Search NASA⌕ Search

SEARCH · Search NASA

Results for “BACKUP COMMUNICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

33 records · Page 2

Performance Audit Report: Automated Meteorological Monitoring Stations, Lawrence Livermore National Laboratory

The Waste and Air Quality Offices Group at the Lawrence Livermore National Laboratory operates two main meteorological monitoring sites near Livermore, California. The primary met tower (Site 200) is located in the northwest corner of the lab and consists of a fifty-two (52) meter tower with vertical wind speed sensors, horizontal wind speed and direction sensors and air temperature sensors at fifty-two (52) meters, twenty-three (23) meters and ten (10) meters. In addition, there is a temperature and humidity probe at ten (10) meters. At two (2) meters there are upward and downward facing solar and infrared radiation sensors, an air temperature sensor, barometric pressure sensor and a temperature and relative humidity probe. At ground level there is a tipping bucket rain gauge located to the southwest of the tower. The datalogger, communication peripherals and the barometric pressure sensor are housed in a small building near the tower. The Site 300 met site is located approximately 10 miles east of Livermore within the boundary of the LLNL blast test site. This site also consists of a 52-meter tower which is configured the same as the 52-meter tower at Site 200. There is also a building at this site that houses the datalogger, communication peripherals and the barometric pressure sensor. At both Site 200 and Site 300, data are collected by Ethernet with telephone modem collection as a backup. The data collection interval for both sites is fifteen (15) minutes via workstations running Loggernet software located at the main lab facility. The audits of the Lawrence Livermore National Laboratory’s two automated meteorological stations located near Livermore, California were performed on October 24 & 25, 2023. These audits were performed under the guidelines of the Quality Assurance Handbook for Air Pollution Measurement Systems, Volume IV, Version 2 and the On-Site Meteorological Program Guidance for Regulatory Modeling Applications, U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Creating a Salt Batch: Challenges and Lessons Learned

CONCLUSION • The overall Salt Batch system has been honed through each iteration of the process • Increased communication across facilities and work groups has enabled the salt team to react swiftly to emergent items and identify improvement opportunities • Even the best plans require backup options – Emergent items can appear at any time during the process – Flexibility to adapt to the unexpected is a must-have team mindset • To date, every salt batch compiled has been qualified and approved as feed for SWPF – No feed break has occurred between the Tank Farm and SWPF

Goldblatt, Joshua B. [Savannah River National Labo↗

Reliable Broadcast under Cascading Failures in Interdependent Networks

Reliable broadcast is an essential tool to disseminate information among a set of nodes in the presence of failures. We present a novel study of reliable broadcast in interdependent networks, in which the failures in one network may cascade to another network. In particular, we focus on the interdependency between the communication network and power grid network, where the power grid depends on the signals from the communication network for control and the communication network depends on the grid for power. In this paper, we build a resilient solution to handle crash failures in the communication network that may cause cascading failures and may even partition the network. In order to guarantee that all the correct nodes deliver the messages, we use soft links, which are inactive backup links to non-neighboring nodes that are only active when failures occur. At the core of our work is a fully distributed algorithm for the nodes to predict and collect the information of cascading failures so that soft links can be maintained to correct nodes prior to the failures. In the presence of failures, soft links are activated to guarantee message delivery and new soft links are built accordingly for long term robustness. Our evaluation results show that the algorithm achieves low packet drop rate and handles cascading failures with little overhead.

cascading failures↗

Identifying emerging smart grid impacts to upstream and midstream natural gas operations.

The Smart Grid has come to describe a next-generation electrical power system that is typified by the increased use of communications and information technology in the generation, delivery and consumption of electrical energy. Much of the present Smart Grid analysis focuses on utility and consumer interaction. i.e. smart appliances, home automation systems, rate structures, consumer demand response, etc. An identified need is to assess the upstream and midstream operations of natural gas as a result of the smart grid. The nature of Smart Grid, including the demand response and role of information, may require changes in upstream and midstream natural gas operations to ensure availability and efficiency. Utility reliance on natural gas will continue and likely increase, given the backup requirements for intermittent renewable energy sources. Efficient generation and delivery of electricity on Smart Grid could affect how natural gas is utilized. Things that we already know about Smart Grid are: (1) The role of information and data integrity is increasingly important. (2) Smart Grid includes a fully distributed system with two-way communication. (3) Smart Grid, a complex network, may change the way energy is supplied, stored, and in demand. (4) Smart Grid has evolved through consumer driven decisions. (5) Smart Grid and the US critical infrastructure will include many intermittent renewables.

