Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automated calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Automated Noise Calibration System (VT-1000)

This paper details an automated Noise Source calibration system in development at Jet Propulsion Laboratory, California Institute of Technology (JPL). The paper begins with a discussion on Noise Figure and Excess Noise Ratio (ENR) theory, fundamentals and governing equations. As part of the fundamentals is a discussion of the system’s use of the Y-factor method to obtain accurate measurements of the Unit Under Test (UUT), and how these measurements are compared against a known ENR standard to obtain the UUT’s ENR values. There is also an in-depth discussion on uncertainty quantification for Noise Source system calibrations. The architecture of the automated calibration system is provided, which includes both the system’s hardware and software configuration. The software is written in Python 3, and provides the user detailed instruction on how to proceed, including step-by-step connection requirements. This system automates much of the measurement process, including real-time uncertainty quantification and report generation, as well as real-time feedback to the user to allow intervention if necessary. The system takes advantage of a database of results from previous measurements to compare calibration history of the ENR measurements. The automated system presented here operates over a frequency range from 10 MHz to 50 GHz, and has shown substantial time savings over traditional manual methods of performing this calibration.

Timpe, Scott↗

Automated Custom Calibration for E3SM

Focal Area(s): Automated custom calibration for the Energy Exascale Earth System Model (E3SM) applies primarily to focal area 2: Predictive modeling through the use of AI techniques, and includes elements of focal area 3: Insight gleaned from complex data (both observed and simulated).

54 ENVIRONMENTAL SCIENCES↗

SSME Automated Engine Calibration System (AECS)

An algorithm is derived for the real-time calibration of the engine fuel flowmeter and the engine mixture ratio during Space Shuttle Main Engine (SSME) ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an Automated Engine Calibration System (AECS) which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

An Advanced Microscopic Energy Consumption Model for Automated Vehicle:Development, Calibration, Verification

The automated vehicle (AV) equipped with the Adaptive Cruise Control (ACC) system is expected to reduce the fuel consumption for the intelligent transportation system. This paper presents the Advanced ACC-Micro (AA-Micro) model, a new energy consumption model based on micro trajectory data, calibrated and verified by empirical data. Utilizing a commercial AV equipped with the ACC system as the test platform, experiments were conducted at the Columbus 151 Speedway, capturing data from multiple ACC and Human-Driven (HV) test runs. The calibrated AA-Micro model integrates features from traditional energy consumption models and demonstrates superior goodness of fit, achieving an impressive 90% accuracy in predicting ACC system energy consumption without overfitting. A comprehensive statistical evaluation of the AA-Micro model's applicability and adaptability in predicting energy consumption and vehicle trajectories indicated strong model consistency and reliability for ACC vehicles, evidenced by minimal variance in RMSE values and uniform RSS distributions. Conversely, significant discrepancies were observed when applying the model to HV data, underscoring the necessity for specialized models to accurately predict energy consumption for HV and ACC systems, potentially due to their distinct energy consumption characteristics.

Ma, Ke↗

Development of a Complete Landsat Evapotranspiration and Energy Balance Archive to Support Agricultural Consumptive Water Use Reporting and Prediction in the Central Valley, CA

Mapping evapotranspiration (ET) from agricultural areas in Californias Central Valley is critical for understanding historical consumptive use of surface and groundwater. In addition, long histories of ET maps provide valuable training information for predictive studies of surface and groundwater demands. During times of drought, groundwater is commonly pumped to supplement reduced surface water supplies in the Central Valley. Due to the lack of extensive groundwater pumping records, mapping consumptive use using satellite imagery is an efficient and robust way for estimating agricultural consumptive use and assessing drought impacts. To this end, we have developed and implemented an algorithm for automated calibration of the METRIC remotely sensed surface energy balance model on NASAs Earth Exchange (NEX) to estimate ET at the field scale. Using automated calibration techniques on the NEX has allowed for the creation of spatially explicit historical ET estimates for the Landsat archive dating from 1984 to the near present. Further, our use of spatial NLDAS and CIMIS weather data, and spatial soil water balance simulations within the NEX METRIC workflow, has helped overcome challenges of time integration between satellite image dates. This historical and near present time archive of agricultural water consumption for the Central Valley will be an extremely useful dataset for water use and drought impact reporting, and predictive analyses of groundwater demands.

valleys↗

Adaptive Cognitive Mechanisms to Maintain Calibrated Trust and Reliance in Automation

