Search NASA⌕ Search

SEARCH · Search NASA

Results for “Anodic Coloring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

35 records · Page 2

Method of detecting defects in ion exchange membranes of electrochemical cells by chemochromic sensors

A method of detecting defects in membranes such as ion exchange membranes of electrochemical cells. The electrochemical cell includes an assembly having an anode side and a cathode side with the ion exchange membrane in between. In a configuration step a chemochromic sensor is placed above the cathode and flow isolation hardware lateral to the ion exchange membrane which prevents a flow of hydrogen (H.sub.2) between the cathode and anode side. The anode side is exposed to a first reactant fluid including hydrogen. The chemochromic sensor is examined after the exposing for a color change. A color change evidences the ion exchange membrane has at least one defect that permits H.sub.2 transmission therethrough.

30 DIRECT ENERGY CONVERSION↗

Formation of a Thin Luminescent Layer in LiF Crystals under Glow Discharge Radiation

The formation of thin layers of luminescent defects on the faces of planar lithium fluoride crystals located in the positive column and Faraday dark space of a glow gas discharge was studied by time-resolved confocal scanning luminescent microscopy and time-correlated single photon counting. The formation of aggregated color centers in the surface layers of crystals was established using the spectral and kinetic characteristics of luminescence appearing after irradiation. The role of gas discharge electrons, ions, and photons in the defect formation mechanism was considered. The defects were shown to be formed under the influence of vacuum ultraviolet (VUV) photons. The VUV radiation intensity distribution in the discharge gap was measured by the method of thermostimulated luminescence. The main source of this radiation was the anodic and cathodic voltage drop regions in a glow discharge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anodizing Process

This anodizing process traces its origin to the 1960's when Reynolds Metals Company, under contract with Goddard Space Flight Center, developed a multipurpose anodizing electrolyte (MAE) process to produce a hard protective finish for spacecraft aluminum. MAE produces a high-density, abrasion-resistant film prior to the coloring step, in which the pores of the film are impregnated with a metallic form of salt. Tru-Color product applications include building fronts, railing, curtain walls, doors and windows.

Source record↗

Lithium storage in structurally tunable carbon anode derived from sustainable source

Here, a meticulous solid state chemistry approach has been developed for the synthesis of carbon anode from a sustainable source. The reaction mechanism of carbon formation during pyrolysis of sustainable feed-stock was studied in situ by employing Raman microspectroscopy. No Raman spectral changes observed below 160°C (thermally stable precursor) followed by color change, however above 280°C characteristic D and G bands of graphitic carbon are recorded. Derived carbon particles exhibited high specific surface area with low structural ordering (active carbons) to low specific surface area with high graphitic ordering as a function of increasing reaction temperature. Carbons synthesized at 600°C demonstrated enhanced reversible lithiation capacity (390 mAh g -1 ), high charge-discharge rate capability, and stable cycle life. On the contrary, carbons synthesized at higher temperatures (>1200°C) produced more graphite-like structure yielding longer specific capacity retention with lower reversible capacity.

09 BIOMASS FUELS↗

Ultra-High-Speed X-ray Tomography: Bridging the Gaps to See the Unknown

Rapid, time-varying, three-dimensional physics underpin numerous engineering challenges. Often, these physics occur within opaque environments, internal to a component, severely limiting applicable diagnostics. Development of novel diagnostics is necessary to understand and predict transient three-dimensional (3D) phenomena within opaque environments. This report highlights progress in four key areas leading to advancements in high-speed X-ray radiography and tomography. The first area is enabling MHz-rate imaging of energetics at the Advanced Photon Source at Argonne National Laboratory. The second is modeling a high-flux, rotating-anode X-ray source to understand the heat loads on the anode. The third effort was to develop a novel reconstruction algorithm that is validated by ground experimental tomography data and synthetic tomography data. The fourth is the development of a novel approach to two-color X-ray imaging.

42 ENGINEERING↗

Thermal Control using Electrochromism

The applicability of a charge balanced electrochromic device to modulate the frequencies in the thermal infrared region is examined in this study. The device consisted of a transparent conductor, WO3 anode, PMMA/LiClO4 electrolyte, V2O5 cathode and transparent conductor. The supporting structure in the device is SnO2 coated glass and the edges are sealed with epoxy to reduce moisture absorption. The performance evaluation comprised of cyclic voltammetric measurements and determination of transmittance at various wavelengths. The device was subjected to anodic and cathodic polarization by sweeping the potential at a rate of 10 mV/sec from -0.8V to 1.8V. The current versus voltage profile indicated no reaction between -0.5 and +0.5 V. The device is colored green at 1.8V with a transmittance of 5% at a wavelength, lambda=900 nm and colorless at -0.8V with a transmittance of 74% at lambda=500 nm. The optical modulation is limited to 400-1500 nm and there is no activity in the thermal infrared. The switching time is 75 seconds for transmittance to decrease from 74% to 50%. The device yielded reproducible values for transmittance when cycled between colored and bleached states by application of 1.8V and -0.8V, respectively.

