Search NASA⌕ Search

SEARCH · Search NASA

Results for “BESSY STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A KB-Focusing Mirror Pair for a VUV-Raman Spectrometer at FLASH - Mirror Metrology and Ray Tracing Results

A plane mirror and two strongly curved plane elliptical mirrors comprising the refocusing system downstream the plane grating monochromator at FLASH in DESY have been characterized with the Nanometer Optical Component Measuring Machine at the BESSY-II Optics Laboratory of the Helmholtz Zentrum Berlin. Based on the measurement results the two elliptical cylinders were optimized by deterministic surface finishing technology (Ion Beam Finishing). The expected focusing performance was verified by ray tracings after each ion beam finish iteration using the measured topography results.

43 PARTICLE ACCELERATORS↗

Full Hemisphere Fermi Surface Mapping Using A Novel Toroidal Electron Spectrometer

An overview is provided of a next-generation toroidal angle-resolving photoemission spectrometer, currently in operation at BESSY II. The instrument features exceptional multi-detection in energy and angle, facilitating rapid full-hemisphere photoemission measurements. The instrument is ideal for band structure and Fermi Surface (FS) mapping using Angle Resolved Photoemission Spectroscopy (ARPES). Recent full-hemisphere FS measurements of a prototypical material, copper, reveal previously unseen fine structure due to lifetime broadening, demonstrating the high angular resolution and dense {kappa}-space sampling capabilities of the instrument.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multitone harmonic-balance simulations of an x-ray transition-edge sensor characterized at BESSY II

We present multitone harmonic-balance (MTHB) simulations of a Ti-Au x-ray transition-edge sensor (TES) microcalorimeter in a 5x5 pixel spectrometer array. The dynamic response of the TES microcalorimeter under simulation has been extremely well characterized at the BESSY II Synchrotron Radiation Facility in Berlin. We compare our simulated results directly with these measurements, and show that the MTHB algorithm is able to simulate to great accuracy the dynamic behavior of the TES, even when saturated by 6 keV photons. In this paper, we provide a detailed account of the MTHB simulations, and discuss the impact of this work on future missions such as the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 {mu}m are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 {mu}m in absorption mode and {approx}14 {mu}m in phase contrast mode (z{sub 2}=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TXM-NEXAFS of TiO{sub 2}-Based Nanostructures

In this work, electronic properties of individual TiO{sub x}-pristine nanoribbons (NR) prepared by hydrothermal treatment of anatase TiO{sub 2} micro-particles were studied using the HZB transmission x-ray microscope (TXM) at the BESSY II undulator beamline U41-FSGM. NEXAFS is ideally suited to study TiO{sub 2}-based materials because both the O K-edge and Ti L-edge features are very sensitive to the local bonding environment, providing diagnostic information about the crystal structures and oxidation states of various forms of titanium oxides and sub-oxides. TXM-NEXAFS combines full-field x-ray microscopy with spectroscopy, allowing the study of the electronic structure of individual nanostructures with spatial resolution better than 25 nm and a spectral resolution of up to E/{Delta}E = 10000. The typical image field in TXM-NEXAFS measurements is about 10 {mu}mx10 {mu}m, which is large compared to the individual nanoparticle. Therefore, one image stack already contains statistically significant data. In addition, the directional electric field vector (E-bar) of the x-rays can be used as a 'search tool' for the direction of chemical bonds of the atom selected by its absorption edge.

36 MATERIALS SCIENCE↗

Femtosecond laser-induced modification of potassium-magnesium silicate glasses: An analysis of structural changes by near edge x-ray absorption spectroscopy

The effects of femtosecond laser pulse irradiation on the glass structure of alkaline silicate glasses were investigated by x-ray absorption near edge structure spectroscopy using the beamline of the Physikalisch-Technische Bundesanstalt at the electron synchrotron BESSY II in Berlin (Germany) by analyzing the magnesium K-edge absorption peak for different laser fluences. The application of fluences above the material modification threshold (2.1 J/cm{sup 2}) leads to a characteristic shift of {approx}1.0 eV in the K-edge revealing a reduced ({approx}3%) mean magnesium bond length to the ligated oxygen ions (Mg-O) along with a reduced average coordination number of the Mg ions.