03 NATURAL GAS↗

Los Angeles Air Force Base Vehicle-to-Grid Demonstration (Final Project Report)

Electrification of non-tactical vehicle fleets represents a key efficiency and energy security objective for the United States Department of Defense. To achieve electrification, the department targeted vehicle-to-grid services as a way to decrease the overall cost of operating the vehicle fleet and achieve rough parity with traditional internal combustion engine vehicle fleets. This report describes efforts to aggregate a fleet of bi-directional electric vehicles and charging stations to provide regulation up and regulation down in the California Independent System Operator ancillary services market. A 29-vehicle electric vehicle demonstration fleet, consisting of mixed purpose and duty vehicles such as sedans, pickups, vans, and medium-duty trucks, was deployed at the Los Angeles Air Force base. The fleet provided frequency regulation to the California Independent System Operator’s wholesale electricity market to determine the capability of recouping some of the additional costs of procuring electric vehicles and their supporting infrastructure. Lawrence Berkeley National Laboratory, with its partner Kisensum, LLC, developed the fleet scheduling, optimization, and control software to allow the vehicle fleet at the air force base to participate in the ancillary services markets. This report focuses on the control software and market interactions, the significant challenges faced and solutions devised to address them, and examines the potential of using the electric vehicle fleet as an energy storage resource for the base buildings, an application known as vehicle-tobuilding, in providing demand response and emergency backup power. The report discusses key findings related to providing frequency regulation to the California Independent System Operator market, electric vehicle fleet performance, compatibility of varying resource parameters of vehicle fleet aggregation, the need for automated methods for communicating hour-ahead energy bidding, challenges related to battery capacity and charge/discharge rates, and monthly settlement revenue.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disaster-survivable cloud-network mapping

Cloud-computing services are provided to consumers through a network of servers and network equipment. Cloud-network (CN) providers virtualize resources [e.g., virtual machine (VM) and virtual network (VN)] for efficient and secure resource allocation. Disasters are one of the worst threats for CNs as they can causemassive disruptions and CN disconnection. A disaster may also induce post-disaster correlated, cascading failures which can disconnect more CNs. Survivable virtual-network embedding (SVNE) approaches have been studied to protect VNs against single physical-link/- node and dual physical-link failures in communication infrastructure, but massive disruptions due to a disaster and their consequences can make SVNE approaches insufficient to guarantee cloud-computing survivability. In this work, we study the problem of survivable CN mapping from disaster. We consider risk assessment, VM backup location, and post-disaster survivability to reduce the risk of failure and probability of CN disconnection and the penalty paid by operators due to loss of capacity.We formulate the proposed approach as an integer linear program and study two scenarios: a natural disaster, e.g., earthquake and a human-made disaster, e.g., weapons-of-mass-destruction attack. Finally, our illustrative examples show that our approach reduces the risk of CN disconnection and penalty up to 90% compared with a baseline CN mapping approach and increases the CN survivability up to 100% in both scenarios.

97 MATHEMATICS AND COMPUTING↗

A Robust Communication-Free Protection Scheme for Islanded Microgrids with Relay Logic and Hardware-in-the-Loop Validation

This paper presents the Imbalance Square Factor (ISF) detection algorithm, an effective, computationally lightweight method for detecting faults in inverter-based microgrids. ISF provides a high magnitude at the time of the fault, which allows for fast detection and coordination between primary and backup relays. The imbalance squared factor, calculated using local voltage and currents, is used for fault detection and coordination among three relays. ISF is validated in hardware-in-the-loop (HIL) implementation inside commercial-grade relay logic (SEL-751). The HIL validation shows that ISF can coordinate primary, secondary, and tertiary relays in the 13-bus system in islanded operation.

