Search NASA⌕ Search

SEARCH · Search NASA

Results for “Audio Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

dCache - Joining the noWORM Storage Club

For over a decade, dCache.ORG has provided robust software, called dCache, that is used at more than 80 universities and research institutes around the world, allowing these sites to provide reliable storage services for the WLCG experiments and many other scientific communities. The flexible architecture of dCache allows running it in a wide variety of configurations and platforms - from all-in-one Raspberry-Pi up to hundreds of nodes in multi-petabyte infrastructures. The life cycle of scientific data is well defined - collected, processed, archived and finally deleted, when it’s not needed anymore. Moreover, during all those stages the data is never modified: either the original data is used, or new derived data is produced. With this knowledge, dCache was designed to handle immutable files as efficiently as possible. Data replication, HSM connectivity and data-server independent operations are only possible due to the immutable nature of stored data. Nowadays many commercial vendors provide such write-once-read-many or WORM storage systems, as they become more and more demanded with grown demand of audio, photo and video content in the web. On the other hand by providing standard NFSv4.1 interface dCache is often used as a general-purpose file-system, especially by new communities, like photon scientists or microbiologists. Although many users are aware of data immutability, some applications and use cases still require in-place updates of stored files. To satisfy new requirements some fundamental changes have to be applied to dCache’s core design. However, new developments must not compromise any aspect of existing functionality. In this presentation we will show new developments in dCache to turn it into a regular file system. We will discuss the challenges to build a distributed storage system, ‘life’ with POSIX compliance, handling of multiple replicas and backward compatibility by providing WORM and noWORM capabilities within the same storage system.

Mkrtchyan, Tigran↗

Speech information retrieval: a review

Audio is an information-rich component of multimedia. Information can be extracted from audio in a number of different ways, and thus there are several established audio signal analysis research fields. These fields include speech recognition, speaker recognition, audio segmentation and classification, and audio finger-printing. The information that can be extracted from tools and methods developed in these fields can greatly enhance multimedia systems. In this paper, we present the current state of research in each of the major audio analysis fields. The goal is to introduce enough back-ground for someone new in the field to quickly gain high-level understanding and to provide direction for further study.

Hafen, Ryan P↗

Retrospective Analysis of Clinical Performance of an Estonian Speech Recognition System for Radiology: Effects of Different Acoustic and Language Models

The aim of this study was to analyze retrospectively the influence of different acoustic and language models in order to determine the most important effects to the clinical performance of an Estonian language-based non-commercial radiology-oriented automatic speech recognition (ASR) system. An ASR system was developed for Estonian language in radiology domain by utilizing open-source software components (Kaldi toolkit, Thrax). The ASR system was trained with the real radiology text reports and dictations collected during development phases. The final version of the ASR system was tested by 11 radiologists who dictated 219 reports in total, in spontaneous manner in a real clinical environment. The audio files collected in the final phase were used to measure the performance of different versions of the ASR system retrospectively. ASR system versions were evaluated by word error rate (WER) for each speaker and modality and by WER difference for the first and the last version of the ASR system. Total average WER for the final version throughout all material was improved from 18.4% of the first version (v1) to 5.8% of the last (v8) version which corresponds to relative improvement of 68.5%. WER improvement was strongly related to modality and radiologist. In summary, the performance of the final ASR system version was close to optimal, delivering similar results to all modalities and being independent on user, the complexity of the radiology reports, user experience, and speech characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Audio-Visual Biofeedback Does Not Improve the Reliability of Target Delineation Using Maximum Intensity Projection in 4-Dimensional Computed Tomography Radiation Therapy Planning

Purpose: To investigate whether coaching patients' breathing would improve the match between ITV{sub MIP} (internal target volume generated by contouring in the maximum intensity projection scan) and ITV{sub 10} (generated by combining the gross tumor volumes contoured in 10 phases of a 4-dimensional CT [4DCT] scan). Methods and Materials: Eight patients with a thoracic tumor and 5 patients with an abdominal tumor were included in an institutional review board-approved prospective study. Patients underwent 3 4DCT scans with: (1) free breathing (FB); (2) coaching using audio-visual (AV) biofeedback via the Real-Time Position Management system; and (3) coaching via a spirometer system (Active Breathing Coordinator or ABC). One physician contoured all scans to generate the ITV{sub 10} and ITV{sub MIP}. The match between ITV{sub MIP} and ITV{sub 10} was quantitatively assessed with volume ratio, centroid distance, root mean squared distance, and overlap/Dice coefficient. We investigated whether coaching (AV or ABC) or uniform expansions (1, 2, 3, or 5 mm) of ITV{sub MIP} improved the match. Results: Although both AV and ABC coaching techniques improved frequency reproducibility and ABC improved displacement regularity, neither improved the match between ITV{sub MIP} and ITV{sub 10} over FB. On average, ITV{sub MIP} underestimated ITV{sub 10} by 19%, 19%, and 21%, with centroid distance of 1.9, 2.3, and 1.7 mm and Dice coefficient of 0.87, 0.86, and 0.88 for FB, AV, and ABC, respectively. Separate analyses indicated a better match for lung cancers or tumors not adjacent to high-intensity tissues. Uniform expansions of ITV{sub MIP} did not correct for the mismatch between ITV{sub MIP} and ITV{sub 10}. Conclusions: In this pilot study, audio-visual biofeedback did not improve the match between ITV{sub MIP} and ITV{sub 10}. In general, ITV{sub MIP} should be limited to lung cancers, and modification of ITV{sub MIP} in each phase of the 4DCT data set is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Audio Coaching on Correlation of Abdominal Displacement With Lung Tumor Motion

