Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ankle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A quasi-linear control theory analysis of timesharing skills

The compliance of the human ankle joint is measured by applying 0 to 50 Hz band-limited gaussian random torques to the foot of a seated human subject. These torques rotate the foot in a plantar-dorsal direction about a horizontal axis at a medial moleolus of the ankle. The applied torques and the resulting angular rotation of the foot are measured, digitized and recorded for off-line processing. Using such a best-fit, second-order model, the effective moment of inertia of the ankle joint, the angular viscosity and the stiffness are calculated. The ankle joint stiffness is shown to be a linear function of the level of tonic muscle contraction, increasing at a rate of 20 to 40 Nm/rad/Kg.m. of active torque. In terms of the muscle physiology, the more muscle fibers that are active, the greater the muscle stiffness. Joint viscosity also increases with activation. Joint stiffness is also a linear function of the joint angle, increasing at a rate of about 0.7 to 1.1 Nm/rad/deg from plantar flexion to dorsiflexion rotation.

Agarwal, G. C.↗

Achilles Tendon Reflex (ATR) in response to short exposures of microgravity and hypergravity

Previous studies indicate that latency and amplitude of the Achilles tendon reflex (ATR) are reduced after exposure to microgravity for 28 days. The objective of this study was to quantitatively measure the latency of ATR during brief (20 sec) exposure to microgravity in KC-135 parabolic flights. Methods: The ATR was elicited in ten men during parabolic flight with the ankle held neutrally, planarflexed, and dorsiflexed. During flight, the ATR was elicited during the zero G and 1.8 G phases. Postflight testing was performed flying back to the airfield. Latencies to onset of the ATR were calculated and analyses of variance were performed to determine the effect of gravity and ankle position on latency. Result: The mean latencies for zero-G, 1.8-G and postflight with the ankle in the neutral position were 32.7 plus or minus 0.5 ms, and 33.1 plus or minus 0.7 ms respectively, which were not significantly different. There was a trend toward prolongation of latencies postflight. The mean latency for those who were motion sick was 32.1 plus or minus 0.1 ms compared to 34.0 plus or minus 0.3 ms for those who were not sick. Conclusions: These studies indicate that neither the level of gravity nor ankle position significantly affected the latency of the ATR.

Fujii, M.↗

Isokinetic and isometric strength-endurance after 6 hours of immersion and 6 degrees head-down tilt in men

PURPOSE: To determine weight (water) loss levels for onset of muscular strength and endurance changes during deconditioning. METHODS: Seven men (27-40 yr) performed maximal shoulder-, knee-, and ankle-joint isometric (0 degree.s(-1) load) and isokinetic (60 degrees, 120 degrees, 180 degrees.s(-1) velocity) exercise tests during ambulatory control (AC), after 6 h of 6 degrees head-down tilt (HDT; dry-bulb temp. = 23.2 +/- SD 0.6 degrees C, relative humidity = 31.1+/- 11.1%) and after 6 h of 80 degrees foot-down head-out water immersion (WI; water temp. = 35.0 +/- SD 0.1 degree C) treatments. RESULTS: Weight (water) loss after HDT (1.10 +/- SE 0.14 kg, 1.4 +/- 0.2% body wt) and WI (1.54+/- 0.19 kg, 2.0 +/- 0.2% body wt) were not different, but urinary excretion with WI (1,354 +/- 142 ml.6 h(-1)) was 28% greater (p < 0.05) than that of 975 +/- 139 ml.6 h(-1) with HDT. Muscular endurance (total work; maximal flexion-extension of the non-dominant knee at 180 degrees.s(-1) for 30 s) was not different between AC and the WI or HDT treatments. Shoulder-, knee-, and ankle-joint strength was unchanged except for three knee-joint peak torques: AC torque (120 degrees.s(-1), 285 +/- 20 Nm) decreased to 268 +/- 21 Nm (delta = -6%, p < 0.05) with WI; and AC torques (180 degrees.s(-1), 260 +/- 19 Nm) decreased to 236 +/- 15 Nm (delta = -9%, p < 0.01) with HDT, and to 235 +/- 19 Nm (delta = -10%, p < 0.01) with WI. CONCLUSION: Thus, the total body hypohydration threshold level for shoulder- and ankle-joint strength and endurance decrements is more than 2% body weight (water) loss, while significant reduction in knee-joint muscular strength-endurance occurred only at moderate (120 degrees.s(-1) and lighter (180 degrees.s(-1)) loads with body weight loss of 1.4-2.0% following WI or HDT, respectively. These weight (water) losses and knee-joint strength decrements are somewhat less than the mean weight loss of 2.6% and knee-joint strength decrements of 6-20% of American astronauts after Skylab flights to 84 d.