Trust calibration for a human–machine team is the process by which a human adjusts their expectations of the automation’s reliability and trustworthiness; adaptive support for trust calibration is needed to engender appropriate reliance on automation. Herein, we leverage an instance-based learning ACT-R cognitive model of decisions to obtain and rely on an automated assistant for visual search in a UAV interface. This cognitive model matches well with the human predictive power statistics measuring reliance decisions; we obtain from the model an internal estimate of automation reliability that mirrors human subjective ratings. The model is able to predict the effect of various potential disruptions, such as environmental changes or particular classes of adversarial intrusions on human trust in automation. Finally, we consider the use of model predictions to improve automation transparency that account for human cognitive biases in order to optimize the bidirectional interaction between human and machine through supporting trust calibration. The implications of our findings for the design of reliable and trustworthy automation are discussed.

60 APPLIED LIFE SCIENCES↗

Orbital Express AVGS Validation and Calibration for Automated Rendezvous

From March to July of 2007, the DARPA Orbital Express mission achieved a number of firsts in autonomous spacecraft operations. The NASA Advanced Video Guidance Sensor (AVGS) was the primary docking sensor during the first two dockings and was used in a blended mode three other automated captures. The AVGS performance exceeded its specification by approximately an order of magnitude. One reason that the AVGS functioned so well during the mission was that the validation and calibration of the sensor prior to the mission advanced the state-of-the-art for proximity sensors. Some factors in this success were improvements in ground test equipment and truth data, the capability for ILOAD corrections for optical and other effects, and the development of a bias correction procedure. Several valuable lessons learned have applications to future proximity sensors.

Heaton, Andrew F.↗

SSME Automated Engine Calibrating System (AECS) alternative algorithm

An algorithm is derived for the real-time calibration of the engine mixture ratio during SSME ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an AECS which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. This algorithm is an alternative to that presented in a previous paper. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with a discussion of a possible single coefficient calibration system and the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Steady-State Vacuum Ultraviolet Exposure Facility With Automated Lamp Calibration and Sample Positioning Fabricated

The Next Generation Space Telescope (NGST) will be placed in an orbit that will subject it to constant solar radiation during its planned 10-year mission. A sunshield will be necessary to passively cool the telescope, protecting it from the Sun s energy and assuring proper operating temperatures for the telescope s instruments. This sunshield will be composed of metalized polymer multilayer insulation with an outer polymer membrane (12 to 25 mm in thickness) that will be metalized on the back to assure maximum reflectance of sunlight. The sunshield must maintain mechanical integrity and optical properties for the full 10 years. This durability requirement is most challenging for the outermost, constantly solar-facing polymer membrane of the sunshield. One of the potential threats to the membrane material s durability is from vacuum ultraviolet (VUV) radiation in wavelengths below 200 nm. Such radiation can be absorbed in the bulk of these thin polymer membrane materials and degrade the polymer s optical and mechanical properties. So that a suitable membrane material can be selected that demonstrates durability to solar VUV radiation, ground-based testing of candidate materials must be conducted to simulate the total 10- year VUV exposure expected during the Next Generation Space Telescope mission. The Steady State Vacuum Ultraviolet exposure facility was designed and fabricated at the NASA Glenn Research Center at Lewis Field to provide unattended 24-hr exposure of candidate materials to VUV radiation of 3 to 5 times the Sun s intensity in the wavelength range of 115 to 200 nm. The facility s chamber, which maintains a pressure of approximately 5 10(exp -6) torr, is divided into three individual exposure cells, each with a separate VUV source and sample-positioning mechanism. The three test cells are separated by a water-cooled copper shield plate assembly to minimize thermal effects from adjacent test cells. Part of the interior sample positioning mechanism of one test cell is shown in the illustration. Of primary concern in VUV exposure is the maintenance of constant measured radiation intensity so that the sample s total exposure can be determined in equivalent Sun hours. This is complicated by the fact that a VUV lamp s intensity degrades over time, necessitating a decrease in the distance between the test samples and the lamp. The facility overcomes this challenge by periodically measuring the lamp s intensity with a cesium-iodide phototube and adjusting the sample distance as required to maintain constant exposure intensity. Sample positioning and periodic phototube location under the lamp are both achieved by a single lead-screw assembly. The lamps can be isolated from the main vacuum chamber for cleaning or replacement so that samples are not exposed to the atmosphere during a test.

