Search NASA⌕ Search

SEARCH · Search NASA

Results for “BBS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SU-E-J-46: Evaluation of the Accuracy of a Six Degree of Freedom Robotic Couch Using ConeBeam CT Images of the Isocal Phantom

Purpose The accuracy of Varian PerfectPitch six degree of freedom (DOF) robotic couch was examined using Varian Isocal phantom and cone-beam CT (CBCT) system. Methods CBCT images of the Isocal phantom were taken at different pitch and roll angles. The pitch and roll angles were varied from 357 to 3 degrees in one degree increments by input from service console, generating a total of 49 combinations with couch angle (yaw) zero. The center positions of the 16 tungsten carbide BBs contained in the Isocal were determined with in-house image processing software. Expected BBs positions at different rotation angles were determined mathematically by applying a combined translation/rotation operator to BB positions at zero pitch and roll values. A least square method was used to minimize the difference between the expected BB positions and their measured positions. In this way rotation angles were obtained and compared with input values from the console. Results A total of 49 CBCT images with voxel sizes 0.51 mm × 0.51 mm × 1 mm were used in analysis. Among the 49 calculations, the maximum rotation angle differences were 0.1 degree, 0.15 degree, and 0.09 degree, for pitch, roll, and couch rotation, respectively. The mean ± standard-deviation angle differences were 0.028±0.001 degree, −0.043±0.003 degree, and −0.009±0.001 degree, for pitch, roll, and couch rotation, respectively. The maximum isocenter shifts were 0.3 mm, 0.5 mm, 0.4 mm in x, y, z direction respectively following IEC6127 convention. The mean isocenter shifts were 0.07±0.02 mm, −0.05±0.06 mm, and −0.12±0.02 mm in x, y and z directions. Conclusion The accuracy of the Varian PerfectPitch six DOF couch was studied with CBCTs of the Isocal phantom. The rotational errors were less than 0.15 degree and isocenter shifts were less than 0.5 mm in any direction. This accuracy is sufficient for stereotactic radiotherapy clinical applications.

60 APPLIED LIFE SCIENCES↗

SU-E-T-431: Feasiblity of Using CT Scout Images for 2D LDR Brachytherpay Planning

Purpose: i) To show the feasibility of using CT scout images for 2D low-dose rate brachytherapy planning with BrachyVision (version 10.4); ii) to show their advantages and disadvantages over DRRs. Methods: A phantom was constructed to house a Fletcher-Suite applicator. The phantom is made of Styrofoam with metal BBs positioned at well-defined separations. These markers are used to assess the image distortion in the scout images. Unlike DRRs, scout images are distorted only in the direction normal to the couch direction; therefore, they needed to be scaled unidirectionally prior to importing into BrachyVision. In addition to confirming the scaling is performed correctly by measuring distances between well-positioned BB, we also compare a LDR plan using scout images to a 3D CT-based plan. Results: There is no distortion of the image along the couch direction due to the collimation of the CT scanner. The distortion in the transverse plane can be corrected by multiplying by the ratio of distances between source-to-isocenter and source-to-detector. The results show the distance separations between BBs as measured in scout images and by a caliber are within a few millimeters. Dosimetrically, the difference between the dose rates to points A and B based on scout images and on 3D CT are less than a few percents. The accuracy can be improved by correcting for the distortion on the transverse plane. Conclusion: It is possible to use CT scout images for 2D planning in BrachyVision. This is an advantage because scout images have no metal artifacts often present in CT images or DRRs. Another advantage is the lack of distortion in the couch direction. One major disadvantage is that the image distortion due to beam divergence can be large. This is due to the inherent short distance between source-to-isocenter and source-to-detector on a CT scanner.