NASA Center ARC↗

Intramuscular pressure and electromyography as indexes of force during isokinetic exercise

A direct method for measuring force production of specific muscles during dynamic exercise is presently unavailable. Previous studies indicate that both intramuscular pressure (IMP) and electromyography (EMG) correlate linearly with muscle contraction force during isometric exercise. The objective of this study was to compare IMP and EMG as linear assessors of muscle contraction force during dynamic exercise. IMP and surface EMG activity were recorded during concentric and eccentric isokinetic plantarflexion and dorsiflexion of the ankle joint from the tibialis anterior (TA) and soleus (SOL) muscles of nine male volunteers. Ankle torque was measured using a dynamometer, and IMP was measured via catheterization. IMP exhibited better linear correlation than EMG with ankle joint torque during concentric contractions of the SOL and the TA, as well as during eccentric contractions. IMP provides a better index of muscle contraction force than EMG during concentric and eccentric exercise through the entire range of torque. IMP reflects intrinsic mechanical properties of individual muscles, such as length-tension relationships, which EMG is unable to assess.

Aratow, M.↗

Fiber size and myosin phenotypes of selected rhesus lower limb muscles after a 14-day spaceflight

Muscle biopsies were taken from the rhesus (Macaca mulatta) soleus (Sol, a slow ankle extensor), medial gastrocnemius (MG, a fast ankle extensor), tibialis anterior (TA, a fast ankle flexor), and vastus lateralis (VL, a fast knee extensor) muscles in vivarium controls (n=5) before and after either a 14-day spaceflight (Bion 11, n=2) or a 14-day ground-based flight simulation (n=3). Myosin heavy chain (MHC) composition (gel electrophoresis), fiber type distribution (immunohistochemistry), and fiber size were determined. Although there were no significant changes, each muscle showed trends towards adaptation.

NASA Discipline Musculoskeletal↗

Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

Laughlin, Mitzi S.↗

The Role of Adaptation in Body Load-Regulating Mechanisms During Locomotion

Body loading is a fundamental parameter that modulates motor output during locomotion, and is especially important for controlling the generation of stepping patterns, dynamic balance, and termination of locomotion. Load receptors that regulate and control posture and stance in locomotion include the Golgi tendon organs and muscle spindles at the hip, knee, and ankle joints, and the Ruffini endings and the Pacinian corpuscles in the soles of the feet. Increased body weight support (BWS) during locomotion results in an immediate reorganization of locomotor control, such as a reduction in stance and double support duration and decreased hip, ankle, and knee angles during the gait cycle. Previous studies on the effect during exposure to increased BWS while walking showed a reduction in lower limb joint angles and gait cycle timing that represents a reorganization of locomotor control. Until now, no studies have investigated how locomotor control responds after a period of exposure to adaptive modification in the body load sensing system. The goal of this research was to determine the adaptive properties of body load-regulating mechanisms in locomotor control during locomotion. We hypothesized that body load-regulating mechanisms contribute to locomotor control, and adaptive changes in these load-regulating mechanisms require reorganization to maintain forward locomotion. Head-torso coordination, lower limb movement patterns, and gait cycle timing were evaluated before and after a 30-minute adaptation session during which subjects walked on a treadmill at 5.4 km/hr with 40% body weight support (BWS). Before and after the adaptation period, head-torso and lower limb 3D kinematic data were obtained while performing a goal directed task during locomotion with 0% BWS using a video-based motion analysis system, and gait cycle timing parameters were collected by foot switches positioned under the heel and toe of the subjects shoes. Subjects showed adaptive modification in the body load-regulating mechanisms that included increased head movement amplitude, increased knee and ankle flexion, and increased stance, stride, and double support time, with no change in the performance of the task with respect to that measured before exposure to BWS. These changes in locomotor control are opposite to that reported during 40% BWS exposure and indicative of an after-effect after removal of the adaptive stimulus. Therefore, it is evident that just 30 minutes of 40% BWS during locomotion was sufficient to induce adaptive modifications in the body load sensing systems that contribute to reorganization of sensory contributions to stable locomotor control.