Sechkar, Edward A.↗

Fast calibration of gas flowmeters

Digital unit automates calibration sequence using calculator IC and programmable read-only memory to solve calibration equations. Infrared sensors start and stop calibration sequence. Instrument calibrates mass flowmeters or rotameters where flow measurement is based on mass or volume. This automatic control reduces operator time by 80 percent. Solid-state components are very reliable, and digital character allows system accuracy to be determined primarily by accuracy of transducers.

Lisle, R. V.↗

Calibration of parallel bond parameters in bonded particle models via physics-informed adaptive moment optimisation

This study proposes an automated calibration procedure for bond parameters in bonded discrete element modelling. By exploring the underlying physical correlations between microscopic parameters of bonds and macroscopic strength parameters of the continuum to be modelled, the microscopic shear strength and tensile strength are identified as independent variables for calibration purpose. Then a physics-informed iterative scheme is proposed to automatically approximate the bond parameters by viewing the micro-macro relation as an implicitly defined mathematical mapping function. As a result of highly non-convex features of this implicit mapping, the adaptive moment estimation (Adam), which is especially suitable for problems with noisy gradients, is adopted as the basic iterative scheme, in conjunction with other numerical techniques to approximately evaluate the partial derivatives involved. The whole procedure offers a simple and effective framework for bond parameter calibration. Finally, a numerical example of SiC ceramic is provided for validation. By compared with some existing calibration methods, the proposed method shows significant advantages in terms of calibration efficiency and accuracy.

42 ENGINEERING↗

Stepwise Regression Analysis of MDOE Balance Calibration Data Acquired at DNW

This paper reports a comparison of two experiment design methods applied in the calibration of a strain-gage balance. One features a 734-point test matrix in which loads are varied systematically according to a method commonly applied in aerospace research and known in the literature of experiment design as One Factor At a Time (OFAT) testing. Two variations of an alternative experiment design were also executed on the same balance, each with different features of an MDOE experiment design. The Modern Design of Experiments (MDOE) is an integrated process of experiment design, execution, and analysis applied at NASA's Langley Research Center to achieve significant reductions in cycle time, direct operating cost, and experimental uncertainty in aerospace research generally and in balance calibration experiments specifically. Personnel in the Instrumentation and Controls Department of the German Dutch Wind Tunnels (DNW) have applied MDOE methods to evaluate them in the calibration of a balance using an automated calibration machine. The data have been sent to Langley Research Center for analysis and comparison. This paper reports key findings from this analysis. The chief result is that a 100-point calibration exploiting MDOE principles delivered quality comparable to a 700+ point OFAT calibration with significantly reduced cycle time and attendant savings in direct and indirect costs. While the DNW test matrices implemented key MDOE principles and produced excellent results, additional MDOE concepts implemented in balance calibrations at Langley Research Center are also identified and described.

DeLoach, RIchard↗

Automated Attitude Sensor Calibration: Progress and Plans

This paper describes ongoing work a NASA/Goddard Space Flight Center to improve the quality of spacecraft attitude sensor calibration and reduce costs by automating parts of the calibration process. The new calibration software can autonomously preview data quality over a given time span, select a subset of the data for processing, perform the requested calibration, and output a report. This level of automation is currently being implemented for two specific applications: inertial reference unit (IRU) calibration and sensor alignment calibration. The IRU calibration utility makes use of a sequential version of the Davenport algorithm. This utility has been successfully tested with simulated and actual flight data. The alignment calibration is still in the early testing stage. Both utilities will be incorporated into the institutional attitude ground support system.

Sedlak, Joseph↗

An Automated Method for Ozonesonde Calibration: New Insights

An automated method for preparation of the electrochemical concentration cell (ECC) ozonesonde is presented. Development of a computer-controlled system for preparation and calibration of the ECC is an improvement over the manual preparation method, and reduces subjectivity considerably. Preparation measurements in digital form aids analysis of the ECC before release and enhances post-flight data certification. Calibration of ozonesondes over a range of ozone concentrations between 0 mPA and 30 mPA is discussed. This presentation describes the automatic system, gives examples of calibrations. The automated system enables comparison of varying potassium iodide (KI) concentrations that should allow adjustment of earlier ozonesonde data obtained with different KT concentrations used since 1970, i.e., 2, 1.5, 1, and 0.5 percent. Preliminary results indicate ECC accuracy has a strong dependence on the electrolyte concentration and should not be considered linear with altitude.

