Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM CURRENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Enhancement in ion beam current with layered-glows in a constricted dc plasma ion source

High current mode has been discovered and investigated in a constricted dc plasma ion source. As discharge currents exceed a certain threshold, voltage to sustain the constricted dc plasma suddenly falls down to almost half of the value. In this sense, constricted dc plasmas can be sustained at much higher current than in conventional mode operation at a fixed discharge voltage. Phenomenally, several discrete layered-glows are created between an anode glow and a cathode glow. The layers are thin and divided by dark spaces where charged particles can be accelerated. In this high current mode, ion beam current density is about 100 times higher than in conventional mode at the same voltage. It is noteworthy that lower gas pressure is desirable to sustain the layered-glow mode, which is also profitable for ion source in terms of differential pumping. Ion current density exceeds 300 mA/cm{sup 2} at low discharge power of 175 W where ion density of plasma ball is estimated to be over 3.7x10{sup 12} cm{sup -3}.

43 PARTICLE ACCELERATORS↗

Measurements at peak operational beam current in the SNS beam test facility

Work at the SNS beam test facility has focused on high dimensional and high dynamic range measurements of the medium energy (2.5 Mev) beam distribution. This is motivated by the need to understand and predict beam losses down to one-part-per-million. The initial demonstration of full-and-direct 6D phase space measurement was done at a current of 40 mA transported through the RFQ. Since that demonstration, more detailed studies have been performed at lower transported currents (in the range 30 mA and below). This is due to a hardware change - recent runs utilize the original SNS RFQ, which after a decade of service in the SNS achieves transmission significantly below design (50-60%, vs >80%). A short run in 2023 with a newly-commissioned RFQ enables maximum transmission. Preliminary results from beam distribution measurements during this run are discussed.

Ruisard, Kiersten↗

Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron cyclotron resonance plasma production by using pulse mode microwaves and dependences of ion beam current and plasma parameters on the pulse condition

We measure the ion beam current and the plasma parameters by using the pulse mode microwave operation in the first stage of a tandem type ECRIS. The time averaged extracted ion beam current in the pulse mode operation is larger than that of the cw mode operation with the same averaged microwave power. The electron density n{sub e} in the pulse mode is higher and the electron temperature T{sub e} is lower than those of the cw mode operation. These plasma parameters are considered to cause in the increase of the ion beam current and are suitable to produce molecular or cluster ions.

43 PARTICLE ACCELERATORS↗

RAMPING UP THE SNS BEAM CURRENT WITH THE LBNL BASELINE H- SOURCE

Over the last two years the Spallation Neutron Source (SNS) has ramped up the repetition rate, pulse length, and the beam current to reach 540 kW, which has challenged many subsystems including the H- source designed and built by Lawrence Berkeley National Laboratory (LBNL). This paper discusses the major modifications of the H- source implemented to consistently and routinely output the beam current required by the SNS beam power ramp up plan. At this time, 32 mA LINAC beam current are routinely produced, which meets the requirement for 690 kW planned for end of 2008. In June 2008, a 14-day production run used 37 mA, which is close to the 38 mA required for 1.44 MW. A medium energy beam transport (MEBT) beam current of 46 mA was demonstrated on September 2, 2008.

43 PARTICLE ACCELERATORS↗

Electron beam current in high power cylindrical diode

Intense electron beam generation studies were carried out in high power cylindrical diode to investigate the effect of the accelerating gap and diode voltage on the electron beam current. The diode voltage has been varied from 130 to 356 kV, whereas the current density has been varied from 87 to 391 A/cm{sup 2} with 100 ns pulse duration. The experimentally obtained electron beam current in the cylindrical diode has been compared with the Langmuir-Blodgett law. It was found that the diode current can be explained by a model of anode and cathode plasma expanding toward each other. However, the diode voltage and current do not follow the bipolar space-charge limited flow model. It was also found that initially only a part of the cathode take part in the emission process. The plasma expands at 4.2 cm/mus for 1.7 cm anode-cathode gap and the plasma velocity decreases for smaller gaps. The electrode plasma expansion velocity of the cylindrical diode is much smaller as compared with the planar diode for the same accelerating gap and diode voltage. Therefore, much higher voltage can be obtained for the cylindrical diodes as compared with the planar diodes for the same accelerating gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Air Pressure on Parameters of Beam Current and X-Ray Radiation Generated in a Gas Diode

