Search NASA⌕ Search

SEARCH · Search NASA

Results for “Asset monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Clean Energy Cybersecurity Accelerator: Cohort 2 - runZero Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator™ (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - Asimily Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator (TM) (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensing Service Transformer Secondary Currents using Planar Magnetic Pick-up Coils

The rapid deployment of distributed energy resources (DERs) is creating stresses on utility assets in the distribution networks. The service transformer, which is the most commonly used utility asset is often not monitored, since the cost of available sensing solutions is as high as the transformer itself. This paper presents a method to use an array of printed circuit board coils to intelligently monitor North American pole top service transformers. The approach, uses a novel, self-calibrating algorithm to infer the fixed geometry of the installation, by recording data over an extended period of time. The proposed method can enable rapid installation of a non-intrusive sensor that can be used to monitor loading levels of the distribution transformer. Furthermore, these sensors can help in planning, prognostics and advanced situational awareness for utilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote monitoring system

A remote monitoring system for monitoring parameters of an underground asset, such as an electric cable system, a pipeline serving as a conduit for water, gas, oil, sewage, or the like. Parameter detectors, such as sensors that measure temperature, voltage, current, moisture, etc., are distributed along the asset to provide electrical signals that represent respective monitored parameters of the asset. An underground hub disposed in an underground vault, or manhole, through which the asset passes is coupled to the parameter detectors to acquire the signals provided by the parameter detectors. The hub includes a controller to provide data derived from the acquired signals, the data being transmitted to a remote central location by a transceiver, or modem, via LP-WAN communication. Signals from the transceiver are transmitted directly from underground.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly forecasting and early warning generation

The example embodiments are directed to a system and method for forecasting anomalies in feature detection. In one example, the method includes storing feature behavior information of at least one monitoring node of an asset, including a normalcy boundary identifying normal feature behavior and abnormal feature behavior for the at least one monitoring node in feature space, receiving input signals from the at least one monitoring node of the asset and transforming the input signals into feature values in the feature space, wherein the feature values are located within the normalcy boundary, forecasting that a future feature value corresponding to a future input signal from the at least one monitoring node is going to be positioned outside the normalcy boundary based on the feature values within the normalcy boundary, and outputting information concerning the forecasted future feature value being outside the normalcy boundary for display.

Abbaszadeh, Masoud↗

Dynamic, resilient virtual sensing system and shadow controller for cyber-attack neutralization

An industrial asset may have monitoring nodes (e.g., sensor or actuator nodes) that generate current monitoring node values. An abnormality detection and localization computer may receive the series of current monitoring node values and output an indication of at least one abnormal monitoring node that is currently being attacked or experiencing a fault. An actor-critic platform may tune a dynamic, resilient state estimator for a sensor node and output tuning parameters for a controller that improve operation of the industrial asset during the current attack or fault. The actor-critic platform may include, for example, a dynamic, resilient state estimator, an actor model, and a critic model. According to some embodiments, a value function of the critic model is updated for each action of the actor model and each action of the actor model is evaluated by the critic model to update a policy of the actor-critic platform.

Roychowdhury, Subhrajit↗

Dynamic, resilient sensing system for automatic cyber-attack neutralization

An industrial asset may have monitoring nodes that generate current monitoring node values. An abnormality detection computer may determine that an abnormal monitoring node is currently being attacked or experiencing fault. A dynamic, resilient estimator constructs, using normal monitoring node values, a latent feature space (of lower dimensionality as compared to a temporal space) associated with latent features. The system also constructs, using normal monitoring node values, functions to project values into the latent feature space. Responsive to an indication that a node is currently being attacked or experiencing fault, the system may compute optimal values of the latent features to minimize a reconstruction error of the nodes not currently being attacked or experiencing a fault. The optimal values may then be projected back into the temporal space to provide estimated values and the current monitoring node values from the abnormal monitoring node are replaced with the estimated values.

97 MATHEMATICS AND COMPUTING↗

Virtual sensor supervised learning for cyber-attack neutralization

An industrial asset may have monitoring nodes that generate current monitoring node values. A dynamic, resilient estimator may split a temporal monitoring node space into normal and one or more abnormal subspaces associated with different kinds of attack vectors. According to some embodiments, a neutralization model is constructed and trained for each attack vector using supervised learning and the associated abnormal subspace. In other embodiments, a single model is created using out-of-range values for abnormal monitoring nodes. Responsive to an indication of a particular abnormal monitoring node or nodes, the system may automatically invoke the appropriate neutralization model to determine estimated values of the particular abnormal monitoring node or nodes (e.g., by selecting the correct model or using out-of-range values). The series of current monitoring node values from the abnormal monitoring node or nodes may then be replaced with the estimated values.