60 APPLIED LIFE SCIENCES↗

Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linear rheology and structure of molecular bottlebrushes with short side chains

We investigate the microstructure and linear viscoelasticity of model molecular bottlebrushes (BBs) using rheological and small-angle X-ray and neutron scattering measurements. Our polymers have short atactic polypropylene (aPP) side chains of molecular weight ranging from 119 g/mol to 259 g/mol and narrow molecular weight distribution (M{sub w}/M{sub n} 1.02–1.05). The side chain molecular weights are a small fraction of the entanglement molecular weight of the corresponding linear polymer (M{sub e,aPP}= 7.05 kg/mol), and as such, they are unentangled. The morphology of the aPP BBs is characterized as semiflexible thick chains with small side chain interdigitation. Their dynamic master curves, obtained by time-temperature superposition, reveal two sequential relaxation processes corresponding to the segmental relaxation and the relaxation of the BB backbone. Due to the short length of the side chains, their fast relaxation could not be distinguished from the glassy relaxation. The fractional free volume is an increasing function of the side chain length (N{sub SC}). Therefore, the glassy behavior of these polymers as well as their molecular friction and dynamic properties are influenced by their N{sub SC} values. The apparent flow activation energies are a decreasing function of N{sub SC}, and their values explain the differences in zero-shear viscosity measured at different temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ring-based electron cooler for EIC

An Electron Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is being proposed as a new discovery machine for the nuclear physics and quantum chromodynamics. The hadron beam cooling plays an important role in the EIC machine to achieve its physics goals. The most challenging is cooling of protons at the highest energy in the EIC. In this paper, we present a possible design of a ring-based electron cooler for the high energy hadron beam cooling. In proposed approach, the electrons will cool the hadrons while being cooled themselves by radiation damping in the storage ring. For design of the cooler using storage ring approach several aspects becomes very important, including electron ring optics design, chromaticity correction, calculate the dynamic aperture, radiation damping, quantum excitation, and intrabeam scattering (IBS). In addition, such effects as beam-beam scattering (BBS) due to interaction of electrons with hadrons become of special concern. In this paper, we discuss and take into design all the effects above, as well as introduce generalized treatment of the BBS and 3-D quantum lifetime. A special feature of our design is an effective use of dispersion in the cooling section, both for the ions and electrons, to redistribute the cooling rate between the longitudinal and horizontal planes. Finally, the cooling performance is simulated for proton beam at the top energy of the EIC. Our conclusion is that such ring-based cooler could be a feasible approach to provide required parameters of hadron beam at the top energy of 275 GeV for the EIC.

43 PARTICLE ACCELERATORS↗

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

Bioconversion of Pelletized Big Bluestem, Switchgrass, and Low-Diversity Grass Mixtures Into Sugars and Bioethanol

Three crops of warm-season grasses are being developed for biomass production on northern rain-fed marginal farmland: big bluestem (BBS), switchgrass (SG), and a low diversity mixture of grasses (LDM). In this study, biomass harvested from established fields were compared for pelletization and subsequent conversion to sugars and ethanol. Each biomass was successfully pelletized to similar bulk densities without adding a binder at a commercial feed operation. Pelletizing increased the bulk density by 407% on average and was equally effective on all three biomass samples (528–554 kg/m 3 ). Chemical analysis of the samples indicated that glucan and xylan contents were slightly reduced during pelletizing (by 23 and 16 g/kg, respectively), as well as theoretical ethanol yields, which are based upon total carbohydrate contents. Pellets and milled straws were pre-treated with either liquid hot-water or low-moisture ammonium hydroxide (LMA) and subsequently hydrolyzed with cellulases. Glucose and total sugar yields were similar for non-pellets and pellets using either pre-treatment; carbohydrates present in pellets were more efficiently recovered compared to non-pellets. LMA pretreated samples were separately hydrolyzed and fermented to ethanol using Scheffersomyces stipitis yeast. Hydrolysis recovered 69.7–76.8% of the glucose and 66.5–73.3% of the xylose across all samples. Glucose yields were 251–279 g/kg, db and were significantly lower for SG as compared to the other biomass samples. Recovered sugars were fermented to ethanol at 77.7–86.7% of theoretical yield. As a result, final ethanol yields (245.9–275.5 L/Mg, db) were similar for all of the grasses and estimated to equate to production levels for BBS, LDM, and SG of 1,952, 2,586, and 2,636 l of ethanol per ha, respectively.

