic approximation but also those based on the polychromatic model. The authors have observed that the GID is a very flexible means to design an objective function for iterative reconstructions. Hence, the authors expect that the proposed IDIR framework will also be applicable to other challenging tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-FG-BRB-03: Basis Vector Model Based Method for Proton Stopping Power Estimation From Experimental Dual Energy CT Data

Purpose: This work aims at reducing the uncertainty in proton stopping power (SP) estimation by a novel combination of a linear, separable basis vector model (BVM) for stopping power calculation (Med Phys 43:600) and a statistical, model-based dual-energy CT (DECT) image reconstruction algorithm (TMI 35:685). The method was applied to experimental data. Methods: BVM assumes the photon attenuation coefficients, electron densities, and mean excitation energies (I-values) of unknown materials can be approximated by a combination of the corresponding quantities of two reference materials. The DECT projection data for a phantom with 5 different known materials was collected on a Philips Brilliance scanner using two scans at 90 kVp and 140 kVp. The line integral alternating minimization (LIAM) algorithm was used to recover the two BVM coefficient images using the measured source spectra. The proton stopping powers are then estimated from the Bethe-Bloch equation using electron densities and I-values derived from the BVM coefficients. The proton stopping powers and proton ranges for the phantom materials estimated via our BVM based DECT method are compared to ICRU reference values and a post-processing DECT analysis (Yang PMB 55:1343) applied to vendorreconstructed images using the Torikoshi parametric fit model (tPFM). Results: For the phantom materials, the average stopping power estimations for 175 MeV protons derived from our method are within 1% of the ICRU reference values (except for Teflon with a 1.48% error), with an average standard deviation of 0.46% over pixels. The resultant proton ranges agree with the reference values within 2 mm. Conclusion: Our principled DECT iterative reconstruction algorithm, incorporating optimal beam hardening and scatter corrections, in conjunction with a simple linear BVM model, achieves more accurate and robust proton stopping power maps than the post-processing, nonlinear tPFM based DECT analysis applied to conventional reconstructions of low and high energy scans. Funding Support: NIH R01CA 75371; NCI grant R01 CA 149305.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP3-01: Simultaneous PET Restoration and PET/CT Co-Segmentation Using a Variational Method

Purpose: PET images are usually blurred due to the finite spatial resolution, while CT images suffer from low contrast. Segment a tumor from either a single PET or CT image is thus challenging. To make full use of the complementary information between PET and CT, we propose a novel variational method for simultaneous PET image restoration and PET/CT images co-segmentation. Methods: The proposed model was constructed based on the Γ-convergence approximation of Mumford-Shah (MS) segmentation model for PET/CT co-segmentation. Moreover, a PET de-blur process was integrated into the MS model to improve the segmentation accuracy. An interaction edge constraint term over the two modalities were specially designed to share the complementary information. The energy functional was iteratively optimized using an alternate minimization (AM) algorithm. The performance of the proposed method was validated on ten lung cancer cases and five esophageal cancer cases. The ground truth were manually delineated by an experienced radiation oncologist using the complementary visual features of PET and CT. The segmentation accuracy was evaluated by Dice similarity index (DSI) and volume error (VE). Results: The proposed method achieved an expected restoration result for PET image and satisfactory segmentation results for both PET and CT images. For lung cancer dataset, the average DSI (0.72) increased by 0.17 and 0.40 than single PET and CT segmentation. For esophageal cancer dataset, the average DSI (0.85) increased by 0.07 and 0.43 than single PET and CT segmentation. Conclusion: The proposed method took full advantage of the complementary information from PET and CT images. This work was supported in part by the National Cancer Institute Grants R01CA172638. Shan Tan and Laquan Li were supported in part by the National Natural Science Foundation of China, under Grant Nos. 60971112 and 61375018.