Parameters of a beam of runaway electrons and X-ray radiation generated in a gas diode at different atmospheric pressures are studied. It is shown that the maximum beam currents and intensities of X-ray radiation are generated at an air pressure of about 10{sup 2} Pa. Distribution of beam electrons with respect to energy is determined by the method of attenuation of beam current using aluminum filters with different thicknesses. The maximum of such a distribution corresponds to an electron energy of about 100 keV. The maximum exposure dose of X-ray radiation behind a copper-foil anode with a thickness of 30 μm is about 107 mR. It is shown that the beam electrons absorbed by elements of an X-ray detector affect the shape and amplitude of the desired signal at beam currents of greater than 35 A/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Current Improvements on the Axcelis Optima HD Imax Implanter

The ability to use large molecular species such as octadecaborane (B{sub 18}H{sub 22}) has been investigated at semiconductor device manufacturers as a way to significantly increase wafer throughput relative to standard high current ion implanters. Over the past two years, improvements in the machine design to support the use of B{sub 18}H{sub 22} have led to beam current increases of 50% from 30 pmA to 45 pmA of boron at an equivalent boron energy of 4 keV. This boron energy is required by p{sup +} doping of dual poly gate (DPG) structures in DRAM. Beam current has also been significantly improved at the low equivalent boron energies anticipated to be required by 32 nm processes for PMOS source/drain extensions (SDE). For example, at 250 eV equivalent beam energy, a 100% increase in cluster boron beam current has been attained.This paper describes the techniques by which these beam current improvements were accomplished, primarily through the refinement of ion beam optics. Other techniques for increasing overall tool productivity are also described, such as beam utilization and overall operational improvements. Wafer throughputs are presented for critical p{sup +} implant processes such as dual poly gate (DPG), source/drain (S/D), source drain extension (SDE) and S/D contact. The higher throughputs resulting from these changes are translated into a cost per wafer (CPW) model and it is demonstrated that an increase in average beam current is the largest contributor to a reduction in CPW.

36 MATERIALS SCIENCE↗

Induced charging of shuttle orbiter by high electron-beam currents

Emission of high-current electron beams that was proposed for some Spacelab payloads required substantial return currents to the orbiter skin in order to neutralize the beam charge. Since the outer skin of the vehicle was covered with approximately 1200 sq m of thermal insulation which has the dielectric quality of air and an electrical conductivity that was estimated by NASA at 10 to the -9 power to 10 to the -10 power mhos/m, considerable transient charging and local potential differences were anticipated across the insulation. The theory for induced charging of spacecraft due to operation of electron guns was only developed for spherical metal vehicles and constant emission currents, which were not directly applicable to the orbiter situation. Field-aligned collection of electron return current from the ambient ionosphere at orbiter altitudes provides up to approximately 150 mA on the conducting surfaces and approximately 2.4 A on the dielectric thermal insulation. Local ionization of the neutral atmosphere by energetic electron bombardment or electrical breakdown may provide somewhat more return current.

Liemohn, H. B.↗

Effects of magnetic field gradient on ion beam current in cylindrical Hall ion source

The effects of the magnetic gradient on the ion beam current in an end Hall-type ion source with a magnetic mirror field are investigated. In a cylindrical Hall ion source in which a cylindrical magnetic ring other than a regular magnetic pole is shortened and centrally inserted, a mirror magnetic field profile can be formed around the annular anode. A positive-negative variable magnetic gradient is shown experimentally to enhance ionization; the ionization efficiency is substantially affected by the different magnetic gradient. The high ionization results in 60% efficiency in the conversion of discharge current to ion beam current. The experimental results and interpretation of the effects are presented in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The DE-AC accelerator system for high beam current density

A radically different ion accelerator system design has been developed to increase the extracted beam current density of ion thrusters. By independently controlling plasma ion extraction and acceleration, the Decoupled Extraction and Amplified Current (DE-AC) accelerator system gives higher beam currents at lower electric field stress levels. Results are presented for DE-AC grid system operation with the Test Bed Ion Engine. Using argon propellant, feasibility of a 60 mA/sq cm beam current density is shown. A discussion of power supply requirements, specific impulse operation and grid system geometrical design is presented also.

