Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLOOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A 1D–0D–3D coupled model for simulating blood flow and transport processes in breast tissue

In this work, we present mixed dimensional models for simulating blood flow and transport processes in breast tissue and the vascular tree supplying it. These processes are considered, to start from the aortic inlet to the capillaries and tissue of the breast. Large variations in biophysical properties and flow conditions exist in this system necessitating the use of different flow models for different geometries and flow regimes. In total, we consider four different model types. First, a system of 1D nonlinear hyperbolic partial differential equations (PDEs) is considered to simulate blood flow in larger arteries with highly elastic vessel walls. Second, we assign 1D linearized hyperbolic PDEs to model the smaller arteries with stiffer vessel walls. The third model type consists of ODE systems (0D models). It is used to model the arterioles and peripheral circulation. Finally, homogenized 3D porous media models are considered to simulate flow and transport in capillaries and tissue within the breast volume. Sink terms are used to account for the influence of the venous and lymphatic systems. Combining the four model types, we obtain two different 1D–0D–3D coupled models for simulating blood flow and transport processes: The first model results in a fully coupled 1D–0D–3D model covering the complete path from the aorta to the breast combining a generic arterial network with a patient specific breast network and geometry. The second model is a reduced one based on the separation of the generic and patient specific parts. The information from a calibrated fully coupled model is used as inflow condition for the patient specific sub-model allowing a significant computational cost reduction. Several numerical experiments are conducted to calibrate the generic model parameters and to demonstrate realistic flow simulations compared to existing data on blood flow in the human breast and vascular system. Moreover, we use two different breast vasculature and tissue data sets to illustrate the robustness of our reduced sub-model approach.

multiscale blood flow models↗

Interplay between liver and blood stages of Plasmodium infection dictates malaria severity via γδ T cells and IL-17-promoted stress erythropoiesis

Plasmodium replicates within the liver prior to reaching the bloodstream and infecting red blood cells. Because clinical manifestations of malaria only arise during the blood stage of infection, a perception exists that liver infection does not impact disease pathology. By developing a murine model where the liver and blood stages of infection are uncoupled, we showed that the integration of signals from both stages dictated mortality outcomes. This dichotomy relied on liver stage-dependent activation of Vγ4 + γδ T cells. Subsequent blood stage parasite loads dictated their cytokine profiles, where low parasite loads preferentially expanded IL-17-producing γδ T cells. IL-17 drove extra-medullary erythropoiesis and concomitant reticulocytosis, which protected mice from lethal experimental cerebral malaria (ECM). Adoptive transfer of erythroid precursors could rescue mice from ECM. Modeling of γδ T cell dynamics suggests that this protective mechanism may be key for the establishment of naturally acquired malaria immunity among frequently exposed individuals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multimodal analysis for human ex vivo studies shows extensive molecular changes from delays in blood processing

Multi-omic profiling of human peripheral blood is increasingly utilized to identify biomarkers and pathophysiologic mechanisms of disease. The importance of these platforms in clinical and translational studies led us to investigate the impact of delayed blood processing on the numbers and state of peripheral blood mononuclear cells (PBMC) and on the plasma proteome. Similar to previous studies, we show minimal effects of delayed processing on the numbers and general phenotype of PBMCs up to 18 hours. In contrast, profound changes in the single-cell transcriptome and composition of the plasma proteome become evident as early as 4 hours after blood draw. These reflect patterns of cellular activation across diverse cell types that lead to progressive distancing of the gene expression state and plasma proteome from native in situ biology. Differences accumulating during an overnight rest (18 hours) would confound relevant biologic variance related to many underlying disease states.

59 BASIC BIOLOGICAL SCIENCES↗

Microbiomes of frozen blood plasma samples reveal potential pathogens in wild birds and rodents