60 APPLIED LIFE SCIENCES↗

Elastic-Waveform Inversion with Compressive Sensing for Sparse Seismic Data

Accurate velocity models of compressional- and shear-waves are essential for geothermal reservoir characterization and microseismic imaging. Elastic-waveform inversion of multi-component seismic data can provide high-resolution inversion results of subsurface geophysical properties. However, the method requires seismic data acquired using dense source and receiver arrays. In practice, seismic sources and/or geophones are often sparsely distributed on the surface and/or in a borehole, such as 3D vertical seismic profiling (VSP) surveys. We develop a novel elastic-waveform inversion method with compressive sensing for inversion of sparse seismic data. We employ an alternating-minimization algorithm to solve the optimization problem of our new waveform inversion method. We validate our new method using synthetic VSP data for a geophysical model built using geologic features found at the Raft River enhanced-geothermal-system (EGS) field. We apply our method to synthetic VSP data with a sparse source array and compare the results with those obtained with a dense source array. Our numerical results demonstrate that the velocity models produced with our new method using a sparse source array are almost as accurate as those obtained using a dense source array.

58 GEOSCIENCES↗

High brightness--multiple beamlets source for patterned X-ray production

Techniques for controllably directing beamlets to a target substrate are disclosed. The beamlets may be either positive ions or electrons. It has been shown that beamlets may be produced with a diameter of 1 .mu.m, with inter-aperture spacings of 12 .mu.m. An array of such beamlets, may be used for maskless lithography. By step-wise movement of the beamlets relative to the target substrate, individual devices may be directly e-beam written. Ion beams may be directly written as well. Due to the high brightness of the beamlets from extraction from a multicusp source, exposure times for lithographic exposure are thought to be minimized. Alternatively, the beamlets may be electrons striking a high Z material for X-ray production, thereafter collimated to provide patterned X-ray exposures such as those used in CAT scans. Such a device may be used for remote detection of explosives.

47 OTHER INSTRUMENTATION↗

Acoustic- and elastic-waveform inversion with total generalized p-variation regularization

Geophysical models usually contain both sharp interfaces and smooth variations, and it is difficult to accurately account for both of these two types of medium parameter variations using conventional full-waveform inversion methods. We develop a novel full-waveform inversion method for acoustic and elastic waves using a total generalized p-variation regularization scheme to address these challenging problems. We decompose the full-waveform inversion into two subproblems and solve these two minimization subproblems using an alternating-direction minimization strategy. One significant advantage of the total generalized p-variation regularization scheme is that it can simultaneously reconstruct sharp interfaces and smooth background variations of geophysical parameters. Such capability can also effectively suppress the noises in source-encoded inversion and sparse-data inversion, or inversion of noisy data. We demonstrate the advantages of our full-waveform inversion method using a checkerboard model, a modified elastic SEG/EAGE overthrust model, and a land field seismic data set. Our conclusions of synthetic and field seismic data demonstrate that our method reconstructs both smooth background variations and sharp interfaces of subsurface geophysical properties accurately, and provides a useful tool for accurate and reliable inversion of field seismic data.

