Search NASA⌕ Search

SEARCH · Search NASA

Results for “Astronauts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Recyclable Materials for Resource Constrained Environments

In-space manufacturing exhibits severe limitations in resources as astronauts are only afforded with the materials that are brought on-board the space craft. Consequently, the use of recyclable and re-usable materials is paramount. Researchers at NLR leverage their expertise in polymer and recycling chemistry to develop material systems capable of high performance applications with intentional consideration on multi-life use through chemical recycling, mechanical recycling, bio-degradation, and thermoforming. Disclosed within this poster presentation are highlighted projects that illustrate several recyclable by design material systems that have been developed.

09 BIOMASS FUELS↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Overionized plasma in the supernova remnant Sagittarius A East anchored by XRISM observations

Sagittarius A East is a supernova remnant with a unique surrounding environment, as it is located in the immediate vicinity of the supermassive black hole at the Galactic center, Sagittarius A$^{*}$. The X-ray emission of the remnant is suspected to show features of overionized plasma, which would require peculiar evolutionary paths. We report on the first observation of Sagittarius A East with the X-Ray Imaging and Spectroscopy Mission (XRISM). Equipped with a combination of a high-resolution microcalorimeter spectrometer and a large field-of-view CCD imager, we for the first time resolved the Fe xxv K-shell lines into fine structure lines and measured the forbidden-to-resonance intensity ratio to be $1.39 \pm 0.12$, which strongly suggests the presence of overionized plasma. We obtained a reliable constraint on the ionization temperature just before the transition into the overionization state, of $\gt\! 4\:$keV. The recombination timescale was constrained to be $\lt\! 8 \times 10^{11} \:$cm$^{-3}\:$s. The small velocity dispersion of $109 \pm 6\:$km$\:$s$^{-1}$ indicates a low Fe ion temperature $\lt\! 8\:$keV and a small expansion velocity $\lt\! 200\:$km$\:$s$^{-1}$. The high initial ionization temperature and small recombination timescale suggest that either rapid cooling of the plasma via adiabatic expansion from dense circumstellar material or intense photoionization by Sagittarius A$^{*}$ in the past may have triggered the overionization.

galaxy center↗

Constraining gas motion and non-thermal pressure beyond the core of the Abell 2029 galaxy cluster with XRISM

We report on a detailed spectroscopic study of the gas dynamics and hydrostatic mass bias of the galaxy cluster Abell 2029, utilizing high-resolution observations from XRISM Resolve. Abell 2029, known for its cool core and relaxed X-ray morphology, provides an excellent opportunity to investigate the influence of gas motions beyond the central region. Expanding upon prior studies that revealed low turbulence and bulk motions within the core, our analysis covers regions out to the scale radius $R_{2500}$ (670 kpc) based on three radial pointings extending from the cluster center toward the northern side. We obtain accurate measurements of bulk and turbulent velocities along the line of sight. The results indicate that non-thermal pressure accounts for no more than 2% of the total pressure at all radii, with a gradual decrease outward. The observed radial trend differs from many numerical simulations, which often predict an increase in non-thermal pressure fraction at larger radii. These findings suggest that deviations from hydrostatic equilibrium are small, leading to a hydrostatic mass bias of around 2% across the observed area.

X-rays: galaxies: clusters↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

XRISM/Resolve view of Abell 2319: Turbulence, sloshing, and ICM dynamics

Here, we present results from XRISM/Resolve observations of the core of the galaxy cluster Abell 2319, focusing on its kinematic properties. The intracluster medium (ICM) exhibits temperatures of approximately 8 keV across the core, with a prominent cold front and a high-temperature region (⁠~11 keV) in the north-west. The average gas velocity in the 3' x 4' region around the brightest cluster galaxy (BCG) covered by two Resolve pointings is consistent with that of the BCG to within 40 km s -1 ⁠ and we found modest average velocity dispersion of 230–250 km s -1 ⁠. On the other hand, spatially resolved spectroscopy reveals interesting variations. A blueshift of up to ~230 km s -1 ⁠ is observed around the east edge of the cold front, where the gas with the lowest specific entropy is found. The region further south inside the cold front shows only a small velocity difference from the BCG; however, its velocity dispersion is enhanced to ~400 km s -1 ⁠, implying the development of turbulence. These characteristics indicate that we are observing sloshing motion with some inclination angle following BCG and that gas phases with different specific entropy participate in sloshing with their own velocities, as expected from simulations. No significant evidence for a high-redshift ICM component associated with the subcluster Abell 2319B was found in the region covered by the current Resolve pointings. These results highlight the importance of sloshing and turbulence in shaping the internal structure of Abell 2319. Further deep observations are necessary to better understand the mixing and turbulent processes within the cluster.

