Search NASA⌕ Search

SEARCH · Search NASA

Results for “BLOWERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High Temperature Anode Recycle Blower for Solid Oxide Fuel Cell, Phase II (Final Report)

Broad commercialization of solid oxide fuel cells (SOFCs) requires anode offgas recycle blowers (ARCB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This report presents details of a DOE-funded Phase II effort conducted by Mohawk Innovative Technology, Inc. (MiTi®) for the development and testing of an oil-free, low cost, high-temperature centrifugal ARCB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. This Phase II builds on the results of a successful Phase I development project that resulted in the demonstration of a low TRL-6 prototype, shown in Figure 1. This Phase II final report presents design improvements over the Phase I prototype, presents the assembled test ARCBs, and discusses the advantages of this novel technology, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology. The specific objectives of this project, as stated in the statement of program objectives (SOPO) were 1) to follow the methodology of design for manufacturing (or manufacturability) and assembly for implementing improvements identified as part of the Phase I effort with the purpose of reducing cost, enabling mass production, and facilitating the commercialization of a revised ARCB design, and 2) to fabricate four complete ARCB units based on the revised design and demonstrating their performance in both a laboratory setting and in an actual SOFC power plant. Execution of this SOPO would be supported by a number of technical tasks resulting in the fabrication and testing of the prototypes. To this end, MiTi continued the teaming relationship started during Phase I of the program with subcontracting partner FuelCell Energy, Inc. (FCE), which integrated (under a parallel effort funded by DOE Award DE-FE0026199) a modular 200 kWe SOFC power plant. MiTi and FCE coordinated to ultimately incorporate one of MiTi’s ARCB prototypes into one of the 100 kWe SOFC Modular Power Blocks (MPB) that constitute the core of FCE’s SOFC power plant for in-situ long-duration testing. Additionally, MiTi would explore the scalability and extendibility of the technology to other applications, as well as conduct a basic techno-economic analysis.

03 NATURAL GAS↗

Blower Cooling of Finned Cylinders

Several electrically heated finned steel cylinders enclosed in jackets were cooled by air from a blower. The effect of the air conditions and fin dimensions on the average surface heat-transfer coefficient q and the power required to force the air around the cylinders were determined. Tests were conducted at air velocities between the fins from 10 to 130 miles per hour and at specific weights of the air varying from 0.046 to 0.074 pound per cubic foot. The fin dimensions of the cylinders covered a range in pitches from 0.057 to 0.25 inch average fin thicknesses from 0.035 to 0.04 inch, and fin widths from 0.67 to 1.22 inches.

Schey, Oscar W↗

Measurement of the turbulence intensity behind a two-dimensional cascade and in a three-stage axial blower

Turbulence intensity (Tu) measurements were made in two-dimensional and rotating cascades of blades in a low-speed cascade wind tunnel using hot-wire probes as sensors. The local Tu at Re = 1.6x100000 was determined in the wake zone behind a two-dimensional cascade. Then the values were recomputed for a rotating cascade, giving a mean turbulence intensity of 6.5% at 1/10 chord downstream and 2.9% at one chord. Fans were used for measurements on the rotating cascade. Re was equal to 7x100000. Frequency analysis was employed to separate the actual Tu of the entry flow from the effects caused by interaction with the rotor blades, showing that the true Tu increased from a few tenths of a percent to 6.6% in the 1st rotor, and from 7.2 to 9.3% in the 2d rotor. The Tu behind the 3d rotor was equal to 8.9%.

Kiock, R.↗

Performance of High-pressure-ratio Axial-flow Compressor Using Highly Cambered NACA 65-series Blower Blades at High Mach Numbers

A complete stage of an axial-flow compressor was designed and built to investigate the possibility of obtaining a high pressure ratio with an acceptable efficiency through the use of the optimum combination of high blade loading and high relative inlet Mach number. Over-all stage performance was investigated over a range of flows at equivalent tip speeds of 418 to 836 feet per second. At design speed (836 ft/sec), a peak total-pressure ration of 1.445 was obtained with an adiabatic efficiency of 0.89. For design angle of attack at the mean radius, a total-pressure ratio of 1.392 was obtained.

