Search NASA⌕ Search

SEARCH · Search NASA

Results for “Anions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Contact transfer of anions from hands as a function of the use of hand lotions

Contact transfer of anions from human hands can result in contamination of materials, increasing their rate of corrosion. Two types of hand lotion were applied to the hands: one was specially formulated for cleanroom use and the other was a popular commercial lotion. The effect on contact transfer of anions was measured versus anion transfer from washed hands without lotions.

ESD contamination hand lotions↗

Tunable Pseudocapacitive Intercalation of Chloroaluminate Anions into Graphite Electrodes for Rechargeable Aluminum Batteries

Rechargeable aluminum-graphite batteries using chloroaluminate-containing electrolytes have been the focus of significant research, particularly due to their high-rate capabilities. Engineered graphite electrodes have been shown to exhibit supercapacitor-like rate performance, despite the fact they store charge via the electrochemical intercalation of polyatomic AlCl4− anions. However, the origins of such rate capabilities are not well understood. Here, using electrochemical techniques, we disentangle quantitatively the diffusion-limited Faradaic, pseudocapacitive, and capacitive contributions to charge storage, revealing that AlCl4− anions intercalate into graphite with significant pseudocapacitive characteristics due to low ion diffusion limitations. Pristine and mildly exfoliated graphites are compared, where exfoliation resulted in significantly higher pseudocapacitive AlCl4− intercalation at the highest potential redox pair as well as higher galvanostatic capacity retention at faster discharge rates. The relationships between graphite structure, ion mass transport, and the overall rate of electrochemical AlCl4− intercalation are discussed. Ion diffusion within the electrolyte phase of the porous electrode is shown to play a key role in controlling the rate of intercalation at higher potentials and faster rates, which can be enhanced by reducing electrode tortuosity. The results establish that chloroaluminate anion intercalation into graphite exhibits non-diffusion-limited pseudocapacitive contributions that are tunable by modifying the graphite structure.

Jeffrey H. Xu↗

The Possible Interstellar Anion CH2CN-: Spectroscopic Constants, Vibrational Frequencies, and Other Considerations

The A 1B1 <-1A0 excitation into the dipole-bound state of the cyanomethyl anion (CH2CN􀀀) has been hypothesized as the carrier for one di use interstellar band. However, this particular molecular system has not been detected in the interstellar medium even though the related cyanomethyl radical and the isoelectronic ketenimine molecule have been found. In this study we are employing the use of proven quartic force elds and second-order vibrational perturbation theory to compute accurate spectroscopic constants and fundamental vibrational frequencies for ~X 1A0 CH2CN􀀀 in order to assist in laboratory studies and astronomical observations. Keywords: Astrochemistry, ISM: molecular anions, Quartic force elds, Rotational constants, Vibrational frequencies

Astrochemistry↗

Ion chromatographic determination of anions collected on filters at altitudes between 9.6 and 13.7 kilometers

The investigation of atmospheric pollution to determine the anion-containing particulates in the atmosphere at altitudes between 9.6 and 13.7 km is discussed. Air samples collected on cellulose fiber discs impregnated with dibutoxyethylphthalate require very sensitive methods of analysis. It is concluded that ion chromatography is suited for the determination of anions collected on the filters. Methods to control contamination and interfering side reactions are described.

Otterson, D. A.↗

Anion permselective membrane

The synthesis and fabrication of polymeric anion permselective membranes for redox systems are discussed. Variations of the prime candidate anion membrane formulation to achieve better resistance and/or lower permeability were explored. Processing parameters were evaluated to lower cost and fabricate larger sizes. The processing techniques to produce more membranes per batch were successfully integrated with the fabrication of larger membranes. Membranes of about 107 cm x 51 cm were made in excellent yield. Several measurements were made on the larger sample membranes. Among the data developed were water transport and transference numbers for these prime candidate membranes at 20 C. Other work done on this system included characterization of a number of specimens of candidate membranes which had been returned after service lives of up to sixteen months. Work with new polymer constituents, with new N.P.'s, catalysts and backing fabrics is discussed. Some work was also done to evaluate other proportions of the ingredients of the prime candidate system. The adoption of a flow selectivity test at elevated temperature was explored.

Hodgdon, R. B.↗

Ab initio determination of the proton affinities of small neutral and anionic molecules

The proton affinity of a molecule in the gas phase is a fundamental measure of its basicity and is the factor controlling the course of many ion-molecule reactions. In this article, ab initio molecular orbital theory at the MP4/6-311 ++ G(3df, 3pd) level of theory is demonstrated to predict proton affinities (PA's) for small neutral and anionic bases to within 2 kcal mol-1. Furthermore, the errors are random, indicating that there are likely no systematic errors in either the experimental or theoretical PA's. Also, this level of theory is used to calibrate less sophisticated theoretical models which are suitable for larger molecules; the MP4/6-311 ++ G(2d, 2p) and MP2/6-311 ++ G(d, p) theoretical models should be particularly useful. A procedure for predicting the vibrational frequencies for anion is proposed and applied to CH3-, NH2-, OH-, and CN-.

Non-NASA Center↗

Anion-Intercalating Cathodes for High-Energy-Density Cells

A report discusses physicochemical issues affecting a fluoride-intercalating cathode that operates in conjunction with a lithium ion-intercalating anode in a rechargeable electrochemical cell described in a cited prior report. The instant report also discusses corresponding innovations made in solvent and electrolyte compositions since the prior report. The advantages of this cell, relative to other lithium-ion-based cells, are said to be greater potential (5 V vs. 4 V), and greater theoretical cathode specific capacity (0.9 to 2.2 A-h/g vs. about 0.18 A-h/g). The discussion addresses a need for the solvent to be unreactive toward the lithium anode and to resist anodic oxidation at potentials greater than about 4.5 V vs. lithium; the pertinent innovation is the selection of propylene carbonate (PC) as a solvent having significantly more stability, relative to other solvents that have been tried. The discussion also addresses the need for an electrolyte additive, denoted an anion receptor, to complex the fluoride ion; the pertinent innovation is the selection of tris(hexafluoroisopropyl) borate as a superior alternative to the prior anion receptor, which was tris(pentafluorophenyl) borate.