The lack of genomic data on pathogens from wildlife severely limits our ability to track transmission patterns and trace the origins of an outbreak. There are currently millions of wildlife samples in biobanks around the world, including blood samples. Blood has traditionally been viewed as a sterile environment in healthy individuals, but recent evidence suggests that this is not the case, especially for wild animals. Our goal was to determine whether frozen plasma samples can be surveyed using 16S sequencing to provide information about potential hosts for pathogens for a more complete understanding of disease systems. We sequenced blood plasma from wild North American deer mice ( Peromyscus maniculatus ) and American kestrels ( Falco sparverius ) that were cryogenically stored for 7 and 13 years, respectively, and compared two DNA extraction kits. The kestrel samples contained a very high number of reads that could not be identified to phylum compared to the mouse samples. The two kits differed in the phyla and genera that were detected, and the Zymo kit, which is optimized for plasma and serum, produced more high-quality reads for both kestrel and mouse samples. We identified several pathogenic genera, including Mycoplasma, Escherichia-Shigella , and Bartonella . Sequencing blood samples for pathogens could potentially have broad applications for identifying important reservoir hosts for pathogen transmission and provide a reduced set of species on which to follow up.

59 BASIC BIOLOGICAL SCIENCES↗

A centrifugal microfluidic cross-flow filtration platform to separate serum from whole blood for the detection of amphiphilic biomarkers

Abstract The separation of biomarkers from blood is straightforward in most molecular biology laboratories. However, separation in resource-limited settings, allowing for the successful removal of biomarkers for diagnostic applications, is not always possible. The situation is further complicated by the need to separate hydrophobic signatures such as lipids from blood. Herein, we present a microfluidic device capable of centrifugal separation of serum from blood at the point of need with a system that is compatible with biomarkers that are both hydrophilic and hydrophobic. The cross-flow filtration device separates serum from blood as efficiently as traditional methods and retains amphiphilic biomarkers in serum for detection.

59 BASIC BIOLOGICAL SCIENCES↗

Superiority of compensatory reserve measurement compared with the Shock index for early and accurate detection of reduced central blood volume status

Shock index (SI) equals the ratio of heart rate (HR) to systolic blood pressure (SBP) with clinical evidence that it is more sensitive for trauma patient status assessment and prediction of outcome compared with either HR or SBP alone. We used lower body negative pressure (LBNP) as a human model of central hypovolemia and compensatory reserve measurement (CRM) validated for accurate tracking of reduced central blood volume to test the hypotheses that SI: (1) presents a late signal of central blood volume status; (2) displays poor sensitivity and specificity for predicting the onset of hemodynamic decompensation; and (3) cannot identify individuals at greatest risk for the onset of circulatory shock. We measured HR, SBP, and CRM in 172 human subjects (19–55 years) during progressive LBNP designed to determine tolerance to central hypovolemia as a model of hemorrhage. Subjects were subsequently divided into those with high tolerance (HT) (n = 118) and low tolerance (LT) (n = 54) based on completion of 60 mm Hg LBNP. The time course relationship between SI and CRM was determined and receiver operating characteristic (ROC) area under the curve (AUC) was calculated for sensitivity and specificity of CRM and SI to predict hemodynamic decompensation using clinically defined thresholds of 40% for CRM and 0.9 for SI. The time and level of LBNP required to reach a SI = 0.9 (~60 mm Hg LBNP) was significantly greater (p < 0.001) compared with CRM that reached 40% at ~40 mm Hg LBNP. Shock index did not differ between HT and LT subjects at 45 mm Hg LBNP levels. ROC AUC for CRM was 0.95 (95% CI = 0.94–0.97) compared with 0.91 (0.89–0.94) for SI (p = 0.0002). Despite high sensitivity and specificity, SI delays time to detect reductions in central blood volume with failure to distinguish individuals with varying tolerances to central hypovolemia.

60 APPLIED LIFE SCIENCES↗

Blood Plasma Self-Separation Technologies during the Self-Driven Flow in Microfluidic Platforms

Blood plasma is the most commonly used biofluid in disease diagnostic and biomedical analysis due to it contains various biomarkers. The majority of the blood plasma separation is still handled with centrifugation, which is off-chip and time-consuming. Therefore, in the Lab-on-a-chip (LOC) field, an effective microfluidic blood plasma separation platform attracts researchers’ attention globally. Blood plasma self-separation technologies are usually divided into two categories: active self-separation and passive self-separation. Passive self-separation technologies, in contrast with active self-separation, only rely on microchannel geometry, microfluidic phenomena and hydrodynamic forces. Passive self-separation devices are driven by the capillary flow, which is generated due to the characteristics of the surface of the channel and its interaction with the fluid. Comparing to the active plasma separation techniques, passive plasma separation methods are more considered in the microfluidic platform, owing to their ease of fabrication, portable, user-friendly features. We propose an extensive review of mechanisms of passive self-separation technologies and enumerate some experimental details and devices to exploit these effects. The performances, limitations and challenges of these technologies and devices are also compared and discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges and the Evolving Landscape of Assessing Blood-Based PD-L1 Expression as a Biomarker for Anti-PD-(L)1 Immunotherapy