COMPRESSORS - AXIAL FLOW↗

Development of Air-cooled Engines with Blower Cooling

With the aid of a heating device, the heat transfer to cylinders with conical fins of various forms is determined both for shrouded and exposed cylinders. Simultaneously the pressure drop for overcoming the resistance to the motion of air between the fins of the enclosed cylinder is measured. Thus the relations between the heat transfer and the energy required for cooling are discovered. The investigations show that the heat transfer in a conducted air flow is much greater than in a free current and that further improvement, as compared with free exposure, is possible through narrower spaces between the fins.

Lohner, Kurt↗

The Effect of Air Separations on Fast Pyrolysis Products for Forest Residue Feedstocks

This study investigates the intricate relationship between biomass preprocessing and pyrolysis product yields, employing the air classification technique for the treatment of loblolly pine residues with varying moisture content. A comprehensive exploration of the physicochemical properties of air-classified loblolly pine informs a sophisticated pyrolysis simulation model. Given the complex and multifaceted nature of biomass pyrolysis, operating across diverse temporal and spatial scales, a pyrolysis kinetics-based CFD–DEM simulation method is employed to predict product yields. Results showed that the elevated moisture content amplifies particle adhesiveness, necessitating augmented air velocities for effective separation, thereby influencing the efficiency of the separation process. While carbon and hydrogen contents exhibit relative stability across diverse moisture contents and blower frequencies, the oxygen content undergoes noticeable changes. For example, the oxygen contents were measured as 29.2 and 38.6 wt% in the light fraction of 30% moisture content sample at blower frequencies of 10 and 20 Hz, respectively. An intriguing finding emerges from pyrolysis simulation, indicating that a lower blower frequency in air classification moderately enhances bio-oil yield and significantly improves its quality, particularly in terms of water content. For instance, the water content in the bio-oil was about 1.5% and 10% in the heavy and light fractions, respectively from 10% moisture sample under 15 Hz blower frequency. In summary, a detailed understanding and strategic manipulation of critical material attributes in biomass through efficient fractionation techniques are imperative for advancing fast pyrolysis as a sustainable avenue for renewable energy and chemical production.

09 BIOMASS FUELS↗

Experimental Investigation of a Model of a Two-Stage Turboblower

In the present paper an investigation is made of two stages of a multistage turboblower having a vaneless diffuser behind the impeller and guide vanes at the inlet to the nest stage. The method employed was that of investigating the performance of the successive elements of the blower (the impeller, vaneless diffuser, ets.) whereby the kinematics of the flow through the blower could be followed and the pressure at the different points computed. The character of the flow and the physical significance of the loss coefficients could thereby be determined so as to secure the best agreement of the computed with the actual performance of the blower. Since the tests were carried out for various delivery volumes, the dependence of the coefficients on a number of factors (angle of attack, velocities, etc.) could be obtained. The distribution of the losses that occur during the transformation of dynamic pressure at the impeller exit into static pressure could be found and likewise the range within which the friction coefficient varies in the vaneless diffuser. With the aid of factors having a certain physical significance, the centrifugal blower could be computed on the basis of a more or less schematical consideration of the phenomena occuring during the air flow through it, and the use of arbitrary factors and recourse to the geometrical similtude law thus avoided. The present investigation largely summarizes all the previous work af the CHI Blower Section on the different elements of a centrifugal blower. Some considerations on the analysis of model test data for application to full-scale are presented in the appendix.

Dovjik, s.↗

Data for Design of Entrance Vanes from Two-Dimensional Tests of Airfoils in Cascade

As a part of a program of the NACA directed toward increasing the efficiency of compressors and turbines, data were obtained for application to the design of entrance vanes for axfax-flow compressors or turbines. A series of blower-blade sections with relatively high critical speeds have been developed for turning air efficiently from 0 deg to 80 deg starting with an axial direction. Tests were made of five NACA 65-series blower blades (modified NACA 65(216)-010 airfoils) and of four experimentally designed blower blades in a stationary cascade at low Mach numbers. The turning effectiveness and the pressure distributions of these blade sections at various angles of attack were evaluated over a range of solidities near 1. Entrance-vane design charts are presented that give a blade section and angle of attack for any desired turning angle. The blades thus obtained operate with peak-free pressure distributions. Approximate critical Mach numbers were calculated from the pressure distributions.