58 GEOSCIENCES↗

Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs

Purpose: Metal artifact reduction (MAR) is a major problem and a challenging issue in x-ray computed tomography (CT) examinations. Iterative reconstruction from sinograms unaffected by metals shows promising potential in detail recovery. This reconstruction has been the subject of much research in recent years. However, conventional iterative reconstruction methods easily introduce new artifacts around metal implants because of incomplete data reconstruction and inconsistencies in practical data acquisition. Hence, this work aims at developing a method to suppress newly introduced artifacts and improve the image quality around metal implants for the iterative MAR scheme. Methods: The proposed method consists of two steps based on the general iterative MAR framework. An uncorrected image is initially reconstructed, and the corresponding metal trace is obtained. The iterative reconstruction method is then used to reconstruct images from the unaffected sinogram. In the reconstruction step of this work, an iterative strategy utilizing unmatched projector/backprojector pairs is used. A ramp filter is introduced into the back-projection procedure to restrain the inconsistency components in low frequencies and generate more reliable images of the regions around metals. Furthermore, a constrained total variation (TV) minimization model is also incorporated to enhance efficiency. The proposed strategy is implemented based on an iterative FBP and an alternating direction minimization (ADM) scheme, respectively. The developed algorithms are referred to as “iFBP-TV” and “TV-FADM,” respectively. Two projection-completion-based MAR methods and three iterative MAR methods are performed simultaneously for comparison. Results: The proposed method performs reasonably on both simulation and real CT-scanned datasets. This approach could reduce streak metal artifacts effectively and avoid the mentioned effects in the vicinity of the metals. The improvements are evaluated by inspecting regions of interest and by comparing the root-mean-square errors, normalized mean absolute distance, and universal quality index metrics of the images. Both iFBP-TV and TV-FADM methods outperform other counterparts in all cases. Unlike the conventional iterative methods, the proposed strategy utilizing unmatched projector/backprojector pairs shows excellent performance in detail preservation and prevention of the introduction of new artifacts. Conclusions: Qualitative and quantitative evaluations of experimental results indicate that the developed method outperforms classical MAR algorithms in suppressing streak artifacts and preserving the edge structural information of the object. In particular, structures lying close to metals can be gradually recovered because of the reduction of artifacts caused by inconsistency effects.

60 APPLIED LIFE SCIENCES↗

Energy of injection-induced seismicity predicted from in-situ experiments

The ability to predict the magnitude of an earthquake caused by deep fluid injections is an important factor for assessing the safety of the reservoir storage and the seismic hazard. Here, we propose a new approach to evaluate the seismic energy released during fluid injection by integrating injection parameters, induced aseismic deformation, and the distance of earthquake sources from injection. We use data from ten injection experiments performed at a decameter scale into fault zones in limestone and shale formations. We observe that the seismic energy and the hydraulic energy similarly depend on the injected fluid volume (V), as they both scale as V 3/2 . They show, however, a large discrepancy, partly related to a large aseismic deformation. Therefore, to accurately predict the released seismic energy, aseismic deformation should be considered in the budget through the residual deformation measured at the injection. Alternatively, the minimal hypocentral distance from injection points and the critical fluid pressure for fault reactivation can be used for a better prediction of the seismic moment in the total compilation of earthquakes observed during these experiments. Complementary to the prediction based only on the injected fluid volume, our approach opens the possibility of using alternative monitoring parameters to improve traffic-light protocols for induced earthquakes and the regulation of operational injection activities.

58 GEOSCIENCES↗

Advanced Analysis of Hydraulic Fracture Propagation and Efficiency Using Natural Gas as an Alternative to Water

Over the past years, new technologies have been presented as an alternative to minimize or eliminate the use of water in hydraulic fracturing for unconventional reservoirs, improve resource recovery, cost management and reduce environmental impact. As part of these technologies, energized fluids have been developed to mitigate the environmental impact caused by the application of large volumes of water during hydraulic fracturing. When a fracture is energized, the amount of water pumped during the fracturing process is reduced or eliminated by adding a gas component to the fracturing fluid. The less water that is pumped, the less damage it will create. A new technology called “Energized Natural Gas (ENG)” has recently been proposed for effective hydraulic fracturing in unconventional reservoirs. The ENG process shows that it may be a viable solution for the oil and gas industry. Due to the complexity of multiphase fluid behavior and fracture mechanics, further research and documentation is required to effectively apply gas and gas-water mixtures as a treatment fluid. The objective of this research is to further develop and demonstrate the use of natural gas as an optimum fracturing fluid for tight shale gas formations. GeoMechanics Technologies proposes to complete advanced analyses of hydraulic fracture propagation efficiency using natural gas as an alternative to water. A comprehensive review on the transport properties of gas and water mixtures was performed to investigate the rheology differences of conventionally-used fresh water and the natural gas mixture. This research helped to determine how rheology affects hydraulic fracturing. Then we developed a coupled 3D geomechanical model and fluid flow model to simulate hydraulic fracturing using various mixtures of natural gas and water to determine an effective combination. Gas production was also simulated to further test the effectiveness of the induced fracture. Finally, the technical and economic feasibility of this novel technology was considered and documented.