36 MATERIALS SCIENCE↗

Deflection gating for time-resolved x-ray magnetic circular dichroism-photoemission electron microscopy using synchrotron radiation

In this paper, we present a newly developed gating technique for a time-resolving photoemission microscope. The technique makes use of an electrostatic deflector within the microscope's electron optical system for fast switching between two electron-optical paths, one of which is used for imaging, while the other is blocked by an aperture stop. The system can be operated with a switching time of 20 ns and shows superior dark current rejection. We report on the application of this new gating technique to exploit the time structure in the injection bunch pattern of the synchrotron radiation source BESSY II at Helmholtz-Zentrum Berlin for time-resolved measurements in the picosecond regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast x-ray photoelectron spectroscopy in the microsecond time domain

We introduce a new approach for ultrafast in situ high-resolution X-ray photoelectron spectroscopy (XPS) to study surface processes and reaction kinetics on the microsecond timescale. The main idea is to follow the intensity at a fixed binding energy using a commercial 7 channeltron electron analyzer with a modified signal processing setup. This concept allows for flexible switching between measuring conventional XP spectra and ultrafast XPS. The experimental modifications are described in detail. As an example, we present measurements for the adsorption and desorption of CO on Pt(111), performed at the synchrotron radiation facility BESSY II, with a time resolution of 500 μs. Due to the ultrafast measurements, we are able to follow adsorption and desorption in situ at pressures of 2 × 10{sup −6} mbar and temperatures up to 500 K. The data are consistently analyzed using a simple model in line with data obtained with conventional fast XPS at temperatures below 460 K. Technically, our new approach allows measurement on even shorter timescales, down to 20 μs.

36 MATERIALS SCIENCE↗

Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response

CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV < photon energy < 5 keV) use only a filter and a coaxial detector. A further improvement of DMX consists in flat-response X-ray channels for a precise absolute measurement of the photon flux in the photon energy range from 0.1 keV to 6 keV. Such channels are equipped with a filter, a Multilayer Mirror (MLM), and a coaxial detector. We present as an example the development of channel for the gold M emission lines in the photon energy range from 2 keV to 4 keV which has been successfully used on the OMEGA laser facility. The results of the radiant power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALICE—An advanced reflectometer for static and dynamic experiments in magnetism at synchrotron radiation facilities

We report on significant developments of a high vacuum reflectometer (diffractometer) and spectrometer for soft x-ray synchrotron experiments which allows conducting a wide range of static and dynamic experiments. Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. The versatility of the instrument was testified by a series of pilot experiments. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. We demonstrate here the capabilities of the system to host a variety of experiments, featuring ALICE as one of the most versatile and demanded instruments at the Helmholtz Center in Berlin-BESSY II synchrotron center in Berlin, Germany.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface acoustic wave propagation in graphene film

Surface acoustic wave (SAW) propagation in a graphene film on the surface of piezoelectric crystals was studied at the BESSY II synchrotron radiation source. Talbot effect enabled the visualization of the SAW propagation on the crystal surface with the graphene film in a real time mode, and high-resolution x-ray diffraction permitted the determination of the SAW amplitude in the graphene/piezoelectric crystal system. The influence of the SAW on the electrical properties of the graphene film was examined. It was shown that the changing of the SAW amplitude enables controlling the magnitude and direction of current in graphene film on the surface of piezoelectric crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

At-wavelength metrology facility for soft X-ray reflection optics

A new Optics Beamline coupled to a versatile UHV reflectometer is successfully operating at BESSY-II. It is used to carry out at-wavelength characterization and calibration of in-house produced gratings and novel nano-optical devices as well as mirrors and multilayer systems in the UV and XUV spectral region. This paper presents most recent commissioning data of the beamline and shows their correlation with initial beamline design calculations. Special attention is paid to beamline key parameters which determine the quality of the measurements such as high-order suppression and stray light behavior. The facility is open to user operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear chirped slope profile for spatial calibration in slope measuring deflectometry

Slope measuring deflectometry is commonly used by the X-ray optics community to measure the long-spatial-wavelength surface figure error of optical components dedicated to guide and focus X-rays under grazing incidence condition at synchrotron and free electron laser beamlines. The best performing instruments of this kind are capable of absolute accuracy on the level of 30-50 nrad. However, the exact bandwidth of the measurements, determined at the higher spatial frequencies by the instrument’s spatial resolution, or more generally by the instrument’s modulation transfer function (MTF) is hard to determine. An MTF calibration method based on application of a test surface with a one-dimensional (1D) chirped height profile of constant amplitude was suggested in the past. In this work, we propose a new approach to designing the test surfaces with a 2D-chirped topography, specially optimized for MTF characterization of slope measuring instruments. The design of the developed MTF test samples based on the proposed linear chirped slope profiles (LCSPs) is free of the major drawback of the 1D chirped height profiles, where in the slope domain, the amplitude strongly increases with the local spatial frequency of the profile. We provide the details of fabrication of the LCSP samples. The results of first application of the developed test samples to measure the spatial resolution of the BESSY-NOM at different experimental arrangements are also presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new generation of x-ray spectrometry UHV instruments at the SR facilities BESSY II, ELETTRA and SOLEIL