While promising, PD-L1 expression on tumor tissues as assessed by immunohistochemistry has been shown to be an imperfect biomarker that only applies to a limited number of cancers, whereas many patients with PD-L1-negative tumors still respond to anti-PD-(L)1 immunotherapy. Recent studies using patient blood samples to assess immunotherapeutic responsiveness suggests a promising approach to the identification of novel and/or improved biomarkers for anti-PD-(L)1 immunotherapy. In this review, we discuss the advances in our evolving understanding of the regulation and function of PD-L1 expression, which is the foundation for developing blood-based PD-L1 as a biomarker for anti-PD-(L)1 immunotherapy. We further discuss current knowledge and clinical study results for biomarker identification using PD-L1 expression on tumor and immune cells, exosomes, and soluble forms of PD-L1 in the peripheral blood. Finally, we discuss key challenges for the successful development of the potential use of blood-based PD-L1 as a biomarker for anti-PD-(L)1 immunotherapy.

59 BASIC BIOLOGICAL SCIENCES↗

Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood

Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.

36 MATERIALS SCIENCE↗

Establishing metrics to quantify spatial similarity in spherical and red blood cell distributions

As computational power increases and systems with millions of red blood cells can be simulated, it is important to note that varying spatial distributions of cells may affect simulation outcomes. Since a single simulation may not represent the ensemble behavior, many different configurations may need to be sampled to adequately assess the entire collection of potential cell arrangements. In order to determine both the number of distributions needed and which ones to run, we must first establish methods to identify well-generated, randomly placed cell distributions and to quantify distinct cell configurations. We utilize metrics to assess (1) the presence of any underlying structure to the initial cell distribution and (2) similarity between cell configurations. We propose the use of the radial distribution function to identify long-range structure in a cell configuration and apply it to a randomly distributed and structured set of red blood cells. To quantify spatial similarity between two configurations, we make use of the Jaccard index, and characterize sets of red blood cell and sphere initializations. As an extension to our work submitted to the International Conference on Computational Science, we significantly increase our data set size from 72 to 1048 cells, include a similar set of studies using spheres, compare the effects of varying sphere size, and utilize the Jaccard index distribution to probe sets of extremely similar configurations. Our results show that the radial distribution function can be used as a metric to determine long-range structure in both distributions of spheres and RBCs. We determine that the ideal case of spheres within a cube versus bi-concave shaped cells within a cylinder affects the shape of the Jaccard index distributions, as well as the range of Jaccard values, showing that both the shape of particle and the domain may play a role. Furthermore, we also find that the distribution is able to capture very similar configurations through Jaccard index values greater than 95% when appending several nearly identical configurations into the data set.

59 BASIC BIOLOGICAL SCIENCES↗

Antimicrobial Peptides Can Facilitate Whole Blood Safety from Bacteria: A Proof of Concept

With continuous improvements to blood donor deferrals and the availability of sensitive tests for donation screening for infectious agents, bacterial contamination of whole blood (WB) and blood components stored for transfusion is a rare event. Nonetheless, it still occurs and remains a transfusion-associated risk in terms of septic transfusion reactions (STRs) and transfusion-transmitted bacterial infections with morbidity and mortality outcomes. One of the risk mitigation strategies for bacterial contamination is to implement treatment with currently available proactive pathogen reduction technologies (PRTs) for these transfusion products. Here, as a proof of concept, we tested two recently developed unique cationic antimicrobial peptides (AMPs; D-CONGA and D-CONGA-Q7) for WB safety from bacterial contamination. In this study, WB was inoculated with Escherichia coli and Staphylococcus epidermidis and treated with the two peptides to evaluate their bactericidal efficacy. The results demonstrated that D-CONGA and D-CONGA-Q7 exhibit potent inhibitory activity against the bacteria with a minimal inhibitory concentration (MIC) range of 4–8 and 1–8 μM, respectively, depending on the bacterial species tested. Time-kill kinetics further confirmed that the peptides exhibit bactericidal efficacy at 8 μM by achieving a 5-log 10 reduction (99.999%) of the bacterial load in WB with a time-dependent killing profile. Furthermore, even at 20 μM, the AMPs did not negatively impact hemolysis or hemostatic properties. We have further demonstrated using a cationic exchange resin that the cationic AMPs can be separated and removed from WB after the peptide treatments. During 35-day WB storage at 2–8 °C, 4 μM D-CONGA-Q7 one-time treatment prevented S. epidermidis growth and preserved WB quality and integrity. Overall, the results described here provide the first proof of concept that certain AMPs, such as D-CONGA and D-CONGA-Q7, can facilitate WB safety from bacteria during storage.