Purpose: To assess the effect of audio coaching on the time-dependent behavior of the correlation between abdominal motion and lung tumor motion and the corresponding lung tumor position mismatches. Methods and Materials: Six patients who had a lung tumor with a motion range >8 mm were enrolled in the present study. Breathing-synchronized fluoroscopy was performed initially without audio coaching, followed by fluoroscopy with recorded audio coaching for multiple days. Two different measurements, anteroposterior abdominal displacement using the real-time positioning management system and superoinferior (SI) lung tumor motion by X-ray fluoroscopy, were performed simultaneously. Their sequential images were recorded using one display system. The lung tumor position was automatically detected with a template matching technique. The relationship between the abdominal and lung tumor motion was analyzed with and without audio coaching. Results: The mean SI tumor displacement was 10.4 mm without audio coaching and increased to 23.0 mm with audio coaching (p < .01). The correlation coefficients ranged from 0.89 to 0.97 with free breathing. Applying audio coaching, the correlation coefficients improved significantly (range, 0.93-0.99; p < .01), and the SI lung tumor position mismatches became larger in 75% of all sessions. Conclusion: Audio coaching served to increase the degree of correlation and make it more reproducible. In addition, the phase shifts between tumor motion and abdominal displacement were improved; however, all patients breathed more deeply, and the SI lung tumor position mismatches became slightly larger with audio coaching than without audio coaching.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Low-Cost Approach for Acquiring High Resolution High-Speed Data

The Oak Ridge National Laboratory (ORNL) has developed and tested a novel system architecture for acquiring high fidelity high-speed data. The approach uses a low-cost consumer grade audio recording device coupled with computing technology running open-source software. The main advantage of this approach is perchannel cost; an instrument grade data acquisition system typically costs between $800 to $2,000 per channel compared to less than $50 per channel for these consumer grade components. Three systems, each featuring four channels, have been deployed for acquiring data from geophones and the electrical supply system that supports the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC) at ORNL. Each channel samples at 96 kHz at 24-bit resolution. The deployed systems operate continuously 24/7 and produce about 4 terabytes of data per month per system. This paper provides a technical overview of this approach, its implementation, and some preliminary results from qualification testing. This work was conducted in support of the Multi-Informatics for Nuclear Operations Scenarios (MINOS).

Wetherington Jr, G↗

Using Low-Cost “Garage Band” Recording Technology for Acquiring High Resolution High-Speed Data

The Oak Ridge National Laboratory (ORNL) has developed and tested a novel system architecture for acquiring high fidelity high-speed data. The approach uses a consumer grade audio recording device that is normally associated with “garage band” recording of music. ORNL has coupled this low-cost data acquisition hardware with computing technology running open-source software. The main advantage of this approach is per-channel cost; an instrument grade data acquisition system typically costs between $800 to $2000 per channel compared to less than $50 per channel for these consumer grade components. Three systems, each featuring four channels, have been deployed for acquiring data from geophones and the electrical supply system that supports the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC) at ORNL. Each channel samples at 96 kHz at 24-bit resolution. The deployed systems operate continuously 24/7 and produce about 4 terabytes of data per month per system. This paper provides a technical overview of this approach, its implementation, and some preliminary results from qualification testing. This work was conducted in support of the Multi-Informatics for Nuclear Operations Scenarios (MINOS).Keywords: Data acquisition Measurement Informatics

Wetherington Jr, G↗

Management of the baseline shift using a new and simple method for respiratory-gated radiation therapy: Detectability and effectiveness of a flexible monitoring system