Aston, G.↗

Correlation of ion and beam current densities in Kaufman thrusters.

In the absence of direct impingement erosion, electrostatic thruster accelerator grid lifetime is defined by the charge exchange erosion that occurs at peak values of the ion beam current density. In order to maximize the thrust from an engine with a specified grid lifetime, the ion beam current density profile should therefore be as flat as possible. Knauer (1970) has suggested this can be achieved by establishing a radial plasma uniformity within the thruster discharge chamber; his tests with the radial field thruster provide an example of uniform plasma properties within the chamber and a flat ion beam profile occurring together. It is shown that, in particular, the ion density profile within the chamber determines the beam current density profile, and that a uniform ion density profile at the screen grid end of the discharge chamber should lead to a flat beam current density profile.

Wilbur, P. J.↗

Correlation of Measured Surface Contaminants as a Function of Ion Beam Current in GSD Ion Implanters

An investigation into measured differences in surface contaminant levels when evaluating several ion implant tools and/or tool types. For a given species and energy, beam current appears to have a strong effect on final contaminant levels. Ideally one evaluates process integrity at machine set-up conditions that approximate or exceed the worst case conditions required for regular, volume wafer production. Some contaminants may exhibit a 'threshold' effect where they are easily observed with sufficient beam current, but not present at all for lower beam currents. Knowing the characteristics of the measurement process is essential in obtaining reliable results with a clear interpretation and better facilitates cross-site or cross-platform comparisons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A real-time beam current density meter

We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam current enhancement of microwave plasma ion source utilizing double-port rectangular cavity resonator

Microwave plasma ion source with rectangular cavity resonator has been examined to improve ion beam current by changing wave launcher type from single-port to double-port. The cavity resonators with double-port and single-port wave launchers are designed to get resonance effect at TE-103 mode and TE-102 mode, respectively. In order to confirm that the cavities are acting as resonator, the microwave power for breakdown is measured and compared with the E-field strength estimated from the HFSS (High Frequency Structure Simulator) simulation. Langmuir probe measurements show that double-port cavity enhances central density of plasma ion source by modifying non-uniform plasma density profile of the single-port cavity. Correspondingly, beam current from the plasma ion source utilizing the double-port resonator is measured to be higher than that utilizing single-port resonator. Moreover, the enhancement in plasma density and ion beam current utilizing the double-port resonator is more pronounced as higher microwave power applied to the plasma ion source. Therefore, the rectangular cavity resonator utilizing the double-port is expected to enhance the performance of plasma ion source in terms of ion beam extraction.

43 PARTICLE ACCELERATORS↗

The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O{sup 3+}–O{sup 7+} were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

42 ENGINEERING↗

Beam current improvement and source life performance of diboron tetrafluoride (B{sub 2}F{sub 4}) for boron implantation on applied materials VIISta high current implanters

High dose p-type boron doping is a significant productivity challenge for conventional beamline ion implant tools in semiconductor wafer fabrication. Currently, the primary feed gas for boron implantation is boron trifluoride, BF{sub 3}. This paper discusses the testing performed on Applied Materials VIISta high current implanters using diboron tetrafluoride, B{sub 2}F{sub 4}, as an alternative gaseous boron source material that can be a replacement for BF{sub 3}. Both the beam current and source life for B{sub 2}F{sub 4} were evaluated. B{sub 2}F{sub 4} enables a significant beam current improvement over BF{sub 3} while maintaining good source life, beam stability, and a high automatic beam setup success rate.

36 MATERIALS SCIENCE↗