A novel type of ultra-high vacuum instrument for X-ray reflectometry and spectrometry-related techniques for nanoanalytics by means of synchrotron radiation (SR) has been constructed and commissioned at BESSY II. This versa-tile instrument was developed by the PTB, Germany’s national metrology institute, and includes a 9-axis manipulator that allows for an independent alignment of the samples with respect to all degrees of freedom. In addition, it integrates a rotational and translational movement of several photodiodes as well as a translational movement of a beam-geometry-defining aperture system. Thus, the new instrument enables various analytical techniques based on energy dispersive X-ray detectors such as reference-free X-Ray Fluorescence (XRF) analysis, total-reflection XRF, grazing-incidence XRF, in addition to optional X-Ray Reflectometry (XRR) measurements or polarization-dependent X-ray absorption fine structure analyses (XAFS). Samples having a size of up to (100 × 100) mm{sup 2}; can be analyzed with respect to their mass deposition, elemental, spatial or species composition. Surface contamination, nanolayer composition and thickness, depth pro-file of matrix elements or implants, nanoparticles or buried interfaces as well as molecular orientation of bonds can be accessed. Three technology transfer projects of adapted instruments have enhanced X-Ray Spectrometry (XRS) research activities within Europe at the synchrotron radiation facilities ELETTRA (IAEA) and SOLEIL (CEA/LNE-LNHB) as well as at the X-ray innovation laboratory BLiX (TU Berlin) where different laboratory sources are used. Here, smaller chamber requirements led PTB in cooperation with TU Berlin to develop a modified instrument equipped with a 7-axis manipulator: reduced freedom in the choice of experimental geometry modifications (absence of out-of-SR-plane and reference-free XRS options) has been compensated by encoder-enhanced angular accuracy for GIXRF and XRR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Survey and adjustment methods applied on an 11 axes high performance reflectometer for synchrotron radiation

At BESSY-II a new UV-and XUV optics beamline [1] has recently been setup with an in-house developed versatile reflectometer [2], [3], [4] for at-wavelength metrology on reflective and diffractive optical elements up to 4 kg mass. High precision measurements of the reflection and polarization properties are feasible by a 360° azimuthal rotation of the sample around the beam of light, where samples can be adjusted reproducibly with a novel UHV-Tripod within arc sec and μm precision. The azimuthal rotation requires an extremely high precision adjustment of the goniometer axis with respect to the incident light beam. Here we describe sophisticated methods with which we achieve nearly perfect agreement of the azimuthal rotation axis and the synchrotron beam in the 30 arc sec range. By using geodetic instruments (lasertracker, theodolite, autocollimator) the quality of the reflectometer UHV-mechanics has been characterized with respect to stiffness and radial run out with highest precision [5].

43 PARTICLE ACCELERATORS↗

Resonant Raman scattering of polarized and unpolarized x-ray radiation from Mg, Al, and Si

The x-ray resonant Raman scattering (RRS) effect of polarized and unpolarized radiation in the vicinity of the 1s absorption threshold of low-Z elements such as magnesium, aluminum, and silicon is investigated. For the polarized and tunable exciting x-ray radiation the plane grating monochromator (PGM) beam line at the PTB laboratory in the BESSY II synchrotron radiation facility was employed, while unpolarized x-ray beams were induced by 1-MeV proton beam irradiation on various pure thick targets. For the latter case, a novel proton-induced x-ray fluorescence scattering chamber was designed and installed at the Tandem accelerator laboratory of the Institute of Nuclear Physics at N.C.S.R. 'Demokritos'. The total RRS cross sections deduced from both independent excitation modes were found to be in a good agreement, within the experimental uncertainties. The predictions of the existing theory with respect to the dependence of the RRS to the incident beam polarization state is calculated and discussed with respect to the experimental results.

36 MATERIALS SCIENCE↗

Ultrahigh-Resolution Soft-X-Ray Microscopy with Zone Plates in High Orders of Diffraction

We present an x-ray optical approach to overcome the current limitations in spatial resolution of x-ray microscopes. Our new BESSY full-field x-ray microscope operates with an energy resolution up to E/DELTAE=10{sup 4}. We demonstrate that under these conditions it is possible to employ high orders of diffraction for imaging. Using the third order of diffraction of a zone plate objective with 25 nm outermost zone width, 14 nm lines and spaces of a multilayer test structure were clearly resolved. We believe that high-order imaging paves the way towards sub-10-nm real space x-ray imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