Ferrari Maglia, Max [ORNL]↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The energy footprint of automotive electronic sensors

We discuss how Information and communication technologies (ICT) have emerged as one of the leading technologies to reduce global emissions, particularly in the mobility sector. Automotive electronics, such as sensors/actuators and microcontrollers (commonly known as electronic control units (ECU) which control one or more of the electrical systems or subsystems in a vehicle), play a key role in ICT. Sensors/actuators are key in electronic ICT devices, starting with the data collection and data communication with the internet. The latest two big trends of electrification and automation in vehicles, are projected to increase the use of worldwide automotive sensors from 7.5 billion units in 2017 to 11.0 billion units by the year 2024. A representative state-of-the art automotive sensor system, (i.e., an ultrasonic backup system), including the ECUs controlling the vehicle electrical systems/subsystems, has been considered to estimate the energy footprint in terms of manufacturing and operational energy of global automotive sensors use. A widely used life cycle energy assessment method (i.e., cumulative energy demand) was used as both direct and indirect (including the extraction, manufacturing, and disposal of the raw and auxiliary materials) energy use can be considered for the energy footprint estimation. The embodied manufacturing energy impacts of the system was estimated to be 559 MJ/system, compared to the 417 MJ/system for lifetime system power and additional gasoline use. The share of purchased energy to the embodied energy where the upstream energy isn't included in the former case, is less than 10% and ~ 85% for the component manufacturing and vehicle operation energy uses, respectively. As the purpose of this ultrasonic backup system is to prevent rear crashes, an estimated 1.0 MJ/system is avoided from reduced lifetime vehicular repairs (from an estimated 11% chance of requiring a rear bumper replacement). While all of this is small compared to the overall automotive manufacturing and use energy, the 11 billion automotive sensors expected to be produced in 2024 could require 1540 PJ for manufacturing and those sensors would require an additional 780–1150 PJ for lifetime energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) Field Campaign Report

The scientific focus here is interagency collaboration to support a National Aeronautics and Space Administration (NASA)-sponsored 2023 field campaign: Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS). IMPACTS objectives are to provide observations critical to understanding the mechanisms of snowband formation, organization, and evolution; study how the microphysical characteristics and likely growth mechanisms of snow particles vary across snowbands; and improve snowfall remote-sensing interpretation and modeling to significantly advance predictive capabilities. The relevance to The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility's mission was to support the Interagency Council for Advancing Meteorological Services (ICAMS)’ objectives to enhance communication and coordination, and promote sharing, within and across agencies. NASA therefore requested to borrow ARM’s two-dimensional stereo probe (2DS) for possible use during the 2023 IMPACTS project. Additionally, this use of the 2DS could improve understanding of ARM 2DS measurements collected on previous field campaigns. The plan was to have the 2DS available for possible backup deployment on the NASA Lockheed Orion P-3 aircraft during the 2023 IMPACTS field project. NASA has a 2DS probe and the ARM 2DS is a hot swappable probe in case the project's 2DS fails. The 2DS is a critical probe and we had issues during a 2022 field project that prevented us from obtaining 2DS data on several flights. Hence, we wanted a hot swappable 2DS on stand-by. We have a data acquisition system, along with a backup data acquisition system for the 2DS, so we only needed the 2DS probe. David Delene was responsible for the use of the 2DS on the NASA P-3 aircraft. He has experience deploying the 2DS on several aircraft, including previously on the NASA P-3 in 2022. The team ensured that the aircraft wiring and deployment of the 2DS were completed correctly for the ARM 2DS.

54 ENVIRONMENTAL SCIENCES↗

Recovery Act - PEM Fuel Cell Systems Providing Emergency Reserve and Backup Power (Final Technical Report)

The STI product is the Final Technical Report from ReliOn, Inc. for contract award DE-EE0000487: Recovery Act PEM Fuel Cell Systems Providing Emergency Reserve and Backup Power. The program covered the turnkey deployment of 431 ReliOn fuel cell systems at 189 individual sites for AT&T and PG&E with ReliOn functioning as the primary equipment supplier and the project manager. The Final Technical Report provides an executive level summary, a comparison of the actual accomplishments vs. the goals and objectives of the project, as well as a summary of the project activity from the contract award date of August 1, 2009 through the contract expiration date of December 31, 2011. Two photos are included in the body of the report which show hydrogen storage and bulk hydrogen refueling technologies developed as a result of this program.