Astronomy and AstroPhysics↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Spectroscopic diagnostics of high-temperature plasma in stellar coronae using Fe XXIV-XXIV K-shell lines with XRISM

The RS CVn type binary star GT Muscae was observed during its quiescence using the Resolve X-ray microcalorimeter spectrometer onboard XRISM. The main and satellite lines of the Fe XXIV-XXIV K-shell transitions were resolved for the first time from stellar sources. We conducted line ratio analysis to investigate any deviations from collisional ionization equilibrium and Maxwell electron energy distribution with a single temperature. By using five combinations of direct excitation lines and dielectronic recombination satellite lines in three line complexes (Fe He$\alpha$, Ly$\alpha$, and He$\beta$), we found that the plasma is well characterized by two-temperature thermal plasmas with temperatures of 1.7 and 4.3 keV, which is consistent with thermal broadening of Fe xxv, and the broad-band fitting results in the 1.7–10 keV band. Other forms of deviation from a single-temperature plasma, such as different ionization and electron temperatures or the $\kappa$ distribution for the electron energy distributions, are not favored, which is reasonable for stellar coronae at quiescence. This study demonstrates the utility of the Fe K-shell line ratio diagnostics to probe plasma conditions using X-ray microcalorimeters.

X-rays: stars↗

XRISM spectroscopy on orbital modulation of Fe Ly α lines in Cygnus X-3

To understand physical processes such as mass transfer and binary evolution in X-ray binaries, the orbital parameters of the system are fundamental and crucial information. Cygnus X-3 is a high-mass X-ray binary composed of a compact object of unknown nature and a Wolf–Rayet star, which is of great interest in the context of wind-fed mass accretion and binary evolution. Here we present XRISM/Resolve high-resolution spectroscopy, focusing on the Fe Ly$\alpha$ lines when the source was in its hypersoft state. We perform an orbital phase-resolved spectral analysis of the lines to study the orbital modulation of the emission and absorption lines. It is found that the emission lines reflect the orbital motion of the compact object whose estimated velocity amplitude is $430^{+150}_{-140}$ km s$^{-1}$, while the absorption lines show a variation that can be interpreted as originating from the stellar wind. We discuss possible mass ranges for the binary components using the mass function with the estimated value of the velocity amplitude in this work, combined with the relation between the mass-loss rate and the orbital period derivative and the empirical mass and mass-loss rate relation for Galactic Wolf–Rayet stars. They are constrained to be (1.3–5.1) and (9.3–12) M$_\odot$, respectively, for the assumed inclination angle of $i =25^\circ$, and become more relaxed, (1.3–24) and (9.3–16) M$_\odot$, for $i = 35^\circ$. Thus, it remains unclear whether the system harbors a black hole or a neutron star.

X-rays: binaries↗

Resonant scattering at the center of the galaxy cluster PKS 0745-191 with XRISM

We report evidence of the resonant scattering effect at the center of the galaxy cluster PKS 0745-191 with XRISM. We analyzed XRISM/Resolve commissioning-phase observations of the distant cluster PKS 0745-191 ($z = 0.103$) with a $54$ ks exposure. The gain drift was corrected using the onboard modulated X-ray source (MXS), and spectra were extracted from all the pixels that were well illuminated by MXS, the core region (four central pixels, $\sim$100 kpc), and the surrounding region. A single-temperature collisional ionization equilibrium (CIE) model fits the full field-of-view spectrum with $kT \approx 6$ keV and a turbulent velocity of ${\approx}120$ km s$^{-1}$. From the core ($r < 50$ kpc) spectrum, we detected a ${\approx}22\%$ suppression of the Fe xxv He$\alpha$ resonance (w) line relative to the CIE prediction. We performed a Monte Carlo simulation to calculate the resonant scattering (RS) effect using radial profiles from Chandra data. The RS-inferred turbulence agrees with that by Resolve line-broadening, demonstrating that RS provides an independent and consistent constraint on ICM turbulence. These results highlight XRISM/Resolve’s potential for turbulence studies in galaxy clusters.

Astronomy and AstroPhysics↗