59 BASIC BIOLOGICAL SCIENCES↗

Orchestrating Fault Prediction with Live Migration and Checkpointing

Checkpoint/Restart (C/R) is widely used to provide fault tolerance on High-Performance Computing (HPC) systems. However, Parallel File System (PFS) overhead and failure uncertainty cause significant application overhead. This paper develops an adaptive multi-level C/R model that incorporates a failure prediction and analysis model, which orchestrates failure prediction, checkpointing, checkpoint frequency, and proactive live migration along with the additional benefit of Burst Buffers (BB). It effectively reduces the overheads due to failures, checkpointing, and recovery. Simulation results for the Summit supercomputer yield a reduction of ~20%-86% in application overhead due to BBs, orchestrated failure prediction, and migration. We also observe a ~29% decrease in checkpoint writes to BBs, which can increase the longevity of the BB storage devices.

Behera, Subhendu↗

3D Printing of Aqueous Two-Phase Systems with Linear and Bottlebrush Polyelectrolytes

In this study, we formed core–shell-like polyelectrolyte complexes (PECs) from an anionic bottlebrush polymer with poly (acrylic acid) side chains with a cationic linear poly (allylamine hydrochloride). By varying the pH, the number of side chains of the polyanionic BB polymers (Nbb), the charge density of the polyelectrolytes, and the salt concentration, the phase separation behavior and salt resistance of the complexes could be tuned by the conformation of the BBs. By combining the linear/bottlebrush polyelectrolyte complexation with all-liquid 3D printing, flow-through tubular constructs were produced that showed selective transport across the PEC membrane comprising the walls of the tubules. These tubular constructs afford a new platform for flow-through delivery systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic analysis of the benefits to petroleum refiners for low carbon boosted spark ignition biofuels

A refinery modeling framework is developed to estimate the benefits of blending high-quality biofuels directly with refinery gasoline components for attaining a premium grade fuel (also termed as Co-Optima Boosted SI gasoline here). Our results change the paradigm of bio-blendstocks (BBs) being competitors to fossil components, by identifying opportunities for refineries to add value to their product slate, from some favorable BB properties. This potential value can be characterized by calculating the breakeven value (BEV), as defined down below. The proposed modeling framework incorporates extensive data from (1) projected product over the next few decades, (2) crude oil and refinery products pricing, and (3) fuel specifications. The complete refinery models serve as a basis for assessing the value of biofuels, assuming profitability remains the same for representative petroleum refinery configurations. Our assessment showed wide range of variation of biofuels BEV from $\$$20-$\$$120/bbl, within the considered blending level and crude prices. Further, the BEV was correlated with the fuel octane ratings such as octane numbers (research, RON and motor octane numbers, MON) and both antiknock index (AKI, average of RON and MON) and sensitivity (S, difference between RON and MON), with a slightly higher correlation with the sensitivity. However, the expected decrease in gasoline demand for the upcoming years could negatively impact biofuels demand and value, in a business-as-usual scenario. Our analysis also showed a more valuable bio-blendstocks incorporation in smaller refineries since they can enhance the capabilities for producing specialty, high-value fuels/products, and introduce high octane-barrels into otherwise constrained blending operations. Additional implications towards refiners include opportunities to rebalance operations, access to high-value fuel markets, and synchronization with broader transportation industry trends. Furthermore, results indicate the value of Co-Optima boosted spark ignition (BSI) efficiency gains can extend to refiners to incentivize decarbonization and diversified feedstock production.