Schmidlin, F. J.↗

Comparative Analysis of Thrombin Calibration Algorithms and Correction for Thrombin-α2macroglobulin Activity

Background: The thrombin generation (TG) test is useful for characterizing global hemostasis potential, but fluorescence substrate artifacts, such as thrombin-α2macroglobulin (T-α2MG) signal, inner filter effect (IFE), substrate consumption, and calibration algorithms have been suggested as sources of intra- and inter-laboratory variance, which may limit its clinical utility. Methods: Effects of internal vs. external normalization, IFE and T-α2MG on TG curves in normal plasma supplemented with coagulation factors, thrombomodulin, and tissue factor were studied using the Calibrated Automated Thrombinography (CAT; Diagnostica Stago, Parsippany, NJ, USA) and in-house software. Results: The various calibration methods demonstrated no significant difference in producing TG curves, nor increased the robustness of the TG assay. Several TG parameters, including thrombin peak height (TPH), produced from internal linear calibration did not differ significantly from uncalibrated TG parameters. Further, TPH values from internal linear and nonlinear calibration with or without T-α2MG correction correlated well with TPH from external calibration. Higher coefficients of variation (CVs) for TPH values were observed in both platelet-free and platelet-rich plasma with added thrombomodulin. Conclusions: Our work suggests minimal differences between distinct computational approaches toward calibrating and correcting fluorescence signals into TG levels, with most samples returning similar or equivalent TPH results.

59 BASIC BIOLOGICAL SCIENCES↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calibration Test Set for a Phase-Comparison Digital Tracker

An apparatus that generates four signals at a frequency of 7.1 GHz having precisely controlled relative phases and equal amplitudes has been designed and built. This apparatus is intended mainly for use in computer-controlled automated calibration and testing of a phase-comparison digital tracker (PCDT) that measures the relative phases of replicas of the same X-band signal received by four antenna elements in an array. (The relative direction of incidence of the signal on the array is then computed from the relative phases.) The present apparatus can also be used to generate precisely phased signals for steering a beam transmitted from a phased antenna array. The apparatus (see figure) includes a 7.1-GHz signal generator, the output of which is fed to a four-way splitter. Each of the four splitter outputs is attenuated by 10 dB and fed as input to a vector modulator, wherein DC bias voltages are used to control the in-phase (I) and quadrature (Q) signal components. The bias voltages are generated by digital-to-analog- converter circuits on a control board that receives its digital control input from a computer running a LabVIEW program. The outputs of the vector modulators are further attenuated by 10 dB, then presented at high-grade radio-frequency connectors. The attenuation reduces the effects of changing mismatch and reflections. The apparatus was calibrated in a process in which the bias voltages were first stepped through all possible IQ settings. Then in a reverse interpolation performed by use of MATLAB software, a lookup table containing 3,600 IQ settings, representing equal amplitude and phase increments of 0.1 , was created for each vector modulator. During operation of the apparatus, these lookup tables are used in calibrating the PCDT.

Boas, Amy↗

Real-Twin

Real-Twin is a unified, model-agnostic scenario generation tool designed to streamline and standardize the evaluation of emerging mobility technologies. It provides an end-to-end framework that includes robust workflows, integrated tools, and comprehensive metrics to generate, calibrate, and benchmark microscopic traffic simulation scenarios across multiple platforms. Key Features of Real-Twin include: - Unified Scenario Generation: generate transferable, simulation-ready scenarios from heterogeneous data sources using a consistent workflow. - Automated Calibration Workflow: bridges simulation and real-world data, minimizing manual effort and making traffic simulation more accessible to researchers and engineers. - Model-Agnostic Compatibility: supports SUMO, VISSIM, and AIMSUN for cross-platform scenario generation and benchmarking. Enables reliable comparisons and reproducibility across different simulation tools. - Consistent Scenarios across Different Simulators: generate comparable simulation scenarios across different microscopic traffic simulators, providing users the ability to conduct benchmarking and cross-validation that are crucial for ensuring the reliability and reproducibility of simulation results. - Emerging Technology Support: includes a scenario database and pipeline for studying autonomous vehicles (AVs), with planned extensions to CAVs, EVs, and other advanced technologies.

Wang, Chieh (Ross) [Oak Ridge National Laboratory ↗