Purpose: In respiratory-gated radiation therapy, a baseline shift decreases the accuracy of target coverage and organs at risk (OAR) sparing. The effectiveness of audio-feedback and audio-visual feedback in correcting the baseline shift in the breathing pattern of the patient has been demonstrated previously. However, the baseline shift derived from the intrafraction motion of the patient's body cannot be corrected by these methods. In the present study, the authors designed and developed a simple and flexible system. Methods: The system consisted of a web camera and a computer running our in-house software. The in-house software was adapted to template matching and also to no preimage processing. The system was capable of monitoring the baseline shift in the intrafraction motion of the patient's body. Another marker box was used to monitor the baseline shift due to the flexible setups required of a marker box for gated signals. The system accuracy was evaluated by employing a respiratory motion phantom and was found to be within AAPM Task Group 142 tolerance (positional accuracy <2 mm and temporal accuracy <100 ms) for respiratory-gated radiation therapy. Additionally, the effectiveness of this flexible and independent system in gated treatment was investigated in healthy volunteers, in terms of the results from the differences in the baseline shift detectable between the marker positions, which the authors evaluated statistically. Results: The movement of the marker on the sternum [1.599 {+-} 0.622 mm (1 SD)] was substantially decreased as compared with the abdomen [6.547 {+-} 0.962 mm (1 SD)]. Additionally, in all of the volunteers, the baseline shifts for the sternum [-0.136 {+-} 0.868 (2 SD)] were in better agreement with the nominal baseline shifts than was the case for the abdomen [-0.722 {+-} 1.56 mm (2 SD)]. The baseline shifts could be accurately measured and detected using the monitoring system, which could acquire the movement of the marker on the sternum. The baseline shift-monitoring system with the displacement-based methods for highly accurate respiratory-gated treatments should be used to make most of the displacement-based gating methods. Conclusions: The advent of intensity modulated radiation therapy and volumetric modulated radiation therapy facilitates margin reduction for the planning target volumes and the OARs, but highly accurate irradiation is needed to achieve target coverage and OAR sparing with a small margin. The baseline shifts can affect treatment not only with the respiratory gating system but also without the system. Our system can manage the baseline shift and also enables treatment irradiation to be undertaken with high accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high-fidelity residential building occupancy detection dataset

Abstract This paper describes development of a data acquisition system used to capture a range of occupancy related modalities from single-family residences, along with the dataset that was generated. The publicly available dataset includes: grayscale images at 32-by-32 pixels, captured every second; audio files, which have undergone processing to remove personally identifiable information; indoor environmental readings, captured every ten seconds; and ground truth binary occupancy status. The data acquisition system, coined the mobile human presence detection (HPDmobile) system, was deployed in six homes for a minimum duration of one month each, and captured all modalities from at least four different locations concurrently inside each home. The environmental modalities are available as captured, but to preserve the privacy and identity of the occupants, images were downsized and audio files went through a series of processing steps, as described in this paper. This dataset adds to a very small body of existing data, with applications to energy efficiency and indoor environmental quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of Several Low-Cost Consumer-Grade Analog-to-Digital Conversion Devices

The Oak Ridge National Laboratory (ORNL) has pioneered an approach where low-cost consumer-grade electronics can be used as the basis of a highly reliable data acquisition architecture. One twenty-channel system based on this approach has been operating almost 4 years at ORNL. The architecture allows a mix-and-match level of configurability so the designer can select devices that best match the desired performance trade-offs. The most important device to be selected is the analog-to-digital converter. This paper explores the performance of several candidate audio recording devices that can be used as high-speed analog-to-digital converters for such measurement systems. Various performance metrics are explored including frequency response, noise floor, and synchronous sampling. Sample rates as high as 192 KHz are supported with 16 and 24-bit resolution. While most of the devices are dual-channel, there are multi-channel devices now available that will allow modal type of synchronous sampling. One such device was tested and is discussed is this paper.

