Search NASA⌕ Search

SEARCH · Search NASA

Results for “Antimicrobial activity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

24 records · Page 2

EcAMSat: Small Satellite to Examine E. coli's Response in Microgravity to the Antibiotic Gentamicin

We have successfully flown the EcAMSat (Escherichia coli Antimicrobial Satellite) free-flyer mission. This was a 6U small satellite that autonomously conducted an experiment in low Earth orbit to explore the impact of the space environment on antibiotic resistance in uropathogenic E. coli (UPEC) and the role a particular sigma factor plays in the response. After being held in stasis during transport to orbit, two strains†a wildtype UPEC and an isogenic mutant with a deleted gene that encodes a sigma factor†were grown to stationary phase in a fluidic card inside EcAMSat's payload, then incubated with three concentrations of the antibiotic gentamicin. The payload then administered alamarBlue®, a redox indicator, into all wells of the fluidic card. The cells were then incubated for 144 hours and metabolic activity was measured optically using the payloads' LED and detector system. Data were then telemetered to the ground and compared to a control experiment conducted in an identical satellite in a lab. The results of this experiment will help us better understand important therapeutic targets for treating bacterial infections on Earth and in space. Such targets are particularly relevant to deep-space and long-duration missions where crew may be more susceptible to infection and treatments for them may work differently.

antibiotic↗

EcAMSat: A Small Satellite Flown to Explore the Role a Sigma Factor Plays in E. coli's Response to the Antibiotic Gentamicin

We have successfully flown the EcAMSat (Escherichia coli Antimicrobial Satellite) free-flyer mission. This was a 6U (six unit - CubeSat) small satellite that autonomously conducted an experiment in low Earth orbit to explore the impact of the space environment on antibiotic resistance in uropathogenic E. coli (UPEC) and the role a particular sigma factor plays in the response. After being held in stasis during transport to orbit, two strains - a wildtype UPEC and an isogenic mutant with a deleted gene that encodes a sigma factor - were grown to stationary phase in a fluidic card inside EcAMSat's payload, then incubated with three concentrations of the antibiotic gentamicin. The payload then administered alamarBlue (registered trademark), a redox indicator, into all wells of the fluidic card. The cells were then incubated for 144 hours and metabolic activity was measured optically using the payloads' LED (Light-Emitting Diode) and detector system. Data were then telemetered to the ground and compared to a control experiment conducted in an identical satellite in a lab. The results of this experiment will help us better understand important therapeutic targets for treating bacterial infections on Earth and in space. Such targets are particularly relevant to deep-space and long-duration missions where crew may be more susceptible to infection and treatments for them may work differently.

small satellite↗

ISS Internal Active Thermal Control System (IATCS) Coolant Remediation Project

The IATCS coolant has experienced a number of anomalies in the time since the US Lab was first activated on Flight 5A in February 2001. These have included: 1) a decrease in coolant pH, 2) increases in inorganic carbon, 3) a reduction in phosphate buffer concentration, 4) an increase in dissolved nickel and precipitation of nickel salts, and 5) increases in microbial concentration. These anomalies represent some risk to the system, have been implicated in some hardware failures and are suspect in others. The ISS program has conducted extensive investigations of the causes and effects of these anomalies and has developed a comprehensive program to remediate the coolant chemistry of the on-orbit system as well as provide a robust and compatible coolant solution for the hardware yet to be delivered. The remediation steps include changes in the coolant chemistry specification, development of a suite of new antimicrobial additives, and development of devices for the removal of nickel and phosphate ions from the coolant. This paper presents an overview of the anomalies, their known and suspected system effects, their causes, and the actions being taken to remediate the coolant.

Morrison, Russell H.↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to their unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade state-of-the-art filtration media currently used in space vehicles with water recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early Life-Support-Systems investigation pioneers in graphene research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and bacterial reduction are probed. This preliminary investigation informs on the practicality of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

Schlegel, Todd T.↗

Development of an Antimicrobial Susceptibility Testing Method Suitable for Performing During Space Flight

Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control (normal gravity) MIC values will be generated by simultaneous inoculation and incubation of a second set of test cards in a laboratory at the launch site. This procedure can provide a safe and compact experiment that should yield new information on the affects of microgravity on the biological activities of various classes of antibiotics.

Jorgensen, James H.↗