97 MATHEMATICS AND COMPUTING↗

Integrated behavior-based infrastructure command validation

A cybersecurity infrastructure command validation system is provided herein for validating asset commands issued within an infrastructure network. The cybersecurity infrastructure command validation system can be integrated into an infrastructure network to monitor and validate infrastructure asset commands in real-time or while the infrastructure network is active. The cybersecurity infrastructure command validation system can receive or intercept commands issued by asset controllers. The cybersecurity infrastructure command validation system can validate the commands based on a command validation model. The command validation model can represent normal operating behavior of the infrastructure network. The cybersecurity infrastructure command validation system can provide valid commands to the intended infrastructure asset, or can reject invalid commands. The cybersecurity infrastructure command validation system can store validation results for use in updating the command validation model. The cybersecurity infrastructure command validation system can flag or otherwise warn the infrastructure network or administrators of invalid commands.

Akyol, Bora A.↗

Reliability modeling in a predictive maintenance context: A margin-based approach

Current system reliability methods (typically based on fault trees or reliability block diagrams) can effectively propagate reliability data from the asset to the system level in order to identify system critical points. However, employed asset reliability data are an approximated integral representation of the past industrywide operational experience, and they neglect the present asset health status (available, for example, from online monitoring data and diagnostic assessments) and forecasted health projection (when available from prognostic models). Asset health should be informed solely by that specific asset’s current and historical performance data and should not be an approximated integral representation of the past industrywide operational experience (as currently performed by system reliability models through Bayesian updating processes). Sensor data, diagnostic assessments, and prognostic assessments are in fact not considered in plant reliability models used to inform system engineers on the most critical assets. In addition, the propagation of quantitative health data from the asset to the system level is a challenge given the diverse nature and structure of health data elements (e.g., vibration spectra, temperature readings, expected failure time). Ideally, in a predictive maintenance context, system reliability models should support decision making by propagating available health information from the asset to the system level in order to provide a quantitative snapshot of system health and identify the most critical assets. Here, this paper is directly addressing these two goals by proposing a different approach for reliability modeling that relies on asset diagnostic and prognostic assessments, along with monitoring data to measure asset health. The propagation of health data from the asset to the system level is performed through fault tree models not in probability terms, but in terms of margin where margin is the “distance” between the present status and an undesired event (e.g., failure or unacceptable performance). Through a cause-effect lens, while classical reliability models target the effect associated with asset performance, a margin-based approach focuses on the cause of an undesired asset performance (i.e., its health). Hence, thinking of reliability in terms of margins implies decision-making based on causal reasoning. We will show how fault tree models can be solved using a margin language and how this process can effectively assist system engineers to identify the most critical assets.

97 - MATHEMATICS AND COMPUTING↗

Battery Monitoring System

The component that is powered by the battery pack being monitored is a valuable asset and must be in working condition at all times. Battery chemistry and characteristics have a major role in how to evaluate the state of the battery. The battery monitoring system has many parts that lead to an accurate battery reading. The components consist of a coulomb counting device, end of life voltage detection, a consideration of use for a real-time clock (RTC), temperature sensor, and non-volatile random-access memory (NVRAM). The combination of these elements allows the monitoring system to be highly reliant. Moving forward a better implementation of the ideas in this paper and further testing should ensure a high-quality battery monitoring system.

25 ENERGY STORAGE↗

Adaptive, self-tuning virtual sensing system for cyber-attack neutralization

An industrial asset may have a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that an abnormal monitoring node is currently being attacked or experiencing a fault. An autonomous, resilient estimator may continuously execute an adaptive learning process to create or update virtual sensor models for that monitoring node. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, a level of neutralization may be automatically determined. The autonomous, resilient estimator may then be dynamically reconfigured to estimate a series of virtual node values based on information from normal monitoring nodes, appropriate virtual sensor models, and the determined level of neutralization. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

Abbaszadeh, Masoud↗

4D electrical resistivity tomography for assessing the influence of vegetation and subsurface moisture on railway cutting condition

Instability of slopes, embankments, and cuttings on the railway network is increasingly prevalent globally. Monitoring vulnerable infrastructure aids in geotechnical asset management, and improvements to transport safety and efficiency. Here, we examine the use of a novel, near-real-time Electrical Resistivity Tomography (ERT) monitoring system for assessing the stability of a railway cutting in Leicestershire, United Kingdom. In 2015, an ERT monitoring system was installed across a relict landslide (grassed) and an area of more stable ground on either side (wooded), to monitor changes in electrical resistivity through time and space, and to assess the influence of different types of vegetation on the stability of transportation infrastructure. Two years of 4-Dimensional ERT monitoring results are presented here, and petrophysical relationships developed in the laboratory are applied to calibrate the resistivity models in order to provide an insight into hydrogeological pathways within a railway cutting. The influence of vegetation type on subsurface moisture pathways and on slope stability is also assessed – here we find that seasonal subsurface changes in moisture content and soil suction are exacerbated by the presence of trees (wooded area). This results in shrink-swell behaviour of the clays comprising the railway cutting, resulting in fissuring and a reduction in shear strength, leading to instability. As such, it is proposed that on slopes comprised of expansive soils, grassed slopes are beneficial for stability. Insights into the use of 4-D ERT for monitoring railway infrastructure gained from this study may be applied to the monitoring of critical geotechnical assets elsewhere.

58 GEOSCIENCES↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

A. Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