09 BIOMASS FUELS↗

Study of the Pygmy Dipole Resonance in {sup 124}Sn by means of the ({alpha},{alpha}'{gamma}) reaction

In recent years {alpha}-{gamma} coincidence experiments at 136 MeV incident energy on {sup 48}Ca, {sup 140}Ce, {sup 138}Ba and {sup 124}Sn were performed at the KVI in Groningen to study the isospin character of electric dipole excitations below the particle threshold, frequently called Pygmy Dipole Resonance (PDR). An array of HPGe {gamma}-detectors has been used in coincidence with the Big-Bite Spectrometer (BBS) and a resolution of about 10 keV in the {gamma}-ray energy has been achieved. The results show that the excitation patterns of the PDR in the ({alpha},{alpha}') reaction seem to differ significantly from results obtained in Nuclear Resonance Fluorescence (NRF)({gamma},{gamma}') measurements. The PDR, which until now has been assigned to one excitation mode, splits up into two parts: One that is excited in ({alpha},{alpha}'{gamma}) and ({gamma},{gamma}') reactions (denoting a dominant isoscalar character), and one that is only excited in ({gamma},{gamma}')(denoting a dominant isovector character). This indicates that two different excitation mechanisms produce these low-lying E1 excitations [1], The preliminary results of the latest measurements on the N = 82 nucleus {sup 138}Ba and the Z = 50 nucleus {sup 124}Sn show that this break up into two parts is a common feature of the PDR in semi-magic nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Splitting of the Pygmy Dipole Resonance

In recent years investigations have been made to study the electric Pygmy Dipole Resonance (PDR) systematically, mainly in semi-magic nuclei. For this purpose the well understood high resolution ({gamma},{gamma}') photon scattering method is used. In complementary ({alpha},{alpha}'{gamma}) coincidence experiments at E{sub {alpha}} = 136 MeV a similar {gamma}-energy resolution and a high selectivity to E1 transitions can be obtained at the Big-Bite Spectrometer (BBS) at KVI, Groningen. In comparison to the ({gamma},{gamma}') method a structural splitting of the PDR is observed in the N = 82 nuclei {sup 138}Ba and {sup 140}Ce and in the Z = 50 nucleus {sup 124}Sn. The low energy part is excited in ({gamma},{gamma}') as well as in ({alpha},{alpha}'{gamma}) while the high energy part is observed in ({gamma},{gamma}') only. The experimental results together with theoretical QPM and RQTBA calculations on {sup 124}Sn which are able to reproduce the splitting of the PDR qualitatively are presented. The low-lying group of J{sup {pi}} = 1{sup -} states seem to represent the more isoscalar neutron-skin oscillation of the PDR while the energetically higher-lying states seemingly belong to the transitional region between the PDR and the isovector Giant Dipole Resonance (IVGDR).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies on the double-{beta} decay nucleus {sup 64}Zn using the (d,{sup 2}He) reaction

The (d,{sup 2}He) charge-exchange reaction on the double-{beta} decay ({beta}{beta}) nucleus {sup 64}Zn has been studied at an incident energy of 183 MeV. The two protons in the {sup 1}S{sub 0} state (indicated as {sup 2}He) were both momentum analyzed and detected simultaneously by the BBS magnetic spectrometer and its position-sensitive detector. {sup 2}He spectra with a resolution of about 115 keV (FWHM) have been obtained allowing identification of many levels in the residual nucleus {sup 64}Cu with high precision. {sup 64}Zn is one of the rare cases undergoing a {beta}{beta} decay in {beta}{sup +} direction. In the experiment presented here, Gamow-Teller (GT{sup +}) transition strengths have been extracted. Together with the GT{sup -} transition strengths from {sup 64}Ni({sup 3}He,t) data to the same intermediate nucleus {sup 64}Cu, the nuclear matrix elements of the {beta}{beta} decay of {sup 64}Zn have been evaluated. Finally, the GT{sup {+-}} distributions are compared with shell-model calculations and a critical assessment is given of the various residual interactions presently employed for the pf shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The (d,{sup 2}He) reaction on {sup 96}Mo and the double-{beta} decay matrix elements for {sup 96}Zr