Ruttley, Tara↗

Kinematics and Kinetics of Squat and Deadlift Exercises with Varying Stance Widths

The primary motion of squat and deadlift exercise involves flexion and extension of the hips, knees, and ankles, but each exercise can be performed with variations in stance width. These variations may result in differing kinematics and ground reaction forces (GRF), which may in turn affect joint loading. PURPOSE: The purpose of this investigation was to compare ankle, knee, and hip kinematics and kinetics of normal squat (NS), wide-stance squat (WS), normal deadlift (ND), and sumo deadlift (SD). We hypothesized that hip joint kinematics and work at each joint would differ between exercise variations. METHODS: Six subjects (3 m/3 f; 70.0 plus or minus 13.7 kg; 168 plus or minus 9.9 cm) performed each lift in normal gravity on the ground-based version of the Advanced Resistive Exercise Device (ARED) used on the International Space Station. The ARED provided resistance with a combination vacuum tube/flywheel mechanism designed to replicate the gravitational and inertial forces of free weights. Subjects completed each lift with their 10-repetition maximum load. Kinematic data were collected at 250 Hz by a 12-camera motion-capture system (Smart-D, BTS Bioengineering, Milan, Italy), and GRF data were collected at 1000 Hz with independent force platforms for each leg (Model 9261, Kistler Instruments AG, Winterhur, Switzerland). All data were captured simultaneously on a single workstation. The right leg of a single lift for each motion was analyzed. Modeling software (OpenSim 2.2.0, Simbios, Palo Alto, CA) determined joint kinematics and net positive and negative work at each lower extremity joint. Total work was found as the sum of work across all joints and was normalized by system mass. Effect sizes and their 95% confidence intervals were computed between conditions. RESULTS: Peak GRF were similar for each lift. There were no differences between conditions in hip flexion range of motion (ROM). For hip adduction ROM, there were no differences between the NS, WS, and SD. However, hip adduction ROM was greater during the NS and SD than during the ND. Hip rotation ROM was greater during the WS than during the NS and SD, and was greater during the SD than during the ND. For knee and ankle flexion ROM, the ND, WS, and SD were not different, but ROM was greater during the NS than the ND and greater during the WS than the SD. Total eccentric work was greater during the WS than the SD. Otherwise, there were no differences in eccentric or concentric work between conditions. CONCLUSIONS: Although squat and deadlift exercises consist of similar motions, there are kinematic differences between them that depend on stance width. Total eccentric and concentric work are similar for different lifts, but differing kinematics may require activation of different musculature for each variation. With respect to each condition, in the ND the ROM of each joint tended to be less, and the WS tended to trade knee motion for hip motion. PRACTICAL APPLICATIONS: Knowledge of differences in kinematics and kinetics between different squat and deadlift variations is important for coaches and rehabilitation personnel to understand when prescribing exercise. Our results suggest that each variation of the squat and deadlift should be considered a separate exercise that may induce different long-term training effects.

DeWitt, John K.↗

Credibility Assessment and Evaluation of the Astronaut Musculoskeletal Boot/Ankle Injury Scenario Using Open SIM(TM) Computational Modeling

The musculoskeletal system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an extravehicular activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. One area of concern are injuries occurring at the feet and ankles due to a poor fit of the spacesuit boot. These injuries can occur if the boot does not support the ankle sufficiently and the astronaut steps awkwardly, twisting the ankle or foot, during an EVA. The OpenSimTM software can assess EVA induced musculoskeletal injuries for muscle strains, ligament injuries and joint injuries. A modeling and simulation credibility assessment of the OpenSim musculoskeletal modeling and simulation procedures, applied to the boot/ankle injury scenario injury mechanisms that may occur while carrying out tasks in these environments, is performed. These modeling and simulation credibility assessments give information on the credibility of the model’s use in simulating foot/ankle related injury mechanisms.

C A Gallo↗

The Second Skin: A Wearable Sensor Suite that Enables Real-Time Human Biomechanics Tracking Through Deep Learning

Objective: Real-time determination of human kinematics and kinetics could advance biomechanics research and enable valuable applications of biofeedback and generalizable exoskeleton control. Here, this work aims to investigate a taskindependent, user-independent method for obtaining precise realtime joint state estimation across lower-body joints during a wide variety of tasks. Methods: We developed a generalizable sensing approach using a suit comprised of inertial measurement units (IMUs) and pressure insoles. With the suit, we collected a dataset of 33 tasks commonly performed during construction and hazardous waste cleanup (N = 10). We then trained deep learning user-independent, task-agnostic models to estimate joint lowerbody kinematics and dynamics using only worn sensor data. We likewise computed joint kinematics and dynamics analytically from sensor data to serve as a comparison tool for model results. Results: Our models achieved overall angle estimation root-meansquared-errors (RMSE) of 6.56±.92°, 8.60±1.01°, 7.58±.89°, and 6.00±.73° compared to 13.9±.1.3°, 15.31±1.0°, 10.76±.70°, and 7.56±.48° via analytical methods at the lower back, hip, knee, and ankle, respectively. Likewise, our models achieved overall normalized moment estimation RMSEs of .207±.069 Nm/kg, .242±.044 Nm/kg, .202±.038 Nm/kg, and .193±.034 Nm/kg compared to .306±.036 Nm/kg, .407±.021 Nm/kg, 1.18 ±.022 Nm/kg, and 1.73±.071 Nm/kg via analytical methods at the lower back, hip, knee, and ankle, respectively. Conclusion: These results are comparable to other state-of-the-art wearable sensing systems, establishing deep learning as a viable sensing approach that generalizes to new users and tasks. Significance: This work shows promise for enabling accurate real-world biomechanical data collection and enhancement of biofeedback systems and wearable robot control.