02 PETROLEUM↗

Always Contact a Vascular Interventional Specialist Before Amputating a Patient with Critical Limb Ischemia

Patients with severe critical limb ischemia (CLI) due to long tibial artery occlusions are often poor candidates for surgical revascularization and frequently end up with a lower limb amputation. Subintimal angioplasty (SA) offers a minimally invasive alternative for limb salvage in this severely compromised patient population. The objective of this study was to evaluate the results of SA in patients with CLI caused by long tibial occlusions who have no surgical options for revascularization and are facing amputation. We retrospectively reviewed all consecutive patients with CLI due to long tibial occlusions who were scheduled for amputation because they had no surgical options for revascularization and who were treated by SA. A total of 26 procedures in 25 patients (14 males; mean age, 70 {+-} 15 [SD] years) were evaluated. Technical success rate was 88% (23/26). There were four complications, which were treated conservatively. Finally, in 10 of 26 limbs, no amputation was needed. A major amputation was needed in 10 limbs (7 below-knee amputations and 3 above-knee amputations). Half of the major amputations took place within 3 months after the procedure. Cumulative freedom of major amputation after 12 months was 59% (SE = 11%). In six limbs, amputation was limited to a minor amputation. Seven patients (28%) died during follow-up. In conclusion, SA of the tibial arteries seem to be a valuable treatment option to prevent major amputation in patients with CLI who are facing amputation due to lack of surgical options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bare Metal Stenting for Endovascular Exclusion of Aortic Arch Thrombi

BackgroundAortic thrombi in the ascending aorta or aortic arch are rare but are associated with a relevant risk of major stroke or distal embolization. Although stent grafting is commonly used as a treatment option in the descending aorta, only a few case reports discuss stenting of the aortic arch for the treatment of a thrombus. The use of bare metal stents in this setting has not yet been described.MethodsWe report two cases of ascending and aortic arch thrombus that were treated by covering the thrombus with an uncovered stent. Both procedures were performed under local anesthesia via a femoral approach. A femoral cutdown was used in one case, and a total percutaneous insertion was possible in the second case.ResultsBoth procedures were successfully performed without any periprocedural complications. Postoperative recovery was uneventful. In both cases, no late complications or recurrent embolization occurred at midterm follow-up, and control CT angiography at 1 respectively 10 months revealed no stent migration, freely perfused supra-aortic branches, and no thrombus recurrence.ConclusionTreating symptomatic thrombi in the ascending aorta or aortic arch with a bare metal stent is feasible. This technique could constitute a minimally invasive alternative to a surgical intervention or complex endovascular therapy with fenestrated or branched stent grafts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Treatment for Benign Prostatic Hyperplasia: Economic Evaluation from a Standardized Hospital Case Costing System