West, William↗

Imidazolium-Based Polymeric Materials as Alkaline Anion-Exchange Fuel Cell Membranes

Polymer electrolyte membranes that conduct hydroxide ions have potential use in fuel cells. A variety of polystyrene-based quaternary ammonium hydroxides have been reported as anion exchange fuel cell membranes. However, the hydrolytic stability and conductivity of the commercially available membranes are not adequate to meet the requirements of fuel cell applications. When compared with commercially available membranes, polystyrene-imidazolium alkaline membrane electrolytes are more stable and more highly conducting. At the time of this reporting, this has been the first such usage for imidazolium-based polymeric materials for fuel cells. Imidazolium salts are known to be electrochemically stable over wide potential ranges. By controlling the relative ratio of imidazolium groups in polystyrene-imidazolium salts, their physiochemical properties could be modulated. Alkaline anion exchange membranes based on polystyrene-imidazolium hydroxide materials have been developed. The first step was to synthesize the poly(styrene-co-(1-((4-vinyl)methyl)-3- methylimidazolium) chloride through a free-radical polymerization. Casting of this material followed by in situ treatment of the membranes with sodium hydroxide solutions provided the corresponding hydroxide salts. Various ratios of the monomers 4-chloromoethylvinylbenzine (CMVB) and vinylbenzine (VB) provided various compositions of the polymer. The preferred material, due to the relative ease of casting the film, and its relatively low hygroscopic nature, was a 2:1 ratio of CMVB to VB. Testing confirmed that at room temperature, the new membranes outperformed commercially available membranes by a large margin. With fuel cells now in use at NASA and in transportation, and with defense potential, any improvement to fuel cell efficiency is a significant development.

Narayan, Sri R.↗

Permeation of halide anions through phospholipid bilayers occurs by the solubility-diffusion mechanism

Two alternative mechanisms are frequently used to describe ionic permeation of lipid bilayers. In the first, ions partition into the hydrophobic phase and then diffuse across (the solubility-diffusion mechanism). The second mechanism assumes that ions traverse the bilayer through transient hydrophilic defects caused by thermal fluctuations (the pore mechanism). The theoretical predictions made by both models were tested for halide anions by measuring the permeability coefficients for chloride, bromide, and iodide as a function of bilayer thickness, ionic radius, and sign of charge. To vary the bilayer thickness systematically, liposomes were prepared from monounsaturated phosphatidylcholines (PC) with chain lengths between 16 and 24 carbon atoms. The fluorescent dye MQAE (N-(ethoxycarbonylmethyl)-6-methoxyquinolinium bromide) served as an indicator for halide concentration inside the liposomes and was used to follow the kinetics of halide flux across the bilayer membranes. The observed permeability coefficients ranged from 10(-9) to 10(-7) cm/s and increased as the bilayer thickness was reduced. Bromide was found to permeate approximately six times faster than chloride through bilayers of identical thickness, and iodide permeated three to four times faster than bromide. The dependence of the halide permeability coefficients on bilayer thickness and on ionic size were consistent with permeation of hydrated ions by a solubility-diffusion mechanism rather than through transient pores. Halide permeation therefore differs from that of a monovalent cation such as potassium, which has been accounted for by a combination of the two mechanisms depending on bilayer thickness.

NASA Discipline Exobiology↗

Simultaneous quantification of poly-dispersed anionic, amphoteric and nonionic surfactants in simulated wastewater samples using C18 high-performance liquid chromatography-quadrupole ion-trap mass spectrometry

This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.

Chromatography, High Pressure Liquid/methods↗

Optimizing Surfactant Templating of Yttria-Stabilized Zirconia Aerogels for High-Temperature Applications: Effect of Anionic and Nonionic Surfactant

Aerogels, mesoporous materials with extreme material properties including high specific surface area, low density, and low thermal conductivity, can be useful for applications including catalysis, sorption media, and drug delivery. The low thermal conductivity and high surface area of aerogels makes them advantageous as thermal management systems, specifically for aerospace or aeronautics applications. However, the pore collapse and subsequent surface area decrease of aerogels following exposure to high temperatures must be mitigated to allow aerogels to be effectively used in thermal management applications. This work investigates the anionic surfactant sodium dodecyl sulfate (SDS) and the nonionic surfactant Pluronic® P-123 as surfactant templates in yttria-stabilized zirconia (YSZ) aerogels. By utilizing surfactant templates, known to influence pore structure, it is anticipated that sintering and densification of the aerogels following high-temperature exposure will be mitigated. It was determined that the addition of SDS and P-123 increased the surface area and pore volume of as-dried aerogels and suppressed crystallite growth at high temperatures. However, the impact of surfactant templates on the surface area and pore volume of heat-treated aerogels was negligible, potentially due to low concentrations of surfactant and the removal of the surfactant following high-temperature exposure.

Yttria-stabilized zirconia aerogels↗

Separation of the rare earths by anion-exchange in the presence of lactic acid

Investigation of adsorption of rare earths and a few other elements to an anion-exchange resin from mixed solvents containing lactic acid shows that the lanthanides are absorbed more strongly than from the alpha-hydroxyisobutryric acid system, but with less separation between adjacent members of the series.

Faris, J. P.↗