Casey, Ryan T. F. [Georgia Institute of Technology↗

Directional errors of movements and their correction in a discrete tracking task

Subjects can correct their own errors of movement more quickly than they can react to external stimuli by using three general categories of feedback: (1) knowledge of results, primarily visually mediated; (2) proprioceptive or kinaesthetic such as from muscle spindles and joint receptors, and (3) corollary discharge or efference copy within the central nervous system. The effects of these feedbacks on simple reaction time, choice reaction time, and error correction time were studied in four normal human subjects. The movement used was plantarflexion and dorsiflexion of the ankle joint. The feedback loops were modified, by changing the sign of the visual display to alter the subject's perception of results, and by applying vibration at 100 Hz simultaneously to both the agonist and antagonist muscles of the ankle joint. The central processing was interfered with when the subjects were given moderate doses of alcohol (blood alcohol concentration levels of up to 0.07%). Vibration and alcohol increase both the simple and choice reaction times but not the error correction time.

Jaeger, R. J.↗

Body acceleration distribution and O2 uptake in humans during running and jumping

The distribution of body acceleration and associated oxygen uptake and heart rate responses are investigated in treadmill running and trampoline jumping. Accelerations in the +Gz direction were measured at the lateral ankle, lumbosacral region and forehead of eight young men during level treadmill walking and running at four speeds and trampoline jumping at four heights, together with corresponding oxygen uptake and heart rate. With increasing treadmill speed, peak acceleration at the ankle is found always to exceed that at the back and forehead, and acceleration profiles with higher frequency components than those observed during jumping are observed. Acceleration levels are found to be more uniformly distributed with increasing height in jumping, although comparable oxygen uptake and heat rates are obtained. Results indicate that the magnitude of the biomechanical stimuli is greater in trampoline jumping than in running, which finding could be of use in the design of procedures to avert deconditioning in persons exposed to weightlessness.

Bhattacharya, A.↗

Computational problems in autoregressive moving average (ARMA) models

The choice of the sampling interval and the selection of the order of the model in time series analysis are considered. Band limited (up to 15 Hz) random torque perturbations are applied to the human ankle joint. The applied torque input, the angular rotation output, and the electromyographic activity using surface electrodes from the extensor and flexor muscles of the ankle joint are recorded. Autoregressive moving average models are developed. A parameter constraining technique is applied to develop more reliable models. The asymptotic behavior of the system must be taken into account during parameter optimization to develop predictive models.

Agarwal, G. C.↗

Daily rhythms of activity and temperature of Macaca nemestrina

The activity and temperature rhythms of pig-tailed macaques (Macaca nemestrina) maintained in LD 16:8 at 25 C in specially designed restraint chairs have been examined. Activity was monitored via a sensor that was attached to the restraint chair. Temperature was monitored at the axilla, ankle and ear. All variables showed prominent day-night variations, and except for ankle temperature, had highest values during the daytime. These results show that the regulation of the daily rhythm of body temperature involves anatomical sites that are utilized in a temporally distinct fashion.

Sulzman, F. M.↗

Effects of immobilization on rat hind limb muscles under non-weight-bearing conditions

The effect of stretched and unstretched immobilization of a hind limb on the concentration and the metabolism of proteins in the hind-limb muscles of rats was investigated. The animals were divided into three groups: (1) weight-bearing controls, (2) tail-cast-suspended, and (3) suspended, with one hind limb immobilized with the ankle in dorsiflexion (30-40 deg angle) and the other freely moving. It was found that unloading the hind limbs for 6 days by tail cast suspension caused soleus to atrophy and reduced growth of the gastrocnemius and plantaris muscles; unloading resulted in a higher degradation rate and lower synthesis rate in both in vitro and in vivo. Chronic stretch of the unloaded soleus not only prevented its atrophy but led to significant hypertrophy, relative to weight-bearing controls, with increases in both the sarcoplasmic and myofibrillar protein fractions. Immobilizing one ankle in dorsiflexion prevented the inhibition of growth in the plantaris and gastrocnemius muscles due to unloading.