60 APPLIED LIFE SCIENCES↗

Peripheral blood hematology, plasma biochemistry, and the optimization of an in vitro immune-based assay in the brown watersnake ( Nerodia taxispilota )

Reptiles represent a phylogenetic lineage that provides a unique link between ectothermic anamniotes and endothermic amniotes. Compared to mammalian and avian species, our understanding of the reptilian immune system is greatly lacking. This gap in knowledge is largely due to an absence of established immune-based assays or specific reagents for these species. In the present study, brown watersnakes (Nerodia taxispilota) were live-captured in the wild, sexed, weighed, measured, bled via the caudal vein and released. At 24 hr post-collection, peripheral blood leukocytes were enriched and evaluated with an established mammalian in-vitro lymphocyte proliferation assay. Snake peripheral blood leukocyte enrichment yielded > 90% lymphocytes with viabilities averaging 81.5%. Baseline physiologic data for N. taxispilota, including hematology and total solids, leukocyte differentials, cell recovery and plasma biochemistry, were also collected. Cells cultured with Concanavalin A exhibited significantly increased proliferation at both 72 and 96 hr. Furthermore, these preliminary results show that enriched peripheral blood from wild-caught N. taxispilota provides a sufficient yield of leukocytes that can be cultured and functionally evaluated using a standard mammalian in-vitro immune-based assay.

59 BASIC BIOLOGICAL SCIENCES↗

Defining blood hematology reference values in female pig-tailed macaques ( Macaca nemestrina ) using the Isolation Forest algorithm

Background: Pig-tailed macaques (PTMs) are commonly used as preclinical models to assess antiretroviral drugs for HIV prevention research. Drug toxicities and disease pathologies are often preceded by changes in blood hematology. To better assess the safety profile of pharmaceuticals, we defined normal ranges of hematological values in PTMs using an Isolation Forest (iForest) algorithm. Methods: Eighteen female PTMs were evaluated. Blood was collected 1–24 times per animal for a total of 159 samples. Complete blood counts were performed, and iForest was used to analyze the hematology data to detect outliers. Results: Median, IQR, and ranges were calculated for 13 hematology parameters. From all samples, 22 outliers were detected. These outliers were excluded from the reference index. Conclusions: Using iForest, we defined a normal range for hematology parameters in female PTMs. This reference index can be a valuable tool for future studies evaluating drug toxicities in PTMs.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Blood Rheology and Turbulence Models in the Numerical Simulation of Aneurysms

An aneurysm is a vascular malformation that can be classified according to its location (cerebral, aortic) or shape (saccular, fusiform, and mycotic). Recently, the study of blood flow interaction with aneurysms has gained attention from physicians and engineers. Shear stresses, oscillatory shear index (OSI), gradient oscillatory number (GON), and residence time have been used as variables to describe the hemodynamics as well as the origin and evolution of aneurysms. However, the causes and hemodynamic conditions that promote their growth are still under debate. The present work presents numerical simulations of three types of aneurysms: two aortic and one cerebral. Simulation results showed that the blood rheology is not relevant for aortic aneurysms. However, for the cerebral aneurysm case, blood rheology could play a relevant role in the hemodynamics. The evaluated turbulence models showed equivalent results in both cases. Lastly, a simulation considering the fluid–structure interaction (FSI) showed that this phenomenon is the dominant factor for aneurysm simulation.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