08 HYDROGEN↗

Early Market TRL/MRL Analysis

he focus of this report is TRL/MRL analysis of hydrogen storage; it documents the methodology and results of an effort to identify hydrogen storage technologies’ technical and manufacturing readiness for early market motive and non-motive applications and to provide a path forward toward commercialization. Motive applications include materials handling equipment (MHE) and ground support equipment (GSE), such as forklifts, tow tractors, and specialty vehicles such as golf carts, lawn mowers and wheel chairs. Non-motive applications are portable, stationary or auxiliary power units (APUs) and include portable laptops, backup power, remote sensor power, and auxiliary power for recreational vehicles, hotels, hospitals, etc. Hydrogen storage technologies assessed include metal hydrides, chemical hydrides, sorbents, gaseous storage, and liquid storage. The assessments are based on a combination of Technology Readiness Level (TRL) and Manufacturing Readiness Level (MRL) designations that enable evaluation of hydrogen storage technologies at varying levels of development. The manufacturing status could be established from eight risk elements: Technical Maturity, Design, Materials, Cost & Funding, Process Capability, Personnel, Facilities and Manufacturing Planning. This approach provides a logical methodology and roadmap to enable the identification of hydrogen storage technologies, their advantages/disadvantages, gaps and R&D needs on an unbiased and transparent scale that is easily communicated to interagency partners. This technology readiness assessment (TRA) report documents the process used to conduct the TRA/MRA (technology and manufacturing readiness assessment), reports the TRL and MRL for each assessed technology and provides recommendations based on the findings. To investigate the state of the art and needs to mature the technologies, PNNL prepared a questionnaire to assign TRL and MRL for each hydrogen storage technology. The questionnaire was sent to identified hydrogen storage technology developers and manufacturers who were asked to perform a self-assessment. We included both domestic and international organizations including U.S. national laboratories, U.S. companies, European companies and Japanese companies. PNNL collected the data and performed an analysis to deduce the level of maturity and to provide program recommendations.

early market↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗

System Engineering Analysis For Improved Scout Business Information Systems

The project uses system engineering principles to address the need of Boy Scout leaders for an integrated system to facilitate advancement and awards records, leader training and planning for meetings and activities. Existing products to address needs of Scout leaders and relevant stakeholders function to support record keeping and some communication functions but opportunity exists for a better system to fully integrate these functions with training delivery and recording, activity planning along with feedback and information gathering from stakeholders. Key stakeholders for the sytem include Scouts and their families, leaders, training providers, sellers of supplies and awards, content generators and facilities that serve Scout activities. Key performance parameters for the system are protection of personal information, availability of current information, information accuracy and information content that has depth. Implementation concepts considered for the system include (1) owned and operated by Boy Scouts of America, (2) Contracted out to a vendor (3) distributed system that functions with BSA managed interfaces. The selected concept is to contract out to a vendor to maximize the likelihood of successful integration and take advantage of the best technology. Development of requirements considers three key use cases (1) System facilitates planning a hike with training needed satisfied in advance and advancement recording real time (2) Scheduling and documenting in-person training, (3) Family interested in Scouting receives information and can request follow-up. Non-functional requirements are analyzed with the Quality Function Deployment tool. Requirement addressing frequency of backup, compatibility with legacy and new technology, language support, software update are developed to address system reliability and intuitive interface. System functions analyzed include update of activity database, maintenance of advancement status, archive of documents, and monitoring of content that is accessible. The study examines risks associated with information security, technological change and continued popularity of Scouting. Mitigation is based on system functions that are defined. The approach to developing an improved system for facilitating Boy Scout leader functions was iterative with insights into capabilities coming in the course of working through the used cases and sequence diagrams.