FLOW-VANES, GUIDE↗

Reducing Cost of Chlorinated Volatile Organic Compound Remediation by Transitioning from Active to Passive Soil Vapor Extraction - 20157

Areas of high chlorinated volatile organic compound (cVOC) contamination at the Savannah River Site (SRS) have been undergoing remediation via soil vapor extraction, sometimes coupled with thermal treatments to enhance extraction rates. These active systems are effective in removing large amounts of contaminant mass from the subsurface and mitigating the impacts to groundwater. However, as extraction rates decline, costs must be evaluated with respect to the benefit of continued active operation. A decision framework for identifying conditions when a transition to a more passive remediation is appropriate has been developed with state and federal regulatory agencies. Two remediation areas have recently been transitioned from active soil vapor extraction (ASVE) to passive soil vapor extraction (PSVE) at the SRS. Performance evaluation goals including plume stabilization, overall mass removal trends, environmental sustainability and costs were considered in transitioning from active remediation to passive technologies at both sites. At the Dynamic Underground Stripping (DUS) project at the M-Area Settling Basin, ASVE was combined with steam injection to extract cVOCs during active operations. Steam injection occurred from September 2005 to September 2009. DUS utilized 63 steam injection wells, 34 active vapor extraction wells, and 3 active soil vapor extraction units (SVEUs). Two active SVEUs had 60 horsepower blowers; the third had a 25-horsepower blower. Mass removal was closely tracked during DUS operations; over 181,437 kilograms (400,000 pounds) of cVOCs were removed while active steam injection occurred. After steaming was stopped, ASVE continued. The 34 active wells were evaluated in 2012. The ASVE wells were grouped into categories of high, medium, and low extraction rates. High producing wells remained connected to a single active SVEU. Low producing wells were abandoned, and the medium producing wells were transitioned to PSVE (Microblowers{sup TM}). Microblowers{sup TM} utilize a dedicated blower per well and are solar powered. This passive technology provides energy, maintenance, and operation costs savings while still providing an efficient reduction in cVOC migration to groundwater. In 2018, the remaining ASVE wells were evaluated again. The purpose of this testing was to identify which wells removed the most mass. An optimal well configuration was determined. The criteria to discontinue ASVE was removal of less than 18 kilograms (40 pounds) per week of cVOCs. After 3 months of shutdown (rebound conditions), 2.7 kilograms (5.9 pounds) of cVOCs per week were being removed. Data from the rebound test justified ending ASVE and transitioning wells with higher extraction rates to PSVE. Wells that had depleted the cVOC mass within their zone of influence were abandoned. Performance data from existing PSVE wells justified ending PSVE at wells with depleted extraction rates. Currently the system has 16 PSVE wells operating. Another ASVE system was being used to treat cVOC contaminated soil at the A-Area Miscellaneous Rubble Pile (AMRP) at SRS. System operation began in 2004, with 7 ASVE wells connected to a 60- horsepower blower. Mass removal rates and contaminant concentrations remained consistently low over the ASVE lifespan at AMRP. This indicated that mass removal was diffusion limited. With this data, the 7 ASVE wells were transitioned to PSVE in 2017. Twelve pressure monitoring points were also transitioned to PSVE wells. AMRP currently has 19 PSVE wells operating. Both transitions from active to passive remediation had concurrence from the United States Environmental Protection Agency and the South Carolina Department of Health and Environmental Control. These transitions ensure that only the necessary amount of energy is being exerted to remediate the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A study of the factors affecting boundary layer two-dimensionality in wind tunnels

The effect of screens, honeycombs, and centrifugal blowers on the two-dimensionality of a boundary layer on the test section floors of low-speed blower tunnels is studied. Surveys of the spanwise variation in surface shear stress in three blower tunnels revealed that the main component responsible for altering the spanwise properties of the test section boundary layer was the last screen, thus confirming previous findings. It was further confirmed that a screen with varying open-area ratio, produced an unstable flow. However, contrary to popular belief, it was also found that for given incoming conditions and a screen free of imperfections, its open-area ratio alone was not enough to describe its performance. The effect of other geometric parameters such as the type of screen, honeycomb, and blower were investigated. In addition, the effect of the order of components in the settling chamber, and of wire Reynolds number were also studied.

Mehta, R. D.↗