Purpose: Minimally invasive alternatives to transurethral resection of the prostate (TURP) such as prostate arterial embolization (PAE) and photoselective vaporization of the prostate (PVP) are being explored as adjuncts in the care of patients with benign prostatic hyperplasia. However, there are conflicting reports of the costs of these procedures. The purpose of this study was to compare the direct and indirect hospital costs of TURP, PAE and PVP. Materials and Methods: A chart review was performed in patients who underwent TURP, PVP and PAE from April 2015 to March 2017. All hospital costs were collected in accordance with the Ontario Case Costing Initiative, a standardized medical case costing system. Costs were characterized as direct or indirect and fixed or variable. Probabilistic sensitivity analysis was conducted to study cost uncertainty. Results: During the study period, a total of 209 men underwent TURP, 28 PVP and 21 PAE. Mean age (years) was as follows: TURP 71.43; PVP 73.66; PAE 70.77 (p = 0.366). Mean length of stay (days) was as follows: TURP 1.63; PVP 1.55; PAE 1 (p = 0.076). Total costs of the PAE group ($3829, SD $1582) were less than both PVP ($5719, SD $1515) and TURP groups ($5034, SD $1997, p < 0.001). There was no significant difference in direct costs between the groups. Monte Carlo simulation demonstrated that PAE was the least costly alternative majority of the time. Conclusions: The total hospital costs of PAE at our institution are significantly lower than those of PVP and TURP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial (Chemo-)Embolization and Lipiodolization for Hepatic Haemangioma

Background: Transarterial (chemo-)embolization/lipiodolization (TAE/TAL) might be an attractive minimally invasive alternative to surgery in the treatment of symptomatic hepatic haemangioma. This review assesses the efficacy and safety of TAE/TAL as primary treatment for symptomatic hepatic haemangioma. Methods: A systematic search of the literature was performed by two reviewers following the PRISMA guidelines. Cohort studies and case reports were identified; outcomes of cohort studies were reported. The primary efficacy outcome was tumour size before and after TAE/TAL. Improvement of symptoms and quality of life (QoL) were secondary outcomes; the primary safety outcome was complications. The Downs and Black statement was used for quality assessment. Results: Eighteen cohort studies were identified, including 1284 patients. TAE/TAL led to a decrease in tumour size in 1100/1223 (89.9%) patients and to improvement or disappearance of symptoms in 1080/1096 (98.5%) patients. A significant decrease in tumour size from 9.79 ± 0.79 cm to 4.00 ± 1.36 cm (p < 0.001) was shown. Grade 3 complications occurred in 37/1284 (2.9%) patients. Surgical treatment was necessary in 35/1284 (2.7%) of patients. Conclusion: TAE/TAL appears to be a promising and safe treatment to decrease tumour size of hepatic haemangioma. The technique might also provide partial relief of symptoms, although no randomized clinical trials or prospective studies using validated QoL questionnaires are available. TAE/TAL may be considered as a viable alternative to resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially dependent regularization parameter selection for total generalized variation-based image denoising

We propose a novel image denoising model based on the total generalized variation (TGV) regularization. In the model, a spatially dependent regularization parameter is utilized to adaptively fit the local image features, resulting in further exploitation of the denoising potential of the TGV regularization. The proposed model is formulated under a joint optimization framework, by which the estimations of the restored image and the regularization parameter are achieved simultaneously. Furthermore, the model is general purpose that can handle various types of noise occurring in image processing. An alternating minimization-based numerical scheme is especially developed, which leads to an efficient algorithmic solution to the nonconvex optimization problem. Numerical experiments are reported to illustrate the effectiveness of our model in terms of both peak signal-to-noise ratio and visual perception.

97 MATHEMATICS AND COMPUTING↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

An Online Plug-and-Play Algorithm for Regularized Image Reconstruction

Plug-and-play priors (PnP) is a powerful framework for regularizing imaging inverse problems by using advanced denoisers within an iterative algorithm. Recent experimental evidence suggests that PnP algorithms achieve state-of-the-art performance in a range of imaging applications. Here, we introduce a new online PnP algorithm based on the proximal gradient method (PGM). The proposed algorithm uses only a subset of measurements at every iteration, which makes it scalable to very large datasets. We present a new theoretical convergence analysis, for both batch and online variants of PnP-PGM, for denoisers that do not necessarily correspond to proximal operators. We also present simulations illustrating the applicability of the algorithm to image reconstruction in diffraction tomography. Finally, the results in this paper have the potential to expand the applicability of the PnP framework to very large datasets.

97 MATHEMATICS AND COMPUTING↗