97 MATHEMATICS AND COMPUTING↗

Self-powered Wireless Dual-mode Langasite Sensor for Pressure/Temperature Monitoring of Nuclear Reactors

Safety issues in nuclear power plants are of extreme importance. Numerous sensors are used within nuclear power plants for sensing and monitoring of its critical operation parameters. As currently implemented, during massive losses of power across the plant in accidents, the backup batteries for the monitoring sensors will ultimately be drained and can cease to operate. The overall objective of this NEUP project is to develop a novel self-powered wireless hybrid sensor which can accurately monitor both pressure and temperature using a single device, even in the extreme harsh environments of severe nuclear accidents, without the requirement of external electricity. At Virginia Tech side, a heat pipe assisted thermoelectric generator (TEG) energy harvester and associated power management and data transmission circuits were developed. The energy harvester can produce electrical power continuously, even in loss of plant and external power situations, providing power for important data transmission for accident diagnosis. The self-powered sensing system could be integrated directly onto key nuclear components including pipes, pump housings, heat exchangers, reactor vessels, and shielding structures inside and outside of the reactor core. Two TEG based energy harvesters which can work in relatively low (50-250 ºC) and high temperature ranges (250-350 ºC) were established and tested. In the prototypes, heat pipes were introduced to reduce the heat resistances of the device at the hot and cold ends. The power output of the heat pipe assisted TEG module is 2.22 W, which is 6 times more than one using an aluminum rod. In-lab tests showed that these devices canmeet the requirement to power the sensors and circuit during normal and off-normal conditions.Amodel was then built to analyze the thermal network in the energy harvester, and was used to optimize its performance and reduce its geometry size. The design and testing of the vibrational energy harvester were completed. The harvester, has shown to effectively increase the vibrational potential of the main coolant pump, though it has been shown that thermal energy has a much higher potential for the powering of sensors. In this project, a self-start charger circuit for the energy harvester was designed to regulate and manage the power. An energy storage element was incorporated into the energy harvesting module for sensors and wireless transceivers in an off-normal situation. The signal conditioning and wireless communication electronic circuits were developed and tested in the lab. An important consideration for an energy harvester within a nuclear power plant is the level of radiation it will encounter during operation. The two main sources of radiation in a nuclear power plant are gamma and neutron radiation. Aradiation experiment was conducted in the Westinghouse Electric Company during which the prototypes were placed in a 106 rad radiation environment to test their ability to operate in the extreme environment. The results showed that this level of radiation had little effect on the performance of the TEGmaterial and heat pipe heat exchanging system. Its influence on the circuit was still under research, however the need for more development on radiation hardened electronics is needed. Pressure measurement based on piezoelectric crystal resonators has advantages over the commercially available methods like capacitive, electromagnetic, optical, potentiometric, and piezo resistive strain gauges. Since the output of piezoelectric based sensors are digital in format, it has a very high resolution, high accuracy, and long-term stability. Quartz is one of the commonly used piezoelectric material in digital pressure sensors design. This material is elastic in nature, providing high stability, high repeatability, high elasticity, repeatable mechanical behavior for many cycles of operation, and is free of hysteresis. The quartz resonator has a high Q, which means that very high vibration can be driven with the very low electric power. Langasite (LGS) is a new promising piezoelectric material that combines the advantageous properties of quartz with a better performance at high temperatures. LGS will not undergo any phase transitions up to its melting temperature of 1473 C, and hence, the application of Langasite in measuring pressure at high temperatures is promising. In this project, the design and fabrication of the piezo oscillator crystal for temperature and pressure measurement has been completed. The entire sensor has been fabricated and tested to see its sensitivity to temperature and pressure changes. The design and optimization of the radiation shielding systems that can effective protect the duel-mode Langasite sensor inside reactor core were demonstrated. To maximize the radiation shielding effectiveness, different types of materials are investigated based upon recent developments of radiation shielding systems including aluminum + Boron carbide and bismuth borosilicate glass B2O3 in addition to tungsten/B4C. New materials based upon metatheses is included as potential shielding to mitigate neutron fluencies. The radiation shielding effectiveness of selected composites are evaluated within a broader neutron spectrum from thermal, epithermal, fast (1 MeV) and 15 MeV neutrons. Performance analysis was also conducted to evaluate the effects of selected composite systems.Aconceptual design was also proposed for the packaging and integration of the radiation shielding system with the sensor, and its applicability within the reactor core was discussed. At end of the project, all components necessary for a complete sensing and monitoring system, including a langasite sensor, electrodes, the TEG harvester, an energy storage device, and power management and transmission electronics were integrated to demonstrate feasibility in powering the sensor. Finally, integration of each component into a full package, and a full demonstration were done.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