Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Spectrally selective modulation of terahertz radiation beams

We report the results of an experimental study on the focusing of broadband terahertz (THz) radiation using lenses and Fresnel zone plates. The obtained data are compared with the results of numerical simulations. It is shown that the use of lenses for focusing THz radiation can lead to the appearance of a ring structure in the spatial distributions of its intensity. The use of Fresnel zone plates allows the spatial distribution of the THz radiation intensity to be varied at selected frequencies of the spectrum. (terahertz radiation)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Semantic Regression for Disentangling Beam Losses in the Fermilab Main Injector and Recycler

Fermilab’s Main Injector enclosure houses two accelerators: the Main Injector (MI) and the Recycler (RR). In periods of joint operation, when both machines contain high intensity beam, radiative beam losses from MI and RR overlap on the enclosure’s beam loss monitoring (BLM) system, making it difficult to attribute those losses to a single machine. Incorrect diagnoses result in unnecessary downtime that incurs both financial and experimental cost. In this work, we introduce a novel neural approach for automatically disentangling each machine’s contributions to those measured losses. Using a continuous adaptation of the popular UNet architecture in conjunction with a novel data augmentation scheme, our model accurately infers the machine of origin on a per-BLM basis in periods of joint and independent operation. Crucially, by extracting beam loss information at varying receptive fields, the method is capable of learning both local and global machine signatures and producing high quality inferences using only raw BLM loss measurements.

43 PARTICLE ACCELERATORS↗

Radiation hardened beam instrumentations for multi-Mega-Watt beam facilities

The radiation hardened beam instrumentations workshop was held on February 3rd and 4th, 2022 to identify the technological challenges on the beam instrumentation for multi-Mega-Watt (MW) beam facilities. We invited a speaker from a high energy neutrino beam facility (CERN, Fermilab and J-PARC), a collider detector group (CERN and Fermilab), a neutron spallation source facility (ESS, J-PARC and SNS), and a rare-isotope beam facility (FRIB). Although, the operational beam parameter for each institution is unique due to their different physics goals, we realize that there is a common issue on the beam instrumentation. Therefore, it will be tackled by a collaborative R&D effort among facilities. We summarize an output from the workshop in the paper, and propose a possible R&D for the future radiation hardened beam instrumentations with a global effort.

43 PARTICLE ACCELERATORS↗

Ion-beam radiation-induced Eshelby transformations: The mean and variance in hydrostatic and shear residual stresses

Ion beam plays a pivotal role in ion implantations and the fabrication of nanostructures. However, there lacks a quantitative model to describe the residual stresses associated with the ion-beam radiation. Radiation-induced residual stress/transformation strain have been mostly recognized in the hydrostatic sub strain space. Here, in this study, we use molecular dynamics (MD) simulations to show that the response of a material to irradiation is generally anisotropic that depends on the ion-beam direction, and should be described using tensorial quantities. We demonstrate that accelerator-based ion beam irradiation, combined with the intrinsic lattice anisotropy and externally induced anisotropy (such as anisotropic mechanical loadings), causes radiation-actuated shear transformation strains in addition to hydrostatic expansion. We map out these complex correlations for several materials. Radiation-induced defects are shown to be responsible for residual shear stresses in the manner of Eshelby inclusion transformation. We propose such tensorial response model should be considered for accurate nanoscale fabrication using ion-beam irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Device for controlling additive manufacturing machinery

A computing device for controlling the operation of an additive manufacturing machine comprises a memory element and a processing element. The memory element is configured to store a three-dimensional model of a part to be manufactured, wherein the three-dimensional model defines a plurality of cross sections of the part. The processing element is in communication with the memory element. The processing element is configured to receive the three-dimensional model, determine a plurality of paths, each path including a plurality of parallel lines, determine a radiation beam power for each line, such that the radiation beam power varies non-linearly according to a length of the line, and determine a radiation beam scan speed for each line, such that the radiation beam scan speed is a function of a temperature of a material used to manufacture the part, the length of the line, and the radiation beam power for the line.