The {sup 96}Mo(d,{sup 2}He){sup 96}Nb charge-exchange reaction was investigated at an incident energy of E{sub d}=183.5 MeV. An excitation-energy resolution of 110 keV was achieved. The experiment was performed at KVI, Groningen, using the magnetic spectrometer BBS at three angular positions: 0 deg., 2.5 deg., and 6 deg. We found that below 6 MeV almost the entire Gamow-Teller (GT{sup +}) strength is concentrated in a single state at 0.69 MeV excitation energy. As {sup 96}Mo is the daughter of the {beta}{beta} decay nucleus {sup 96}Zr, the present result provides information about the nuclear matrix elements active in the 2{nu}{beta}{beta} decay of {sup 96}Zr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The (d,{sup 2}He) reaction on {sup 76}Se and the double-{beta}-decay matrix elements for A=76

The (d,{sup 2}He) charge-exchange reaction on {sup 76}Se was studied at an incident energy of 183 MeV. The outgoing two protons in the {sup 1}S{sub 0} state, referred to as {sup 2}He, were both momentum analyzed and detected by the same spectrometer and detector. The experiment was performed at KVI, Groningen, using the magnetic spectrometer BBS at three angular positions: 0 deg., 2.5 deg., and 5 deg. Excitation-energy spectra of the residual nucleus {sup 76}As were obtained with an energy resolution of about 120 keV (FWHM). Gamow-Teller (GT{sup +}) transition strengths were extracted up to 5 MeV and compared with those from an (n,p) experiment at low resolution. Together with the GT{sup -} transition strengths from the {sup 76}Ge(p,n) experiment leading to the same intermediate nucleus, the nuclear matrix element of the two-neutrino double-{beta} decay of {sup 76}Ge was evaluated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-123: Targeting Accuracy of Image-Guided Radiosurgery for Intracranial Lesions

Purpose: To evaluate the setup accuracies of image-guided intracranial radiosurgery across several different linear accelerator platforms. Methods: A CT scan with a slice thickness of 1.0 mm was acquired of a Rando head phantom (The Phantom Laboratory) in a U-frame mask (BrainLAB AG). The phantom had three embedded BBs, simulating a central, left, and anterior lesion. The phantom was setup with each BB placed at the radiation isocenter under image guidance. Four different setup procedures were investigated: (1) NTX-ExacTrac: 6 degree-of-freedom (6D) correction on a Novalis Tx (BrainLAB AG) with ExacTrac localization (BrainLAB AG); (2) NTX-CBCT: 4D correction on the Novalis Tx with cone-beam computed tomography (CBCT); (3) TrueBeam-CBCT: 4D correction on a TrueBeam (Varian) with CBCT; (4) Edge-CBCT: 6D correction on an Edge (Varian) with CBCT. The experiment was repeated 5 times with different initial setup error at each BB location on each platform, and the mean (μ) and one standard deviation (σ) of the residual error was compared.The congruence between radiation and imaging isocenters on each platform was evaluated by acquiring Winston Lutz (WL) images of a WL jig followed by imaging using ExacTrac or CBCT. The difference in coordinates of the jig relative to radiation and imaging isocenters was then recorded. Results: Averaged over all three BB locations, the residual vector setup errors (μ±σ) of the phantom in mm were 0.6±0.2, 1.0±0.5, 0.2±0.1, and 0.3±0.1 on NTX-ExacTrac, NTX-CBCT, TrueBeam-CBCT, and Edge-CBCT, with their ranges in mm being 0.4∼1.1, 0.4∼1.9, 0.1∼0.5, and 0.2∼0.6, respectively. And imaging isocenter was found stable relative to radiation isocenter, with the congruence to radiation isocenter in mm being 0.6±0.1, 0.7±0.1, 0.3±0.1, 0.2±0.1, respectively, on the four systems in the same order. Conclusion: Millimeter accuracy can be achieved with image-guided radiosurgery for intracranial lesions based on this set of experiments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-244: Validation of a 6D-Robotic-Couch and Image Guidance Radiation Therapy (IGRT) System for Localization in World's First Single-Room Proton Therapy System