Wetherington Jr, G↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

Coastal Acoustic Buoy for Offshore Wind: Project Synthesis

The population of North Atlantic right whales is critically endangered and their habitat overlaps with offshore windfarm leases. It is therefore imperative that effective mitigation strategies be used to avoid impacts on right whales during the construction of offshore windfarms. The Department of Energy issued FOA Number DE-FOA-0001924 to encourage the development of technology that could monitor large exclusion zones for right whales in order to mitigate potential impact of construction noise on right whales. This report summarizes the past two years of the development and evaluation of the Coastal Acoustic Buoy for Offshore Wind (CABOW) project which aimed to develop technology to monitor large exclusion zones for North Atlantic right whales. Over the course of the project SMRU Consulting have implemented a rigorous design process including comparison of different approaches (e.g., single sensor vs multiple sensors), as well as consideration of placement and timing of acoustic monitoring. We have evaluated critical components of the CABOW system including, reliability, detection range, and bearing accuracy in areas adjacent to offshore windfarm leases in Maryland by conducting 3,536 playbacks of simulated right whale upcalls. The maximum call detection range was 7.5 km when noise was 99 dB re 1µPa rms (50-225 Hz), but this reduced to < 1 km when ambient noise levels were high. Our detection probability in the field was measured as a function of range as well as the source-to-noise level ratio allowing us to build a model to predict the probability of detection under various scenarios (sample size: 3,536 calls x 5 buoys = 17,680). The median bearing error was -0.25° but this is likely an underestimate of error due to experimental design. Using the published recall and precision of the two detectors we implemented in the CABOW system, we estimate that at a recall of 80%, our precision was > 80%, within the range of what we were aiming for in this project. To estimate our exclusion zone false negative and false positive rates, we built a simulation model using the empirical data from our field trial. We modelled three to nine CABOW units placed on the 10 km exclusion zone and estimated our false negative rate to be 1% or less (which was our project goal) and our false positive rate to be between seven and nine percent, slightly above our goal of 5%. However, we also modelled an equivalent PAM system that does not have bearing capabilities and found the false positive rates for that system to be six to eight times higher than the CABOW rate. This higher false positive rate of PAM systems with low spatial information could have significant cost repercussions for offshore wind developers by adding work shutdowns or delays without providing additional protection for right whales. The model we built allows us to explore the placement of PAM systems under various scenarios and will thus help facilitate planning of PAM mitigation systems to meet NOAA Incidental Harassment Authorizations for specific windfarms. We achieved an average system uptime of 98.3%, just below our goal of 99%. The issues that caused these short losses of data have been identified and fixed. Right whale detections and audio clips were typically transferred via radio from the buoys to the base station in two to four seconds. We therefore believe we have developed a highly robust real-time PAM system. Based on the above, we feel we have achieved the stated funding goal of developing a cost-effective and robust real-time PAM system that enables the monitoring of large exclusion zones for right whales during the constructions of offshore windfarms. This should lead to decreased costs and risks for the offshore wind sector while providing robust mitigation for right whales. It is important to state that PAM mitigation will need to be implemented with other mitigation strategies (e.g., visual observers) to provide a complete mitigation strategy to ensure that any effects on right whales from offshore windfarm construction is minimized.

17 WIND ENERGY↗

Aquatic Acoustic Metrics Interface

Fishes and marine mammals may suffer a range of potential effects from exposure to intense underwater sound generated by anthropogenic activities such as pile driving, shipping, sonars, and underwater blasting. Several underwater sound recording (USR) devices have been built to acquire samples of the underwater sound generated by anthropogenic activities. Software becomes indispensable for processing and analyzing the audio files recorded by these USRs. The new Aquatic Acoustic Metrics Interface Utility Software (AAMI) is specifically designed for analysis of underwater sound recordings to provide data in metrics that facilitate evaluation of the potential impacts of the sound on aquatic animals. In addition to the basic functions, such as loading and editing audio files recorded by USRs and batch processing of sound files, the software utilizes recording system calibration data to compute important parameters in physical units. The software also facilitates comparison of the noise sound sample metrics with biological measures such as audiograms of the sensitivity of aquatic animals to the sound, integrating various components into a single analytical frame.

Source record↗

System and method of detecting and analyzing a threat in a confined environment

A system and method of detecting and analyzing a threat in a confined environment is disclosed. An audio board detects and analyzes audio signals. A RF board transmits the signals for emergency response. A battery provides power to the audio board and the RF board. The audio board includes a microcontroller with at least one band-pass filter for distinguishing between a threat and a non-threat event and for measuring or counting pulses if the event is a threat.

47 OTHER INSTRUMENTATION↗

Low-cost gradient amplifiers for small MRI systems

Here, we describe low-cost gradient amplifiers for small MRI systems, such as those based on small/medium permanent magnets. The requirements for MRI gradient amplifiers are quite similar to those of modestly priced audio stereo power amplifiers. Such amplifiers for sound service can be modified to be DC coupled, extending their response down to zero frequency, as needed for MRI gradient service. We describe such modifications to one unit (Samson Servo 600) and mention a commercially available modification of another. The 600 is capable of an output greater than ±8 A and ±60 V, much greater than our needs for a greenhouse MRI. Audio amplifiers can be used this way as controlled voltage (CV) gradient amplifiers, with acceptable performance because the gradient coils typically have short L/R time constants. Superior performance can be had by using a controlled current (CC) “front end”; the circuit of our simple front end is included. The complete 3-axis CC system costs about $1200.

47 OTHER INSTRUMENTATION↗