Artificial intelligence velocimetry and microaneurysm-on-a-chip for three-dimensional analysis of blood flow in physiology and disease

Significance Microfluidics is an important in vitro platform to gain insights into mechanics of blood flow and mechanisms of pathophysiology of human diseases. Extraction of 3D fields in microfluidics with dense cell suspensions remains a formidable challenge. We present artificial-intelligence velocimetry (AIV) as a general platform to determine 3D flow fields and a microaneurysm-on-a-chip to simulate blood flow in microaneurysms in patients with diabetic retinopathy. AIV is built on physics-informed neural networks that integrate seamlessly 2D images from microfluidic experiments or in vivo observations with physical laws to estimate full 3D velocity and stress fields. AIV could be integrated into imaging technologies to automatically infer key hemodynamic metrics from in vivo and in vitro biomedical images.

42 ENGINEERING↗

Spaceflight-Associated Changes of snoRNAs in Peripheral Blood Mononuclear Cells and Plasma Exosomes—A Pilot Study

During spaceflight, astronauts are exposed to various physiological and psychological stressors that have been associated with adverse health effects. Therefore, there is an unmet need to develop novel diagnostic tools to predict early alterations in astronauts’ health. Small nucleolar RNA (snoRNA) is a type of short non-coding RNA (60–300 nucleotides) known to guide 2'-O-methylation (Nm) or pseudouridine (ψ) of ribosomal RNA (rRNA), small nuclear RNA (snRNA), or messenger RNA (mRNA). Emerging evidence suggests that dysregulated snoRNAs may be key players in regulating fundamental cellular mechanisms and in the pathogenesis of cancer, heart, and neurological disease. Therefore, we sought to determine whether the spaceflight-induced snoRNA changes in astronaut’s peripheral blood (PB) plasma extracellular vesicles (PB-EV) and peripheral blood mononuclear cells (PBMCs). Using unbiased small RNA sequencing (sRNAseq), we evaluated changes in PB-EV snoRNA content isolated from astronauts (n = 5/group) who underwent median 12-day long Shuttle missions between 1998 and 2001. Using stringent cutoff (fold change > 2 or log 2 -fold change >1, FDR < 0.05), we detected 21 down-and 9—up-regulated snoRNAs in PB-EVs 3 days after return (R + 3) compared to 10 days before launch (L-10). qPCR validation revealed that SNORA74A was significantly down-regulated at R + 3 compared to L-10. We next determined snoRNA expression levels in astronauts’ PBMCs at R + 3 and L-10 (n = 6/group). qPCR analysis further confirmed a significant increase in SNORA19 and SNORA47 in astronauts’ PBMCs at R + 3 compared to L-10. Notably, many downregulated snoRNA-guided rRNA modifications, including four Nms and five ψs. Our findings revealed that spaceflight induced changes in PB-EV and PBMCs snoRNA expression, thus suggesting snoRNAs may serve as potential novel biomarkers for monitoring astronauts’ health.

60 APPLIED LIFE SCIENCES↗

Development of QSAR models to predict blood-brain barrier permeability

Assessing drug permeability across the blood-brain barrier (BBB) is important when evaluating the abuse potential of new pharmaceuticals as well as developing novel therapeutics that target central nervous system disorders. One of the gold-standard in vivo methods for determining BBB permeability is rodent log BB; however, like most in vivo methods, it is time-consuming and expensive. In the present study, two statistical-based quantitative structure-activity relationship (QSAR) models were developed to predict BBB permeability of drugs based on their chemical structure. The in vivo BBB permeability data were harvested for 921 compounds from publicly available literature, non-proprietary drug approval packages, and University of Washington’s Drug Interaction Database. The cross-validation performance statistics for the BBB models ranged from 82 to 85% in sensitivity and 80–83% in negative predictivity. Additionally, the performance of newly developed models was assessed using an external validation set comprised of 83 chemicals. Overall, performance of individual models ranged from 70 to 75% in sensitivity, 70–72% in negative predictivity, and 78–86% in coverage. The predictive performance was further improved to 93% in coverage by combining predictions across the two software programs. These new models can be rapidly deployed to predict blood brain barrier permeability of pharmaceutical candidates and reduce the use of experimental animals.

59 BASIC BIOLOGICAL SCIENCES↗