At least 37 records · Page 2

Enhanced Depolarized Electro-Membrane System (EDEMS) for Direct Capture of Carbon Dioxide from Ambient Air (Final Report)

The goal of this final project report is to summarize the work conducted on project DE-FE0031962. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed an intensified process to capture CO2 from ambient conditions (400 ppm CO2). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO2 while regenerating the solvent. The technology employs only two primary units (regenerator and absorber/contactor) while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. When depolarization is employed, the operating voltage is reduced by more than 1 V. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The project results verified that UK CAER’s integrated approach addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions, including (1) low gas-side pressure-drop facile CO2 capture via a membrane contactor with in-situ generated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO2 concentration and hydrogen production, and (3) depolarization using cathode-produced hydrogen to reduce energy requirement. The EH&S Assessment of the process did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK CAER’s carbon capture and solvent regeneration system at a larger scale.

20 FOSSIL-FUELED POWER PLANTS↗

A numerical evaluation of the ambient air temperature in the Electron-Ion Collider tunnel

The Electron-Ion Collider (EIC) is a next-generation collider-accelerator that may require consistent operating temperature conditions for the beams within the accelerator tunnels to maintain stable operation. Variations in ambient temperature within the tunnel can cause thermal expansion of beampipe and component supports and can negatively affect the tunnel equipment, impacting the stability of the beamline. Modifications will be made to the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL) to create the EIC, which necessitates a temperature model that addresses these modifications. To approach this problem, the consistency of temperature changes in different tunnel sections was first evaluated by plotting RHIC tunnel temperature data at various times of the day and year. From this data, a tunnel section was selected and a 2D temperature model was created for RHIC, EIC, and EIC with added cooling configurations. Soil temperature data was analyzed to determine the maximum, average, and mode soil temperatures, which were used as boundary conditions in different temperature scenarios. Computational fluid dynamics modeling was used to create 2D temperature profiles for the configurations. From this model, the predicted temperatures indicate that further analysis is required to validate the boundary conditions and benchmark the current conditions to allow the prediction of the tunnel ambient conditions at EIC. This research can be used as a preliminary model to create an EIC tunnel cooling system that will increase the operational stability of the EIC. As a result of my work this summer, I have become familiar with computational fluid dynamics, including creating fluid dynamic simulations using ANSYS Fluent and related software. I have also learned about the project process required for planning large-scale engineering projects.

43 PARTICLE ACCELERATORS↗

Aging studies on chemical vapor deposition and mechanically exfoliated molybdenum disulfide flakes heated in ambient air

The structural integrity of atomically thin two-dimensional molybdenum disulfide (MoS 2 ) is crucial for high-temperature applications, including nanoelectronics and optoelectronics. This study explores the structural stability and electrical performance, under extended thermal exposure in air, of MoS 2 flakes synthesized via chemical vapor deposition (CVD) and mechanical exfoliation. The MoS 2 flakes, both CVD-grown and mechanically exfoliated, were subjected to heating at 200 °C with a relative humidity of 60(±5)% for a prolonged period and investigated with atomic force microscopy and Raman spectroscopy. This study shows that CVD-grown flakes developed noticeable cracks after prolonged heating, whereas mechanically exfoliated flakes mostly retained their structural integrity. Also, both types of flakes showed a decrease in layer thickness and lateral size over time, with mechanically exfoliated flakes exhibiting a comparatively smaller reduction in substrate coverage area. In addition, MoS 2 -based two-terminal devices were subjected to heating at 150 °C for approximately 1100 h, and their electrical characterization revealed a steady rise in current during constant voltage (5 V) conditions. This study enhances our understanding of MoS 2 stability and provides guidance for improving the reliability of MoS 2 -based devices in high-temperature electronic applications.

2D materials↗

Tussock tundra surface temperatures, ambient air and incoming photosynthetically active radiation measured at the NGEE Arctic Council site, 2021 - 2023

This dataset contains temperature measurements carried out along two fiber optics cables/lines (150 m each) laid out along the ground at the Next Generation Ecosystem Experiment (NGEE) Arctic site near Council, Alaska. The lines traverse an heterogeneous part of the tussock tundra site including thermokarst features and lichen dominated sections of the tundra. Measurements were done using a Sensornet Oryx DTS, a Distributed Temperature sensor that was installed in September 2021 and taken down in August 2023. The sensor was powered by solar power with data being collected every 30 minutes at 1 m resolution. In addition to these measurements air temperature and incoming photosynthetically active radiation (PAR) are provided. These measurements are co-located with the NGEE Arctic Council eddy flux and meteorological station (AmeriFlux ID US-NGC). Included are six *.csv files (four data files and two reporting format files) and two *.kml files. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

Air temperature↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

High Performance Air Breathing Flexible Lithium–Air Battery

Lithium–oxygen (Li–O 2 ) batteries possess the highest theoretical energy density (3500 Wh kg –1 ), which makes them attractive candidates for modern electronics and transportation applications. In this work, an inexpensive, flexible, and wearable Li–O 2 battery based on the bifunctional redox mediator of InBr 3 , MoS 2 cathode catalyst, and Fomblin-based oxygen permeable membrane that enable long-cycle-life operation of the battery in pure oxygen, dry air, and ambient air is designed, fabricated, and tested. The battery operates in ambient air with an open system air-breathing architecture and exhibits excellent cycling up to 240 at the high current density of 1 A g –1 with a relative humidity of 75%. The electrochemical performance of the battery including deep-discharge capacity, and rate capability remains almost identical after 1000 cycle in a bending fatigue test. Furthermore, this finding opens a new direction for utilizing high performance Li–O 2 batteries for applications in the field of flexible and wearable electronics.

25 ENERGY STORAGE↗

Effect of Storage Conditions on Efficacy of Poly(ethylenimine)-Alumina CO 2 Sorbents

Solid amine sorbents are one of the primary components of DAC technologies that allow for the removal of ultradilute CO 2 from the atmosphere. A main drawback in the implementation of solid amine sorbents in industrial-scale DAC applications is their instability under certain operational or storage conditions over an extended period. In this work, the effect of storage temperature and gas composition in the storage headspace on the long-term stability of a poly(ethylenimine)-alumina (PEI/γ-Al 2 O 3 ) sorbent is explored. PEI/γ-Al 2 O 3 sorbents with 70 and 100% pore filling are aged under varying gases (N 2 , O 2 , Ar, 0.04% CO 2 −N 2 , CO 2 , and ambient air) in an oven (40 °C), at common ambient indoor temperature conditions (23 °C), or in a freezer (−4 °C). The CO 2 sorption capacity, as measured by thermogravimetric analysis (TGA), along with FTIR spectra of the fresh and aged sorbents, reveal that at 23 and −4 °C, storage under ambient air or inert gas (Ar) provides reasonable long-term stability, with <13% degradation over 12 and 5 months of storage. Interestingly, with storage at 40 °C, similar levels of deactivation were observed under pure O 2 and N 2 after 4 months of storage, which suggests that nonoxidative thermal reactions can occur under prolonged storage conditions under N 2 . In contrast, with storage under CO 2 , sorbent degradation is substantially suppressed compared to storage under N 2 , ambient air, O 2 , or Ar, yielding sorbents with no observable loss in capacity after 2 months, compared to a 66, 63, and 62% loss under N 2 , ambient air, and N 2 in the same period at 40 °C, respectively. Overall, these findings provide guidance for practical amine sorbent storage in academic or industrial settings where amine sorbents are used for carbon capture.

Atmospheric chemistry↗