Purpose: The Mevion S250 proton therapy unit is equipped with a 6D-robotic couch and IGRT system (Verity). The patient alignment process allows corrections in six degrees of freedom: translation (x,y,z), pitch, roll, and yaw (θ,ϑ,ψ). Geometric accuracy of couch corrections and imaging vs. radiation isocenter coincidence were quantified before clinical implementation. Methods: A commercial phantom with sixteen 2mm tungsten BBs was rigidly couch-mounted and imaged with CT. Seventeen rigid translations/rotations of known magnitude were digitally applied to the original CT image using commercial software, validated with Varian OBI system. For each altered image, phantom was mounted on robotic couch in original position, then Verity 2D:2D match (PA-LLAT) was performed using DRRs from altered images. Corrections were recorded and applied, phantom was imaged a second time and residual corrections recorded. Physical measurements verified that applied couch corrections coincided with both physical couch shifts/rotations and known CT image translations/rotations. Additionally, image vs. radiation isocenter coicidence was quantified over couch treatment angles (±90° from setup position) using radiochromic film and an image-guided couch star-shot. Posterior-anterior and left-lateral kV radiographs were taken before each beam was delivered to verify imaging/radiation isocentricity. Results: Verity suggested couch corrections and known CT shifts/rotations agreed within ±1mm (average: Δ lat=0.5mm; Δ vert=0.4mm; Δ long=0.3mm) and ± 0.4° (average: Δ pitch=0.24° Δ roll=0.01°; Δ yaw=0.10°). Physical couch measurements and Verity applied corrections agreed within ± 1mm (average: Δlat=0.5mm; Δvert=0.4mm; Δlong=0.2mm) and ±0.2° (average: Δpitch=0.03°; Δ roll=0.04°; Δ yaw=0.04°). The directionality of all translations and rotations were qualitatively verified. The image vs. radiation isocenter coincidence was <1mm and radiation-isocenter precision was <1mm over the 180° of couch motion, as indicated by film analysis. Conclusion: The Verity IGRT software and 6D-couch combination on the Mevion S250 was verified as accurate within 1mm and 0.5°. This complies with the TG-142 standards for a stereotactic radiotherapy IGRT system. Rob Cessac is employed as Product Manager for Mevion Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-557: Measuring Neutron Activation of Cardiac Devices Irradiated During Proton Therapy Using Indium Foils

Purpose: Measuring Neutron Activation of Cardiac devices Irradiated during Proton Therapy using Indium Foils Methods: The foils had dimensions of 25mm x 25mm x 1mm. After being activated, the foils were placed in a Canberra Industries well chamber utilizing a NaI(Tl) scintillation detector. The resulting gamma spectrum was acquired and analyzed using Genie 2000 spectroscopy software. One activation foil was placed over the upper, left chest of RANDO where a pacemaker would be. The rest of the foils were placed over the midline of the patient at different distances, providing a spatial distribution over the phantom. Using lasers and BBs to align the patient, 200 MU square fields were delivered to various treatment sites: the brain, the pancreas, and the prostate. Each field was shot at least a day apart, giving more than enough time for activity of the foil to decay (t1=2 = 54.12 min). Results: The net counts (minus background) of the three aforementioned peaks were used for our measurements. These counts were adjusted to account for detector efficiency, relative photon yields from decay, and the natural abundance of 115-In. The average neutron flux for the closed multi-leaf collimator irradiation was measured to be 1.62 x 106 - 0.18 x 106 cm2 s-1. An order of magnitude estimate of the flux for neutrons up to 1 keV from Diffenderfer et al. gives 3 x 106 cm2 s-1 which does agree on the order of magnitude. Conclusion: Lower energy neutrons have higher interaction cross-sections and are more likely to damage pacemakers. The thermal/slow neutron component may be enough to estimate the overall risk. The true test of the applicability of activation foils is whether or not measurements are capable of predicting cardiac device malfunction. For that, additional studies are needed to provide clinical evidence one way or the other.

07 ISOTOPE AND RADIATION SOURCES↗