Vaidyanathan, Hari↗

Thermal Control Using Electrochromism

The applicability of a charge balanced electrochromic device to modulate the frequencies in the thermal infra red region is examined in this study. The device consisted of a transparent conductor, WO3 anode, PMMA/LiClO4, electrolyte, V2O5, cathode and transparent conductor. The supporting structure in the device is SnO2 coated glass and the edges are sealed with epoxy to reduce moisture absorption. The performance evaluation comprised of cyclic voltammetric measurements and determination of transmittance at various wavelengths. The device was subjected to anodic and cathodic polarization by sweeping the potential at a rate of 10 mV/sec from -0.8 V to 1.8 V. The current versus voltage profile indicated no reaction between -0.5 and +0.5 V. The device is colored green at 1.8 V with a transmittance of 5% at a wavelength, lambda = 900 nm and colorless at -0.8 V with a transmittance of 74% at X = 500 nm. The optical modulation is limited to 400-1500 nm and there is no activity in the thermal infrared. The switching time is 75 seconds for transmittance to decrease from 74% to 50%. The device yielded reproducible values for transmittance when cycled between colored and bleached states by application of 1.8 V and -0.8 V, respectively.

Vaidyanathan, Hari↗

Thermal Control Using Electrochromism

The applicability of a charge balanced electrochromic device to modulate the frequencies in the thermal infrared region is examined in this study. The device consisted of a transparent conductor, WO3, anode, PMMA/LiClO4 electrolyte, V2O5 cathode and transparent conductor. The supporting structure in the device is SnO2 coated glass and the edges are sealed with epoxy to reduce moisture absorption. The performance evaluation comprised of cyclic voltammetric measurements and determination of transmittance at various wavelengths. The device was subjected to anodic and cathodic polarization by sweeping the potential at a rate of 10 mV/sec from -0.8V to 1.8V. The current versus voltage profile indicated no reaction between -0.5 and +0.5 V. The device is colored green at 1.8 V with a transmittance of 5% at a wavelength, lambda = 900 nm and colorless at -0.8 V with a transmittance of 74% at lambda = 500 nm. The optical modulation is limited to 400-1500 nm and there is no activity in the thermal infrared. The switching time is a function of temperature and time for coloring reaction was slower than the bleaching reaction. The device yielded reproducible values for transmittance when cycled between colored and bleached states by application of 1.8V and -0.8V, respectively.

Vaidyanathan, Hari↗

Kinetics of Coloration in Hydrogenated Vanadium Pentoxide Films under an Internal Electrochromic Effect

The kinetics of coloration in thin hydrogenated vanadium pentoxide films under the internal electrochromic effect is studied alongside with the influence of their hydrogenation by means of plasma-immersion ion implantation on this process. The variant of uniform implantation and the nonuniform case when a film is partially subjected to ion treatment are considered. Based on the experiments on measuring the electrochromically colored surface area growth rate and the passing current, it has been revealed that the electrochromic effect becomes much stronger in the nonuniform variant, when the cathode is placed on the nonhydrogenated part of a film, and the anode is located on its hydrogenated part.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Luminescence parameters of InP/ZnS@AAO nanostructures

Nanostructured membranes of anodic aluminum oxide (AAO) with InP/ZnS semiconductor nanocrystals deposited in pores were synthesized by electrochemical technique, physical deposition and post processing in an ultrasonic bath. Photoluminescence spectra of the samples were studied. Fluorescent properties of the quantum dots are found to be retained after the deposition. The color range is illustrated that can be covered using membranes annealed at temperatures < 900°C and by varying the concentration of the deposited InP/ZnS nanocrystals. Chromaticity coordinates and correlated color temperature for the fabricated white InP/ZnS@AAO phosphor are (0.21, 0.26) and 4115 K, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast Proton Insertion in Layered H 2 W 2 O 7 via Selective Etching of an Aurivillius Phase