Barr, Christian↗

Device for controlling additive manufacturing machinery

A computing device for controlling the operation of an additive manufacturing machine comprises a memory element and a processing element. The memory element is configured to store a three-dimensional model of a part to be manufactured, wherein the three-dimensional model defines a plurality of cross sections of the part. The processing element is in communication with the memory element. The processing element is configured to receive the three-dimensional model, determine a plurality of paths, each path including a plurality of parallel lines, determine a radiation beam power for each line, such that the radiation beam power varies non-linearly according to a length of the line, and determine a radiation beam scan speed for each line, such that the radiation beam scan speed is a function of a temperature of a material used to manufacture the part, the length of the line, and the radiation beam power for the line.

Barr, Christian↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Depth-dose relations for heavy ion beams

Radiation transport of heavy ions in matter is of interest to radiological protection in space and high-altitude aircraft. In addition, heavy ion beams are expected to be of advantage in radiotherapy since their characteristic Bragg curve allows a relative reduction of the dose in reaching a tumor site and the near elimination of exposure beyond the tumor region as the beam exits the body. Furthermore, the radioresistance of tumorous cells due to their hypoxic state may be reduced or eliminated by the high specific ionization of heavy ion beams. The depth-dose distribution of heavy ion beams consists of energy deposited by the attenuated primary beam with its characteristic Bragg curve and a relatively unstructured background due to secondary radiations produced in nuclear reactions. As the ion mass increases, the secondary contribution becomes more structured and may add significantly to the Bragg peak of the primary ions. The result for heavy ions (z greater than 20) is a greatly broadened Bragg peak region, especially in comparison to straggling effects, which may prove to be of importance in radiotherapy and biomedical research.

Wilson, J. W.↗

Radiation Hardened Beam Instrumentations for Multi-mega-watt Beam Facilities

A beam instrumentation is an essential element for the successful operate particle accelerators in which various diagnostics and beam control systems are integrated into beam optics. However, the performance of beam instrumentation is often subject to constraints such as prompt radiation dose, integrated radiation dose, operation (ambient) temperature and humidity, available space, and strength of embedded electromagnetic fields at the monitoring point. These constraints will limit the dynamic range of operational beam parameters, like the maximum achievable beam power. A seamless R\&D effort to develop the radiation hardened beam instrumentation should be made for future multi-MW beam facilities. In this paper, we describes about a radiation hardened beam instrumentation based on the operational experience of the NuMI beam line.

43 PARTICLE ACCELERATORS↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Polarizing Grids, their Assemblies and Beams of Radiation

This article gives an analysis of the behavior of polarizing grids and reflecting polarizers by solving Maxwell's equations, for arbitrary angles of incidence and grid rotation, for cases where the excitation is provided by an incident plane wave or a beam of radiation. The scattering and impedance matrix representations are derived and used to solve more complicated configurations of grid assemblies. The results are also compared with data obtained in the calibration of reflecting polarizers at the Owens Valley Radio Observatory (OVRO). From these analysis, we propose a method for choosing the optimum grid parameters (wire radius and spacing). We also provide a study of the effects of two types of errors (in wire separation and radius size) that can be introduced in the fabrication of a grid.

Houde, Martin↗

Device for controlling additive manufacturing machinery

A computing device for controlling the operation of an additive manufacturing machine comprises a memory element and a processing element. The memory element is configured to store a three-dimensional model of a part to be manufactured, wherein the three-dimensional model defines a plurality of cross sections of the part. The processing element is in communication with the memory element. The processing element is configured to receive the three-dimensional model, determine a path across a surface of each cross section, wherein the path includes a plurality of parallel lines, calculate a power for a radiation beam to scan each of the lines, such that the power varies from line to line non-linearly according to a length of the line, and calculate a scan speed for the radiation beam for each of the lines, such that the scan speed varies line to line non-linearly according to the power of the radiation beam.

Barr, Christian↗

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