Search NASA⌕ Search

SEARCH · Search NASA

Results for “Argon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Status of Measuring Cross Sections of Hadrons on Argon with ProtoDUNE-SP

ProtoDUNE Single-Phase is a 700-ton liquid argon detector operated in the CERN Neutrino Platform from 2018 to 2020. It is part of the Deep Underground Neutrino Experiment (DUNE), a long-baseline neutrino oscillation experiment with a 40 kT liquid argon far detector to be built at the Sanford Underground Research Facility and a near detector, with both argon and non-argon detector technologies, to be hosted at the Fermi National Accelerator Laboratory. A critical uncertainty to understand in the neutrino oscillation program of DUNE is the uncertainty on final state interactions, either reaction or elastic, of various hadrons on argon since the scattering of neutrino-induced hadrons off argon bias the hadron's measured energy. It can also prevent algorithms from identifying the hadron's particle type. Protons, kaons, and pions from the beam are especially important for the DUNE neutrino program as they represent common final state particles in neutrino interactions off a nucl eus. Therefore, ProtoDUNE is analyzing the test beam data to measure cross sections of pions, protons, and kaons on argon, aiming to tune parameters that model charged particle scattering off argon. This talk will discuss the data-taking program for ProtoDUNE and an overview of the status and results of measuring cross sections of pions, protons, and kaons on argon. It will conclude with a brief overview of how these measurements can be used for future liquid argon neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-Radioactivity Argon for Rare-Event Searches

39Ar and 42Ar produce irreducible backgrounds for several argon-based dark matter and neutrino experiments. The use of low-radioactivity underground argon (UAr) could be a solution to the problem. The DarkSide-50 experiment demonstrated that argon derived from underground sources can contain a much lower concentration of 39Ar than atmospheric argon. Following this success, the Global Argon Dark Matter Collaboration (GADMC) is procuring hundreds of tons of UAr for the DarkSide-20k detector. To serve the broader community need, it is increasingly important to identify new sources of low-radioactivity argon. In addition, understanding the underground production mechanisms of argon radioisotopes and devising methods to measure them at ultra-low levels is necessary. The use of low-radioactivity argon could be crucial to expanding the physics goals and sensitivity of next-generation large-scale argon-based experiments.

Radioargon isotopes, Underground argon, Isotope pr↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas electroluminescence in a dual phase xenon-doped argon detector

Noble element detectors using argon or xenon as the detection medium are widely used in the searches for rare neutrino and dark matter interactions. Xenon doping in liquid argon can preserve attractive properties of an argon target while enhancing the detectable signals with properties of xenon. Here, in this work, we deployed a dual-phase liquid argon detector with up to 4% xenon doping in the liquid and studied its gas electroluminescence properties as a function of xenon concentration. At ∼2% xenon doping in liquid argon, we measured ∼34 ppm of xenon in the gas and observed ∼2.5 times larger electroluminescence signals using vacuum ultraviolet silicon photomultipliers than those in pure argon. Analysis of signals of different wavelengths confirms that the argon gas electroluminescence process is strongly modified by the addition of xenon. We propose an analytical model to describe the underlying energy transfer mechanism in argon-xenon gas mixtures. Lastly, the implications of this measurement for low-energy ionization signal detection will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating the ProtoDUNE-SP Detector Performance to Measure a 6 GeV/c Positive Kaon Inelastic Cross Section on Argon

The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of exclusive 𝜋 + -argon interactions using ProtoDUNE-SP

We present the measurement of 𝜋 + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident 𝜋 + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of 𝜋 + -argon secondary interactions within the liquid argon. This is the first measurement of 𝜋 + -argon absorption at this kinetic energy range as well as the first ever measurement of 𝜋 + -argon charge exchange.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermodynamic stability of xenon-doped liquid argon detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we analyze the causes of these instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with $\mathscr{O}$ (1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. In conclusion, this work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the mean excitation energy of liquid argon

Current and future experiments need to know the stopping power of liquid argon. It is used directly in calibration, where commonly the minimum-ionizing portion of muon tracks is used as a standard candle. Similarly, muon range is used as a measure of muon energy. More broadly, the stopping power figures into the simulation of all charged particles, and so uncertainty propagates widely throughout data analysis of all sorts. The main parameter that controls stopping power is the mean excitation energy, or I-value. Experimental information for argon's I-value come primarily from measurements of gaseous argon, with a very limited amount of information from solid argon, and none from liquid argon. These measurements are reviewed, along with a discussion of the difference in central value and uncertainty incurred by the difference of phase. The values newly recommended by this note are $(188 \pm 6)$ eV for gaseous argon and $(197 \pm 8)$ eV for liquid argon (68% C.L. in each case).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tissue gas and blood analyses of human subjects breathing 80% argon and 20% oxygen

Eight human volunteers, individually studied in a hyperbaric chamber, breathed: (1) air at 1 ATA; (2) 80% argon and 20% oxygen at 1 ATA for 30 min; (3) air at 1 ATA for 30 min; (4) 100% O2 at 1 ATA for 30 min; (5) air at 1 ATA for 30 min; (6) 100% O2 at 2 ATA for 60 min; and (7) 80% argon and 20% oxygen at 1 ATA for 30 min. Oxygen, carbon dioxide, nitrogen, and argon tensions were measured in muscle and subcutaneous tissue by mass spectroscopic analyses. Venous blood obtained at regular intervals was analyzed for coagulation and fibrinolytic factors. Inert gas narcosis was not observed. After breathing argon for 30 min, muscle argon tensions were almost three times the subcutaneous tensions. Argon wash-in mirrored nitrogen wash-out. Argon wash-in and wash-out had no effect on tissue PO2 or PCO2. Coagulation and fibrinolytic changes usually associated with vascular bubbles were absent.

Horrigan, D. J.↗

Study of argon expulsion from the post-disruption runaway electron plateau following low-Z massive gas injection in DIII-D

Herein, a 1D radial diffusion model is developed to study the observed rapid expulsion of argon from the runaway electron plateau in the DIII-D tokamak following secondary massive low-Z (D 2 or He) gas injection. The expulsion of argon is found to be caused by further cooling of the background plasma due to the added neutrals, accompanied by recombination of argon ions and greatly increased outward radial transport rate of argon (now dominantly in neutral form) out of the runaway electron beam. After argon expulsion, power loss out of the runaway electron plateau is found to be dominated by neutral transport to the wall (rather than by radiation); this result resolves the power balance discrepancy highlighted in previous work on argon expulsion out of the runaway electron plateau.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