H 2 W 2 O 7 , a metastable material synthesized via selective etching of the Aurivillius-related Bi 2 W 2 O 9 , is shown as an electrode for high power proton-based energy storage. Comprehensive structural characterization is performed to obtain a high-fidelity crystal structure of H 2 W 2 O 7 using an iterative approach that combines X-ray diffraction, neutron pair distribution function, scanning transmission electron microscopy, Raman spectroscopy, and density functional theory modeling. Electrochemical characterization shows a capacity retention of ≈80% at 1000 mV s –1 (1.5-s charge/discharge time) as compared to 1 mV s –1 (≈16-min charge/discharge time) with cyclability for over 100 000 cycles. Energetics from density functional theory calculations indicate that proton storage occurs at the terminal oxygen sites within the hydrated interlayer. Last, optical micrographs collected during in situ Raman spectroscopy show reversible, multicolor electrochromism, with color changes from pale yellow to blue, purple, and last, orange as a function of proton content. These results highlight the use of selective etching of layered perovskites for the synthesis of metastable transition metal oxide materials and the use of H 2 W 2 O 7 as an anode material for proton-based energy storage or electrochromic applications.

25 ENERGY STORAGE↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Anode-type double layers in a nonuniform magnetic field

The properties of strong, magnetized, three-dimensional double layers are studied. The double layers are produced by drawing a discharge to a large anode plate located in the diverging magnetic field region of a cylindrical argon discharge. If the anode voltage is sufficiently high, the electrons that are accelerated through the anode sheath may become sufficiently energetic to ionize the background neutral gas and transform the anode sheath into a strong double layer. The resulting conical-shaped structures, which extend outward from the plate, have parallel, oblique, and perpendicular electric field components with respect to the magnetic field. The axial extent of these structures depends on the plate bias voltage, neutral gas pressure, and the magnetic field. At neutral gas pressures of a few millitorr, the double-layer structures are visually apparent because of the enhanced light emission from neutrals excited by the energetic electrons. Color photographs of some of these structures are shown. The scaling of the width of these double layers with electric field components perpendicular to B is also investigated.

Cartier, Steven L.↗

Manufacturable Corrugated Substrates for High Efficiency Organic Light-Emitting Diodes (OLEDs)

In this project, we start with optical simulation of an OLED to have a basic understanding of the mode dispersion inside the device. We first fabricated 1-D photonic crystals’ (PhCs) for corrugated green OLED devices observed enhanced EQE from 20% to 27%, which has the drawbacks of angular color shift. To resolve this issue, we fabricated poly crystalline PhCs (poly PhC) devices and observed alleviated angular color shift. The outcoupling efficiency is enhanced from 30% to 35%, which can be further enhanced to 60% by extracting the substrate mode. To further enhance the efficiency, we used RCWA (rigorous coupled-wave analysis) simulation to study the optical property in the corrugated device. We found out the corrugation reduces the reflectance of the Al cathode, lowers the cavity resonance and weakens the cavity emission. To preserve the cavity effect, we insert a low index Teflon layer (n = 1.3) between the ITO anode and the corrugated substrate, which increased the index contrast and hence the reflectance of the bottom electrode. As a result, the corrugated OLED with a Teflon layer shows a maximum outcoupling efficiency of 75%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

Closed bipolar electrode-enabled dual-cell electrochromic detectors for chemical sensing

Bipolar electrodes (BPE) are electrically floating metallic elements placed in electrified fluids that enable the coupling of anodic and cathodic redox reactions at the opposite ends by electron transfer through the electrode. One particularly compelling application allows electron transfer reactions at one end of a closed BPE to be read out optically by inducing a redox-initiated change in the optical response function of a reporter system at the other end. Here, a BPE-enabled method for electrochemical sensing based on the electrochromic response of a methyl viologen (MV) reporter is developed, characterized, and rendered in a field-deployable format. BPE-enabled devices based on two thin-layer-cells of ITO and Pt were fabricated to couple an analytical reaction in one cell with an MV reporter reaction, producing a color change in the complementary cell. Using Fe(CN) 6 3/4- as a model analyte, the electrochemically induced color change of MV was determined initially by measuring its absorbance via a CCD camera coupled to a microscope. Then, smartphone-based detection and RGB analysis were employed to further simplify the sensing scheme. In both methods a linear relationship between the analyte concentration was produced, the quantity of MV generated, and the colorimetric response, yielding a limit of detection of 1.0 μM. Similar responses were also observed in the detection of dopamine and acetaminophen. Further evolution of the device replaced the potentiostat with batteries to control potential, demonstrating the simplicity and portability of the device. Finally, the physical separation of the reporter and analytical cells renders the device competent to detect analytes in different (e.g. non-aqueous) phases, as demonstrated by using the electrochromic behavior of aqueous MV to detect ferrocene in acetonitrile in the analytical cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