Jaspers, Stephen R.↗

Characteristics and preliminary observations of the influence of electromyostimulation on the size and function of human skeletal muscle during 30 days of simulated microgravity

The effect of transcutaneous electromyostimulation (EMS) on the development of atrophy and the loss of strength in lower limb musculature in humans exposed to microgravity was determined in three subjects who received EMS twice daily in a 3-d on/1-d off cycle on their dominant leg during 30 days of bedrest. The output waveform from the stimulator was sequenced to the knee extensors, knee flexors, ankle extensors, and ankle flexors, and caused three isometric contractions of each muscle group per minute. It was found that, in the dominant leg, EMS acted to attenuate the changes caused by bedrest, such as reductions in the leg volume, muscle compartment size, cross-sectional area of slow- and fast-twitch fibers, strength, and aerobic enzyme activities, and an increase in leg compliance.

Duvoisin, Marc R.↗

Adaptation of skeletal muscle to spaceflight: Cosmos rhesus project. Cosmos 2044 and 2229

The proposed experiments were designed to determine the effects of the absence of weight support on hindlimb muscles of the monkey: an ankle flexor (tibialis anterior, TA), two ankle extensors (medial gastrocnemius, MG and soleus, SOL), and a knee extensor (vastus lateralis, VL). These effects were assessed by examining the biochemical and morphological properties of muscle fibers obtained from biopsies in young Rhesus monkeys (3-4 Kg). Biopsies taken from ground base experiments were analyzed to determine: (1) the effects of chair restraint at 1 G on muscle properties and (2) the growth rate of flexor and extensor muscles in the Rhesus. In addition, two sets of biopsies were taken from monkeys which were in the flight pool and the four monkeys that flew on the Cosmos 2044 and 2229 biosatellite missions. Based on data collected in rats it is generally assumed that extensors atrophy to a greater extent than flexors in response to spaceflight or hindlimb suspension. Consequently, the finding that fibers in the TA (a fast flexor) of the flight monkeys atrophied, whereas fibers in the Sol (a predominantly slow extensor) and MG (a fast extensor) grew after a 14-day spaceflight (Cosmos 2044) and 12-day spaceflight (Cosmos 2229) was unexpected. In Cosmos 2044, the TA in both flight monkeys had a 21 percent decrease in fiber size, whereas the Sol and MG both had a 79 percent increase in fiber size. In Cosmos 2229, the TA in both flight monkeys showed significant atrophy, whereas the Sol and MG showed slight growth in one monkey (906) and slight atrophy in the other monkey (151).

Bodine-Fowler, Sue↗

Intramuscular pressure: A better tool than EMG to optimize exercise for long-duration space flight

A serious problem experienced by astronauts during long-duration space flight is muscle atrophy. In order to develop countermeasures for this problem, a simple method for monitoring in vivo function of specific muscles is needed. Previous studies document that both intramuscular pressure (IMP) and electromyography (EMG) provide quantitative indices of muscle contraction force during isometric exercise. However, at present there are no data available concerning the usefulness of IMP versus EMG during dynamic exercise. Methods: IMP (Myopress catheter) and surface EMG activity were measured continuously and simultaneously in the tibalis anterior (TA) and soleus (SOL) muscles of 9 normal male volunteers (28-54 years). These parameters were recorded during both concentric and eccentric exercises which consisted of plantarflexon and dorsiflexon of the ankle joint. A Lido Active Isokinetic Dynamometer concurrently recorded ankle joint torque and position. Results: Intramuscular pressure correlated linearly with contraction force for both SOL (r exp 2 = 0.037) and TA (R exp 2 = 0.716 and r exp 2 = 0.802, respectively). During eccentric exercises, SOL and TA IMP also correlated linearly with contraction force (r(exp 2) = 0.883 and r(exp 2) = 0.904 respectively), but SOL and TA EMG correlated poorly with force (r(exp 2) = 0.489 and r(exp 2) = 0.702 respectively). Conclusion: IMP measurement provides a better index of muscle contraction force than EMG during concentric and eccentric exercise. IMP reflects intrinsic mechanical properties of individual muscles, such as length tension relationships. Although invasive, IMP provides a more powerful tool and EMG for developing exercise hardware and protocols for astronauts exposed to long-duration space flight.

Hargens, A. R.↗